{"product_id":"king-pigeon-m420t-modbus-tcp-server-data-acquisition-io-module-16-do","title":"King Pigeon M420T Modbus TCP Server Data Acquisition IO Module, 16 DO","description":"\u003cdiv style=\"text-align: center;\"\u003e\n\u003ch2\u003eKing Pigeon M420T Ethernet Remote I\/O Module\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e16 digital outputs over Modbus TCP\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg alt=\"King Pigeon M420T product image 1\" src=\"https:\/\/alexnld.com\/wp-content\/uploads\/2023\/03\/959bd956-5378-435c-a626-8f35e37692b1-11486122.jpg\" style=\"display: block; width: 100%; max-width: 600px; height: auto; margin: 16px auto;\"\u003e\n\u003cp\u003eThe M420T puts 16 digital outputs on your Ethernet network. It is an industrial, isolated data acquisition module with standard Modbus TCP, so SCADA, OPC servers and other automation systems can switch field devices directly. An RS485 port lets it control extra Modbus RTU I\/O modules and meters, saving a separate gateway.\u003c\/p\u003e\n\u003cimg alt=\"King Pigeon M420T product image 2\" src=\"https:\/\/alexnld.com\/wp-content\/uploads\/2023\/03\/30b8237c-5bd2-46b9-945d-953779ccbb0d-11486122.jpg\" style=\"display: block; width: 100%; max-width: 600px; height: auto; margin: 16px auto;\"\u003e\n\u003cimg alt=\"King Pigeon M420T product image 3\" src=\"https:\/\/alexnld.com\/wp-content\/uploads\/2023\/03\/13ba76d2-ee18-4d45-9c2b-a73c316986c9-11486122.jpg\" style=\"display: block; width: 100%; max-width: 600px; height: auto; margin: 16px auto;\"\u003e\n\u003cimg alt=\"King Pigeon M420T product image 4\" src=\"https:\/\/alexnld.com\/wp-content\/uploads\/2023\/03\/099ecb65-b5a2-4e0b-bc54-a6b3df07cee8-11486122.jpg\" style=\"display: block; width: 100%; max-width: 600px; height: auto; margin: 16px auto;\"\u003e\n\u003cimg alt=\"King Pigeon M420T product image 5\" src=\"https:\/\/alexnld.com\/wp-content\/uploads\/2023\/03\/a0ee4bcd-d393-45e7-8831-3b7dabdce8f0-11486122.jpg\" style=\"display: block; width: 100%; max-width: 600px; height: auto; margin: 16px auto;\"\u003e\n\u003cimg alt=\"King Pigeon M420T product image 6\" src=\"https:\/\/alexnld.com\/wp-content\/uploads\/2023\/03\/55222dc1-277e-4855-a0d4-85b0c5726744-11486122.jpg\" style=\"display: block; width: 100%; max-width: 600px; height: auto; margin: 16px auto;\"\u003e\n\u003cimg alt=\"King Pigeon M420T product image 7\" src=\"https:\/\/alexnld.com\/wp-content\/uploads\/2023\/03\/61749607-50b6-4402-ad07-93b5b6cbfb3d-11486122.jpg\" style=\"display: block; width: 100%; max-width: 600px; height: auto; margin: 16px auto;\"\u003e\n\u003cimg alt=\"King Pigeon M420T product image 8\" src=\"https:\/\/alexnld.com\/wp-content\/uploads\/2023\/03\/ef6f985f-8f91-4509-b06e-f8b9d641adce-11486122.jpg\" style=\"display: block; width: 100%; max-width: 600px; height: auto; margin: 16px auto;\"\u003e\n\u003cimg alt=\"King Pigeon M420T product image 9\" src=\"https:\/\/alexnld.com\/wp-content\/uploads\/2023\/03\/fcbfbdac-951d-4630-a6eb-764a9fa5897f-11486122.jpg\" style=\"display: block; width: 100%; max-width: 600px; height: auto; margin: 16px auto;\"\u003e\n\u003cimg alt=\"King Pigeon M420T product image 10\" src=\"https:\/\/alexnld.com\/wp-content\/uploads\/2023\/03\/567ccaf0-b1f2-4691-8054-a4d5b491057c-11486122.jpg\" style=\"display: block; width: 100%; max-width: 600px; height: auto; margin: 16px auto;\"\u003e\n\u003cimg alt=\"King Pigeon M420T product image 11\" src=\"https:\/\/alexnld.com\/wp-content\/uploads\/2023\/03\/178dde6e-880d-4d8d-9a56-c4255c3f3a4e-11486122.jpg\" style=\"display: block; width: 100%; max-width: 600px; height: auto; margin: 16px auto;\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse; margin: 0 auto; text-align: center;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center; width: 40%;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"text-align: center;\"\u003eKing Pigeon M420T\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"text-align: center; background: rgba(128, 128, 128, 0.25); color: inherit;\"\u003eOutputs\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eDigital Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e16, sink type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003ePulse Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e10 Hz to 300 kHz, first channel only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"text-align: center; background: rgba(128, 128, 128, 0.25); color: inherit;\"\u003eCommunication\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eEthernet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1 × RJ45, 10\/100M adaptive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eProtocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eModbus TCP, Modbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eTCP Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eUp to 5 clients\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eSerial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1 × RS485, Modbus RTU master or slave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eEmbedded web server\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"text-align: center; background: rgba(128, 128, 128, 0.25); color: inherit;\"\u003ePower and Housing\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e12–36 V DC, with over-voltage and reverse-polarity protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eTypical Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e110 mA at 12 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003ePower Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1 channel, 12–36 V DC, for external devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eProcessor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e32-bit MCU with watchdog\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eHousing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eMetal, IP30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eIn the Box\u003c\/h2\u003e\n\u003cp\u003e1 × M420T Ethernet Remote I\/O Module\u003c\/p\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/tinyurl.com\/3s3jrksv\/20201016\/20201016065647MxxxTUserManualV2.0.pdf\" rel=\"noopener\" target=\"_blank\"\u003eManual: Click here to open\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/tinyurl.com\/3s3jrksv\/20201016\/20201016065657MxxxTV1.0.rar\" rel=\"noopener\" target=\"_blank\"\u003eTool: Click here to open\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eSummary\u003c\/h2\u003e\n\u003cp\u003eThe King Pigeon M420T is a compact Modbus TCP remote I\/O module with 16 sink digital outputs, 300 kHz pulse output on channel 1, an RS485 expansion port and a 12–36 V DC supply, for controlling field devices over Ethernet.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"DOBOT","offers":[{"title":"Default Title","offer_id":68119970414909,"sku":"DBR079","price":21499.99,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0014\/4313\/5560\/files\/75f12266-e947-42c8-bef9-2c312502c437.jpg?v=1795080725","url":"https:\/\/thinkrobotics.com\/products\/king-pigeon-m420t-modbus-tcp-server-data-acquisition-io-module-16-do","provider":"ThinkRobotics by Atlantis Robotics","version":"1.0","type":"link"}