Probe/load impact on RC circuit calculator

Enter a decimal or scientific notation, such as 4.7 or 4.7e3. Changing a unit reinterprets its number.

The resistance driving the node, for example a pull-up or a source's output resistance.

The node's own capacitance to ground; enter 0 if it has none.

Values from the Tektronix P2220 data sheet. Choose Custom or edit them for your probe. Enter the resistance in MΩ: 500 Ω is 0.0005 MΩ.

Enter the source resistance and node capacitance to see the probe's effect.

No valid result to draw.

Show the steps

Interactive calculation is unavailable until JavaScript loads. The formulas, worked examples and references below remain available.

Estimate how an oscilloscope probe's resistance and capacitance load a circuit node: DC error, new time constant, bandwidth and rise-time change.

How to use

Enter the node's source resistance and its own capacitance.

Choose a 10× or 1× passive probe, or Custom, and check the probe resistance and capacitance against your probe's data sheet.

Read the rise time with the probe and how much it changed, then the DC error, time constants and bandwidths.

Use the step-response chart to compare the node with and without the probe.

Copy result copies labelled values; Reset restores the starting fields.

Science

A passive probe looks like a resistance in parallel with a capacitance. The resistance forms a divider with the node's source resistance, which lowers the DC reading only when the source resistance is a noticeable fraction of the probe's 1 or 10 MΩ.

The capacitance adds to the node's own capacitance. With the source resistance it sets a time constant τ = (R_S × R_P) ÷ (R_S + R_P) × (C_N + C_P), so a step reaches 90 % later: the 10–90 % rise time is ln 9 ≈ 2.2 time constants, and the −3 dB bandwidth is 1 / (2πτ). Their product is about 0.35, the same rule oscilloscopes use.

A 10× probe has about a tenth of the capacitance of a 1× probe, so on fast or high-impedance nodes it disturbs the circuit far less, at the cost of a tenth of the signal at the scope. Low-capacitance probes of a few picofarads reduce the effect further.

Limitations: the probe and node are modelled as a single resistance and capacitance. Ground-lead inductance, the probe cable, compensation, the probe's and scope's own bandwidth, and circuits that are not a simple RC (active outputs, transmission lines, resonances) are not modelled, and preset values are one probe's data-sheet figures, not yours.

Formulas

Parallel resistance: R_EQ = R_S × R_P / (R_S + R_P).

DC error: Error = -R_S / (R_S + R_P).

Time constant: τ = R_S × C_N without the probe; τ = R_EQ × (C_N + C_P) with it.

Rise time: t_r = ln 9 × τ ≈ 2.197 τ (10 % to 90 %).

Bandwidth: f_c = 1 / (2π × τ).

Rule: f_c × t_r = ln 9 / (2π) ≈ 0.35.

Examples

10 kΩ source, 10 pF node, 10× probe (10 MΩ, 17 pF): Rise time 219.722 ns → 592.658 ns (+169.73 %); bandwidth 1.59155 MHz → 590.052 kHz; DC error -0.0999 %. τ goes from 10 kΩ × 10 pF = 100 ns to 9.99 kΩ × 27 pF = 269.73 ns.

Same node, 1× probe (1 MΩ, 110 pF): Rise time 2.61056 μs (+1088.12 %); DC error -0.990 %. Common mistake: leaving a switchable probe on 1× for a fast node.

50 Ω source, 20 pF node, probe 10 MΩ × 11 pF: 2.19722 ns → 3.40568 ns (+55 %). The ABCs of Probes example, which rounds ln 9 to 2.2: 2.2 ns → 3.4 ns.

1 MΩ source, 5 pF node, 10× probe: DC error -9.09091 %; rise time 10.9861 μs → 43.9445 μs (+300 %). High-impedance nodes suffer both DC and AC loading.

1 kΩ source, node 0 pF, 10× probe: The probe alone sets 37.3491 ns (9.36299 MHz). Boundary: an ideal node has no rise time of its own, so no percentage change exists.

References

Tektronix: ABCs of probes

Tektronix P2220/P2221 passive probe data sheet

Tektronix P2220 instructions

OpenStax University Physics Volume 2: 10.5 RC circuits

TI SLOA032: first-order RC low-pass filter