The ICB12SF02NOM1 is a high-quality inductive proximity sensor manufactured by CARLO GAVAZZI. Designed for industrial applications, this sensor features a nickel-plated brass housing with a sensing distance of 2 mm, making it suitable for precise detection in various environments.
Product Features
Standard range inductive proximity sensor with nickel-plated brass housing (Type ICB, M12)
Sensing distance: 2 mm
Flush mounting type for seamless integration
Available in short and long body versions
Rated operational voltage: 10 - 36 VDC
Output configurations: DC 200 mA, NPN or PNP, normally open or normally closed
LED indicator for output ON status
Protection features include reverse polarity, short circuit, and transient protection
Available with cable or M12 plug connection options
Complies with IEC 60947-5-2 standards
Higher resistance to magnetic fields
CSA certified for Hazardous Locations
Technical Specifications
Sensing Distance
2 mm
Housing Material
Nickel-plated brass
Rated Operational Voltage (Ub)
10 - 36 VDC
Output Current
DC 200 mA
Connection Types
Cable or M12 plug
Protection
Reverse polarity, short circuit, transients
Standards
IEC 60947-5-2
Dimensions
Diameter
12 mm (M12)
Body Length
7.5 mm
Installation Guidelines
Flush sensors should be installed according to the provided diagrams, especially when placed in damping materials. When sensors are installed opposite each other, maintain a minimum space of 6 times the nominal sensing distance (Sn). Proper installation ensures optimal performance and longevity of the sensor.
Wiring and Connection
Refer to the wiring diagrams for NPN and PNP configurations, both normally open and normally closed. Proper wiring is essential for reliable operation.
Reduction Factors
The sensing distance may be reduced when metals or alloys other than Fe360 are used. Refer to the specific reduction factors for accurate sensing range calculations.
Note: Specifications are subject to change without notice. Please refer to the datasheet for the most current information. For additional options or custom configurations, consult the datasheet or contact the manufacturer.
Use left/right arrows to navigate the slideshow or swipe left/right if using a mobile device
Choosing a selection results in a full page refresh.
Press the space key then arrow keys to make a selection.
Shopping Cart
{"id":10020411146557,"title":"ICB12SF02NOM1","handle":"icb12sf02nom1","description":"\u003ch3\u003eProximity Inductive Sensor - ICB12SF02NOM1\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eICB12SF02NOM1\u003c\/strong\u003e is a high-quality inductive proximity sensor manufactured by \u003cstrong\u003eCARLO GAVAZZI\u003c\/strong\u003e. Designed for industrial applications, this sensor features a nickel-plated brass housing with a sensing distance of 2 mm, making it suitable for precise detection in various environments.\u003c\/p\u003e\n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eStandard range inductive proximity sensor with nickel-plated brass housing (Type ICB, M12)\u003c\/li\u003e\n \u003cli\u003eSensing distance: 2 mm\u003c\/li\u003e\n \u003cli\u003eFlush mounting type for seamless integration\u003c\/li\u003e\n \u003cli\u003eAvailable in short and long body versions\u003c\/li\u003e\n \u003cli\u003eRated operational voltage: 10 - 36 VDC\u003c\/li\u003e\n \u003cli\u003eOutput configurations: DC 200 mA, NPN or PNP, normally open or normally closed\u003c\/li\u003e\n \u003cli\u003eLED indicator for output ON status\u003c\/li\u003e\n \u003cli\u003eProtection features include reverse polarity, short circuit, and transient protection\u003c\/li\u003e\n \u003cli\u003eAvailable with cable or M12 plug connection options\u003c\/li\u003e\n \u003cli\u003eComplies with IEC 60947-5-2 standards\u003c\/li\u003e\n \u003cli\u003eHigher resistance to magnetic fields\u003c\/li\u003e\n \u003cli\u003eCSA certified for Hazardous Locations\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n \u003cth\u003eSensing Distance\u003c\/th\u003e\n \u003ctd\u003e2 mm\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eHousing Material\u003c\/th\u003e\n \u003ctd\u003eNickel-plated brass\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eRated Operational Voltage (U\u003csub\u003eb\u003c\/sub\u003e)\u003c\/th\u003e\n \u003ctd\u003e10 - 36 VDC\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eOutput Current\u003c\/th\u003e\n \u003ctd\u003eDC 200 mA\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eConnection Types\u003c\/th\u003e\n \u003ctd\u003eCable or M12 plug\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eProtection\u003c\/th\u003e\n \u003ctd\u003eReverse polarity, short circuit, transients\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eStandards\u003c\/th\u003e\n \u003ctd\u003eIEC 60947-5-2\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n \u003ctd\u003eDiameter\u003c\/td\u003e\n \u003ctd\u003e12 mm (M12)\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eBody Length\u003c\/td\u003e\n \u003ctd\u003e7.5 mm\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eFlush sensors should be installed according to the provided diagrams, especially when placed in damping materials. When sensors are installed opposite each other, maintain a minimum space of 6 times the nominal sensing distance (Sn). Proper installation ensures optimal performance and longevity of the sensor.\u003c\/p\u003e\n\n\u003ch3\u003eWiring and Connection\u003c\/h3\u003e\n\u003cp\u003eRefer to the wiring diagrams for NPN and PNP configurations, both normally open and normally closed. Proper wiring is essential for reliable operation.\u003c\/p\u003e\n\n\u003ch3\u003eReduction Factors\u003c\/h3\u003e\n\u003cp\u003eThe sensing distance may be reduced when metals or alloys other than Fe360 are used. Refer to the specific reduction factors for accurate sensing range calculations.\u003c\/p\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n \u003cth\u003eConnection Style\u003c\/th\u003e\n \u003cth\u003eRated Distance\u003c\/th\u003e\n \u003cth\u003eOutput Configuration\u003c\/th\u003e\n \u003cth\u003ePart Number\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eCable Short\u003c\/td\u003e\n \u003ctd\u003e2 mm\u003c\/td\u003e\n \u003ctd\u003eNPN NO\u003c\/td\u003e\n \u003ctd\u003eICB 12 SF 02 NO\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eCable Short\u003c\/td\u003e\n \u003ctd\u003e2 mm\u003c\/td\u003e\n \u003ctd\u003ePNP NO\u003c\/td\u003e\n \u003ctd\u003eICB 12 SF 02 PO\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eCable Short\u003c\/td\u003e\n \u003ctd\u003e2 mm\u003c\/td\u003e\n \u003ctd\u003eNPN NC\u003c\/td\u003e\n \u003ctd\u003eICB 12 SF 02 NC\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eCable Short\u003c\/td\u003e\n \u003ctd\u003e2 mm\u003c\/td\u003e\n \u003ctd\u003ePNP NC\u003c\/td\u003e\n \u003ctd\u003eICB 12 SF 02 PC\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003ePlug Short\u003c\/td\u003e\n \u003ctd\u003e2 mm\u003c\/td\u003e\n \u003ctd\u003eNPN NO\u003c\/td\u003e\n \u003ctd\u003eICB 12 SF 02 NOM1\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003ePlug Short\u003c\/td\u003e\n \u003ctd\u003e2 mm\u003c\/td\u003e\n \u003ctd\u003ePNP NO\u003c\/td\u003e\n \u003ctd\u003eICB 12 SF 02 POM1\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003ePlug Short\u003c\/td\u003e\n \u003ctd\u003e2 mm\u003c\/td\u003e\n \u003ctd\u003eNPN NC\u003c\/td\u003e\n \u003ctd\u003eICB 12 SF 02 NCM1\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003ePlug Short\u003c\/td\u003e\n \u003ctd\u003e2 mm\u003c\/td\u003e\n \u003ctd\u003ePNP NC\u003c\/td\u003e\n \u003ctd\u003eICB 12 SF 02 PCM1\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eCable Long\u003c\/td\u003e\n \u003ctd\u003e2 mm\u003c\/td\u003e\n \u003ctd\u003eNPN NO\u003c\/td\u003e\n \u003ctd\u003eICB 12 LF 02 NO\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eCable Long\u003c\/td\u003e\n \u003ctd\u003e2 mm\u003c\/td\u003e\n \u003ctd\u003ePNP NO\u003c\/td\u003e\n \u003ctd\u003eICB 12 LF 02 PO\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eCable Long\u003c\/td\u003e\n \u003ctd\u003e2 mm\u003c\/td\u003e\n \u003ctd\u003eNPN NC\u003c\/td\u003e\n \u003ctd\u003eICB 12 LF 02 NC\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eCable Long\u003c\/td\u003e\n \u003ctd\u003e2 mm\u003c\/td\u003e\n \u003ctd\u003ePNP NC\u003c\/td\u003e\n \u003ctd\u003eICB 12 LF 02 PC\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003ePlug Long\u003c\/td\u003e\n \u003ctd\u003e2 mm\u003c\/td\u003e\n \u003ctd\u003eNPN NO\u003c\/td\u003e\n \u003ctd\u003eICB 12 LF 02 NOM1\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003ePlug Long\u003c\/td\u003e\n \u003ctd\u003e2 mm\u003c\/td\u003e\n \u003ctd\u003ePNP NO\u003c\/td\u003e\n \u003ctd\u003eICB 12 LF 02 POM1\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003ePlug Long\u003c\/td\u003e\n \u003ctd\u003e2 mm\u003c\/td\u003e\n \u003ctd\u003eNPN NC\u003c\/td\u003e\n \u003ctd\u003eICB 12 LF 02 NCM1\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003ePlug Long\u003c\/td\u003e\n \u003ctd\u003e2 mm\u003c\/td\u003e\n \u003ctd\u003ePNP NC\u003c\/td\u003e\n \u003ctd\u003eICB 12 LF 02 PCM1\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eAdditional Information\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003ePart Number: ICB12SF02NOM1\u003c\/li\u003e\n \u003cli\u003eManufacturer: CARLO GAVAZZI\u003c\/li\u003e\n \u003cli\u003eCountry of Origin: LT\u003c\/li\u003e\n \u003cli\u003eUnit of Measure: EA\u003c\/li\u003e\n \u003cli\u003eECCN: EAR99\u003c\/li\u003e\n \u003cli\u003ePackage Type: Not specified\u003c\/li\u003e\n \u003cli\u003eDatasheet: \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-cg\/cg-icb12sf02nom1.pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cem\u003eNote: Specifications are subject to change without notice. Please refer to the datasheet for the most current information. For additional options or custom configurations, consult the datasheet or contact the manufacturer.\u003c\/em\u003e\u003c\/p\u003e","published_at":"2025-08-12T01:24:02+05:30","created_at":"2025-08-12T01:24:02+05:30","vendor":"Waldom Electonics","type":"Sensors\/Transducers","tags":["CARLO","IMPORT_CSV","Proximity","Sensors","Transducers","WLDM"],"price":710972,"price_min":710972,"price_max":710972,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50609954455869,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"ICB12SF02NOM1","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"ICB12SF02NOM1","public_title":null,"options":["Default Title"],"price":710972,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"ICB12SF02NOM1","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/43917983.jpg?v=1754942044"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/43917983.jpg?v=1754942044","options":["Title"],"media":[{"alt":null,"id":45789045588285,"position":1,"preview_image":{"aspect_ratio":1.0,"height":640,"width":640,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/43917983.jpg?v=1754942044"},"aspect_ratio":1.0,"height":640,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/43917983.jpg?v=1754942044","width":640}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eProximity Inductive Sensor - ICB12SF02NOM1\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eICB12SF02NOM1\u003c\/strong\u003e is a high-quality inductive proximity sensor manufactured by \u003cstrong\u003eCARLO GAVAZZI\u003c\/strong\u003e. Designed for industrial applications, this sensor features a nickel-plated brass housing with a sensing distance of 2 mm, making it suitable for precise detection in various environments.\u003c\/p\u003e\n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eStandard range inductive proximity sensor with nickel-plated brass housing (Type ICB, M12)\u003c\/li\u003e\n \u003cli\u003eSensing distance: 2 mm\u003c\/li\u003e\n \u003cli\u003eFlush mounting type for seamless integration\u003c\/li\u003e\n \u003cli\u003eAvailable in short and long body versions\u003c\/li\u003e\n \u003cli\u003eRated operational voltage: 10 - 36 VDC\u003c\/li\u003e\n \u003cli\u003eOutput configurations: DC 200 mA, NPN or PNP, normally open or normally closed\u003c\/li\u003e\n \u003cli\u003eLED indicator for output ON status\u003c\/li\u003e\n \u003cli\u003eProtection features include reverse polarity, short circuit, and transient protection\u003c\/li\u003e\n \u003cli\u003eAvailable with cable or M12 plug connection options\u003c\/li\u003e\n \u003cli\u003eComplies with IEC 60947-5-2 standards\u003c\/li\u003e\n \u003cli\u003eHigher resistance to magnetic fields\u003c\/li\u003e\n \u003cli\u003eCSA certified for Hazardous Locations\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n \u003cth\u003eSensing Distance\u003c\/th\u003e\n \u003ctd\u003e2 mm\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eHousing Material\u003c\/th\u003e\n \u003ctd\u003eNickel-plated brass\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eRated Operational Voltage (U\u003csub\u003eb\u003c\/sub\u003e)\u003c\/th\u003e\n \u003ctd\u003e10 - 36 VDC\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eOutput Current\u003c\/th\u003e\n \u003ctd\u003eDC 200 mA\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eConnection Types\u003c\/th\u003e\n \u003ctd\u003eCable or M12 plug\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eProtection\u003c\/th\u003e\n \u003ctd\u003eReverse polarity, short circuit, transients\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eStandards\u003c\/th\u003e\n \u003ctd\u003eIEC 60947-5-2\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n \u003ctd\u003eDiameter\u003c\/td\u003e\n \u003ctd\u003e12 mm (M12)\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eBody Length\u003c\/td\u003e\n \u003ctd\u003e7.5 mm\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eFlush sensors should be installed according to the provided diagrams, especially when placed in damping materials. When sensors are installed opposite each other, maintain a minimum space of 6 times the nominal sensing distance (Sn). Proper installation ensures optimal performance and longevity of the sensor.\u003c\/p\u003e\n\n\u003ch3\u003eWiring and Connection\u003c\/h3\u003e\n\u003cp\u003eRefer to the wiring diagrams for NPN and PNP configurations, both normally open and normally closed. Proper wiring is essential for reliable operation.\u003c\/p\u003e\n\n\u003ch3\u003eReduction Factors\u003c\/h3\u003e\n\u003cp\u003eThe sensing distance may be reduced when metals or alloys other than Fe360 are used. Refer to the specific reduction factors for accurate sensing range calculations.\u003c\/p\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n \u003cth\u003eConnection Style\u003c\/th\u003e\n \u003cth\u003eRated Distance\u003c\/th\u003e\n \u003cth\u003eOutput Configuration\u003c\/th\u003e\n \u003cth\u003ePart Number\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eCable Short\u003c\/td\u003e\n \u003ctd\u003e2 mm\u003c\/td\u003e\n \u003ctd\u003eNPN NO\u003c\/td\u003e\n \u003ctd\u003eICB 12 SF 02 NO\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eCable Short\u003c\/td\u003e\n \u003ctd\u003e2 mm\u003c\/td\u003e\n \u003ctd\u003ePNP NO\u003c\/td\u003e\n \u003ctd\u003eICB 12 SF 02 PO\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eCable Short\u003c\/td\u003e\n \u003ctd\u003e2 mm\u003c\/td\u003e\n \u003ctd\u003eNPN NC\u003c\/td\u003e\n \u003ctd\u003eICB 12 SF 02 NC\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eCable Short\u003c\/td\u003e\n \u003ctd\u003e2 mm\u003c\/td\u003e\n \u003ctd\u003ePNP NC\u003c\/td\u003e\n \u003ctd\u003eICB 12 SF 02 PC\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003ePlug Short\u003c\/td\u003e\n \u003ctd\u003e2 mm\u003c\/td\u003e\n \u003ctd\u003eNPN NO\u003c\/td\u003e\n \u003ctd\u003eICB 12 SF 02 NOM1\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003ePlug Short\u003c\/td\u003e\n \u003ctd\u003e2 mm\u003c\/td\u003e\n \u003ctd\u003ePNP NO\u003c\/td\u003e\n \u003ctd\u003eICB 12 SF 02 POM1\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003ePlug Short\u003c\/td\u003e\n \u003ctd\u003e2 mm\u003c\/td\u003e\n \u003ctd\u003eNPN NC\u003c\/td\u003e\n \u003ctd\u003eICB 12 SF 02 NCM1\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003ePlug Short\u003c\/td\u003e\n \u003ctd\u003e2 mm\u003c\/td\u003e\n \u003ctd\u003ePNP NC\u003c\/td\u003e\n \u003ctd\u003eICB 12 SF 02 PCM1\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eCable Long\u003c\/td\u003e\n \u003ctd\u003e2 mm\u003c\/td\u003e\n \u003ctd\u003eNPN NO\u003c\/td\u003e\n \u003ctd\u003eICB 12 LF 02 NO\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eCable Long\u003c\/td\u003e\n \u003ctd\u003e2 mm\u003c\/td\u003e\n \u003ctd\u003ePNP NO\u003c\/td\u003e\n \u003ctd\u003eICB 12 LF 02 PO\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eCable Long\u003c\/td\u003e\n \u003ctd\u003e2 mm\u003c\/td\u003e\n \u003ctd\u003eNPN NC\u003c\/td\u003e\n \u003ctd\u003eICB 12 LF 02 NC\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eCable Long\u003c\/td\u003e\n \u003ctd\u003e2 mm\u003c\/td\u003e\n \u003ctd\u003ePNP NC\u003c\/td\u003e\n \u003ctd\u003eICB 12 LF 02 PC\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003ePlug Long\u003c\/td\u003e\n \u003ctd\u003e2 mm\u003c\/td\u003e\n \u003ctd\u003eNPN NO\u003c\/td\u003e\n \u003ctd\u003eICB 12 LF 02 NOM1\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003ePlug Long\u003c\/td\u003e\n \u003ctd\u003e2 mm\u003c\/td\u003e\n \u003ctd\u003ePNP NO\u003c\/td\u003e\n \u003ctd\u003eICB 12 LF 02 POM1\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003ePlug Long\u003c\/td\u003e\n \u003ctd\u003e2 mm\u003c\/td\u003e\n \u003ctd\u003eNPN NC\u003c\/td\u003e\n \u003ctd\u003eICB 12 LF 02 NCM1\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003ePlug Long\u003c\/td\u003e\n \u003ctd\u003e2 mm\u003c\/td\u003e\n \u003ctd\u003ePNP NC\u003c\/td\u003e\n \u003ctd\u003eICB 12 LF 02 PCM1\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eAdditional Information\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003ePart Number: ICB12SF02NOM1\u003c\/li\u003e\n \u003cli\u003eManufacturer: CARLO GAVAZZI\u003c\/li\u003e\n \u003cli\u003eCountry of Origin: LT\u003c\/li\u003e\n \u003cli\u003eUnit of Measure: EA\u003c\/li\u003e\n \u003cli\u003eECCN: EAR99\u003c\/li\u003e\n \u003cli\u003ePackage Type: Not specified\u003c\/li\u003e\n \u003cli\u003eDatasheet: \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-cg\/cg-icb12sf02nom1.pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cem\u003eNote: Specifications are subject to change without notice. Please refer to the datasheet for the most current information. For additional options or custom configurations, consult the datasheet or contact the manufacturer.\u003c\/em\u003e\u003c\/p\u003e"}
Unfortunately I havent tested the 5G, Only difficult part was connecting antennas. But everything is good, by default it runs on Qualcom's QMI mode, Had to switch to MBIM and it works good with Windows. Planning to run with OpenWRT soon.