The CARLO GAVAZZI VTI3 is a conductive liquid level sensor designed for precise measurement of conductive liquids, making it ideal for maximum and minimum level control, as well as charging and discharging operations. This sensor features a robust Teflon housing, ensuring excellent chemical resistance and durability in harsh environments.
Part Number: VTI3 Manufacturer: CARLO GAVAZZI Country of Origin: LT (Lithuania) UOM: EA ECCN: EAR99 Package Type: BOX Datasheet
Product Features
Suitable for measuring the level of conductive liquids with maximum/minimum control
Delivered with standard length electrodes, customizable by cutting to suit specific applications
Constructed with a Teflon housing for excellent chemical resistance
Available with 1 to 4 electrodes, either isolated (Teflon) or unisolated
Includes cable connection options
Designed with a 1 1/2” pipe thread according to ISO 228-1
Product Specifications
Type
Isolated
Number of electrodes
1 to 4 electrodes
Pipe thread
1 1/2” ISO 228-1
Electrode material
Various options available, see datasheet
Additional Details
The length of electrodes determines the detection levels
The amplifier relay used defines the sensor's function (see CLP2EA1Cxxx or CLP2FA1Bxxx)
If the container is made of a conductive material, it can serve as a common electrode
Extension joint for Ø5 mm electrodes available (VD1)
For more detailed specifications and application information, please refer to the datasheet. The product specifications are subject to change without notice. Please search the internet for the part number VTI3 for the latest details.
Use left/right arrows to navigate the slideshow or swipe left/right if using a mobile device
Choosing a selection results in a full page refresh.
Press the space key then arrow keys to make a selection.
Shopping Cart
{"id":10022755664189,"title":"VTI3","handle":"vti3","description":"\u003ch3\u003eCARLO GAVAZZI VTI3 Sensor Level\u003c\/h3\u003e\n\u003cp\u003eThe CARLO GAVAZZI VTI3 is a conductive liquid level sensor designed for precise measurement of conductive liquids, making it ideal for maximum and minimum level control, as well as charging and discharging operations. This sensor features a robust Teflon housing, ensuring excellent chemical resistance and durability in harsh environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e VTI3\u003cbr\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e CARLO GAVAZZI\u003cbr\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e LT (Lithuania)\u003cbr\u003e\n\u003cstrong\u003eUOM:\u003c\/strong\u003e EA\u003cbr\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e EAR99\u003cbr\u003e\n\u003cstrong\u003ePackage Type:\u003c\/strong\u003e BOX\u003cbr\u003e\n\u003ca href=\"http:\/\/cga.pub\/?c286a8\" target=\"_blank\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSuitable for measuring the level of conductive liquids with maximum\/minimum control\u003c\/li\u003e\n\u003cli\u003eDelivered with standard length electrodes, customizable by cutting to suit specific applications\u003c\/li\u003e\n\u003cli\u003eConstructed with a Teflon housing for excellent chemical resistance\u003c\/li\u003e\n\u003cli\u003eAvailable with 1 to 4 electrodes, either isolated (Teflon) or unisolated\u003c\/li\u003e\n\u003cli\u003eIncludes cable connection options\u003c\/li\u003e\n\u003cli\u003eDesigned with a 1 1\/2” pipe thread according to ISO 228-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003cth\u003eIsolated\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of electrodes\u003c\/td\u003e\n\u003ctd\u003e1 to 4 electrodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePipe thread\u003c\/td\u003e\n\u003ctd\u003e1 1\/2” ISO 228-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode material\u003c\/td\u003e\n\u003ctd\u003eVarious options available, see datasheet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAdditional Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe length of electrodes determines the detection levels\u003c\/li\u003e\n\u003cli\u003eThe amplifier relay used defines the sensor's function (see CLP2EA1Cxxx or CLP2FA1Bxxx)\u003c\/li\u003e\n\u003cli\u003eIf the container is made of a conductive material, it can serve as a common electrode\u003c\/li\u003e\n\u003cli\u003eExtension joint for Ø5 mm electrodes available (VD1)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor more detailed specifications and application information, please refer to the \u003ca href=\"http:\/\/cga.pub\/?c286a8\" target=\"_blank\"\u003edatasheet\u003c\/a\u003e. The product specifications are subject to change without notice. Please search the internet for the part number VTI3 for the latest details.\u003c\/p\u003e","published_at":"2025-08-13T13:18:48+05:30","created_at":"2025-08-13T13:18:48+05:30","vendor":"Waldom Electonics","type":"Sensors\/Transducers","tags":["CARLO","IMPORT_CSV","Liquid","Sensors","Transducers","WLDM"],"price":7536301,"price_min":7536301,"price_max":7536301,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50615078748477,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"VTI3","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"VTI3","public_title":null,"options":["Default Title"],"price":7536301,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"VTI3","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/11062714.png?v=1755071331"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/11062714.png?v=1755071331","options":["Title"],"media":[{"alt":null,"id":45816184668477,"position":1,"preview_image":{"aspect_ratio":1.0,"height":400,"width":400,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/11062714.png?v=1755071331"},"aspect_ratio":1.0,"height":400,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/11062714.png?v=1755071331","width":400}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eCARLO GAVAZZI VTI3 Sensor Level\u003c\/h3\u003e\n\u003cp\u003eThe CARLO GAVAZZI VTI3 is a conductive liquid level sensor designed for precise measurement of conductive liquids, making it ideal for maximum and minimum level control, as well as charging and discharging operations. This sensor features a robust Teflon housing, ensuring excellent chemical resistance and durability in harsh environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e VTI3\u003cbr\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e CARLO GAVAZZI\u003cbr\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e LT (Lithuania)\u003cbr\u003e\n\u003cstrong\u003eUOM:\u003c\/strong\u003e EA\u003cbr\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e EAR99\u003cbr\u003e\n\u003cstrong\u003ePackage Type:\u003c\/strong\u003e BOX\u003cbr\u003e\n\u003ca href=\"http:\/\/cga.pub\/?c286a8\" target=\"_blank\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSuitable for measuring the level of conductive liquids with maximum\/minimum control\u003c\/li\u003e\n\u003cli\u003eDelivered with standard length electrodes, customizable by cutting to suit specific applications\u003c\/li\u003e\n\u003cli\u003eConstructed with a Teflon housing for excellent chemical resistance\u003c\/li\u003e\n\u003cli\u003eAvailable with 1 to 4 electrodes, either isolated (Teflon) or unisolated\u003c\/li\u003e\n\u003cli\u003eIncludes cable connection options\u003c\/li\u003e\n\u003cli\u003eDesigned with a 1 1\/2” pipe thread according to ISO 228-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003cth\u003eIsolated\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of electrodes\u003c\/td\u003e\n\u003ctd\u003e1 to 4 electrodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePipe thread\u003c\/td\u003e\n\u003ctd\u003e1 1\/2” ISO 228-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode material\u003c\/td\u003e\n\u003ctd\u003eVarious options available, see datasheet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAdditional Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe length of electrodes determines the detection levels\u003c\/li\u003e\n\u003cli\u003eThe amplifier relay used defines the sensor's function (see CLP2EA1Cxxx or CLP2FA1Bxxx)\u003c\/li\u003e\n\u003cli\u003eIf the container is made of a conductive material, it can serve as a common electrode\u003c\/li\u003e\n\u003cli\u003eExtension joint for Ø5 mm electrodes available (VD1)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor more detailed specifications and application information, please refer to the \u003ca href=\"http:\/\/cga.pub\/?c286a8\" target=\"_blank\"\u003edatasheet\u003c\/a\u003e. The product specifications are subject to change without notice. Please search the internet for the part number VTI3 for the latest details.\u003c\/p\u003e"}
Unfortunately I havent tested the 5G, Only difficult part was connecting antennas. But everything is good, by default it runs on Qualcom's QMI mode, Had to switch to MBIM and it works good with Windows. Planning to run with OpenWRT soon.