CARLO GAVAZZI SB2WEB24 Specialty Controllers SMART-BUILDING WEB REV.1
The SB2WEB24 is a high-performance BACnet controller designed for HVAC and lighting systems in smart building automation. Manufactured by CARLO GAVAZZI in Italy, this specialty controller offers advanced features for building management, energy data logging, and remote control capabilities.
Key Features
BACnet/IP controller with automatic creation of BACnet objects for Dupline® and Energy Meter data points
BTL certified for reliable building automation integration
Embedded Linux operating system with a micro PC architecture
Web-server for easy remote access and configuration
Two RS485 ports supporting Modbus TCP/RTU communication
One Ethernet port for LAN connectivity
Two USB 2.0 ports for programming and data transfer
Internal data storage capable of retaining data for up to 30 years with 4GB memory
Data logging, scheduling, alarms, and control of lighting, blinds, and temperature
Configurable via user-friendly software, compatible with spreadsheets for data export
Modular and scalable system architecture for precise sizing and expansion
Remote control and automatic actions for efficient building management
Technical Specifications
Element
Component
Function
Ethernet port
Web interface display and remote data transmission
USB Port (Host)
IP address programming
Information LED
Status indication for bus connection, USB, COM ports, and power
Micro SD memory card slot
IP address programming
Mini-USB port (Device)
PC connection for web interface access and backup
RS485 COM1 port
Connecting Modbus devices
RS485 COM2 port
Connecting Modbus devices
Power terminals
Power supply connection
Local bus ports
Connecting SH2DSP24, SH2MCG24, SH2WBU230N modules
Power Supply & Environmental Conditions
Rated operational voltage: 15 to 24 VDC ± 20%
Power consumption: 5 W
Operating temperature: -20°C to +50°C
Storage temperature: -30°C to +70°C
Humidity: 20% to 90% RH (non-condensing)
Protection grade: Front IP40; Screw terminals IP20
Electromagnetic compatibility: EN 61000-6-2 (immunity), EN 61000-6-3 (emissions)
Connectivity & Insulation
Type of input/output
DC power supply
RS485 COM1
RS485 COM2
Ethernet
USB port "H"
USB port "D"
SH2UMMF124 and SH2DSP24
DC power supply
-
2 kV
2 kV
0.5 kV
0 kV
0 kV
0 kV
RS485 COM1
2 kV
-
0.5 kV
2 kV
2 kV
2 kV
2 kV
RS485 COM2
2 kV
0.5 kV
-
2 kV
2 kV
2 kV
2 kV
Ethernet
0.5 kV
2 kV
2 kV
-
0.5 kV
0.5 kV
0.5 kV
USB port "H"
0 kV
2 kV
2 kV
0.5 kV
-
0 kV
0 kV
USB port "D"
0 kV
2 kV
2 kV
0.5 kV
0 kV
-
0 kV
SH2DSP24
0 kV
2 kV
2 kV
0.5 kV
0 kV
0 kV
-
Additional Information
For detailed technical specifications and installation guidelines, please refer to the datasheet.
Note: Datasheet was not processed. Please search the internet for the part number SB2WEB24 for more details.
Unfortunately I havent tested the 5G, Only difficult part was connecting antennas. But everything is good, by default it runs on Qualcom's QMI mode, Had to switch to MBIM and it works good with Windows. Planning to run with OpenWRT soon.
{"id":10016110510397,"title":"SB2WEB24","handle":"sb2web24","description":"\u003ch3\u003eCARLO GAVAZZI SB2WEB24 Specialty Controllers SMART-BUILDING WEB REV.1\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eSB2WEB24\u003c\/strong\u003e is a high-performance BACnet controller designed for HVAC and lighting systems in smart building automation. Manufactured by \u003cstrong\u003eCARLO GAVAZZI\u003c\/strong\u003e in Italy, this specialty controller offers advanced features for building management, energy data logging, and remote control capabilities.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eBACnet\/IP controller with automatic creation of BACnet objects for Dupline® and Energy Meter data points\u003c\/li\u003e\n \u003cli\u003eBTL certified for reliable building automation integration\u003c\/li\u003e\n \u003cli\u003eEmbedded Linux operating system with a micro PC architecture\u003c\/li\u003e\n \u003cli\u003eWeb-server for easy remote access and configuration\u003c\/li\u003e\n \u003cli\u003eTwo RS485 ports supporting Modbus TCP\/RTU communication\u003c\/li\u003e\n \u003cli\u003eOne Ethernet port for LAN connectivity\u003c\/li\u003e\n \u003cli\u003eTwo USB 2.0 ports for programming and data transfer\u003c\/li\u003e\n \u003cli\u003eInternal data storage capable of retaining data for up to 30 years with 4GB memory\u003c\/li\u003e\n \u003cli\u003eData logging, scheduling, alarms, and control of lighting, blinds, and temperature\u003c\/li\u003e\n \u003cli\u003eConfigurable via user-friendly software, compatible with spreadsheets for data export\u003c\/li\u003e\n \u003cli\u003eModular and scalable system architecture for precise sizing and expansion\u003c\/li\u003e\n \u003cli\u003eRemote control and automatic actions for efficient building management\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n \u003cth\u003eElement\u003c\/th\u003e\n \u003cth\u003eComponent\u003c\/th\u003e\n \u003cth\u003eFunction\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eEthernet port\u003c\/td\u003e\n \u003ctd\u003e\u003c\/td\u003e\n \u003ctd\u003eWeb interface display and remote data transmission\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eUSB Port (Host)\u003c\/td\u003e\n \u003ctd\u003e\u003c\/td\u003e\n \u003ctd\u003eIP address programming\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eInformation LED\u003c\/td\u003e\n \u003ctd\u003e\u003c\/td\u003e\n \u003ctd\u003eStatus indication for bus connection, USB, COM ports, and power\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eMicro SD memory card slot\u003c\/td\u003e\n \u003ctd\u003e\u003c\/td\u003e\n \u003ctd\u003eIP address programming\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eMini-USB port (Device)\u003c\/td\u003e\n \u003ctd\u003e\u003c\/td\u003e\n \u003ctd\u003ePC connection for web interface access and backup\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eRS485 COM1 port\u003c\/td\u003e\n \u003ctd\u003e\u003c\/td\u003e\n \u003ctd\u003eConnecting Modbus devices\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eRS485 COM2 port\u003c\/td\u003e\n \u003ctd\u003e\u003c\/td\u003e\n \u003ctd\u003eConnecting Modbus devices\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003ePower terminals\u003c\/td\u003e\n \u003ctd\u003e\u003c\/td\u003e\n \u003ctd\u003ePower supply connection\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eLocal bus ports\u003c\/td\u003e\n \u003ctd\u003e\u003c\/td\u003e\n \u003ctd\u003eConnecting SH2DSP24, SH2MCG24, SH2WBU230N modules\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003ePower Supply \u0026amp; Environmental Conditions\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eRated operational voltage: 15 to 24 VDC ± 20%\u003c\/li\u003e\n \u003cli\u003ePower consumption: 5 W\u003c\/li\u003e\n \u003cli\u003eOperating temperature: -20°C to +50°C\u003c\/li\u003e\n \u003cli\u003eStorage temperature: -30°C to +70°C\u003c\/li\u003e\n \u003cli\u003eHumidity: 20% to 90% RH (non-condensing)\u003c\/li\u003e\n \u003cli\u003eProtection grade: Front IP40; Screw terminals IP20\u003c\/li\u003e\n \u003cli\u003eElectromagnetic compatibility: EN 61000-6-2 (immunity), EN 61000-6-3 (emissions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eConnectivity \u0026amp; Insulation\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n \u003cth\u003eType of input\/output\u003c\/th\u003e\n \u003cth\u003eDC power supply\u003c\/th\u003e\n \u003cth\u003eRS485 COM1\u003c\/th\u003e\n \u003cth\u003eRS485 COM2\u003c\/th\u003e\n \u003cth\u003eEthernet\u003c\/th\u003e\n \u003cth\u003eUSB port \"H\"\u003c\/th\u003e\n \u003cth\u003eUSB port \"D\"\u003c\/th\u003e\n \u003cth\u003eSH2UMMF124 and SH2DSP24\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eDC power supply\u003c\/td\u003e\n \u003ctd\u003e-\u003c\/td\u003e\n \u003ctd\u003e2 kV\u003c\/td\u003e\n \u003ctd\u003e2 kV\u003c\/td\u003e\n \u003ctd\u003e0.5 kV\u003c\/td\u003e\n \u003ctd\u003e0 kV\u003c\/td\u003e\n \u003ctd\u003e0 kV\u003c\/td\u003e\n \u003ctd\u003e0 kV\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eRS485 COM1\u003c\/td\u003e\n \u003ctd\u003e2 kV\u003c\/td\u003e\n \u003ctd\u003e-\u003c\/td\u003e\n \u003ctd\u003e0.5 kV\u003c\/td\u003e\n \u003ctd\u003e2 kV\u003c\/td\u003e\n \u003ctd\u003e2 kV\u003c\/td\u003e\n \u003ctd\u003e2 kV\u003c\/td\u003e\n \u003ctd\u003e2 kV\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eRS485 COM2\u003c\/td\u003e\n \u003ctd\u003e2 kV\u003c\/td\u003e\n \u003ctd\u003e0.5 kV\u003c\/td\u003e\n \u003ctd\u003e-\u003c\/td\u003e\n \u003ctd\u003e2 kV\u003c\/td\u003e\n \u003ctd\u003e2 kV\u003c\/td\u003e\n \u003ctd\u003e2 kV\u003c\/td\u003e\n \u003ctd\u003e2 kV\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eEthernet\u003c\/td\u003e\n \u003ctd\u003e0.5 kV\u003c\/td\u003e\n \u003ctd\u003e2 kV\u003c\/td\u003e\n \u003ctd\u003e2 kV\u003c\/td\u003e\n \u003ctd\u003e-\u003c\/td\u003e\n \u003ctd\u003e0.5 kV\u003c\/td\u003e\n \u003ctd\u003e0.5 kV\u003c\/td\u003e\n \u003ctd\u003e0.5 kV\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eUSB port \"H\"\u003c\/td\u003e\n \u003ctd\u003e0 kV\u003c\/td\u003e\n \u003ctd\u003e2 kV\u003c\/td\u003e\n \u003ctd\u003e2 kV\u003c\/td\u003e\n \u003ctd\u003e0.5 kV\u003c\/td\u003e\n \u003ctd\u003e-\u003c\/td\u003e\n \u003ctd\u003e0 kV\u003c\/td\u003e\n \u003ctd\u003e0 kV\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eUSB port \"D\"\u003c\/td\u003e\n \u003ctd\u003e0 kV\u003c\/td\u003e\n \u003ctd\u003e2 kV\u003c\/td\u003e\n \u003ctd\u003e2 kV\u003c\/td\u003e\n \u003ctd\u003e0.5 kV\u003c\/td\u003e\n \u003ctd\u003e0 kV\u003c\/td\u003e\n \u003ctd\u003e-\u003c\/td\u003e\n \u003ctd\u003e0 kV\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eSH2DSP24\u003c\/td\u003e\n \u003ctd\u003e0 kV\u003c\/td\u003e\n \u003ctd\u003e2 kV\u003c\/td\u003e\n \u003ctd\u003e2 kV\u003c\/td\u003e\n \u003ctd\u003e0.5 kV\u003c\/td\u003e\n \u003ctd\u003e0 kV\u003c\/td\u003e\n \u003ctd\u003e0 kV\u003c\/td\u003e\n \u003ctd\u003e-\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eAdditional Information\u003c\/h3\u003e\n\u003cp\u003eFor detailed technical specifications and installation guidelines, please refer to the \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-cg\/cg-sb2web24.pdf\" target=\"_blank\"\u003edatasheet\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cem\u003eNote: Datasheet was not processed. Please search the internet for the part number SB2WEB24 for more details.\u003c\/em\u003e\u003c\/p\u003e","published_at":"2025-08-11T05:20:19+05:30","created_at":"2025-08-11T05:20:19+05:30","vendor":"Waldom Electonics","type":"Controllers","tags":["CARLO","Controllers","DIN","IMPORT_CSV","Specialty","WEB","WLDM"],"price":15483387,"price_min":15483387,"price_max":15483387,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50590586995005,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"SB2WEB24","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"SB2WEB24","public_title":null,"options":["Default Title"],"price":15483387,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"SB2WEB24","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/SB2WEB24_50927310_3dc35683.jpg?v=1754869822"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/SB2WEB24_50927310_3dc35683.jpg?v=1754869822","options":["Title"],"media":[{"alt":null,"id":45772501877053,"position":1,"preview_image":{"aspect_ratio":1.0,"height":200,"width":200,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/SB2WEB24_50927310_3dc35683.jpg?v=1754869822"},"aspect_ratio":1.0,"height":200,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/SB2WEB24_50927310_3dc35683.jpg?v=1754869822","width":200}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eCARLO GAVAZZI SB2WEB24 Specialty Controllers SMART-BUILDING WEB REV.1\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eSB2WEB24\u003c\/strong\u003e is a high-performance BACnet controller designed for HVAC and lighting systems in smart building automation. Manufactured by \u003cstrong\u003eCARLO GAVAZZI\u003c\/strong\u003e in Italy, this specialty controller offers advanced features for building management, energy data logging, and remote control capabilities.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eBACnet\/IP controller with automatic creation of BACnet objects for Dupline® and Energy Meter data points\u003c\/li\u003e\n \u003cli\u003eBTL certified for reliable building automation integration\u003c\/li\u003e\n \u003cli\u003eEmbedded Linux operating system with a micro PC architecture\u003c\/li\u003e\n \u003cli\u003eWeb-server for easy remote access and configuration\u003c\/li\u003e\n \u003cli\u003eTwo RS485 ports supporting Modbus TCP\/RTU communication\u003c\/li\u003e\n \u003cli\u003eOne Ethernet port for LAN connectivity\u003c\/li\u003e\n \u003cli\u003eTwo USB 2.0 ports for programming and data transfer\u003c\/li\u003e\n \u003cli\u003eInternal data storage capable of retaining data for up to 30 years with 4GB memory\u003c\/li\u003e\n \u003cli\u003eData logging, scheduling, alarms, and control of lighting, blinds, and temperature\u003c\/li\u003e\n \u003cli\u003eConfigurable via user-friendly software, compatible with spreadsheets for data export\u003c\/li\u003e\n \u003cli\u003eModular and scalable system architecture for precise sizing and expansion\u003c\/li\u003e\n \u003cli\u003eRemote control and automatic actions for efficient building management\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n \u003cth\u003eElement\u003c\/th\u003e\n \u003cth\u003eComponent\u003c\/th\u003e\n \u003cth\u003eFunction\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eEthernet port\u003c\/td\u003e\n \u003ctd\u003e\u003c\/td\u003e\n \u003ctd\u003eWeb interface display and remote data transmission\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eUSB Port (Host)\u003c\/td\u003e\n \u003ctd\u003e\u003c\/td\u003e\n \u003ctd\u003eIP address programming\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eInformation LED\u003c\/td\u003e\n \u003ctd\u003e\u003c\/td\u003e\n \u003ctd\u003eStatus indication for bus connection, USB, COM ports, and power\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eMicro SD memory card slot\u003c\/td\u003e\n \u003ctd\u003e\u003c\/td\u003e\n \u003ctd\u003eIP address programming\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eMini-USB port (Device)\u003c\/td\u003e\n \u003ctd\u003e\u003c\/td\u003e\n \u003ctd\u003ePC connection for web interface access and backup\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eRS485 COM1 port\u003c\/td\u003e\n \u003ctd\u003e\u003c\/td\u003e\n \u003ctd\u003eConnecting Modbus devices\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eRS485 COM2 port\u003c\/td\u003e\n \u003ctd\u003e\u003c\/td\u003e\n \u003ctd\u003eConnecting Modbus devices\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003ePower terminals\u003c\/td\u003e\n \u003ctd\u003e\u003c\/td\u003e\n \u003ctd\u003ePower supply connection\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eLocal bus ports\u003c\/td\u003e\n \u003ctd\u003e\u003c\/td\u003e\n \u003ctd\u003eConnecting SH2DSP24, SH2MCG24, SH2WBU230N modules\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003ePower Supply \u0026amp; Environmental Conditions\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eRated operational voltage: 15 to 24 VDC ± 20%\u003c\/li\u003e\n \u003cli\u003ePower consumption: 5 W\u003c\/li\u003e\n \u003cli\u003eOperating temperature: -20°C to +50°C\u003c\/li\u003e\n \u003cli\u003eStorage temperature: -30°C to +70°C\u003c\/li\u003e\n \u003cli\u003eHumidity: 20% to 90% RH (non-condensing)\u003c\/li\u003e\n \u003cli\u003eProtection grade: Front IP40; Screw terminals IP20\u003c\/li\u003e\n \u003cli\u003eElectromagnetic compatibility: EN 61000-6-2 (immunity), EN 61000-6-3 (emissions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eConnectivity \u0026amp; Insulation\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n \u003cth\u003eType of input\/output\u003c\/th\u003e\n \u003cth\u003eDC power supply\u003c\/th\u003e\n \u003cth\u003eRS485 COM1\u003c\/th\u003e\n \u003cth\u003eRS485 COM2\u003c\/th\u003e\n \u003cth\u003eEthernet\u003c\/th\u003e\n \u003cth\u003eUSB port \"H\"\u003c\/th\u003e\n \u003cth\u003eUSB port \"D\"\u003c\/th\u003e\n \u003cth\u003eSH2UMMF124 and SH2DSP24\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eDC power supply\u003c\/td\u003e\n \u003ctd\u003e-\u003c\/td\u003e\n \u003ctd\u003e2 kV\u003c\/td\u003e\n \u003ctd\u003e2 kV\u003c\/td\u003e\n \u003ctd\u003e0.5 kV\u003c\/td\u003e\n \u003ctd\u003e0 kV\u003c\/td\u003e\n \u003ctd\u003e0 kV\u003c\/td\u003e\n \u003ctd\u003e0 kV\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eRS485 COM1\u003c\/td\u003e\n \u003ctd\u003e2 kV\u003c\/td\u003e\n \u003ctd\u003e-\u003c\/td\u003e\n \u003ctd\u003e0.5 kV\u003c\/td\u003e\n \u003ctd\u003e2 kV\u003c\/td\u003e\n \u003ctd\u003e2 kV\u003c\/td\u003e\n \u003ctd\u003e2 kV\u003c\/td\u003e\n \u003ctd\u003e2 kV\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eRS485 COM2\u003c\/td\u003e\n \u003ctd\u003e2 kV\u003c\/td\u003e\n \u003ctd\u003e0.5 kV\u003c\/td\u003e\n \u003ctd\u003e-\u003c\/td\u003e\n \u003ctd\u003e2 kV\u003c\/td\u003e\n \u003ctd\u003e2 kV\u003c\/td\u003e\n \u003ctd\u003e2 kV\u003c\/td\u003e\n \u003ctd\u003e2 kV\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eEthernet\u003c\/td\u003e\n \u003ctd\u003e0.5 kV\u003c\/td\u003e\n \u003ctd\u003e2 kV\u003c\/td\u003e\n \u003ctd\u003e2 kV\u003c\/td\u003e\n \u003ctd\u003e-\u003c\/td\u003e\n \u003ctd\u003e0.5 kV\u003c\/td\u003e\n \u003ctd\u003e0.5 kV\u003c\/td\u003e\n \u003ctd\u003e0.5 kV\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eUSB port \"H\"\u003c\/td\u003e\n \u003ctd\u003e0 kV\u003c\/td\u003e\n \u003ctd\u003e2 kV\u003c\/td\u003e\n \u003ctd\u003e2 kV\u003c\/td\u003e\n \u003ctd\u003e0.5 kV\u003c\/td\u003e\n \u003ctd\u003e-\u003c\/td\u003e\n \u003ctd\u003e0 kV\u003c\/td\u003e\n \u003ctd\u003e0 kV\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eUSB port \"D\"\u003c\/td\u003e\n \u003ctd\u003e0 kV\u003c\/td\u003e\n \u003ctd\u003e2 kV\u003c\/td\u003e\n \u003ctd\u003e2 kV\u003c\/td\u003e\n \u003ctd\u003e0.5 kV\u003c\/td\u003e\n \u003ctd\u003e0 kV\u003c\/td\u003e\n \u003ctd\u003e-\u003c\/td\u003e\n \u003ctd\u003e0 kV\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eSH2DSP24\u003c\/td\u003e\n \u003ctd\u003e0 kV\u003c\/td\u003e\n \u003ctd\u003e2 kV\u003c\/td\u003e\n \u003ctd\u003e2 kV\u003c\/td\u003e\n \u003ctd\u003e0.5 kV\u003c\/td\u003e\n \u003ctd\u003e0 kV\u003c\/td\u003e\n \u003ctd\u003e0 kV\u003c\/td\u003e\n \u003ctd\u003e-\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eAdditional Information\u003c\/h3\u003e\n\u003cp\u003eFor detailed technical specifications and installation guidelines, please refer to the \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-cg\/cg-sb2web24.pdf\" target=\"_blank\"\u003edatasheet\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cem\u003eNote: Datasheet was not processed. Please search the internet for the part number SB2WEB24 for more details.\u003c\/em\u003e\u003c\/p\u003e"}