CARLO GAVAZZI ICB18L50N14POM1 Inductive Proximity Sensor - 14mm Sensing Distance
The CARLO GAVAZZI ICB18L50N14POM1 is a high-performance inductive proximity sensor designed for industrial automation applications. Manufactured in Lithuania, this sensor features a robust nickel-plated brass housing suitable for demanding environments. It offers extended sensing range capabilities, making it ideal for applications requiring reliable detection over distances up to 14 mm.
Product Features
Sensing distance: 8 to 14 mm
Housing: Nickel-plated brass for durability and corrosion resistance
Type: Inductive proximity sensor, M18 size
Output: DC 200 mA, available as NPN or PNP
Configuration: Normally open or normally closed contacts
Power supply: 10 - 36 VDC rated operational voltage (Ub)
Installation options: Cable or M12 plug versions
Protection features: Reverse polarity, short circuit, and transient protection
LED indicator for output status
Compliance: According to IEC 60947-5-2, CSA certified for hazardous locations
Package: Box
ECCN: EAR99
UOM: Each
Technical Specifications
Parameter
Details
Sensing Distance
8 to 14 mm
Rated Operational Voltage (Ub)
10 - 36 VDC
Output Current
DC 200 mA
Housing Material
Nickel-plated brass
Installation Types
Cable or M12 plug
Protection Features
Reverse polarity, short circuit, transients
Compliance
IEC 60947-5-2, CSA certified for hazardous locations
Dimensions (mm)
Dimension
Value
Length
74.0 mm (long body, flush version, plug)
Diameter
18 mm (M18)
Wiring and Installation
Proper installation is crucial for optimal sensor performance. Flush sensors should be installed according to the specified damping material guidelines, while non-flush sensors require different mounting considerations. When installed opposite each other, maintain a minimum space of 6 times the sensing distance (Sn).
Additional Information
For detailed wiring diagrams, reduction factors, and accessory options, please refer to the datasheet.
Part Details
Part Number: ICB18L50N14POM1
Manufacturer: CARLO GAVAZZI
Country of Origin: LT (Lithuania)
Package Type: BOX
UOM: EA
ECCN: EAR99
Note: Datasheet was not processed, please search the internet for the part number for more details.
Unfortunately I havent tested the 5G, Only difficult part was connecting antennas. But everything is good, by default it runs on Qualcom's QMI mode, Had to switch to MBIM and it works good with Windows. Planning to run with OpenWRT soon.
{"id":10021355127101,"title":"ICB18L50N14POM1","handle":"icb18l50n14pom1","description":"\u003ch3\u003eCARLO GAVAZZI ICB18L50N14POM1 Inductive Proximity Sensor - 14mm Sensing Distance\u003c\/h3\u003e\n\n\u003cp\u003eThe CARLO GAVAZZI ICB18L50N14POM1 is a high-performance inductive proximity sensor designed for industrial automation applications. Manufactured in Lithuania, this sensor features a robust nickel-plated brass housing suitable for demanding environments. It offers extended sensing range capabilities, making it ideal for applications requiring reliable detection over distances up to 14 mm.\u003c\/p\u003e\n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eSensing distance: 8 to 14 mm\u003c\/li\u003e\n \u003cli\u003eHousing: Nickel-plated brass for durability and corrosion resistance\u003c\/li\u003e\n \u003cli\u003eType: Inductive proximity sensor, M18 size\u003c\/li\u003e\n \u003cli\u003eOutput: DC 200 mA, available as NPN or PNP\u003c\/li\u003e\n \u003cli\u003eConfiguration: Normally open or normally closed contacts\u003c\/li\u003e\n \u003cli\u003ePower supply: 10 - 36 VDC rated operational voltage (Ub)\u003c\/li\u003e\n \u003cli\u003eInstallation options: Cable or M12 plug versions\u003c\/li\u003e\n \u003cli\u003eProtection features: Reverse polarity, short circuit, and transient protection\u003c\/li\u003e\n \u003cli\u003eLED indicator for output status\u003c\/li\u003e\n \u003cli\u003eCompliance: According to IEC 60947-5-2, CSA certified for hazardous locations\u003c\/li\u003e\n \u003cli\u003ePackage: Box\u003c\/li\u003e\n \u003cli\u003eECCN: EAR99\u003c\/li\u003e\n \u003cli\u003eUOM: Each\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n \u003ctr\u003e\n \u003cth\u003eParameter\u003c\/th\u003e\n \u003cth\u003eDetails\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eSensing Distance\u003c\/td\u003e\n \u003ctd\u003e8 to 14 mm\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eRated Operational Voltage (Ub)\u003c\/td\u003e\n \u003ctd\u003e10 - 36 VDC\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eOutput Current\u003c\/td\u003e\n \u003ctd\u003eDC 200 mA\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eHousing Material\u003c\/td\u003e\n \u003ctd\u003eNickel-plated brass\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eInstallation Types\u003c\/td\u003e\n \u003ctd\u003eCable or M12 plug\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eProtection Features\u003c\/td\u003e\n \u003ctd\u003eReverse polarity, short circuit, transients\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eCompliance\u003c\/td\u003e\n \u003ctd\u003eIEC 60947-5-2, CSA certified for hazardous locations\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDimensions (mm)\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n \u003ctr\u003e\n \u003cth\u003eDimension\u003c\/th\u003e\n \u003cth\u003eValue\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eLength\u003c\/td\u003e\n \u003ctd\u003e74.0 mm (long body, flush version, plug)\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eDiameter\u003c\/td\u003e\n \u003ctd\u003e18 mm (M18)\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWiring and Installation\u003c\/h3\u003e\n\u003cp\u003eProper installation is crucial for optimal sensor performance. Flush sensors should be installed according to the specified damping material guidelines, while non-flush sensors require different mounting considerations. When installed opposite each other, maintain a minimum space of 6 times the sensing distance (S\u003csub\u003en\u003c\/sub\u003e).\u003c\/p\u003e\n\n\u003ch3\u003eAdditional Information\u003c\/h3\u003e\n\u003cp\u003eFor detailed wiring diagrams, reduction factors, and accessory options, please refer to the \u003ca href=\"http:\/\/gavazziautomation.com\/images\/PIM\/DATASHEET\/ENG\/ICB18x30_08.pdf\" target=\"_blank\"\u003edatasheet\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch3\u003ePart Details\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003ePart Number: ICB18L50N14POM1\u003c\/li\u003e\n \u003cli\u003eManufacturer: CARLO GAVAZZI\u003c\/li\u003e\n \u003cli\u003eCountry of Origin: LT (Lithuania)\u003c\/li\u003e\n \u003cli\u003ePackage Type: BOX\u003c\/li\u003e\n \u003cli\u003eUOM: EA\u003c\/li\u003e\n \u003cli\u003eECCN: EAR99\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Datasheet was not processed, please search the internet for the part number for more details.\u003c\/p\u003e","published_at":"2025-08-12T15:46:41+05:30","created_at":"2025-08-12T15:46:41+05:30","vendor":"Waldom Electonics","type":"Sensors\/Transducers","tags":["14MM","CARLO","IMPORT_CSV","PROX","Proximity","Sensors","Transducers","WLDM"],"price":725247,"price_min":725247,"price_max":725247,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50612237074749,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"ICB18L50N14POM1","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"ICB18L50N14POM1","public_title":null,"options":["Default Title"],"price":725247,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"ICB18L50N14POM1","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/49101833.jpg?v=1754993803"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/49101833.jpg?v=1754993803","options":["Title"],"media":[{"alt":null,"id":45801639969085,"position":1,"preview_image":{"aspect_ratio":1.0,"height":420,"width":420,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/49101833.jpg?v=1754993803"},"aspect_ratio":1.0,"height":420,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/49101833.jpg?v=1754993803","width":420}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eCARLO GAVAZZI ICB18L50N14POM1 Inductive Proximity Sensor - 14mm Sensing Distance\u003c\/h3\u003e\n\n\u003cp\u003eThe CARLO GAVAZZI ICB18L50N14POM1 is a high-performance inductive proximity sensor designed for industrial automation applications. Manufactured in Lithuania, this sensor features a robust nickel-plated brass housing suitable for demanding environments. It offers extended sensing range capabilities, making it ideal for applications requiring reliable detection over distances up to 14 mm.\u003c\/p\u003e\n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eSensing distance: 8 to 14 mm\u003c\/li\u003e\n \u003cli\u003eHousing: Nickel-plated brass for durability and corrosion resistance\u003c\/li\u003e\n \u003cli\u003eType: Inductive proximity sensor, M18 size\u003c\/li\u003e\n \u003cli\u003eOutput: DC 200 mA, available as NPN or PNP\u003c\/li\u003e\n \u003cli\u003eConfiguration: Normally open or normally closed contacts\u003c\/li\u003e\n \u003cli\u003ePower supply: 10 - 36 VDC rated operational voltage (Ub)\u003c\/li\u003e\n \u003cli\u003eInstallation options: Cable or M12 plug versions\u003c\/li\u003e\n \u003cli\u003eProtection features: Reverse polarity, short circuit, and transient protection\u003c\/li\u003e\n \u003cli\u003eLED indicator for output status\u003c\/li\u003e\n \u003cli\u003eCompliance: According to IEC 60947-5-2, CSA certified for hazardous locations\u003c\/li\u003e\n \u003cli\u003ePackage: Box\u003c\/li\u003e\n \u003cli\u003eECCN: EAR99\u003c\/li\u003e\n \u003cli\u003eUOM: Each\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n \u003ctr\u003e\n \u003cth\u003eParameter\u003c\/th\u003e\n \u003cth\u003eDetails\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eSensing Distance\u003c\/td\u003e\n \u003ctd\u003e8 to 14 mm\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eRated Operational Voltage (Ub)\u003c\/td\u003e\n \u003ctd\u003e10 - 36 VDC\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eOutput Current\u003c\/td\u003e\n \u003ctd\u003eDC 200 mA\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eHousing Material\u003c\/td\u003e\n \u003ctd\u003eNickel-plated brass\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eInstallation Types\u003c\/td\u003e\n \u003ctd\u003eCable or M12 plug\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eProtection Features\u003c\/td\u003e\n \u003ctd\u003eReverse polarity, short circuit, transients\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eCompliance\u003c\/td\u003e\n \u003ctd\u003eIEC 60947-5-2, CSA certified for hazardous locations\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDimensions (mm)\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n \u003ctr\u003e\n \u003cth\u003eDimension\u003c\/th\u003e\n \u003cth\u003eValue\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eLength\u003c\/td\u003e\n \u003ctd\u003e74.0 mm (long body, flush version, plug)\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eDiameter\u003c\/td\u003e\n \u003ctd\u003e18 mm (M18)\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWiring and Installation\u003c\/h3\u003e\n\u003cp\u003eProper installation is crucial for optimal sensor performance. Flush sensors should be installed according to the specified damping material guidelines, while non-flush sensors require different mounting considerations. When installed opposite each other, maintain a minimum space of 6 times the sensing distance (S\u003csub\u003en\u003c\/sub\u003e).\u003c\/p\u003e\n\n\u003ch3\u003eAdditional Information\u003c\/h3\u003e\n\u003cp\u003eFor detailed wiring diagrams, reduction factors, and accessory options, please refer to the \u003ca href=\"http:\/\/gavazziautomation.com\/images\/PIM\/DATASHEET\/ENG\/ICB18x30_08.pdf\" target=\"_blank\"\u003edatasheet\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch3\u003ePart Details\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003ePart Number: ICB18L50N14POM1\u003c\/li\u003e\n \u003cli\u003eManufacturer: CARLO GAVAZZI\u003c\/li\u003e\n \u003cli\u003eCountry of Origin: LT (Lithuania)\u003c\/li\u003e\n \u003cli\u003ePackage Type: BOX\u003c\/li\u003e\n \u003cli\u003eUOM: EA\u003c\/li\u003e\n \u003cli\u003eECCN: EAR99\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Datasheet was not processed, please search the internet for the part number for more details.\u003c\/p\u003e"}