555 astable / monostable calculator

Leave it empty for a standard 555 (exactly 2/3 of V_CC); enter a value only if you drive the CONT pin.

Enter decimals or scientific notation, such as 4.7 or 4.7e3. Changing a unit reinterprets its number.

No valid result to draw.

Show the steps

Interactive calculation is unavailable until JavaScript loads. The formulas, worked examples and references below remain available.

Calculate 555 timer astable frequency, period and duty cycle, or monostable pulse width, from timing resistors and capacitor.

How to use

Choose Astable for a free-running oscillator or Monostable for a one-shot pulse.

Enter the timing resistors with their units: R_A and R_B for astable, or drag the R_B slider; R for monostable.

Enter the timing capacitor and choose its unit.

Leave the threshold empty for a standard 555 with CONT unconnected or decoupled; enter a percentage only if you drive the CONT pin.

Read the frequency, times and duty cycle, or the pulse width, and the waveform. Copy result copies the labeled values. Reset restores the starting example.

Science

Inside the 555, three equal resistors set two comparator references: 2/3 of the supply at the threshold input and 1/3 at the trigger input. The supply voltage cancels out of the timing, so the times depend only on the resistors, the capacitor and those ratios.

In astable mode the capacitor charges through R_A and R_B from 1/3 to 2/3 of the supply while the output is high, then discharges through R_B alone back to 1/3 while the output is low. Each half takes ln 2 ≈ 0.693 time constants, so the high time is always longer than the low time and the duty cycle stays above 50 %.

In monostable mode a trigger pulse sets the output high and releases the capacitor, which charges through R from 0 to 2/3 of the supply. That takes ln 3 ≈ 1.1 time constants, after which the output returns low and the capacitor is discharged.

Data sheets round the constants to 0.693, 1.44 and 1.1, which is why other calculators differ in the third digit; this tool uses the exact ln 2 and ln 3 and shows the rounded result beside it. Many designers keep R_A at 1 kΩ or more to limit the discharge-pin current.

Limitations: the tool assumes ideal thresholds and an ideal capacitor. The very first astable cycle after power-up is longer, because the capacitor starts from 0 V. Capacitor tolerance (often 10 % or 20 %), leakage in electrolytics and the 555's own timing error dominate real accuracy, and at high speed the 555's internal delays lengthen the times. Duty cycles below 50 % (diode-steered circuits) and solving for parts from a target frequency are not covered, and the tool suggests no standard values.

Formulas

Astable high time: t_H = ln 2 × (R_A + R_B) × C. Times in s, R in Ω, C in F.

Astable low time: t_L = ln 2 × R_B × C.

Frequency: f = 1 ÷ (t_H + t_L) = 1 ÷ (ln 2 × (R_A + 2 × R_B) × C) ≈ 1.44 ÷ ((R_A + 2 × R_B) × C).

Duty cycle: D = (R_A + R_B) ÷ (R_A + 2 × R_B) × 100 %.

Monostable pulse: t_W = ln 3 × R × C ≈ 1.1 × R × C.

Other thresholds: With upper threshold u and lower u ÷ 2 (fractions of V_CC): t_H = (R_A + R_B) C ln((1 − u ÷ 2) ÷ (1 − u)), t_L = R_B C ln 2, t_W = R C ln(1 ÷ (1 − u)).

Examples

Astable, R_A 1 kΩ, R_B 10 kΩ, C 10 μF: f = 6.87 Hz, duty cycle 52.38 %. t_H = 0.6931 × 11 kΩ × 10 μF = 76.25 ms; t_L = 69.31 ms. The rounded 1.44 constant gives 6.857 Hz.

Monostable, R 100 kΩ, C 10 μF: t_W = 1.099 s. 1.0986 × 100 kΩ × 10 μF. The data sheet's 1.1 R C gives 1.1 s.

Astable, R_A 1 kΩ, R_B 1 kΩ, C 1 μF, expecting 50 % duty: f = 480.9 Hz, duty cycle 66.67 %. Equal resistors do not give a square wave: the high time uses R_A + R_B and the low time only R_B. Make R_B much larger than R_A, or use a diode-steered circuit.

References

Texas Instruments: NE555 precision timer data sheet (SLFS022)

Texas Instruments: TLC555 LinCMOS timer data sheet