Electrical Energy Calculator
Calculate electricity use from power and duration, or constant DC voltage and current. Compare energy use over different operating times in watt-hours, kilowatt-hours and joules.
Open toolInteractive calculation is unavailable until JavaScript loads. The formulas, worked examples and references below remain available.
Solve DC power, voltage or current from the other two, and compare the current a constant-power load draws at common supply voltages.
Choose Solve for: power, current or voltage. The calculator starts with 12 V and 2 A, which gives 24 W.
Enter the other two values and choose their units. Use decimal or scientific notation, such as 0.5 or 5e-1. Drag the voltage slider to try supplies from 1 to 48 V.
Read the result. It uses a unit prefix that keeps the number between 1 and 999, such as 495 mW. Open Show the steps to see the substitution.
Read the bars and the table for the current the same power needs at 3.3, 5, 12, 24 and 48 V and at your voltage. They assume a constant-power load.
Copy result copies the inputs, result and assumption. Reset restores the starting values and choices.
Electrical power is the rate of energy transfer. For a DC load, power equals voltage multiplied by current. One watt is one volt times one ampere.
The same power needs more current at a lower voltage. A 60 W load draws 5 A from 12 V but 2.5 A from 24 V. Higher current needs thicker wire and larger connectors and fuses, which is one reason higher supply voltages are used for larger loads.
The comparison assumes a constant-power load, such as a device behind a voltage regulator or DC-DC converter, which draws the power it needs at any supply voltage within its rated input range. A resistive load, such as a heater, behaves differently: doubling its voltage doubles its current and quadruples its power. Use an Ohm's law calculator for resistive loads.
For AC, use RMS voltage and current. The product equals real power only for a resistive load with a power factor of 1. Motors and power supplies have a lower power factor, so volts times amps gives apparent power in volt-amperes, not watts.
Limitations: the calculator uses magnitudes and shows four significant digits. It does not model losses, wiring voltage drop, startup surges or a device's allowed input range. Check a device's rating before connecting it to a different supply voltage.
Power: P = V × I. P is power in watts, V is voltage in volts and I is current in amperes.
Current: I = P ÷ V, for V > 0.
Voltage: V = P ÷ I, for I > 0.
Constant-power comparison: I_k = P ÷ V_k for each supply voltage V_k.
Resistive contrast: For a resistor R = V² ÷ P, a new voltage V2 gives I2 = V2 ÷ R and P2 = V2² ÷ R.
12 V and 2 A: 24 W. Multiply voltage by current. The same 24 W needs 7.273 A from 3.3 V and 500 mA from 48 V.
60 W at 12 V: 5 A, or 2.5 A at 24 V. Divide power by voltage. A constant-power load needs half the current at twice the voltage.
60 W at 2.5 A: 24 V. Divide power by current.
3.3 V and 150 mA: 495 mW. Convert 150 mA to 0.15 A first: 3.3 × 0.15 = 0.495 W.
12 W, 12 V heater moved to 24 V: 2 A and 48 W, not 0.5 A. Common mistake: a heater is resistive (12 Ω), so it does not hold 12 W. The comparison applies only to constant-power loads.
Solve voltage with 0 A: No unique voltage. With zero current any voltage gives zero power; enter a nonzero current.
OpenStax University Physics Volume 2, 9.5: Electrical Energy and Power
OpenStax University Physics Volume 2, 15.4: Power in an AC Circuit
NIST Special Publication 811: Guide for the Use of the International System of Units
Available now
Calculate electricity use from power and duration, or constant DC voltage and current. Compare energy use over different operating times in watt-hours, kilowatt-hours and joules.
Open tool →Available now
Add up to 20 resistors in series using Ω, kΩ or MΩ for circuit analysis and electricity calculations, with a diagram and running total.
Open tool →Available now
Convert absolute temperatures between Celsius, Fahrenheit and kelvin.
Open tool →Nice audio board working as expected.
Given the fact that this was my first purchase and I made it thinking I was buying genuine Yihua products, this has been a setback. I received a lesser known OEM brand called MYTO and while both the products seem to be similar from appearance, my real contention is the quality and quantity of the brass wool. On top of that not informing the customer about the unavailability of the Yihua product and instead sending a product from a different brand is also antagonising. Henceforth, I might just have to think twice before ordering from ThinkRobotics.