The CARLO GAVAZZI GDP322S120V is a 2-pole Definite Purpose Contactor designed for reliable switching applications in electrical systems. Recognized for its durability and efficiency, this contactor is suitable for resistive and inductive loads with line voltages up to 600VAC and control voltages up to 480VAC.
Key Features
Switching capacity up to 32A for resistive loads and 90A for inductive loads
Line voltage compatibility up to 600VAC on most sizes
Control voltage options up to 480VAC
Available with screw or box lug terminals on most sizes
Fast-on coil and power terminals for quick installation
Operating Temperature: -5°C to 40°C; Storage: -25°C to 55°C; Humidity: <50% @40°C
Approvals
UL, CSA, CE (EN 60947-4-1:2010+A1)
Additional Details
Designed for use in AC-1 and AC-8a utilization categories
Pollution Degree: 2
Installation angle: Up to 5° from vertical
Altitude: Up to 2000 meters
RoHS compliant for environmental safety
Contact Terminals & Accessories
Power Terminals
Type
Wire Size
Torque
Screw
Phillips, M5
14-12 AWG (2.5~4 mm²)
20 lb-in (2.2 N·m)
Lug
Flat head, M8
14-10 AWG (2.5~6 mm²)
40 lb-in (4.5 N·m)
Disclaimers
Specifications are subject to change without notice. Please refer to the datasheet for the most current information. For detailed technical data, visit the datasheet. If additional details are required, search the internet using the part number GDP322S120V.
Note: The product image displayed is a standard reference image. Actual product appearance may vary. For the most accurate and up-to-date representation, we recommend searching the part number online.
Unfortunately I havent tested the 5G, Only difficult part was connecting antennas. But everything is good, by default it runs on Qualcom's QMI mode, Had to switch to MBIM and it works good with Windows. Planning to run with OpenWRT soon.
{"id":10007082139965,"title":"GDP322S120V","handle":"gdp322s120v","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eCARLO GAVAZZI GDP322S120V\u003c\/strong\u003e is a 2-pole Definite Purpose Contactor designed for reliable switching applications in electrical systems. Recognized for its durability and efficiency, this contactor is suitable for resistive and inductive loads with line voltages up to 600VAC and control voltages up to 480VAC.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eSwitching capacity up to 32A for resistive loads and 90A for inductive loads\u003c\/li\u003e\n \u003cli\u003eLine voltage compatibility up to 600VAC on most sizes\u003c\/li\u003e\n \u003cli\u003eControl voltage options up to 480VAC\u003c\/li\u003e\n \u003cli\u003eAvailable with screw or box lug terminals on most sizes\u003c\/li\u003e\n \u003cli\u003eFast-on coil and power terminals for quick installation\u003c\/li\u003e\n \u003cli\u003eUL recognized and CSA approved for US and Canada\u003c\/li\u003e\n \u003cli\u003eRoHS compliant for environmental safety\u003c\/li\u003e\n \u003cli\u003ePart Number: GDP322S120V\u003c\/li\u003e\n \u003cli\u003eManufacturer: CARLO GAVAZZI\u003c\/li\u003e\n \u003cli\u003eCountry of Origin: CN\u003c\/li\u003e\n \u003cli\u003eUnit of Measure: Each (EA)\u003c\/li\u003e\n \u003cli\u003eECCN: EAR99\u003c\/li\u003e\n \u003cli\u003ePackage Type: Black (BLK)\u003c\/li\u003e\n \u003cli\u003eDatasheet available at \u003ca href=\"https:\/\/www.gavazzionline.com\/pdf\/DP_contactors14eng.pdf\" target=\"_blank\"\u003ehere\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n \u003ctr\u003e\n \u003cth\u003eNumber of Poles\u003c\/th\u003e\n \u003ctd\u003e2\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eAmperage Rating\u003c\/th\u003e\n \u003ctd\u003e32 Amps\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eControl Voltage\u003c\/th\u003e\n \u003ctd\u003e110\/120 VAC\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eLine Voltage\u003c\/th\u003e\n \u003ctd\u003eUp to 600VAC\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eSwitching Capacity\u003c\/th\u003e\n \u003ctd\u003eResistive: 100A; Inductive: 90A\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eCoil Specifications\u003c\/th\u003e\n \u003ctd\u003eIn-rush VA: 83; Sealed VA: 14; Frequency: 50\/60Hz; Drop-out Voltage: 20% ~ 65% Uc\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eEnvironmental Conditions\u003c\/th\u003e\n \u003ctd\u003eOperating Temperature: -5°C to 40°C; Storage: -25°C to 55°C; Humidity: \u0026lt;50% @40°C\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eApprovals\u003c\/th\u003e\n \u003ctd\u003eUL, CSA, CE (EN 60947-4-1:2010+A1)\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eAdditional Details\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eDesigned for use in AC-1 and AC-8a utilization categories\u003c\/li\u003e\n \u003cli\u003ePollution Degree: 2\u003c\/li\u003e\n \u003cli\u003eInstallation angle: Up to 5° from vertical\u003c\/li\u003e\n \u003cli\u003eAltitude: Up to 2000 meters\u003c\/li\u003e\n \u003cli\u003eRoHS compliant for environmental safety\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eContact Terminals \u0026amp; Accessories\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n \u003ctr\u003e\n \u003cth\u003ePower Terminals\u003c\/th\u003e\n \u003cth\u003eType\u003c\/th\u003e\n \u003cth\u003eWire Size\u003c\/th\u003e\n \u003cth\u003eTorque\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eScrew\u003c\/td\u003e\n \u003ctd\u003ePhillips, M5\u003c\/td\u003e\n \u003ctd\u003e14-12 AWG (2.5~4 mm²)\u003c\/td\u003e\n \u003ctd\u003e20 lb-in (2.2 N·m)\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eLug\u003c\/td\u003e\n \u003ctd\u003eFlat head, M8\u003c\/td\u003e\n \u003ctd\u003e14-10 AWG (2.5~6 mm²)\u003c\/td\u003e\n \u003ctd\u003e40 lb-in (4.5 N·m)\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDisclaimers\u003c\/h3\u003e\n\u003cp\u003eSpecifications are subject to change without notice. Please refer to the datasheet for the most current information. For detailed technical data, visit the \u003ca href=\"https:\/\/www.gavazzionline.com\/pdf\/DP_contactors14eng.pdf\" target=\"_blank\"\u003edatasheet\u003c\/a\u003e. If additional details are required, search the internet using the part number \u003cstrong\u003eGDP322S120V\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNote: The product image displayed is a standard reference image. Actual product appearance may vary. For the most accurate and up-to-date representation, we recommend searching the part number online.\u003c\/strong\u003e\u003c\/p\u003e","published_at":"2025-08-07T10:26:21+05:30","created_at":"2025-08-07T10:26:21+05:30","vendor":"Waldom Electonics","type":"","tags":["120VAC","32A","CARLO","DPC","STD_IMG","WLDM"],"price":244890,"price_min":244890,"price_max":244890,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50558588223805,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"GDP322S120V","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"GDP322S120V","public_title":null,"options":["Default Title"],"price":244890,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"GDP322S120V","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/fbe811dc-181f-41c1-ab5a-dc3410446d1d_804746af-282d-408a-868c-3ce856c349f8.jpg?v=1754542581"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/fbe811dc-181f-41c1-ab5a-dc3410446d1d_804746af-282d-408a-868c-3ce856c349f8.jpg?v=1754542581","options":["Title"],"media":[{"alt":null,"id":45708912886077,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1024,"width":1024,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/fbe811dc-181f-41c1-ab5a-dc3410446d1d_804746af-282d-408a-868c-3ce856c349f8.jpg?v=1754542581"},"aspect_ratio":1.0,"height":1024,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/fbe811dc-181f-41c1-ab5a-dc3410446d1d_804746af-282d-408a-868c-3ce856c349f8.jpg?v=1754542581","width":1024}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eCARLO GAVAZZI GDP322S120V\u003c\/strong\u003e is a 2-pole Definite Purpose Contactor designed for reliable switching applications in electrical systems. Recognized for its durability and efficiency, this contactor is suitable for resistive and inductive loads with line voltages up to 600VAC and control voltages up to 480VAC.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eSwitching capacity up to 32A for resistive loads and 90A for inductive loads\u003c\/li\u003e\n \u003cli\u003eLine voltage compatibility up to 600VAC on most sizes\u003c\/li\u003e\n \u003cli\u003eControl voltage options up to 480VAC\u003c\/li\u003e\n \u003cli\u003eAvailable with screw or box lug terminals on most sizes\u003c\/li\u003e\n \u003cli\u003eFast-on coil and power terminals for quick installation\u003c\/li\u003e\n \u003cli\u003eUL recognized and CSA approved for US and Canada\u003c\/li\u003e\n \u003cli\u003eRoHS compliant for environmental safety\u003c\/li\u003e\n \u003cli\u003ePart Number: GDP322S120V\u003c\/li\u003e\n \u003cli\u003eManufacturer: CARLO GAVAZZI\u003c\/li\u003e\n \u003cli\u003eCountry of Origin: CN\u003c\/li\u003e\n \u003cli\u003eUnit of Measure: Each (EA)\u003c\/li\u003e\n \u003cli\u003eECCN: EAR99\u003c\/li\u003e\n \u003cli\u003ePackage Type: Black (BLK)\u003c\/li\u003e\n \u003cli\u003eDatasheet available at \u003ca href=\"https:\/\/www.gavazzionline.com\/pdf\/DP_contactors14eng.pdf\" target=\"_blank\"\u003ehere\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n \u003ctr\u003e\n \u003cth\u003eNumber of Poles\u003c\/th\u003e\n \u003ctd\u003e2\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eAmperage Rating\u003c\/th\u003e\n \u003ctd\u003e32 Amps\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eControl Voltage\u003c\/th\u003e\n \u003ctd\u003e110\/120 VAC\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eLine Voltage\u003c\/th\u003e\n \u003ctd\u003eUp to 600VAC\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eSwitching Capacity\u003c\/th\u003e\n \u003ctd\u003eResistive: 100A; Inductive: 90A\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eCoil Specifications\u003c\/th\u003e\n \u003ctd\u003eIn-rush VA: 83; Sealed VA: 14; Frequency: 50\/60Hz; Drop-out Voltage: 20% ~ 65% Uc\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eEnvironmental Conditions\u003c\/th\u003e\n \u003ctd\u003eOperating Temperature: -5°C to 40°C; Storage: -25°C to 55°C; Humidity: \u0026lt;50% @40°C\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eApprovals\u003c\/th\u003e\n \u003ctd\u003eUL, CSA, CE (EN 60947-4-1:2010+A1)\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eAdditional Details\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eDesigned for use in AC-1 and AC-8a utilization categories\u003c\/li\u003e\n \u003cli\u003ePollution Degree: 2\u003c\/li\u003e\n \u003cli\u003eInstallation angle: Up to 5° from vertical\u003c\/li\u003e\n \u003cli\u003eAltitude: Up to 2000 meters\u003c\/li\u003e\n \u003cli\u003eRoHS compliant for environmental safety\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eContact Terminals \u0026amp; Accessories\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n \u003ctr\u003e\n \u003cth\u003ePower Terminals\u003c\/th\u003e\n \u003cth\u003eType\u003c\/th\u003e\n \u003cth\u003eWire Size\u003c\/th\u003e\n \u003cth\u003eTorque\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eScrew\u003c\/td\u003e\n \u003ctd\u003ePhillips, M5\u003c\/td\u003e\n \u003ctd\u003e14-12 AWG (2.5~4 mm²)\u003c\/td\u003e\n \u003ctd\u003e20 lb-in (2.2 N·m)\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eLug\u003c\/td\u003e\n \u003ctd\u003eFlat head, M8\u003c\/td\u003e\n \u003ctd\u003e14-10 AWG (2.5~6 mm²)\u003c\/td\u003e\n \u003ctd\u003e40 lb-in (4.5 N·m)\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDisclaimers\u003c\/h3\u003e\n\u003cp\u003eSpecifications are subject to change without notice. Please refer to the datasheet for the most current information. For detailed technical data, visit the \u003ca href=\"https:\/\/www.gavazzionline.com\/pdf\/DP_contactors14eng.pdf\" target=\"_blank\"\u003edatasheet\u003c\/a\u003e. If additional details are required, search the internet using the part number \u003cstrong\u003eGDP322S120V\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNote: The product image displayed is a standard reference image. Actual product appearance may vary. For the most accurate and up-to-date representation, we recommend searching the part number online.\u003c\/strong\u003e\u003c\/p\u003e"}