CARLO GAVAZZI EM50DINAV53HRSX ENERGY METER 3-PHASE CLASS 05S
The CARLO GAVAZZI EM50 is a versatile energy analyzer designed for accurate measurement of electrical variables in 1-phase, 2-phase, and 3-phase systems. Suitable for DIN-rail mounting, this device features a backlit LCD display for clear data visualization and supports multiple communication protocols including Modbus RTU and BACnet MS/TP, enabling seamless integration into building and industrial automation systems.
Flexible Installation: Compatible with single-phase, two-phase, three-phase, and wild-leg systems with various voltage levels used in USA and Canada.
Extended Energy Measurements: Measures imported/exported kWh, reactive power (kvarh), and multi-tariff energy consumption across four tariffs.
Communication & Outputs: Equipped with serial communication ports (Modbus RTU, BACnet MS/TP), static pulse output, relay for alarms or remote control, and supports direct voltage connection up to 600 V L-L.
Legal Metrology: Measurement Canada approved version available for legal metrology applications in Canada.
Quick Configuration: Free proprietary UCS software simplifies system setup and configuration.
Event & Energy Log Management: Tracks current and previous months' energy data, resets, alarms, and configuration changes.
Technical Specifications
Protection Degree
Front: IP40, Terminals: IP20
Terminals
Screw terminals, Voltage and current: max 4 mm2; min 0.2 mm2
Overvoltage Category
Cat. III
Pollution Degree
2
Noise Rejection (CMRR)
100 dB, 45-65 Hz
Mounting
DIN rail
Weight (including packaging)
340 g
Environmental & Electrical Specifications
Operating Temperature
-25 to +75 °C / -13 to +167 °F (standard), -20 to +53 °C / -4 to +127 °F (Measurement Canada version)
Storage Temperature
-40 to +85 °C / -40 to +185 °F
Measuring Inputs
Up to 600 V to ground, direct or via VT
Relay Output
2 kV
Static Output
2.5 kV
Communication Port
3 kV
Auxiliary Power Supply
2 kV
Certifications & Compliance
RoHs Compliant: Yes
Standards & Directives: EN61000-6-3/ EN61000-6-2, EN 61010-1, EN 62053-22, IEC 62053-23
Measurement Canada Approval: LMB-EG-07
ECCN: EAR99
For detailed technical data, please refer to the EM50 Datasheet. The product is packaged in a box and is available as a single unit (EA).
Part Number: EM50DINAV53HRSX | Manufacturer: CARLO GAVAZZI | COO: CA | UOM: EA | ECCN: EAR99 | Package Type: BOX
Note: Datasheet was not processed, please search the internet for the part number for more details.
Use left/right arrows to navigate the slideshow or swipe left/right if using a mobile device
Choosing a selection results in a full page refresh.
Press the space key then arrow keys to make a selection.
Shopping Cart
{"id":10022004523325,"title":"EM50DINAV53HRSX","handle":"em50dinav53hrsx","description":"\u003ch3\u003eCARLO GAVAZZI EM50DINAV53HRSX ENERGY METER 3-PHASE CLASS 05S\u003c\/h3\u003e\n\u003cp\u003eThe CARLO GAVAZZI EM50 is a versatile energy analyzer designed for accurate measurement of electrical variables in 1-phase, 2-phase, and 3-phase systems. Suitable for DIN-rail mounting, this device features a backlit LCD display for clear data visualization and supports multiple communication protocols including Modbus RTU and BACnet MS\/TP, enabling seamless integration into building and industrial automation systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Installation:\u003c\/strong\u003e Compatible with single-phase, two-phase, three-phase, and wild-leg systems with various voltage levels used in USA and Canada.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended Energy Measurements:\u003c\/strong\u003e Measures imported\/exported kWh, reactive power (kvarh), and multi-tariff energy consumption across four tariffs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication \u0026amp; Outputs:\u003c\/strong\u003e Equipped with serial communication ports (Modbus RTU, BACnet MS\/TP), static pulse output, relay for alarms or remote control, and supports direct voltage connection up to 600 V L-L.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLegal Metrology:\u003c\/strong\u003e Measurement Canada approved version available for legal metrology applications in Canada.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuick Configuration:\u003c\/strong\u003e Free proprietary UCS software simplifies system setup and configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvent \u0026amp; Energy Log Management:\u003c\/strong\u003e Tracks current and previous months' energy data, resets, alarms, and configuration changes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection Degree\u003c\/th\u003e\n\u003cth\u003eFront: IP40, Terminals: IP20\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminals\u003c\/th\u003e\n\u003cth\u003eScrew terminals, Voltage and current: max 4 mm\u003csup\u003e2\u003c\/sup\u003e; min 0.2 mm\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOvervoltage Category\u003c\/th\u003e\n\u003cth\u003eCat. III\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePollution Degree\u003c\/th\u003e\n\u003cth\u003e2\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNoise Rejection (CMRR)\u003c\/th\u003e\n\u003cth\u003e100 dB, 45-65 Hz\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003cth\u003eDIN rail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight (including packaging)\u003c\/th\u003e\n\u003cth\u003e340 g\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEnvironmental \u0026amp; Electrical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Temperature\u003c\/th\u003e\n\u003cth\u003e-25 to +75 °C \/ -13 to +167 °F (standard), -20 to +53 °C \/ -4 to +127 °F (Measurement Canada version)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003cth\u003e-40 to +85 °C \/ -40 to +185 °F\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasuring Inputs\u003c\/th\u003e\n\u003cth\u003eUp to 600 V to ground, direct or via VT\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelay Output\u003c\/th\u003e\n\u003cth\u003e2 kV\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStatic Output\u003c\/th\u003e\n\u003cth\u003e2.5 kV\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication Port\u003c\/th\u003e\n\u003cth\u003e3 kV\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Power Supply\u003c\/th\u003e\n\u003cth\u003e2 kV\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCertifications \u0026amp; Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRoHs Compliant: Yes\u003c\/li\u003e\n\u003cli\u003eStandards \u0026amp; Directives: EN61000-6-3\/ EN61000-6-2, EN 61010-1, EN 62053-22, IEC 62053-23\u003c\/li\u003e\n\u003cli\u003eMeasurement Canada Approval: LMB-EG-07\u003c\/li\u003e\n\u003cli\u003eECCN: EAR99\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor detailed technical data, please refer to the \u003ca href=\"https:\/\/www.gavazzionline.com\/pdf\/EM50_DS_ENG_2020_05_12.pdf\" target=\"_blank\"\u003eEM50 Datasheet\u003c\/a\u003e. The product is packaged in a box and is available as a single unit (EA).\u003c\/p\u003e\n\u003cp\u003ePart Number: EM50DINAV53HRSX | Manufacturer: CARLO GAVAZZI | COO: CA | UOM: EA | ECCN: EAR99 | Package Type: BOX\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: Datasheet was not processed, please search the internet for the part number for more details.\u003c\/em\u003e\u003c\/p\u003e","published_at":"2025-08-13T01:53:35+05:30","created_at":"2025-08-13T01:53:35+05:30","vendor":"Waldom Electonics","type":"","tags":["CARLO","IMPORT_CSV","WLDM"],"price":3759835,"price_min":3759835,"price_max":3759835,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50613745713469,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"EM50DINAV53HRSX","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"EM50DINAV53HRSX","public_title":null,"options":["Default Title"],"price":3759835,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"EM50DINAV53HRSX","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/54923481.jpg?v=1755030217"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/54923481.jpg?v=1755030217","options":["Title"],"media":[{"alt":null,"id":45808635150653,"position":1,"preview_image":{"aspect_ratio":1.0,"height":300,"width":300,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/54923481.jpg?v=1755030217"},"aspect_ratio":1.0,"height":300,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/54923481.jpg?v=1755030217","width":300}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eCARLO GAVAZZI EM50DINAV53HRSX ENERGY METER 3-PHASE CLASS 05S\u003c\/h3\u003e\n\u003cp\u003eThe CARLO GAVAZZI EM50 is a versatile energy analyzer designed for accurate measurement of electrical variables in 1-phase, 2-phase, and 3-phase systems. Suitable for DIN-rail mounting, this device features a backlit LCD display for clear data visualization and supports multiple communication protocols including Modbus RTU and BACnet MS\/TP, enabling seamless integration into building and industrial automation systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Installation:\u003c\/strong\u003e Compatible with single-phase, two-phase, three-phase, and wild-leg systems with various voltage levels used in USA and Canada.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended Energy Measurements:\u003c\/strong\u003e Measures imported\/exported kWh, reactive power (kvarh), and multi-tariff energy consumption across four tariffs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication \u0026amp; Outputs:\u003c\/strong\u003e Equipped with serial communication ports (Modbus RTU, BACnet MS\/TP), static pulse output, relay for alarms or remote control, and supports direct voltage connection up to 600 V L-L.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLegal Metrology:\u003c\/strong\u003e Measurement Canada approved version available for legal metrology applications in Canada.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuick Configuration:\u003c\/strong\u003e Free proprietary UCS software simplifies system setup and configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvent \u0026amp; Energy Log Management:\u003c\/strong\u003e Tracks current and previous months' energy data, resets, alarms, and configuration changes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection Degree\u003c\/th\u003e\n\u003cth\u003eFront: IP40, Terminals: IP20\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminals\u003c\/th\u003e\n\u003cth\u003eScrew terminals, Voltage and current: max 4 mm\u003csup\u003e2\u003c\/sup\u003e; min 0.2 mm\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOvervoltage Category\u003c\/th\u003e\n\u003cth\u003eCat. III\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePollution Degree\u003c\/th\u003e\n\u003cth\u003e2\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNoise Rejection (CMRR)\u003c\/th\u003e\n\u003cth\u003e100 dB, 45-65 Hz\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003cth\u003eDIN rail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight (including packaging)\u003c\/th\u003e\n\u003cth\u003e340 g\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEnvironmental \u0026amp; Electrical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Temperature\u003c\/th\u003e\n\u003cth\u003e-25 to +75 °C \/ -13 to +167 °F (standard), -20 to +53 °C \/ -4 to +127 °F (Measurement Canada version)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003cth\u003e-40 to +85 °C \/ -40 to +185 °F\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasuring Inputs\u003c\/th\u003e\n\u003cth\u003eUp to 600 V to ground, direct or via VT\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelay Output\u003c\/th\u003e\n\u003cth\u003e2 kV\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStatic Output\u003c\/th\u003e\n\u003cth\u003e2.5 kV\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication Port\u003c\/th\u003e\n\u003cth\u003e3 kV\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Power Supply\u003c\/th\u003e\n\u003cth\u003e2 kV\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCertifications \u0026amp; Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRoHs Compliant: Yes\u003c\/li\u003e\n\u003cli\u003eStandards \u0026amp; Directives: EN61000-6-3\/ EN61000-6-2, EN 61010-1, EN 62053-22, IEC 62053-23\u003c\/li\u003e\n\u003cli\u003eMeasurement Canada Approval: LMB-EG-07\u003c\/li\u003e\n\u003cli\u003eECCN: EAR99\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor detailed technical data, please refer to the \u003ca href=\"https:\/\/www.gavazzionline.com\/pdf\/EM50_DS_ENG_2020_05_12.pdf\" target=\"_blank\"\u003eEM50 Datasheet\u003c\/a\u003e. The product is packaged in a box and is available as a single unit (EA).\u003c\/p\u003e\n\u003cp\u003ePart Number: EM50DINAV53HRSX | Manufacturer: CARLO GAVAZZI | COO: CA | UOM: EA | ECCN: EAR99 | Package Type: BOX\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: Datasheet was not processed, please search the internet for the part number for more details.\u003c\/em\u003e\u003c\/p\u003e"}
Unfortunately I havent tested the 5G, Only difficult part was connecting antennas. But everything is good, by default it runs on Qualcom's QMI mode, Had to switch to MBIM and it works good with Windows. Planning to run with OpenWRT soon.