CARLO GAVAZZI 115-230V CURRENT LEVEL RELAY (Part Number: PIB01CB235A)
Enhance your electrical monitoring systems with the CARLO GAVAZZI 115-230V Current Level Relay, designed for precise current measurement and reliable operation in industrial applications. This relay is suitable for monitoring both AC and DC loads, providing flexible configuration options for various current ranges.
Product Features
TRMS AC/DC over or under current measurement through internal shunt
Selectable measuring range via DIP-switches, from 0.1 mA to 10 A
Adjustable current on relative scale for precise calibration
Adjustable hysteresis for stable operation
Programmable delay function (0.1 to 30 seconds)
Programmable latching or inhibit at set level
Output: 8 A SPDT relay, Normally De-energized or Normally Energized, selectable
Mounting options include DIN-rail (DIB01) or plug-in module (PIB01)
Housing options: 22.5 mm Euronorm (DIB01) or 36 mm plug-in module (PIB01)
LED indicators for relay status, alarm, and power supply
Galvanically separated power supply for enhanced safety
Technical Specifications
Measuring Range
Housing Type
Output
Supply Voltage
0.1 to 5 mA AC/DC
DIN-rail (DIB01), Plug-in (PIB01)
SPDT relay, 8 A
115/230 VAC or 24-48 VAC/DC
1 to 50 mA AC/DC
DIN-rail (DIB01), Plug-in (PIB01)
SPDT relay, 8 A
115/230 VAC or 24-48 VAC/DC
10 to 500 mA AC/DC
DIN-rail (DIB01), Plug-in (PIB01)
SPDT relay, 8 A
115/230 VAC or 24-48 VAC/DC
0.1 to 5 A AC/DC
DIN-rail (DIB01), Plug-in (PIB01)
SPDT relay, 8 A
115/230 VAC or 24-48 VAC/DC
1 to 10 A AC/DC
DIN-rail (DIB01), Plug-in (PIB01)
SPDT relay, 8 A
115/230 VAC or 24-48 VAC/DC
Input and Power Supply
Measuring ranges with internal resistance: from 0.5 Ω to 3 mΩ depending on current range
Max. current for 1 second: up to 50 A for 10 A range
Power supply options: 115/230 VAC ±15% or 24-48 VAC/DC ±15%
Overvoltage category III, insulated connection terminals
Operation Modes
The relay monitors both AC and DC over or under current via internal shunt. It features latch and inhibit functions, adjustable delay, hysteresis, and LED indicators for status. The relay operates when the measured current exceeds or drops below the set level for the configured delay time, with options for latch operation to maintain relay state until reset.
Dimensions
Housing dimensions vary based on mounting type, with detailed specifications available in the datasheet.
Additional Information
For detailed wiring diagrams, operation modes, and configuration settings, please refer to the datasheet.
Part Number: PIB01CB235A Manufacturer: CARLO GAVAZZI Country of Origin: IT Unit of Measure: EA ECCN: EAR99 Package Type: BOX
Datasheet was not processed please search the internet for the part number for more details.
Use left/right arrows to navigate the slideshow or swipe left/right if using a mobile device
Choosing a selection results in a full page refresh.
Press the space key then arrow keys to make a selection.
Shopping Cart
{"id":10013927440701,"title":"PIB01CB235A","handle":"pib01cb235a","description":"\u003ch3\u003eCARLO GAVAZZI 115-230V CURRENT LEVEL RELAY (Part Number: PIB01CB235A)\u003c\/h3\u003e\n\u003cp\u003eEnhance your electrical monitoring systems with the CARLO GAVAZZI 115-230V Current Level Relay, designed for precise current measurement and reliable operation in industrial applications. This relay is suitable for monitoring both AC and DC loads, providing flexible configuration options for various current ranges.\u003c\/p\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eTRMS AC\/DC over or under current measurement through internal shunt\u003c\/li\u003e\n \u003cli\u003eSelectable measuring range via DIP-switches, from 0.1 mA to 10 A\u003c\/li\u003e\n \u003cli\u003eAdjustable current on relative scale for precise calibration\u003c\/li\u003e\n \u003cli\u003eAdjustable hysteresis for stable operation\u003c\/li\u003e\n \u003cli\u003eProgrammable delay function (0.1 to 30 seconds)\u003c\/li\u003e\n \u003cli\u003eProgrammable latching or inhibit at set level\u003c\/li\u003e\n \u003cli\u003eOutput: 8 A SPDT relay, Normally De-energized or Normally Energized, selectable\u003c\/li\u003e\n \u003cli\u003eMounting options include DIN-rail (DIB01) or plug-in module (PIB01)\u003c\/li\u003e\n \u003cli\u003eHousing options: 22.5 mm Euronorm (DIB01) or 36 mm plug-in module (PIB01)\u003c\/li\u003e\n \u003cli\u003eLED indicators for relay status, alarm, and power supply\u003c\/li\u003e\n \u003cli\u003eGalvanically separated power supply for enhanced safety\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n \u003cthead\u003e\n \u003ctr\u003e\n \u003cth\u003eMeasuring Range\u003c\/th\u003e\n \u003cth\u003eHousing Type\u003c\/th\u003e\n \u003cth\u003eOutput\u003c\/th\u003e\n \u003cth\u003eSupply Voltage\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003c\/thead\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd\u003e0.1 to 5 mA AC\/DC\u003c\/td\u003e\n \u003ctd\u003eDIN-rail (DIB01), Plug-in (PIB01)\u003c\/td\u003e\n \u003ctd\u003eSPDT relay, 8 A\u003c\/td\u003e\n \u003ctd\u003e115\/230 VAC or 24-48 VAC\/DC\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e1 to 50 mA AC\/DC\u003c\/td\u003e\n \u003ctd\u003eDIN-rail (DIB01), Plug-in (PIB01)\u003c\/td\u003e\n \u003ctd\u003eSPDT relay, 8 A\u003c\/td\u003e\n \u003ctd\u003e115\/230 VAC or 24-48 VAC\/DC\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e10 to 500 mA AC\/DC\u003c\/td\u003e\n \u003ctd\u003eDIN-rail (DIB01), Plug-in (PIB01)\u003c\/td\u003e\n \u003ctd\u003eSPDT relay, 8 A\u003c\/td\u003e\n \u003ctd\u003e115\/230 VAC or 24-48 VAC\/DC\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e0.1 to 5 A AC\/DC\u003c\/td\u003e\n \u003ctd\u003eDIN-rail (DIB01), Plug-in (PIB01)\u003c\/td\u003e\n \u003ctd\u003eSPDT relay, 8 A\u003c\/td\u003e\n \u003ctd\u003e115\/230 VAC or 24-48 VAC\/DC\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e1 to 10 A AC\/DC\u003c\/td\u003e\n \u003ctd\u003eDIN-rail (DIB01), Plug-in (PIB01)\u003c\/td\u003e\n \u003ctd\u003eSPDT relay, 8 A\u003c\/td\u003e\n \u003ctd\u003e115\/230 VAC or 24-48 VAC\/DC\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInput and Power Supply\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eMeasuring ranges with internal resistance: from 0.5 Ω to 3 mΩ depending on current range\u003c\/li\u003e\n \u003cli\u003eMax. current for 1 second: up to 50 A for 10 A range\u003c\/li\u003e\n \u003cli\u003ePower supply options: 115\/230 VAC ±15% or 24-48 VAC\/DC ±15%\u003c\/li\u003e\n \u003cli\u003eOvervoltage category III, insulated connection terminals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOperation Modes\u003c\/h3\u003e\n\u003cp\u003eThe relay monitors both AC and DC over or under current via internal shunt. It features latch and inhibit functions, adjustable delay, hysteresis, and LED indicators for status. The relay operates when the measured current exceeds or drops below the set level for the configured delay time, with options for latch operation to maintain relay state until reset.\u003c\/p\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cp\u003eHousing dimensions vary based on mounting type, with detailed specifications available in the datasheet.\u003c\/p\u003e\n\u003ch3\u003eAdditional Information\u003c\/h3\u003e\n\u003cp\u003eFor detailed wiring diagrams, operation modes, and configuration settings, please refer to the \u003ca href=\"https:\/\/gavazziautomation.com\/images\/PIM\/DATASHEET\/ENG\/DIB01CB%20DS%20ENG%20270710.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003edatasheet\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e PIB01CB235A\u003cbr\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e CARLO GAVAZZI\u003cbr\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e IT\u003cbr\u003e\n\u003cstrong\u003eUnit of Measure:\u003c\/strong\u003e EA\u003cbr\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e EAR99\u003cbr\u003e\n\u003cstrong\u003ePackage Type:\u003c\/strong\u003e BOX\u003c\/p\u003e\n\u003cp\u003eDatasheet was not processed please search the internet for the part number for more details.\u003c\/p\u003e","published_at":"2025-08-10T23:57:32+05:30","created_at":"2025-08-10T23:57:32+05:30","vendor":"Waldom Electonics","type":"","tags":["230V","CARLO","IMPORT_CSV","Relay","WLDM"],"price":1859891,"price_min":1859891,"price_max":1859891,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50579284099389,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"PIB01CB235A","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"PIB01CB235A","public_title":null,"options":["Default Title"],"price":1859891,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"PIB01CB235A","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/11057387.jpg?v=1754850454"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/11057387.jpg?v=1754850454","options":["Title"],"media":[{"alt":null,"id":45767090471229,"position":1,"preview_image":{"aspect_ratio":1.0,"height":400,"width":400,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/11057387.jpg?v=1754850454"},"aspect_ratio":1.0,"height":400,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/11057387.jpg?v=1754850454","width":400}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eCARLO GAVAZZI 115-230V CURRENT LEVEL RELAY (Part Number: PIB01CB235A)\u003c\/h3\u003e\n\u003cp\u003eEnhance your electrical monitoring systems with the CARLO GAVAZZI 115-230V Current Level Relay, designed for precise current measurement and reliable operation in industrial applications. This relay is suitable for monitoring both AC and DC loads, providing flexible configuration options for various current ranges.\u003c\/p\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eTRMS AC\/DC over or under current measurement through internal shunt\u003c\/li\u003e\n \u003cli\u003eSelectable measuring range via DIP-switches, from 0.1 mA to 10 A\u003c\/li\u003e\n \u003cli\u003eAdjustable current on relative scale for precise calibration\u003c\/li\u003e\n \u003cli\u003eAdjustable hysteresis for stable operation\u003c\/li\u003e\n \u003cli\u003eProgrammable delay function (0.1 to 30 seconds)\u003c\/li\u003e\n \u003cli\u003eProgrammable latching or inhibit at set level\u003c\/li\u003e\n \u003cli\u003eOutput: 8 A SPDT relay, Normally De-energized or Normally Energized, selectable\u003c\/li\u003e\n \u003cli\u003eMounting options include DIN-rail (DIB01) or plug-in module (PIB01)\u003c\/li\u003e\n \u003cli\u003eHousing options: 22.5 mm Euronorm (DIB01) or 36 mm plug-in module (PIB01)\u003c\/li\u003e\n \u003cli\u003eLED indicators for relay status, alarm, and power supply\u003c\/li\u003e\n \u003cli\u003eGalvanically separated power supply for enhanced safety\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n \u003cthead\u003e\n \u003ctr\u003e\n \u003cth\u003eMeasuring Range\u003c\/th\u003e\n \u003cth\u003eHousing Type\u003c\/th\u003e\n \u003cth\u003eOutput\u003c\/th\u003e\n \u003cth\u003eSupply Voltage\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003c\/thead\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd\u003e0.1 to 5 mA AC\/DC\u003c\/td\u003e\n \u003ctd\u003eDIN-rail (DIB01), Plug-in (PIB01)\u003c\/td\u003e\n \u003ctd\u003eSPDT relay, 8 A\u003c\/td\u003e\n \u003ctd\u003e115\/230 VAC or 24-48 VAC\/DC\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e1 to 50 mA AC\/DC\u003c\/td\u003e\n \u003ctd\u003eDIN-rail (DIB01), Plug-in (PIB01)\u003c\/td\u003e\n \u003ctd\u003eSPDT relay, 8 A\u003c\/td\u003e\n \u003ctd\u003e115\/230 VAC or 24-48 VAC\/DC\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e10 to 500 mA AC\/DC\u003c\/td\u003e\n \u003ctd\u003eDIN-rail (DIB01), Plug-in (PIB01)\u003c\/td\u003e\n \u003ctd\u003eSPDT relay, 8 A\u003c\/td\u003e\n \u003ctd\u003e115\/230 VAC or 24-48 VAC\/DC\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e0.1 to 5 A AC\/DC\u003c\/td\u003e\n \u003ctd\u003eDIN-rail (DIB01), Plug-in (PIB01)\u003c\/td\u003e\n \u003ctd\u003eSPDT relay, 8 A\u003c\/td\u003e\n \u003ctd\u003e115\/230 VAC or 24-48 VAC\/DC\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e1 to 10 A AC\/DC\u003c\/td\u003e\n \u003ctd\u003eDIN-rail (DIB01), Plug-in (PIB01)\u003c\/td\u003e\n \u003ctd\u003eSPDT relay, 8 A\u003c\/td\u003e\n \u003ctd\u003e115\/230 VAC or 24-48 VAC\/DC\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInput and Power Supply\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eMeasuring ranges with internal resistance: from 0.5 Ω to 3 mΩ depending on current range\u003c\/li\u003e\n \u003cli\u003eMax. current for 1 second: up to 50 A for 10 A range\u003c\/li\u003e\n \u003cli\u003ePower supply options: 115\/230 VAC ±15% or 24-48 VAC\/DC ±15%\u003c\/li\u003e\n \u003cli\u003eOvervoltage category III, insulated connection terminals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOperation Modes\u003c\/h3\u003e\n\u003cp\u003eThe relay monitors both AC and DC over or under current via internal shunt. It features latch and inhibit functions, adjustable delay, hysteresis, and LED indicators for status. The relay operates when the measured current exceeds or drops below the set level for the configured delay time, with options for latch operation to maintain relay state until reset.\u003c\/p\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cp\u003eHousing dimensions vary based on mounting type, with detailed specifications available in the datasheet.\u003c\/p\u003e\n\u003ch3\u003eAdditional Information\u003c\/h3\u003e\n\u003cp\u003eFor detailed wiring diagrams, operation modes, and configuration settings, please refer to the \u003ca href=\"https:\/\/gavazziautomation.com\/images\/PIM\/DATASHEET\/ENG\/DIB01CB%20DS%20ENG%20270710.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003edatasheet\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e PIB01CB235A\u003cbr\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e CARLO GAVAZZI\u003cbr\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e IT\u003cbr\u003e\n\u003cstrong\u003eUnit of Measure:\u003c\/strong\u003e EA\u003cbr\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e EAR99\u003cbr\u003e\n\u003cstrong\u003ePackage Type:\u003c\/strong\u003e BOX\u003c\/p\u003e\n\u003cp\u003eDatasheet was not processed please search the internet for the part number for more details.\u003c\/p\u003e"}
Unfortunately I havent tested the 5G, Only difficult part was connecting antennas. But everything is good, by default it runs on Qualcom's QMI mode, Had to switch to MBIM and it works good with Windows. Planning to run with OpenWRT soon.