Electrical Energy Calculator
Calculate electricity use from power and duration, or constant DC voltage and current. Compare energy use over different operating times in watt-hours, kilowatt-hours and joules.
Open toolInteractive calculation is unavailable until JavaScript loads. The formulas, worked examples and references below remain available.
Find quarter-, half- or full-bridge output from gauge factor and strain, strain from a measured output, or a load cell's output at a load from its rated output in mV/V.
Choose a task: strain to output, output to strain, load to output or output to load.
For strain, choose the bridge arrangement and enter the gauge factor from the gauge packet.
Enter the excitation voltage and the strain in microstrain (negative for compression), or the measured output in millivolts.
For a load cell, enter the rated output in mV/V, the rated capacity and unit, and the load or the measured output; enter the no-load output if the cell is not zeroed.
Read the output, strain or load and the secondary values. Copy result copies labeled values; Reset restores the starting fields.
A strain gauge's resistance changes in proportion to strain: ΔR/R is the gauge factor times the strain, about 2 for foil gauges. Because the change is tiny (0.2 % at 1000 με), gauges are read in a Wheatstone bridge, which turns it into a small voltage proportional to the excitation, quoted in mV/V.
With one active gauge (a quarter bridge) the output is not exactly linear: the gauge's own change unbalances the current in its arm. The error is about the gauge factor times the strain divided by two, about 0.1 % at 1000 με and 1 % at 10,000 με for a gauge factor of 2. Two gauges with equal and opposite strain in adjacent arms (bending), or four in opposite pairs, cancel that term and are exactly linear, with two and four times the output.
A load cell is a full bridge inside a calibrated body. Its rated output in mV/V is the output change from zero to rated load with 1 V excitation, so a 2 mV/V cell at 5 V gives 10 mV at full load and the output scales in proportion to the load.
Limitations: the gauges and completion resistors are ideal and equal, lead resistance is zero, and the excitation is constant. Poisson-gauge arrangements, lead desensitisation, temperature effects, the load cell's own nonlinearity and hysteresis, and amplifier or ADC scaling are not included. The sign shown follows the stated arm layout, as Vishay and HBK print it; NI's equations use the opposite sign, and swapping the output leads reverses it.
Gauge factor: GF = (ΔR/R) / ε. ε in m/m; 1 με = 1e-6.
Quarter bridge: Vout / Vex = GF × ε / (4 + 2 × GF × ε).
Quarter-bridge inverse: ε = 4 × Vr / (GF × (1 - 2 × Vr)), Vr = Vout / Vex.
Half and full bridges: Vout / Vex = GF × ε / 2 (half); GF × ε (full).
Nonlinearity: η = GF × ε / (2 + GF × ε); exact = linear × (1 - η).
Load cell: Vout = V0 + C × Vex × F / Fcap. C in mV/V.
Quarter bridge, GF 2, +1000 με, 5 V: 2.4975 mV (0.4995 mV/V). Linear estimate 2.5 mV is 0.0999 % high.
Half and full bridges, same strain: 5 mV and 10 mV. Two and four active gauges with opposite strains; exactly linear.
Quarter bridge, GF 2, output 37.5 mV at 5 V: 15,228.4 με. Common mistake: the linear formula 4Vr/GF gives 15,000 με, 1.5 % low (Vishay TN-507's example).
Load cell 2 mV/V, 50 kg, 5 V, 20 kg: 4 mV of a 10 mV full scale. 2 × 5 × 20 / 50.
NI: Measuring strain with strain gages
NI-DAQmx: quarter-bridge type I
Vishay Micro-Measurements TN-507-1: Wheatstone bridge nonlinearity
HBK: The Wheatstone bridge circuit explained
Available now
Calculate electricity use from power and duration, or constant DC voltage and current. Compare energy use over different operating times in watt-hours, kilowatt-hours and joules.
Open tool →Available now
Add up to 20 resistors in series using Ω, kΩ or MΩ for circuit analysis and electricity calculations, with a diagram and running total.
Open tool →Available now
Convert absolute temperatures between Celsius, Fahrenheit and kelvin.
Open tool →Nice audio board working as expected.
Given the fact that this was my first purchase and I made it thinking I was buying genuine Yihua products, this has been a setback. I received a lesser known OEM brand called MYTO and while both the products seem to be similar from appearance, my real contention is the quality and quantity of the brass wool. On top of that not informing the customer about the unavailability of the Yihua product and instead sending a product from a different brand is also antagonising. Henceforth, I might just have to think twice before ordering from ThinkRobotics.
TOF MINIF Range Sensor - UART TOF Time-of-Flight Laser Range Sensor
We are disappointed with our recent order experience. We clearly communicated our requirement for 433 MHz antennas on WhatsApp, but the issue remains unresolved. We have been following up for more than 10 days and are still waiting for a proper refund resolution.
As a regular B2B customer, we expected better support. This experience has affected our trust in ThinkRobotics, and we may have to consider other suppliers for future purchases. We request a fair and prompt refund.
Anodised Aluminium Cup Head Washers (Pack of 10)