Electrical Energy Calculator
Calculate electricity use from power and duration, or constant DC voltage and current. Compare energy use over different operating times in watt-hours, kilowatt-hours and joules.
Open toolInteractive calculation is unavailable until JavaScript loads. The formulas, worked examples and references below remain available.
Convert between Thevenin and Norton equivalents, reduce a source with resistors to its equivalent, and find load current, voltage, power and maximum power transfer.
Choose how to describe the source: a Thevenin source, a Norton source, or a source with resistors.
Choose the resistance unit and enter the values. For a source with resistors, R_S is the source's own resistance, R1 is in series, R2 (optional) is across the output and R3 (optional) is in series with the output.
Read both equivalents and the maximum power the source can deliver.
Optionally enter a load resistance to see its current, voltage and power. The plot shows the source's terminal line and the load's operating point.
Copy result copies labeled values; Reset restores the starting fields.
Any linear resistive network with two terminals behaves, at those terminals, like a single voltage source in series with one resistor (Thevenin) or a single current source in parallel with one resistor (Norton). The Thevenin voltage is the open-circuit voltage; the Norton current is the short-circuit current; the resistance, the same in both, is what you measure between the terminals with every source switched off.
The two equivalents describe the same straight line of terminal voltage against current: it starts at the open-circuit voltage with no current and falls to zero voltage at the short-circuit current. Its slope is the resistance, so I_N = V_TH / R_TH.
A load receives the most power when its resistance equals the source resistance. The voltage and current are then half their maximum values and the load gets V_TH^2 / (4 R_TH). Half of the equivalent source's power is lost in R_TH at that point, so maximum power is not maximum efficiency: a larger load takes less power but wastes less.
Limitations: the equivalent represents only what happens at the two terminals. The power lost inside the equivalent resistance is not the power lost inside the real circuit, so the load share is not the original network's efficiency. The tool handles one source with up to four resistors in fixed positions, not general networks, AC impedances or dependent sources, and it assumes the source is linear; batteries and regulators are only approximately so.
Conversion: I_N = V_TH / R_TH; R_N = R_TH; V_TH = I_N × R_N. Voltages in V, currents in A, resistances in Ω.
Source with resistors: V_TH = V_S × R2 / (R_S + R1 + R2); R_TH = (R_S + R1) ∥ R2 + R3. Without R2: V_TH = V_S, R_TH = R_S + R1 + R3.
Load: I_L = V_TH / (R_TH + R_L); V_L = I_L × R_L; P_L = I_L^2 × R_L.
Maximum power: P_max = V_TH^2 / (4 × R_TH) at R_L = R_TH.
Load share: η = R_L / (R_TH + R_L), 50 % at maximum power.
Thevenin 12 V, 4 Ω: Norton 3 A with 4 Ω; P_max = 9 W at 4 Ω. 12 / 4 = 3 A; 12^2 / 16 = 9 W.
Same source, 8 Ω load: 1 A, 8 V, 8 W (88.89 % of P_max). 12 / (4 + 8) = 1 A; the load takes 66.67 % of the equivalent's power.
9 V, R_S 1 kΩ, R1 10 kΩ, R2 10 kΩ, R3 2.2 kΩ, load 3.3 kΩ: V_TH = 4.286 V, R_TH = 7.438 kΩ; load 1.317 V, 399.1 μA, 525.7 μW. 9 × 10/21 V and 11 ∥ 10 + 2.2 kΩ. The load gets 85.15 % of P_max = 617.3 μW.
Norton 14 A with 0.8 Ω (Kuphaldt): Thevenin 11.2 V, 0.8 Ω; 39.2 W into 0.8 Ω. 14 × 0.8 = 11.2 V; 11.2^2 / 3.2 = 39.2 W.
12 V divider, R1 = R2 = 10 kΩ, load 5 kΩ: V_TH = 6 V, R_TH = 5 kΩ; 3 V and 1.8 mW in the load. Common mistake: this is maximum power, but the real divider draws 10.8 mW from the 12 V source, so only 16.67 % reaches the load, not the 50 % of the equivalent.
Thevenin 5 V with R_TH = 0: No Norton equivalent. Boundary: an ideal voltage source has no finite short-circuit current. With a 100 Ω load it still gives 50 mA and 250 mW.
Fiore: DC Electrical Circuit Analysis, sections 6.4 to 6.6
Available now
Calculate electricity use from power and duration, or constant DC voltage and current. Compare energy use over different operating times in watt-hours, kilowatt-hours and joules.
Open tool →Available now
Add up to 20 resistors in series using Ω, kΩ or MΩ for circuit analysis and electricity calculations, with a diagram and running total.
Open tool →Available now
Convert absolute temperatures between Celsius, Fahrenheit and kelvin.
Open tool →Nice audio board working as expected.
Given the fact that this was my first purchase and I made it thinking I was buying genuine Yihua products, this has been a setback. I received a lesser known OEM brand called MYTO and while both the products seem to be similar from appearance, my real contention is the quality and quantity of the brass wool. On top of that not informing the customer about the unavailability of the Yihua product and instead sending a product from a different brand is also antagonising. Henceforth, I might just have to think twice before ordering from ThinkRobotics.
TOF MINIF Range Sensor - UART TOF Time-of-Flight Laser Range Sensor
We are disappointed with our recent order experience. We clearly communicated our requirement for 433 MHz antennas on WhatsApp, but the issue remains unresolved. We have been following up for more than 10 days and are still waiting for a proper refund resolution.
As a regular B2B customer, we expected better support. This experience has affected our trust in ThinkRobotics, and we may have to consider other suppliers for future purchases. We request a fair and prompt refund.
Anodised Aluminium Cup Head Washers (Pack of 10)