CARLO GAVAZZI ICB18L50N08NO Inductive Proximity Sensor - 8mm Cylindrical
The CARLO GAVAZZI ICB18L50N08NO is a high-performance inductive proximity sensor designed for industrial automation applications. It features a nickel-plated brass housing with a sensing distance of 5 to 8 mm, suitable for both flush and non-flush mounting configurations. This sensor provides reliable detection of metallic objects, ensuring precise and consistent operation in demanding environments.
Product Features
Sensing distance: 5 to 8 mm
Housing: Nickel-plated brass, M18 standard
Mounting options: Flush or non-flush, short or long body versions
Output: DC 200 mA, NPN or PNP transistor, normally open or normally closed
Operational voltage: 10 - 36 VDC
LED indicator for output status
Protection features: reverse polarity, short circuit, transients
Connection types: Cable or M12 plug
Compliance: IEC 60947-5-2, CSA certified for Hazardous Locations
Note: For detailed specifications, please refer to the datasheet.
Dimensions (mm)
Body Length
Diameter
74.0 mm (Long body, flush version, plug)
18 mm (M18)
Installation & Wiring
Proper installation is critical for optimal sensor performance. When installing flush sensors in damping material, follow the guidelines provided in the datasheet. Maintain a minimum space of 6 x sensing distance (Sn) when sensors are installed opposite each other. Wiring diagrams are available to ensure correct electrical connections.
Additional Information
Accessories for plug versions are available; refer to the "General Accessories - Connector Cables - Type CONB1..." datasheets for options.
Delivery includes the inductive proximity switch, 2 nuts (NPB), and packaging in a plastic bag.
For more detailed technical information, please consult the datasheet. Note: The datasheet content provided is based on available data; for comprehensive specifications, visit the manufacturer's website or contact Think Robotics.
Use left/right arrows to navigate the slideshow or swipe left/right if using a mobile device
Choosing a selection results in a full page refresh.
Press the space key then arrow keys to make a selection.
Shopping Cart
{"id":10021354864957,"title":"ICB18L50N08NO","handle":"icb18l50n08no","description":"\u003ch3\u003eCARLO GAVAZZI ICB18L50N08NO Inductive Proximity Sensor - 8mm Cylindrical\u003c\/h3\u003e\n\n\u003cp\u003eThe CARLO GAVAZZI ICB18L50N08NO is a high-performance inductive proximity sensor designed for industrial automation applications. It features a nickel-plated brass housing with a sensing distance of 5 to 8 mm, suitable for both flush and non-flush mounting configurations. This sensor provides reliable detection of metallic objects, ensuring precise and consistent operation in demanding environments.\u003c\/p\u003e\n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eSensing distance: 5 to 8 mm\u003c\/li\u003e\n \u003cli\u003eHousing: Nickel-plated brass, M18 standard\u003c\/li\u003e\n \u003cli\u003eMounting options: Flush or non-flush, short or long body versions\u003c\/li\u003e\n \u003cli\u003eOutput: DC 200 mA, NPN or PNP transistor, normally open or normally closed\u003c\/li\u003e\n \u003cli\u003eOperational voltage: 10 - 36 VDC\u003c\/li\u003e\n \u003cli\u003eLED indicator for output status\u003c\/li\u003e\n \u003cli\u003eProtection features: reverse polarity, short circuit, transients\u003c\/li\u003e\n \u003cli\u003eConnection types: Cable or M12 plug\u003c\/li\u003e\n \u003cli\u003eCompliance: IEC 60947-5-2, CSA certified for Hazardous Locations\u003c\/li\u003e\n \u003cli\u003ePart Number: ICB18L50N08NO\u003c\/li\u003e\n \u003cli\u003eManufacturer: CARLO GAVAZZI\u003c\/li\u003e\n \u003cli\u003eCountry of Origin: LT (Lithuania)\u003c\/li\u003e\n \u003cli\u003eUnit of Measure: Each (EA)\u003c\/li\u003e\n \u003cli\u003eECCN: EAR99\u003c\/li\u003e\n \u003cli\u003ePackage Type: Box\u003c\/li\u003e\n \u003cli\u003eDatasheet: \u003ca href=\"http:\/\/cga.pub\/?73a3b3\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n \u003ctr\u003e\n \u003cth\u003eType\u003c\/th\u003e\n \u003cth\u003eConnection Style\u003c\/th\u003e\n \u003cth\u003eSensing Distance\u003c\/th\u003e\n \u003cth\u003eOutput\u003c\/th\u003e\n \u003cth\u003eRated Operational Voltage (Ub)\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eInductive Proximity Sensor\u003c\/td\u003e\n \u003ctd\u003eCable \/ M12 Plug\u003c\/td\u003e\n \u003ctd\u003e8 mm (non-flush)\u003c\/td\u003e\n \u003ctd\u003eNPN or PNP, Normally Open\/Closed\u003c\/td\u003e\n \u003ctd\u003e10 - 36 VDC\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd colspan=\"5\"\u003eNote: For detailed specifications, please refer to the datasheet.\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDimensions (mm)\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n \u003ctr\u003e\n \u003cth\u003eBody Length\u003c\/th\u003e\n \u003cth\u003eDiameter\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e74.0 mm (Long body, flush version, plug)\u003c\/td\u003e\n \u003ctd\u003e18 mm (M18)\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation \u0026amp; Wiring\u003c\/h3\u003e\n\u003cp\u003eProper installation is critical for optimal sensor performance. When installing flush sensors in damping material, follow the guidelines provided in the datasheet. Maintain a minimum space of 6 x sensing distance (S\u003csub\u003en\u003c\/sub\u003e) when sensors are installed opposite each other. Wiring diagrams are available to ensure correct electrical connections.\u003c\/p\u003e\n\n\u003ch3\u003eAdditional Information\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eAccessories for plug versions are available; refer to the \"General Accessories - Connector Cables - Type CONB1...\" datasheets for options.\u003c\/li\u003e\n \u003cli\u003eDelivery includes the inductive proximity switch, 2 nuts (NPB), and packaging in a plastic bag.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eFor more detailed technical information, please consult the \u003ca href=\"http:\/\/cga.pub\/?73a3b3\" target=\"_blank\"\u003edatasheet\u003c\/a\u003e. Note: The datasheet content provided is based on available data; for comprehensive specifications, visit the manufacturer's website or contact Think Robotics.\u003c\/p\u003e","published_at":"2025-08-12T15:46:22+05:30","created_at":"2025-08-12T15:46:22+05:30","vendor":"Waldom Electonics","type":"Sensors\/Transducers","tags":["8MM","CARLO","IMPORT_CSV","PROX","Proximity","Sensors","Transducers","WLDM"],"price":588735,"price_min":588735,"price_max":588735,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50612236812605,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"ICB18L50N08NO","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"ICB18L50N08NO","public_title":null,"options":["Default Title"],"price":588735,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"ICB18L50N08NO","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/49101775.png?v=1754993786"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/49101775.png?v=1754993786","options":["Title"],"media":[{"alt":null,"id":45801637249341,"position":1,"preview_image":{"aspect_ratio":1.0,"height":400,"width":400,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/49101775.png?v=1754993786"},"aspect_ratio":1.0,"height":400,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/49101775.png?v=1754993786","width":400}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eCARLO GAVAZZI ICB18L50N08NO Inductive Proximity Sensor - 8mm Cylindrical\u003c\/h3\u003e\n\n\u003cp\u003eThe CARLO GAVAZZI ICB18L50N08NO is a high-performance inductive proximity sensor designed for industrial automation applications. It features a nickel-plated brass housing with a sensing distance of 5 to 8 mm, suitable for both flush and non-flush mounting configurations. This sensor provides reliable detection of metallic objects, ensuring precise and consistent operation in demanding environments.\u003c\/p\u003e\n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eSensing distance: 5 to 8 mm\u003c\/li\u003e\n \u003cli\u003eHousing: Nickel-plated brass, M18 standard\u003c\/li\u003e\n \u003cli\u003eMounting options: Flush or non-flush, short or long body versions\u003c\/li\u003e\n \u003cli\u003eOutput: DC 200 mA, NPN or PNP transistor, normally open or normally closed\u003c\/li\u003e\n \u003cli\u003eOperational voltage: 10 - 36 VDC\u003c\/li\u003e\n \u003cli\u003eLED indicator for output status\u003c\/li\u003e\n \u003cli\u003eProtection features: reverse polarity, short circuit, transients\u003c\/li\u003e\n \u003cli\u003eConnection types: Cable or M12 plug\u003c\/li\u003e\n \u003cli\u003eCompliance: IEC 60947-5-2, CSA certified for Hazardous Locations\u003c\/li\u003e\n \u003cli\u003ePart Number: ICB18L50N08NO\u003c\/li\u003e\n \u003cli\u003eManufacturer: CARLO GAVAZZI\u003c\/li\u003e\n \u003cli\u003eCountry of Origin: LT (Lithuania)\u003c\/li\u003e\n \u003cli\u003eUnit of Measure: Each (EA)\u003c\/li\u003e\n \u003cli\u003eECCN: EAR99\u003c\/li\u003e\n \u003cli\u003ePackage Type: Box\u003c\/li\u003e\n \u003cli\u003eDatasheet: \u003ca href=\"http:\/\/cga.pub\/?73a3b3\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n \u003ctr\u003e\n \u003cth\u003eType\u003c\/th\u003e\n \u003cth\u003eConnection Style\u003c\/th\u003e\n \u003cth\u003eSensing Distance\u003c\/th\u003e\n \u003cth\u003eOutput\u003c\/th\u003e\n \u003cth\u003eRated Operational Voltage (Ub)\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eInductive Proximity Sensor\u003c\/td\u003e\n \u003ctd\u003eCable \/ M12 Plug\u003c\/td\u003e\n \u003ctd\u003e8 mm (non-flush)\u003c\/td\u003e\n \u003ctd\u003eNPN or PNP, Normally Open\/Closed\u003c\/td\u003e\n \u003ctd\u003e10 - 36 VDC\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd colspan=\"5\"\u003eNote: For detailed specifications, please refer to the datasheet.\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDimensions (mm)\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n \u003ctr\u003e\n \u003cth\u003eBody Length\u003c\/th\u003e\n \u003cth\u003eDiameter\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e74.0 mm (Long body, flush version, plug)\u003c\/td\u003e\n \u003ctd\u003e18 mm (M18)\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation \u0026amp; Wiring\u003c\/h3\u003e\n\u003cp\u003eProper installation is critical for optimal sensor performance. When installing flush sensors in damping material, follow the guidelines provided in the datasheet. Maintain a minimum space of 6 x sensing distance (S\u003csub\u003en\u003c\/sub\u003e) when sensors are installed opposite each other. Wiring diagrams are available to ensure correct electrical connections.\u003c\/p\u003e\n\n\u003ch3\u003eAdditional Information\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eAccessories for plug versions are available; refer to the \"General Accessories - Connector Cables - Type CONB1...\" datasheets for options.\u003c\/li\u003e\n \u003cli\u003eDelivery includes the inductive proximity switch, 2 nuts (NPB), and packaging in a plastic bag.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eFor more detailed technical information, please consult the \u003ca href=\"http:\/\/cga.pub\/?73a3b3\" target=\"_blank\"\u003edatasheet\u003c\/a\u003e. Note: The datasheet content provided is based on available data; for comprehensive specifications, visit the manufacturer's website or contact Think Robotics.\u003c\/p\u003e"}
Unfortunately I havent tested the 5G, Only difficult part was connecting antennas. But everything is good, by default it runs on Qualcom's QMI mode, Had to switch to MBIM and it works good with Windows. Planning to run with OpenWRT soon.