Electrical Energy Calculator
Calculate electricity use from power and duration, or constant DC voltage and current. Compare energy use over different operating times in watt-hours, kilowatt-hours and joules.
Open toolInteractive calculation is unavailable until JavaScript loads. The formulas, worked examples and references below remain available.
Estimate how an oscilloscope probe's resistance and capacitance load a circuit node: DC error, new time constant, bandwidth and rise-time change.
Enter the node's source resistance and its own capacitance.
Choose a 10× or 1× passive probe, or Custom, and check the probe resistance and capacitance against your probe's data sheet.
Read the rise time with the probe and how much it changed, then the DC error, time constants and bandwidths.
Use the step-response chart to compare the node with and without the probe.
Copy result copies labelled values; Reset restores the starting fields.
A passive probe looks like a resistance in parallel with a capacitance. The resistance forms a divider with the node's source resistance, which lowers the DC reading only when the source resistance is a noticeable fraction of the probe's 1 or 10 MΩ.
The capacitance adds to the node's own capacitance. With the source resistance it sets a time constant τ = (R_S × R_P) ÷ (R_S + R_P) × (C_N + C_P), so a step reaches 90 % later: the 10–90 % rise time is ln 9 ≈ 2.2 time constants, and the −3 dB bandwidth is 1 / (2πτ). Their product is about 0.35, the same rule oscilloscopes use.
A 10× probe has about a tenth of the capacitance of a 1× probe, so on fast or high-impedance nodes it disturbs the circuit far less, at the cost of a tenth of the signal at the scope. Low-capacitance probes of a few picofarads reduce the effect further.
Limitations: the probe and node are modelled as a single resistance and capacitance. Ground-lead inductance, the probe cable, compensation, the probe's and scope's own bandwidth, and circuits that are not a simple RC (active outputs, transmission lines, resonances) are not modelled, and preset values are one probe's data-sheet figures, not yours.
Parallel resistance: R_EQ = R_S × R_P / (R_S + R_P).
DC error: Error = -R_S / (R_S + R_P).
Time constant: τ = R_S × C_N without the probe; τ = R_EQ × (C_N + C_P) with it.
Rise time: t_r = ln 9 × τ ≈ 2.197 τ (10 % to 90 %).
Bandwidth: f_c = 1 / (2π × τ).
Rule: f_c × t_r = ln 9 / (2π) ≈ 0.35.
10 kΩ source, 10 pF node, 10× probe (10 MΩ, 17 pF): Rise time 219.722 ns → 592.658 ns (+169.73 %); bandwidth 1.59155 MHz → 590.052 kHz; DC error -0.0999 %. τ goes from 10 kΩ × 10 pF = 100 ns to 9.99 kΩ × 27 pF = 269.73 ns.
Same node, 1× probe (1 MΩ, 110 pF): Rise time 2.61056 μs (+1088.12 %); DC error -0.990 %. Common mistake: leaving a switchable probe on 1× for a fast node.
50 Ω source, 20 pF node, probe 10 MΩ × 11 pF: 2.19722 ns → 3.40568 ns (+55 %). The ABCs of Probes example, which rounds ln 9 to 2.2: 2.2 ns → 3.4 ns.
1 MΩ source, 5 pF node, 10× probe: DC error -9.09091 %; rise time 10.9861 μs → 43.9445 μs (+300 %). High-impedance nodes suffer both DC and AC loading.
1 kΩ source, node 0 pF, 10× probe: The probe alone sets 37.3491 ns (9.36299 MHz). Boundary: an ideal node has no rise time of its own, so no percentage change exists.
Tektronix P2220/P2221 passive probe data sheet
Available now
Calculate electricity use from power and duration, or constant DC voltage and current. Compare energy use over different operating times in watt-hours, kilowatt-hours and joules.
Open tool →Available now
Add up to 20 resistors in series using Ω, kΩ or MΩ for circuit analysis and electricity calculations, with a diagram and running total.
Open tool →Available now
Convert absolute temperatures between Celsius, Fahrenheit and kelvin.
Open tool →Nice audio board working as expected.
Given the fact that this was my first purchase and I made it thinking I was buying genuine Yihua products, this has been a setback. I received a lesser known OEM brand called MYTO and while both the products seem to be similar from appearance, my real contention is the quality and quantity of the brass wool. On top of that not informing the customer about the unavailability of the Yihua product and instead sending a product from a different brand is also antagonising. Henceforth, I might just have to think twice before ordering from ThinkRobotics.
TOF MINIF Range Sensor - UART TOF Time-of-Flight Laser Range Sensor
We are disappointed with our recent order experience. We clearly communicated our requirement for 433 MHz antennas on WhatsApp, but the issue remains unresolved. We have been following up for more than 10 days and are still waiting for a proper refund resolution.
As a regular B2B customer, we expected better support. This experience has affected our trust in ThinkRobotics, and we may have to consider other suppliers for future purchases. We request a fair and prompt refund.
Anodised Aluminium Cup Head Washers (Pack of 10)