SMD resistor-code decoder

Enter the code printed on a resistor. The decoder shows a supported interpretation and explains how each part contributes to the nominal resistance.

Type the characters without spaces or units. Lowercase letters are accepted.

Nominal resistance

Enter a resistor code to see its value.

Tolerance, power and voltage require the component datasheet.

Code to value

Each printed part is shown with its role. The arrow leads to the nominal value.

R = significant digits × 10^multiplier Ω, or R = EIA-96 table value × letter multiplier Ω

Show the steps
Code partRoleMeaning

For numeric codes, the last digit sets the power of ten. R marks a decimal point. EIA-96 uses a table index and a letter multiplier.

Enable JavaScript to decode a resistor code. Formulas and examples remain available below.

Decode three-digit, four-digit, R-decimal, zero-ohm and supported EIA-96 resistor markings.

How to use

Enter the resistor code without spaces or units. Lowercase letters are accepted.

Use Detect supported format, or select the marking scheme documented for your component.

Read the nominal resistance and its equivalents. Check the detected scheme against the component datasheet.

Open Show the steps to inspect the digits, decimal marker or EIA-96 lookup.

Use Copy result to include the code and scheme. Reset clears the code and restores the starting settings.

Science

Three-digit codes use two significant digits and a decimal multiplier. Four-digit codes use three significant digits and a multiplier.

R-decimal codes place R where the decimal point belongs. This tool interprets the resulting value in ohms.

EIA-96 uses two digits as a table index. A letter supplies the multiplier, so the two digits are not the significant resistance value.

This tool uses the Bourns CR EIA-96 table. Other markings require the manufacturer's own documentation.

A zero code identifies a nominal jumper. It does not mean the physical component has exactly zero resistance.

Code format alone does not establish tolerance, power or voltage ratings. Use the part's datasheet for those properties.

Formulas

Three digits: R = AB × 10^C Ω for code ABC.

Four digits: R = ABC × 10^D Ω for code ABCD.

EIA-96: R = table value × letter multiplier Ω.

Prefixes: 1 kΩ = 1000 Ω, 1 MΩ = 1000000 Ω.

Examples

472: 4.7 kΩ. 47 × 10² Ω.

1001: 1 kΩ. 100 × 10¹ Ω.

4R7: 4.7 Ω. R marks the decimal point.

000: 0 Ω nominal jumper. A nominal marking does not establish physical zero resistance.

01C in Bourns CR EIA-96: 10 kΩ. Code 01 maps to 100. C multiplies it by 100.

References

Bourns CR Series Thick Film Chip Resistors, revision 03/21

Bourns CRP0603 Precision Chip Resistors, 08/04

BIPM SI prefixes