Electrical Energy Calculator
Calculate electricity use from power and duration, or constant DC voltage and current. Compare energy use over different operating times in watt-hours, kilowatt-hours and joules.
Open toolInteractive calculation is unavailable until JavaScript loads. The formulas and worked examples below remain available.
Calculate a percentage, compare a change or ratio, find tolerance limits, and measure absolute or relative error.
Choose Percentage of a value, Percentage change, Ratio, Tolerance band, or Absolute and relative error.
Enter the two labeled values in consistent units. Type numbers without unit symbols or percent signs, such as 5 for 5%.
Read the answer and supporting values. Change uses the starting magnitude, even for a negative start. Relative error is unavailable when the reference is zero.
Compare the values on one scale. Change its bounds or choose Fit values for values outside the view. These controls preserve the calculation.
Open Show the steps to see the substituted formula. Copy result includes the mode and inputs. Reset clears the inputs and restores the starting mode and view.
A percentage is a ratio per hundred. Multiplying by 15% means multiplying by 0.15. Negative percentages and percentages above 100% are valid arithmetic operations. Their meaning depends on the quantity.
Percentage change needs a starting reference. This tool divides the signed difference by the magnitude of the starting value. An upward change is positive even when the start is negative. A zero start cannot be a percentage denominator.
A ratio compares two values in a stated order. Swapping the order changes the quotient. A reduced integer ratio removes a common factor and preserves the comparison. Decimal ratios are shown numerically rather than approximated by integers.
A symmetric percentage tolerance sets two limits around a nominal value. The half-width uses the nominal magnitude, so the limits stay ordered for negative values. A zero nominal value needs an absolute allowance for a nonzero band. This percentage-only mode returns zero width.
Signed error shows direction. Absolute error magnitude shows distance from the chosen reference. Relative error divides that distance by the reference magnitude. A tolerance band and an error calculation do not establish measurement uncertainty or statistical confidence.
Percentage amount: amount = base × percentage/100
Percentage change: change (%) = 100 × (ending − starting)/|starting|
Ratio: quotient = A/B; percentage of B = 100 × A/B
Tolerance: half-width = |nominal| × tolerance/100; limits = nominal ± half-width
Error: signed error = measured − reference; absolute error magnitude = |signed error|
Relative error: relative error = absolute error magnitude/|reference|; percent error = 100 × relative error; reference must be nonzero.
15% of 200: 30. 200 × 0.15 = 30.
Start 100, end 120: +20%; difference +20. 100 × 20/100 = 20%.
Start −100, end −80: +20%; difference +20. Divide the upward difference by the starting magnitude, 100.
Ratio 12:18: 0.6666666667; 2:3; 66.66666667%. Both integers share a factor of 6.
Nominal 100, ±5%: 95 to 105; half-width 5. Five percent of 100 sets the symmetric limits.
Reference 100, measured 103: Absolute error 3; signed error +3; relative error 0.03; percent error 3%. The discrepancy is 3 out of a reference magnitude of 100.
Reference 0, measured 2: Absolute error 2; signed error +2; relative and percent error not defined. Zero cannot be the denominator of a relative comparison.
Available now
Calculate electricity use from power and duration, or constant DC voltage and current. Compare energy use over different operating times in watt-hours, kilowatt-hours and joules.
Open tool →Available now
Add up to 20 resistors in series using Ω, kΩ or MΩ for circuit analysis and electricity calculations, with a diagram and running total.
Open tool →Available now
Convert absolute temperatures between Celsius, Fahrenheit and kelvin.
Open tool →Given the fact that this was my first purchase and I made it thinking I was buying genuine Yihua products, this has been a setback. I received a lesser known OEM brand called MYTO and while both the products seem to be similar from appearance, my real contention is the quality and quantity of the brass wool. On top of that not informing the customer about the unavailability of the Yihua product and instead sending a product from a different brand is also antagonising. Henceforth, I might just have to think twice before ordering from ThinkRobotics.
TOF MINIF Range Sensor - UART TOF Time-of-Flight Laser Range Sensor
We are disappointed with our recent order experience. We clearly communicated our requirement for 433 MHz antennas on WhatsApp, but the issue remains unresolved. We have been following up for more than 10 days and are still waiting for a proper refund resolution.
As a regular B2B customer, we expected better support. This experience has affected our trust in ThinkRobotics, and we may have to consider other suppliers for future purchases. We request a fair and prompt refund.
Anodised Aluminium Cup Head Washers (Pack of 10)