TE CONNECTIVITY SENSORS Board Mount Pressure Sensors (Part Number: 1230-050A-3S)
Enhance your electronic systems with the TE CONNECTIVITY SENSORS 1230 series Board Mount Pressure Sensors, designed for high performance and long-term stability. These sensors are ideal for applications requiring precise pressure measurement with temperature compensation and reliable operation.
PC Board Mountable Pressure Sensor with 0-100 mV Output
Operates with Current Excitation
Supports Gage, Differential, and Absolute Pressure Types
Temperature Compensated from -20°C to +85°C using laser-trimmed resistors
Includes an external gain set resistor for pressure sensitivity normalization (interchangeability of ±1%)
Solid-state reliability with UltraStable™ die technology
Performance Specifications
Parameter
Min
Typ
Max
Units
Notes
Span
75
100
150
mV
Zero Pressure Output
-2
2
mV
Pressure Non Linearity
-0.1
±0.05
0.1
%Span
For 2 PSI, non-linearity is ±0.2%; for 5 PSI, ±0.5%
Pressure Hysteresis
-0.1
±0.01
0.1
%Span
Input Resistance
2200
4000
5800
Ω
Output Resistance
4200
Ω
Temperature Error – Span
-0.5
±0.3
0.5
%Span
Maximum error between -20°C and +85°C
Temperature Error – Zero
-0.5
±0.1
0.5
%Span
Temperature Coefficient – Resistance
0.15
%/°C
Thermal Hysteresis – Zero
±0.05
Short Term Stability (Offset & Span)
±0.05
%Span
Over 7 days with constant current and temperature
Long Term Stability (Offset & Span)
±0.1
%Span
Over one year with constant current and temperature
Supply Current
0.5
1.5
2.0
mA
Response Time (10% to 90%)
1.0
ms
Output Noise (10Hz to 1kHz)
1.0
µV p-p
Pressure Overload
3X Rated
Maximum for 100 psi device
Operating Temperature
-40
+125
°C
Storage Temperature
-50
+150
°C
Compensated Temperature Range
-20
+85
°C
Weight
3
grams
Application Areas
Medical Instruments
Altitude Measurement
Process Control
Factory Automation
Handheld Calibrators
Environmental Control
Additional Information
This sensor supports various pressure ranges from 0-15 to 0-100 psi, with multiple lead and tube configurations available. For voltage excitation options, refer to Model 1240. Ensure compatibility with non-corrosive dry gases such as silicon, Pyrex, RTV, gold, ceramic, nickel, and aluminum.
For more detailed specifications and application guidance, please refer to the full datasheet.
Note: The datasheet was not processed; please search the internet for the part number for more details.
Note: The product image displayed is a standard reference image. Actual product appearance may vary. For the most accurate and up-to-date representation, we recommend searching the part number online.
Use left/right arrows to navigate the slideshow or swipe left/right if using a mobile device
Choosing a selection results in a full page refresh.
Press the space key then arrow keys to make a selection.
Shopping Cart
{"id":10006898147645,"title":"1230-050A-3S","handle":"1230-050a-3s","description":"\u003ch3\u003eTE CONNECTIVITY SENSORS Board Mount Pressure Sensors (Part Number: 1230-050A-3S)\u003c\/h3\u003e\n\u003cp\u003eEnhance your electronic systems with the TE CONNECTIVITY SENSORS 1230 series Board Mount Pressure Sensors, designed for high performance and long-term stability. These sensors are ideal for applications requiring precise pressure measurement with temperature compensation and reliable operation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 1230-050A-3S\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e TE CONNECTIVITY SENSORS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin (COO):\u003c\/strong\u003e CN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit of Measure (UOM):\u003c\/strong\u003e EA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e Not specified\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Type:\u003c\/strong\u003e Dual-in-line\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDatasheet:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-tcs\/tcs-1230-050a-3s.pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePC Board Mountable Pressure Sensor with 0-100 mV Output\u003c\/li\u003e\n\u003cli\u003eOperates with Current Excitation\u003c\/li\u003e\n\u003cli\u003eSupports Gage, Differential, and Absolute Pressure Types\u003c\/li\u003e\n\u003cli\u003eTemperature Compensated from -20°C to +85°C using laser-trimmed resistors\u003c\/li\u003e\n\u003cli\u003eIncludes an external gain set resistor for pressure sensitivity normalization (interchangeability of ±1%)\u003c\/li\u003e\n\u003cli\u003eSolid-state reliability with UltraStable™ die technology\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePerformance Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eMin\u003c\/th\u003e\n\u003cth\u003eTyp\u003c\/th\u003e\n\u003cth\u003eMax\u003c\/th\u003e\n\u003cth\u003eUnits\u003c\/th\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpan\u003c\/td\u003e\n\u003ctd\u003e75\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003ctd\u003e150\u003c\/td\u003e\n\u003ctd\u003emV\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero Pressure Output\u003c\/td\u003e\n\u003ctd\u003e-2\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003emV\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Non Linearity\u003c\/td\u003e\n\u003ctd\u003e-0.1\u003c\/td\u003e\n\u003ctd\u003e±0.05\u003c\/td\u003e\n\u003ctd\u003e0.1\u003c\/td\u003e\n\u003ctd\u003e%Span\u003c\/td\u003e\n\u003ctd\u003eFor 2 PSI, non-linearity is ±0.2%; for 5 PSI, ±0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Hysteresis\u003c\/td\u003e\n\u003ctd\u003e-0.1\u003c\/td\u003e\n\u003ctd\u003e±0.01\u003c\/td\u003e\n\u003ctd\u003e0.1\u003c\/td\u003e\n\u003ctd\u003e%Span\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance\u003c\/td\u003e\n\u003ctd\u003e2200\u003c\/td\u003e\n\u003ctd\u003e4000\u003c\/td\u003e\n\u003ctd\u003e5800\u003c\/td\u003e\n\u003ctd\u003eΩ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Resistance\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e4200\u003c\/td\u003e\n\u003ctd\u003eΩ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Error – Span\u003c\/td\u003e\n\u003ctd\u003e-0.5\u003c\/td\u003e\n\u003ctd\u003e±0.3\u003c\/td\u003e\n\u003ctd\u003e0.5\u003c\/td\u003e\n\u003ctd\u003e%Span\u003c\/td\u003e\n\u003ctd\u003eMaximum error between -20°C and +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Error – Zero\u003c\/td\u003e\n\u003ctd\u003e-0.5\u003c\/td\u003e\n\u003ctd\u003e±0.1\u003c\/td\u003e\n\u003ctd\u003e0.5\u003c\/td\u003e\n\u003ctd\u003e%Span\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Coefficient – Resistance\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e0.15\u003c\/td\u003e\n\u003ctd\u003e%\/°C\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Hysteresis – Zero\u003c\/td\u003e\n\u003ctd\u003e±0.05\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Term Stability (Offset \u0026amp; Span)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e±0.05\u003c\/td\u003e\n\u003ctd\u003e%Span\u003c\/td\u003e\n\u003ctd\u003eOver 7 days with constant current and temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong Term Stability (Offset \u0026amp; Span)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e±0.1\u003c\/td\u003e\n\u003ctd\u003e%Span\u003c\/td\u003e\n\u003ctd\u003eOver one year with constant current and temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Current\u003c\/td\u003e\n\u003ctd\u003e0.5\u003c\/td\u003e\n\u003ctd\u003e1.5\u003c\/td\u003e\n\u003ctd\u003e2.0\u003c\/td\u003e\n\u003ctd\u003emA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time (10% to 90%)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e1.0\u003c\/td\u003e\n\u003ctd\u003ems\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Noise (10Hz to 1kHz)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e1.0\u003c\/td\u003e\n\u003ctd\u003eµV p-p\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Overload\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e3X Rated\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMaximum for 100 psi device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e+125\u003c\/td\u003e\n\u003ctd\u003e°C\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-50\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e+150\u003c\/td\u003e\n\u003ctd\u003e°C\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompensated Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-20\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e+85\u003c\/td\u003e\n\u003ctd\u003e°C\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e3\u003c\/td\u003e\n\u003ctd\u003egrams\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplication Areas\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMedical Instruments\u003c\/li\u003e\n\u003cli\u003eAltitude Measurement\u003c\/li\u003e\n\u003cli\u003eProcess Control\u003c\/li\u003e\n\u003cli\u003eFactory Automation\u003c\/li\u003e\n\u003cli\u003eHandheld Calibrators\u003c\/li\u003e\n\u003cli\u003eEnvironmental Control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdditional Information\u003c\/h3\u003e\n\u003cp\u003eThis sensor supports various pressure ranges from 0-15 to 0-100 psi, with multiple lead and tube configurations available. For voltage excitation options, refer to Model 1240. Ensure compatibility with non-corrosive dry gases such as silicon, Pyrex, RTV, gold, ceramic, nickel, and aluminum.\u003c\/p\u003e\n\u003cp\u003eFor more detailed specifications and application guidance, please refer to the \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-tcs\/tcs-1230-050a-3s.pdf\" target=\"_blank\"\u003efull datasheet\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: The datasheet was not processed; please search the internet for the part number for more details.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNote: The product image displayed is a standard reference image. Actual product appearance may vary. For the most accurate and up-to-date representation, we recommend searching the part number online.\u003c\/strong\u003e\u003c\/p\u003e","published_at":"2025-08-07T09:06:03+05:30","created_at":"2025-08-07T09:06:03+05:30","vendor":"Waldom Electonics","type":"Sensors\/Transducers","tags":["STD_IMG","WLDM"],"price":252097,"price_min":252097,"price_max":252097,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50558342988093,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"1230-050A-3S","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"1230-050A-3S","public_title":null,"options":["Default Title"],"price":252097,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"1230-050A-3S","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/fbe811dc-181f-41c1-ab5a-dc3410446d1d_fd1f56a6-d309-47b1-ba24-ed91a8db4bcf.jpg?v=1754537763"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/fbe811dc-181f-41c1-ab5a-dc3410446d1d_fd1f56a6-d309-47b1-ba24-ed91a8db4bcf.jpg?v=1754537763","options":["Title"],"media":[{"alt":null,"id":45708158533949,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1024,"width":1024,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/fbe811dc-181f-41c1-ab5a-dc3410446d1d_fd1f56a6-d309-47b1-ba24-ed91a8db4bcf.jpg?v=1754537763"},"aspect_ratio":1.0,"height":1024,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/fbe811dc-181f-41c1-ab5a-dc3410446d1d_fd1f56a6-d309-47b1-ba24-ed91a8db4bcf.jpg?v=1754537763","width":1024}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eTE CONNECTIVITY SENSORS Board Mount Pressure Sensors (Part Number: 1230-050A-3S)\u003c\/h3\u003e\n\u003cp\u003eEnhance your electronic systems with the TE CONNECTIVITY SENSORS 1230 series Board Mount Pressure Sensors, designed for high performance and long-term stability. These sensors are ideal for applications requiring precise pressure measurement with temperature compensation and reliable operation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 1230-050A-3S\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e TE CONNECTIVITY SENSORS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin (COO):\u003c\/strong\u003e CN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit of Measure (UOM):\u003c\/strong\u003e EA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e Not specified\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Type:\u003c\/strong\u003e Dual-in-line\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDatasheet:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-tcs\/tcs-1230-050a-3s.pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePC Board Mountable Pressure Sensor with 0-100 mV Output\u003c\/li\u003e\n\u003cli\u003eOperates with Current Excitation\u003c\/li\u003e\n\u003cli\u003eSupports Gage, Differential, and Absolute Pressure Types\u003c\/li\u003e\n\u003cli\u003eTemperature Compensated from -20°C to +85°C using laser-trimmed resistors\u003c\/li\u003e\n\u003cli\u003eIncludes an external gain set resistor for pressure sensitivity normalization (interchangeability of ±1%)\u003c\/li\u003e\n\u003cli\u003eSolid-state reliability with UltraStable™ die technology\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePerformance Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eMin\u003c\/th\u003e\n\u003cth\u003eTyp\u003c\/th\u003e\n\u003cth\u003eMax\u003c\/th\u003e\n\u003cth\u003eUnits\u003c\/th\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpan\u003c\/td\u003e\n\u003ctd\u003e75\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003ctd\u003e150\u003c\/td\u003e\n\u003ctd\u003emV\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero Pressure Output\u003c\/td\u003e\n\u003ctd\u003e-2\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003emV\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Non Linearity\u003c\/td\u003e\n\u003ctd\u003e-0.1\u003c\/td\u003e\n\u003ctd\u003e±0.05\u003c\/td\u003e\n\u003ctd\u003e0.1\u003c\/td\u003e\n\u003ctd\u003e%Span\u003c\/td\u003e\n\u003ctd\u003eFor 2 PSI, non-linearity is ±0.2%; for 5 PSI, ±0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Hysteresis\u003c\/td\u003e\n\u003ctd\u003e-0.1\u003c\/td\u003e\n\u003ctd\u003e±0.01\u003c\/td\u003e\n\u003ctd\u003e0.1\u003c\/td\u003e\n\u003ctd\u003e%Span\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance\u003c\/td\u003e\n\u003ctd\u003e2200\u003c\/td\u003e\n\u003ctd\u003e4000\u003c\/td\u003e\n\u003ctd\u003e5800\u003c\/td\u003e\n\u003ctd\u003eΩ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Resistance\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e4200\u003c\/td\u003e\n\u003ctd\u003eΩ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Error – Span\u003c\/td\u003e\n\u003ctd\u003e-0.5\u003c\/td\u003e\n\u003ctd\u003e±0.3\u003c\/td\u003e\n\u003ctd\u003e0.5\u003c\/td\u003e\n\u003ctd\u003e%Span\u003c\/td\u003e\n\u003ctd\u003eMaximum error between -20°C and +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Error – Zero\u003c\/td\u003e\n\u003ctd\u003e-0.5\u003c\/td\u003e\n\u003ctd\u003e±0.1\u003c\/td\u003e\n\u003ctd\u003e0.5\u003c\/td\u003e\n\u003ctd\u003e%Span\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Coefficient – Resistance\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e0.15\u003c\/td\u003e\n\u003ctd\u003e%\/°C\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Hysteresis – Zero\u003c\/td\u003e\n\u003ctd\u003e±0.05\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Term Stability (Offset \u0026amp; Span)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e±0.05\u003c\/td\u003e\n\u003ctd\u003e%Span\u003c\/td\u003e\n\u003ctd\u003eOver 7 days with constant current and temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong Term Stability (Offset \u0026amp; Span)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e±0.1\u003c\/td\u003e\n\u003ctd\u003e%Span\u003c\/td\u003e\n\u003ctd\u003eOver one year with constant current and temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Current\u003c\/td\u003e\n\u003ctd\u003e0.5\u003c\/td\u003e\n\u003ctd\u003e1.5\u003c\/td\u003e\n\u003ctd\u003e2.0\u003c\/td\u003e\n\u003ctd\u003emA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time (10% to 90%)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e1.0\u003c\/td\u003e\n\u003ctd\u003ems\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Noise (10Hz to 1kHz)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e1.0\u003c\/td\u003e\n\u003ctd\u003eµV p-p\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Overload\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e3X Rated\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMaximum for 100 psi device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e+125\u003c\/td\u003e\n\u003ctd\u003e°C\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-50\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e+150\u003c\/td\u003e\n\u003ctd\u003e°C\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompensated Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-20\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e+85\u003c\/td\u003e\n\u003ctd\u003e°C\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e3\u003c\/td\u003e\n\u003ctd\u003egrams\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplication Areas\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMedical Instruments\u003c\/li\u003e\n\u003cli\u003eAltitude Measurement\u003c\/li\u003e\n\u003cli\u003eProcess Control\u003c\/li\u003e\n\u003cli\u003eFactory Automation\u003c\/li\u003e\n\u003cli\u003eHandheld Calibrators\u003c\/li\u003e\n\u003cli\u003eEnvironmental Control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdditional Information\u003c\/h3\u003e\n\u003cp\u003eThis sensor supports various pressure ranges from 0-15 to 0-100 psi, with multiple lead and tube configurations available. For voltage excitation options, refer to Model 1240. Ensure compatibility with non-corrosive dry gases such as silicon, Pyrex, RTV, gold, ceramic, nickel, and aluminum.\u003c\/p\u003e\n\u003cp\u003eFor more detailed specifications and application guidance, please refer to the \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-tcs\/tcs-1230-050a-3s.pdf\" target=\"_blank\"\u003efull datasheet\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: The datasheet was not processed; please search the internet for the part number for more details.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNote: The product image displayed is a standard reference image. Actual product appearance may vary. For the most accurate and up-to-date representation, we recommend searching the part number online.\u003c\/strong\u003e\u003c\/p\u003e"}