{"product_id":"usr-io0080-8000-0440-4040-0404","title":"Industrial IoT Gateway - USR-IO4040\/0440\/0080\/8000\/0404","description":"\u003ch1 style=\"text-align: center;\"\u003eUSR-IO4040\/0440\/0080\/8000\/0404\u003c\/h1\u003e\n\u003ch3 style=\"text-align: center;\"\u003eModular IO Controller\u003c\/h3\u003e\n\u003cp style=\"text-align: center;\"\u003eModular IO controller is a new generation IO controller launched by PUSR. It adopts standard RS485 interface, standard ModbusRTU protocol, can achieve fast application matching. With compact size, DIN rail \u0026amp; wall mounting installation, it can save space.\u003c\/p\u003e\n\u003ch3 style=\"text-align: center;\"\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ch3 style=\"text-align: center;\"\u003eUSR-IO Controller | Extendable Remote I\/O Module\u003c\/h3\u003e\n\u003cp style=\"text-align: center;\"\u003eThe USR-IO series is an advanced and expandable I\/O controller lunched by PUSR, allowing for the desired quantity of I\/O through combinations of the different model. When used with PUSR's M100 or M300, it enables remote control of IO devices. With its unique hardware design, it saves time on installation or removal, featuring push-in terminals that allow users to connect on-site without the need for tools. All these designs make it an ideal solution for a variety of industrial data acquisition applications.\u003c\/p\u003e\n\u003ch3 style=\"text-align: center;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0014\/4313\/5560\/files\/USR1.jpg?v=1737711657\"\u003e\u003c\/h3\u003e\n\u003ch3 style=\"text-align: center;\"\u003e\n\u003cbr\u003eAdvanced Features\u003c\/h3\u003e\n\u003ch3 style=\"text-align: center;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0014\/4313\/5560\/files\/USR2.jpg?v=1737711657\"\u003e\u003c\/h3\u003e\n\u003ch3 style=\"text-align: center;\"\u003e\n\u003cbr\u003eOrdering Guide\u003c\/h3\u003e\n\u003cp style=\"text-align: center;\"\u003ePUSR provides 5 different models of expansion units for users to choose from, please see the table for specific differences between different modules.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0014\/4313\/5560\/files\/USR3.jpg?v=1737711657\"\u003e\u003c\/p\u003e\n\u003ch3 style=\"text-align: center;\"\u003e\n\u003cbr\u003eModbus RTU Supported\u003c\/h3\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cbr\u003eThe USR-IO modular controller supports standard Modbus RTU for data acquisition and control, making integration into control systems extremely straightforward.\u003cbr\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0014\/4313\/5560\/files\/USR4.jpg?v=1737711657\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e \u003c\/p\u003e\n\u003ch3 style=\"text-align: center;\"\u003eIndustrial Grade Design\u003c\/h3\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eEMC Protection:\u003c\/strong\u003e Level 3, IEC 61000\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eWide Operating Temp: \u003c\/strong\u003e-25℃~+75℃\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eHardware Watchdog:\u003c\/strong\u003e Supported\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eFlame retardant rating: \u003c\/strong\u003eV0, burning stops within 10 seconds on a vertical part allowing for drops of plastic that are not inflames.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0014\/4313\/5560\/files\/USR5.jpg?v=1737711657\"\u003e\u003c\/p\u003e\n\u003ch3 style=\"text-align: center;\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch3 style=\"text-align: center;\"\u003eCable Wiring Diagram-Dry Contacts for DI\u003c\/h3\u003e\n\u003cp style=\"text-align: center;\"\u003eFor dry contacts device, users need to connect the USR-IO's power in the whole circuit to detect the status of IO devices, such as detecting the status of switches, buttons, etc.\u003cbr\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0014\/4313\/5560\/files\/USR6.jpg?v=1737711657\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e \u003c\/p\u003e\n\u003ch3 style=\"text-align: center;\"\u003eCable Wiring Diagram-Wet Contacts for DI\u003c\/h3\u003e\n\u003cp style=\"text-align: center;\"\u003eFor wet contact devices, they output voltage signals such as high and low levels, pulses, etc. These devices already have an internal power source and do not require additional power supply. They can be directly connected to the terminals of the USR-IO controller, such as infrared detection, liquid level detection, smoke detection, etc. For the USR-IO controller, the input voltage range is 9-36V. If it exceeds this range, the device's status cannot be detected correctly.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0014\/4313\/5560\/files\/USR7.jpg?v=1737711657\"\u003e\u003c\/p\u003e\n\u003ch3 style=\"text-align: center;\"\u003e\n\u003cbr\u003eCable Wiring Diagram for 2-wire 4-20ma Sensor\u003c\/h3\u003e\n\u003cp style=\"text-align: center;\"\u003eFor two-wire 4-20mA sensors, the sensor itself only has 2 wiring terminals: power + and signal -. These terminals serve both as power supply and signal transmission channels. In this scenario, connecting the sensor's power + to the USR-IO's power + and the sensor's signal - to the USR-IO's AI interface, while connecting USR-IO's COM to the power -, completes the setup.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0014\/4313\/5560\/files\/USR8.jpg?v=1737711657\"\u003e\u003c\/p\u003e\n\u003ch3 style=\"text-align: center;\"\u003e\n\u003cbr\u003eCable Wiring Diagram for 4-wire 4-20ma Sensor\u003c\/h3\u003e\n\u003cp style=\"text-align: center;\"\u003eFor two-wire 4-20mA sensors, the sensor itself only has 2 wiring terminals, serving as both power supply and signal transmission channels. In this scenario, connecting the AI terminal to the power supply circuit enables the detection of the analog signal.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0014\/4313\/5560\/files\/USR9.jpg?v=1737711657\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3 style=\"text-align: center;\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch3 style=\"text-align: center;\"\u003eCable Wiring Diagram for Analog Output (0-10V)\u003c\/h3\u003e\n\u003cp style=\"text-align: center;\"\u003eIn the AO loop, there is no need to connect to a power source.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0014\/4313\/5560\/files\/USR10.jpg?v=1737711657\"\u003e\u003c\/p\u003e\n\u003ch3 style=\"text-align: center;\"\u003e\n\u003cbr\u003eCable Wiring Diagram for Analog Output (4-20 mA)\u003c\/h3\u003e\n\u003cp style=\"text-align: center;\"\u003eIn the AO loop, there is no need to connect to a power source.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0014\/4313\/5560\/files\/USR11.jpg?v=1737711657\"\u003e\u003c\/p\u003e\n\u003ch3 style=\"text-align: center;\"\u003e\n\u003cbr\u003eCable Wiring Diagram for DO\u003c\/h3\u003e\n\u003cp style=\"text-align: center;\"\u003eApplicable when the current is less than 3A. If connecting high-power loads, replace the lighting fixture in the diagram with a relay or an AC contactor.\u003c\/p\u003e\n\u003ch3 style=\"text-align: center;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0014\/4313\/5560\/files\/USR12.jpg?v=1737711657\"\u003e\u003c\/h3\u003e\n\u003ch3 style=\"text-align: center;\"\u003e\n\u003cbr\u003eCable Wiring Diagram for Power Supply\u003c\/h3\u003e\n\u003cp style=\"text-align: center;\"\u003eWhen using multiple IO controllers in combination, only one power supply is supported. Please do not connect multiple power supplies for power input.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0014\/4313\/5560\/files\/USR13.jpg?v=1737711657\"\u003e\u003c\/p\u003e\n\u003ch3 style=\"text-align: center;\"\u003e\n\u003cbr\u003eDetail \u0026amp; Dimension\u003c\/h3\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cbr\u003e\u003cstrong\u003eReload button: \u003c\/strong\u003ePress and hold on for 3~15s to reset the device to factory settings.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eDimension:\u003c\/strong\u003e 79.6*28*110mm\u003c\/p\u003e\n\u003ch3 style=\"text-align: center;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0014\/4313\/5560\/files\/USR14.jpg?v=1737711657\"\u003e\u003c\/h3\u003e\n\u003ch3 style=\"text-align: center;\"\u003e\n\u003cbr\u003eUsed in Conjunction with M100\/M300\u003c\/h3\u003e\n\u003cp style=\"text-align: center;\"\u003eThe USR-IO can be used with PUSR's M100 or M300, which can enable remote control of IO devices. And screwdrivers and other tools are not required for any part of the hardware installation, which can reduce the amount of time required for installation and removal.\u003cbr\u003eUSR-M100\u003cbr\u003eUSR-M300\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0014\/4313\/5560\/files\/USR15.gif?v=1737711658\"\u003e\u003c\/p\u003e\n\u003ch3 style=\"text-align: center;\"\u003e\n\u003cbr\u003eTool-Free Cable Wiring\u003c\/h3\u003e\n\u003cp style=\"text-align: center;\"\u003eThe USR-IO modular controller uses direct-insertion spring terminal blocks, making wiring more convenient.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0014\/4313\/5560\/files\/USR16.gif?v=1737711658\"\u003e\u003c\/p\u003e\n\u003ch3 style=\"text-align: center;\"\u003e\n\u003cbr\u003eAutomatic Production Line Transformation\u003c\/h3\u003e\n\u003cp style=\"text-align: center;\"\u003eIntegrating the IO controller into automated production line equipment, gathering and controlling device actions via RS485, effectively reduces labor costs and enables unmanned supervision of the production line.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0014\/4313\/5560\/files\/USR16.jpg?v=1737711657\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e \u003c\/p\u003e\n\u003ch3 style=\"text-align: center;\"\u003eSmart Home Application\u003c\/h3\u003e\n\u003cp style=\"text-align: center;\"\u003eConnecting the water heater, access control system, motorized curtains, lighting fixtures, and other devices to the IO controller, and integrating them with the control host through RS485 Modbus RTU, enables intelligent home automation and supervision.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0014\/4313\/5560\/files\/USR17.jpg?v=1737711657\"\u003e\u003c\/p\u003e\n\u003ch3 style=\"text-align: center;\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch3 style=\"text-align: center;\"\u003ePARAMETERS\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003cstrong\u003eItem\u003c\/strong\u003e\u003c\/span\u003e\u003c\/th\u003e\n\u003cth style=\"text-align: center;\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eInterface (RS485)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eDefault: 9600, NONE, 8, 1\u003cbr\u003eOptions for band rate: 4800, 9600, 115200, 230400\u003cbr\u003eParity bit: NONE, EVEN, ODD\u003cbr\u003eData bits: 8\u003cbr\u003eStop bit(s): 1, 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003ePhysical Dimensions\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e79.6*58*110 (mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eInstallation\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eDIN rail mounting \u0026amp; Panel mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eStatus LEDs\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cstrong\u003ePOW:\u003c\/strong\u003e Steady on: Power supply is normal, Off: No power supply or abnormal power supply\u003cbr\u003e\u003cstrong\u003eWORK:\u003c\/strong\u003e Blinking: Power is on, and the device is ready. System is booted up and running\u003cbr\u003e\u003cstrong\u003eDO:\u003c\/strong\u003e Steady on: The channel output is activated\u003cbr\u003e\u003cstrong\u003eDI:\u003c\/strong\u003e Steady on: The channel is activated input signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003ePower\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2-pin socket, DC:12-24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eProtection\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eEMC Protection Level 3, IEC 61000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eWatchdog\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eHardware \u0026amp; Software watchdog\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eFlame Retardant Rating\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eV0, burning stops within 10 seconds on a vertical part allowing for drops of plastic that are not inflamed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eTemperature\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eOperation: -25℃ ~ +75℃\u003cbr\u003eStorage: -40℃ ~ +105℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eHumidity\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eOperation: 5%~95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eI\/O\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cstrong\u003eDI:\u003c\/strong\u003e Digital opto-isolated input (0 -2 V = low, 9 -36 V = high)\u003cbr\u003e\u003cstrong\u003eAI:\u003c\/strong\u003e Analog input 4-20mA\u003cbr\u003e\u003cstrong\u003eDO:\u003c\/strong\u003e Relays, endurance 100,000 operations.\u003cbr\u003eDC contacts rating @R (at resistive load) 3A \/ 30V DC.\u003cbr\u003eAC contacts rating @R (at resistive load) 3A \/ 250V AC, NO\u003cbr\u003e\u003cstrong\u003eAO:\u003c\/strong\u003e Analog output: voltage output (0-10V), current output (4-20mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eModbus Slave Address\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eRange: 1~255, Default: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"text-align: center;\"\u003e \u003c\/p\u003e\n\u003ch3 style=\"text-align: center;\"\u003eDOWNLOAD\u003c\/h3\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cstrong\u003eDocuments\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"width: 100%; height: 19.5938px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 70.1745%; height: 19.5938px;\"\u003e [User Manual] USR-IO0080\/8000\/0440\/4040\/0404 Manual\u003c\/td\u003e\n\u003ctd style=\"width: 29.4579%; text-align: right; height: 19.5938px;\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0014\/4313\/5560\/files\/566c67bb606301807c94c4f8bf37d32c.pdf?v=1751014111\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"PUSR","offers":[{"title":"IO4040","offer_id":49915513438525,"sku":"ELC8519","price":2349.99,"currency_code":"INR","in_stock":true},{"title":"IO0440","offer_id":49915513471293,"sku":"ELC8520","price":2349.99,"currency_code":"INR","in_stock":true},{"title":"IO0080","offer_id":50444578816317,"sku":"ELC8521","price":2349.99,"currency_code":"INR","in_stock":true},{"title":"IO8000","offer_id":50444578849085,"sku":"ELC8522","price":2349.99,"currency_code":"INR","in_stock":true},{"title":"IO0404","offer_id":49915513504061,"sku":"ELC8523","price":9049.99,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0014\/4313\/5560\/files\/USR-1.png?v=1737713724","url":"https:\/\/thinkrobotics.com\/ar\/products\/usr-io0080-8000-0440-4040-0404","provider":"Atlantis Robotics","version":"1.0","type":"link"}