TE CONNECTIVITY/AMP BRAND Circuit Breakers W92-X112-2 M6/M7/M9/W6/W7
Ensure reliable circuit protection with the TE Connectivity (TE) AMP Series W92-X112-2 magnetic hydraulic circuit breakers. Designed for industrial applications, these circuit breakers are recognized for their high performance, safety, and compliance with international standards.
Product Features
Rated current up to 50 Amps, suitable for various industrial applications
Available in multiple configurations with different trip curve options
Heavy-duty #10-32 stud connections (W9 model)
Quick-connect or screw terminal options (W6 model)
Trip-free operation for enhanced safety
UL Recognized (UL1077), CSA accepted, and VDE approved
Designed for international markets with compliance to multiple standards
Electrical and Mechanical Specifications
Characteristic
Specification
Calibration
Holds 100% rated current; trips between 101% and 124% of rated load (134% for AC/DC units); trips at 125% and above (135% for AC/DC units)
Dielectric Strength
1500V at 50/60Hz (DC: 1100V)
Insulation Resistance
100 Megaohms at 500VDC
Endurance
10,000 on/off cycles (6000 at rated load, 4000 at no load)
Operating Temperature
-40°C to +85°C
Humidity
Meets Mil-STD-202 method 103
Shock
Tested per Mil-STD-202, method 213, test condition C (100g @ 6 ms)
Vibration
Tested per Mil-STD-202, method 201, 10-55 Hz, 0.06” total excursion
Mounting
Two #6-32 screws from the front; optional metric models available; recommended torque: 6-8 in-lb
Weight
Approximately 2.5 ounces per pole
Approvals & Ratings
Model
Maximum Voltage
Frequency
Phase
Current Rating (Amps)
Interrupting Capacity (Amps)
W6 Series
65V DC, 277V AC, 277/480V
DC, 50/60Hz
-
0.2 - 50
2,000 - 5,000
W9 Series
65V DC, 277V AC, 277/480V
DC, 50/60Hz
-
0.2 - 50
2,000 - 5,000
Trip Curves & Performance
Includes multiple trip curve options such as instant, standard delay, short delay, and high inrush curves. Detailed trip times and overload characteristics are available in the datasheet.
Physical Dimensions & Mounting
Outline dimensions and mounting details are provided for toggle actuator models, with panel mounting cutouts and terminal configurations specified for various pole counts. Dimensions are in inches and millimeters.
Note: Please review the datasheet thoroughly before selecting this product to ensure it meets your application requirements. For more detailed specifications, visit the provided datasheet link.
Use left/right arrows to navigate the slideshow or swipe left/right if using a mobile device
Choosing a selection results in a full page refresh.
Press the space key then arrow keys to make a selection.
Shopping Cart
{"id":10002283659581,"title":"7-1393254-1","handle":"7-1393254-1","description":"\u003ch3\u003eTE CONNECTIVITY\/AMP BRAND Circuit Breakers W92-X112-2 M6\/M7\/M9\/W6\/W7\u003c\/h3\u003e\n\n\u003cp\u003eEnsure reliable circuit protection with the TE Connectivity (TE) AMP Series W92-X112-2 magnetic hydraulic circuit breakers. Designed for industrial applications, these circuit breakers are recognized for their high performance, safety, and compliance with international standards.\u003c\/p\u003e\n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eRated current up to 50 Amps, suitable for various industrial applications\u003c\/li\u003e\n \u003cli\u003eAvailable in multiple configurations with different trip curve options\u003c\/li\u003e\n \u003cli\u003eHeavy-duty #10-32 stud connections (W9 model)\u003c\/li\u003e\n \u003cli\u003eQuick-connect or screw terminal options (W6 model)\u003c\/li\u003e\n \u003cli\u003eTrip-free operation for enhanced safety\u003c\/li\u003e\n \u003cli\u003eUL Recognized (UL1077), CSA accepted, and VDE approved\u003c\/li\u003e\n \u003cli\u003eDesigned for international markets with compliance to multiple standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eElectrical and Mechanical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n \u003cth\u003eCharacteristic\u003c\/th\u003e\n \u003cth\u003eSpecification\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eCalibration\u003c\/td\u003e\n \u003ctd\u003eHolds 100% rated current; trips between 101% and 124% of rated load (134% for AC\/DC units); trips at 125% and above (135% for AC\/DC units)\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eDielectric Strength\u003c\/td\u003e\n \u003ctd\u003e1500V at 50\/60Hz (DC: 1100V)\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n \u003ctd\u003e100 Megaohms at 500VDC\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eEndurance\u003c\/td\u003e\n \u003ctd\u003e10,000 on\/off cycles (6000 at rated load, 4000 at no load)\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n \u003ctd\u003e-40°C to +85°C\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eHumidity\u003c\/td\u003e\n \u003ctd\u003eMeets Mil-STD-202 method 103\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eShock\u003c\/td\u003e\n \u003ctd\u003eTested per Mil-STD-202, method 213, test condition C (100g @ 6 ms)\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eVibration\u003c\/td\u003e\n \u003ctd\u003eTested per Mil-STD-202, method 201, 10-55 Hz, 0.06” total excursion\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eMounting\u003c\/td\u003e\n \u003ctd\u003eTwo #6-32 screws from the front; optional metric models available; recommended torque: 6-8 in-lb\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eWeight\u003c\/td\u003e\n \u003ctd\u003eApproximately 2.5 ounces per pole\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApprovals \u0026amp; Ratings\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n \u003cth\u003eModel\u003c\/th\u003e\n \u003cth\u003eMaximum Voltage\u003c\/th\u003e\n \u003cth\u003eFrequency\u003c\/th\u003e\n \u003cth\u003ePhase\u003c\/th\u003e\n \u003cth\u003eCurrent Rating (Amps)\u003c\/th\u003e\n \u003cth\u003eInterrupting Capacity (Amps)\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eW6 Series\u003c\/td\u003e\n \u003ctd\u003e65V DC, 277V AC, 277\/480V\u003c\/td\u003e\n \u003ctd\u003eDC, 50\/60Hz\u003c\/td\u003e\n \u003ctd\u003e-\u003c\/td\u003e\n \u003ctd\u003e0.2 - 50\u003c\/td\u003e\n \u003ctd\u003e2,000 - 5,000\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eW9 Series\u003c\/td\u003e\n \u003ctd\u003e65V DC, 277V AC, 277\/480V\u003c\/td\u003e\n \u003ctd\u003eDC, 50\/60Hz\u003c\/td\u003e\n \u003ctd\u003e-\u003c\/td\u003e\n \u003ctd\u003e0.2 - 50\u003c\/td\u003e\n \u003ctd\u003e2,000 - 5,000\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTrip Curves \u0026amp; Performance\u003c\/h3\u003e\n\u003cp\u003eIncludes multiple trip curve options such as instant, standard delay, short delay, and high inrush curves. Detailed trip times and overload characteristics are available in the datasheet.\u003c\/p\u003e\n\n\u003ch3\u003ePhysical Dimensions \u0026amp; Mounting\u003c\/h3\u003e\n\u003cp\u003eOutline dimensions and mounting details are provided for toggle actuator models, with panel mounting cutouts and terminal configurations specified for various pole counts. Dimensions are in inches and millimeters.\u003c\/p\u003e\n\n\u003ch3\u003eDatasheet\u003c\/h3\u003e\n\u003cp\u003eFor detailed technical data, please refer to the \u003ca href=\"https:\/\/www.te.com\/commerce\/DocumentDelivery\/DDEController?Action=srchrtrv\u0026amp;DocNm=1308242_w6w9\u0026amp;DocType=Data+Sheet\u0026amp;DocLang=English\u0026amp;PartCntxt=7-1393254-1\u0026amp;DocFormat=pdf\" target=\"_blank\"\u003eTE Connectivity W6\/W9 Series Datasheet\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eAdditional Information\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003ePackage Type: Tray\u003c\/li\u003e\n \u003cli\u003eCountry of Origin: MX\u003c\/li\u003e\n \u003cli\u003eRoHS Compliant: Yes\u003c\/li\u003e\n \u003cli\u003eECCN: EAR99\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eNote: Please review the datasheet thoroughly before selecting this product to ensure it meets your application requirements. For more detailed specifications, visit the provided datasheet link.\u003c\/p\u003e","published_at":"2025-08-03T04:07:32+05:30","created_at":"2025-08-03T04:07:32+05:30","vendor":"Waldom Electonics","type":"Circuit Protection","tags":["Circuit","TE-AMP","WLDM"],"price":3200500,"price_min":3200500,"price_max":3200500,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50546644779325,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"7-1393254-1","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"7-1393254-1","public_title":null,"options":["Default Title"],"price":3200500,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"7-1393254-1","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/10473373.jpg?v=1754174252"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/10473373.jpg?v=1754174252","options":["Title"],"media":[{"alt":null,"id":45641800089917,"position":1,"preview_image":{"aspect_ratio":1.754,"height":114,"width":200,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/10473373.jpg?v=1754174252"},"aspect_ratio":1.754,"height":114,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/10473373.jpg?v=1754174252","width":200}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eTE CONNECTIVITY\/AMP BRAND Circuit Breakers W92-X112-2 M6\/M7\/M9\/W6\/W7\u003c\/h3\u003e\n\n\u003cp\u003eEnsure reliable circuit protection with the TE Connectivity (TE) AMP Series W92-X112-2 magnetic hydraulic circuit breakers. Designed for industrial applications, these circuit breakers are recognized for their high performance, safety, and compliance with international standards.\u003c\/p\u003e\n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eRated current up to 50 Amps, suitable for various industrial applications\u003c\/li\u003e\n \u003cli\u003eAvailable in multiple configurations with different trip curve options\u003c\/li\u003e\n \u003cli\u003eHeavy-duty #10-32 stud connections (W9 model)\u003c\/li\u003e\n \u003cli\u003eQuick-connect or screw terminal options (W6 model)\u003c\/li\u003e\n \u003cli\u003eTrip-free operation for enhanced safety\u003c\/li\u003e\n \u003cli\u003eUL Recognized (UL1077), CSA accepted, and VDE approved\u003c\/li\u003e\n \u003cli\u003eDesigned for international markets with compliance to multiple standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eElectrical and Mechanical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n \u003cth\u003eCharacteristic\u003c\/th\u003e\n \u003cth\u003eSpecification\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eCalibration\u003c\/td\u003e\n \u003ctd\u003eHolds 100% rated current; trips between 101% and 124% of rated load (134% for AC\/DC units); trips at 125% and above (135% for AC\/DC units)\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eDielectric Strength\u003c\/td\u003e\n \u003ctd\u003e1500V at 50\/60Hz (DC: 1100V)\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n \u003ctd\u003e100 Megaohms at 500VDC\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eEndurance\u003c\/td\u003e\n \u003ctd\u003e10,000 on\/off cycles (6000 at rated load, 4000 at no load)\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n \u003ctd\u003e-40°C to +85°C\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eHumidity\u003c\/td\u003e\n \u003ctd\u003eMeets Mil-STD-202 method 103\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eShock\u003c\/td\u003e\n \u003ctd\u003eTested per Mil-STD-202, method 213, test condition C (100g @ 6 ms)\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eVibration\u003c\/td\u003e\n \u003ctd\u003eTested per Mil-STD-202, method 201, 10-55 Hz, 0.06” total excursion\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eMounting\u003c\/td\u003e\n \u003ctd\u003eTwo #6-32 screws from the front; optional metric models available; recommended torque: 6-8 in-lb\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eWeight\u003c\/td\u003e\n \u003ctd\u003eApproximately 2.5 ounces per pole\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApprovals \u0026amp; Ratings\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n \u003cth\u003eModel\u003c\/th\u003e\n \u003cth\u003eMaximum Voltage\u003c\/th\u003e\n \u003cth\u003eFrequency\u003c\/th\u003e\n \u003cth\u003ePhase\u003c\/th\u003e\n \u003cth\u003eCurrent Rating (Amps)\u003c\/th\u003e\n \u003cth\u003eInterrupting Capacity (Amps)\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eW6 Series\u003c\/td\u003e\n \u003ctd\u003e65V DC, 277V AC, 277\/480V\u003c\/td\u003e\n \u003ctd\u003eDC, 50\/60Hz\u003c\/td\u003e\n \u003ctd\u003e-\u003c\/td\u003e\n \u003ctd\u003e0.2 - 50\u003c\/td\u003e\n \u003ctd\u003e2,000 - 5,000\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eW9 Series\u003c\/td\u003e\n \u003ctd\u003e65V DC, 277V AC, 277\/480V\u003c\/td\u003e\n \u003ctd\u003eDC, 50\/60Hz\u003c\/td\u003e\n \u003ctd\u003e-\u003c\/td\u003e\n \u003ctd\u003e0.2 - 50\u003c\/td\u003e\n \u003ctd\u003e2,000 - 5,000\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTrip Curves \u0026amp; Performance\u003c\/h3\u003e\n\u003cp\u003eIncludes multiple trip curve options such as instant, standard delay, short delay, and high inrush curves. Detailed trip times and overload characteristics are available in the datasheet.\u003c\/p\u003e\n\n\u003ch3\u003ePhysical Dimensions \u0026amp; Mounting\u003c\/h3\u003e\n\u003cp\u003eOutline dimensions and mounting details are provided for toggle actuator models, with panel mounting cutouts and terminal configurations specified for various pole counts. Dimensions are in inches and millimeters.\u003c\/p\u003e\n\n\u003ch3\u003eDatasheet\u003c\/h3\u003e\n\u003cp\u003eFor detailed technical data, please refer to the \u003ca href=\"https:\/\/www.te.com\/commerce\/DocumentDelivery\/DDEController?Action=srchrtrv\u0026amp;DocNm=1308242_w6w9\u0026amp;DocType=Data+Sheet\u0026amp;DocLang=English\u0026amp;PartCntxt=7-1393254-1\u0026amp;DocFormat=pdf\" target=\"_blank\"\u003eTE Connectivity W6\/W9 Series Datasheet\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eAdditional Information\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003ePackage Type: Tray\u003c\/li\u003e\n \u003cli\u003eCountry of Origin: MX\u003c\/li\u003e\n \u003cli\u003eRoHS Compliant: Yes\u003c\/li\u003e\n \u003cli\u003eECCN: EAR99\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eNote: Please review the datasheet thoroughly before selecting this product to ensure it meets your application requirements. For more detailed specifications, visit the provided datasheet link.\u003c\/p\u003e"}