ADVANCED ENERGY / SL POWER / CONDOR GLC50-15G Switching Power Supply - 50W, 15V @ 3.3A
The GLC50-15G is a high-performance AC-DC switching power supply designed for reliable power conversion in various applications. Manufactured by ADVANCED ENERGY / SL POWER / CONDOR, this power supply offers a compact form factor and robust features suitable for commercial and medical environments.
Compact dimensions: 4.25” x 2.50” x 1.25” (meets 1U application requirements)
Built-in overload and overvoltage protection
EMI compliance exceeding FCC Class B and CISPR 22 Class B standards
Medical and commercial safety certifications including UL, CSA, IEC 60950-1, EN 60950, and IEC 60601-1 (medical models)
RoHS compliant models available (G suffix)
Marked to LVD standards
Performance Specifications:
Parameter
Typical Value
Temperature Coefficient
0.03%/°C
Output Noise
0.5% rms, 1% pk-pk, 20 MHz bandwidth
Transient Response
500 μs typical for 50% load step change
Voltage Adjustment
Built-in potentiometer, ±5%
Leakage Current (Commercial)
160 μA at 254 Vac, 60 Hz
Leakage Current (Medical)
100 μA at 264 Vac, 60 Hz
EMI/EMC Compliance:
EN55022 Class B; FCC Class B
EN55011 Class B; FCC Class B
EN61000-4-2, 6 kV contact; 8 kV air
EN61000-4-3, 3 V/meter
EN61000-4-4, 2 kV, 5 kHz
EN61000-4-5, 1 kV differential; 2 kV common
Mechanical and Environmental Specifications:
Parameter
Operating Conditions
Temperature Range
0 to 50°C; -40 to +85°C (derate output by 2.5% per °C above 50°C)
Humidity
0 to 95% RH
Shock
20 g pk
Vibration
1.5 g rms
Altitude
-500 to 10,000 ft
For more detailed specifications and safety information, please refer to the full datasheet.
Note: All specifications are typical at nominal input, full load, and 25°C unless otherwise specified. Add “G” suffix to model number for RoHS compliant versions.
Disclaimers: All specifications are subject to change without notice. Please consult the datasheet for the most current information.
Use left/right arrows to navigate the slideshow or swipe left/right if using a mobile device
Choosing a selection results in a full page refresh.
Press the space key then arrow keys to make a selection.
Shopping Cart
{"id":10013833953597,"title":"GLC50-15G","handle":"glc50-15g","description":"\u003ch3\u003eADVANCED ENERGY \/ SL POWER \/ CONDOR GLC50-15G Switching Power Supply - 50W, 15V @ 3.3A\u003c\/h3\u003e\n\u003cp\u003eThe GLC50-15G is a high-performance AC-DC switching power supply designed for reliable power conversion in various applications. Manufactured by ADVANCED ENERGY \/ SL POWER \/ CONDOR, this power supply offers a compact form factor and robust features suitable for commercial and medical environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Details:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e GLC50-15G\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ADVANCED ENERGY \/ SL POWER \/ CONDOR\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e MX\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit of Measure:\u003c\/strong\u003e EA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e EAR99\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Type:\u003c\/strong\u003e Not specified\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDatasheet:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.waldomapac.com\/productfiles\/mf-cod\/20070205102150181487641_glx50g.pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e50W power output with 15V at 3.3A\u003c\/li\u003e\n\u003cli\u003eUniversal input voltage range of 90-264 Vac\u003c\/li\u003e\n\u003cli\u003eCompact dimensions: 4.25” x 2.50” x 1.25” (meets 1U application requirements)\u003c\/li\u003e\n\u003cli\u003eBuilt-in overload and overvoltage protection\u003c\/li\u003e\n\u003cli\u003eEMI compliance exceeding FCC Class B and CISPR 22 Class B standards\u003c\/li\u003e\n\u003cli\u003eMedical and commercial safety certifications including UL, CSA, IEC 60950-1, EN 60950, and IEC 60601-1 (medical models)\u003c\/li\u003e\n\u003cli\u003eRoHS compliant models available (G suffix)\u003c\/li\u003e\n\u003cli\u003eMarked to LVD standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eTypical Value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Coefficient\u003c\/td\u003e\n\u003ctd\u003e0.03%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Noise\u003c\/td\u003e\n\u003ctd\u003e0.5% rms, 1% pk-pk, 20 MHz bandwidth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransient Response\u003c\/td\u003e\n\u003ctd\u003e500 μs typical for 50% load step change\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Adjustment\u003c\/td\u003e\n\u003ctd\u003eBuilt-in potentiometer, ±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeakage Current (Commercial)\u003c\/td\u003e\n\u003ctd\u003e160 μA at 254 Vac, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeakage Current (Medical)\u003c\/td\u003e\n\u003ctd\u003e100 μA at 264 Vac, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eEMI\/EMC Compliance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEN55022 Class B; FCC Class B\u003c\/li\u003e\n\u003cli\u003eEN55011 Class B; FCC Class B\u003c\/li\u003e\n\u003cli\u003eEN61000-4-2, 6 kV contact; 8 kV air\u003c\/li\u003e\n\u003cli\u003eEN61000-4-3, 3 V\/meter\u003c\/li\u003e\n\u003cli\u003eEN61000-4-4, 2 kV, 5 kHz\u003c\/li\u003e\n\u003cli\u003eEN61000-4-5, 1 kV differential; 2 kV common\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical and Environmental Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eOperating Conditions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C; -40 to +85°C (derate output by 2.5% per °C above 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e0 to 95% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd\u003e20 g pk\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003e1.5 g rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e-500 to 10,000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eFor more detailed specifications and safety information, please refer to the \u003ca href=\"https:\/\/www.waldomapac.com\/productfiles\/mf-cod\/20070205102150181487641_glx50g.pdf\" target=\"_blank\"\u003efull datasheet\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e All specifications are typical at nominal input, full load, and 25°C unless otherwise specified. Add “G” suffix to model number for RoHS compliant versions.\u003c\/p\u003e\n\u003cp\u003eDisclaimers: All specifications are subject to change without notice. Please consult the datasheet for the most current information.\u003c\/p\u003e","published_at":"2025-08-10T22:54:02+05:30","created_at":"2025-08-10T22:54:02+05:30","vendor":"Waldom Electonics","type":"AC-DC Power Supply","tags":["15V","3A","50W","ADVAN-SLPO","IMPORT_CSV","Power","Switch","Switching","WLDM"],"price":438086,"price_min":438086,"price_max":438086,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50579073696061,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"GLC50-15G","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"GLC50-15G","public_title":null,"options":["Default Title"],"price":438086,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"GLC50-15G","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/GLC50-15G_11158731_23a833ac.jpg?v=1754846646"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/GLC50-15G_11158731_23a833ac.jpg?v=1754846646","options":["Title"],"media":[{"alt":null,"id":45766435897661,"position":1,"preview_image":{"aspect_ratio":1.0,"height":200,"width":200,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/GLC50-15G_11158731_23a833ac.jpg?v=1754846646"},"aspect_ratio":1.0,"height":200,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/GLC50-15G_11158731_23a833ac.jpg?v=1754846646","width":200}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eADVANCED ENERGY \/ SL POWER \/ CONDOR GLC50-15G Switching Power Supply - 50W, 15V @ 3.3A\u003c\/h3\u003e\n\u003cp\u003eThe GLC50-15G is a high-performance AC-DC switching power supply designed for reliable power conversion in various applications. Manufactured by ADVANCED ENERGY \/ SL POWER \/ CONDOR, this power supply offers a compact form factor and robust features suitable for commercial and medical environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Details:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e GLC50-15G\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ADVANCED ENERGY \/ SL POWER \/ CONDOR\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e MX\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit of Measure:\u003c\/strong\u003e EA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e EAR99\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Type:\u003c\/strong\u003e Not specified\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDatasheet:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.waldomapac.com\/productfiles\/mf-cod\/20070205102150181487641_glx50g.pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e50W power output with 15V at 3.3A\u003c\/li\u003e\n\u003cli\u003eUniversal input voltage range of 90-264 Vac\u003c\/li\u003e\n\u003cli\u003eCompact dimensions: 4.25” x 2.50” x 1.25” (meets 1U application requirements)\u003c\/li\u003e\n\u003cli\u003eBuilt-in overload and overvoltage protection\u003c\/li\u003e\n\u003cli\u003eEMI compliance exceeding FCC Class B and CISPR 22 Class B standards\u003c\/li\u003e\n\u003cli\u003eMedical and commercial safety certifications including UL, CSA, IEC 60950-1, EN 60950, and IEC 60601-1 (medical models)\u003c\/li\u003e\n\u003cli\u003eRoHS compliant models available (G suffix)\u003c\/li\u003e\n\u003cli\u003eMarked to LVD standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eTypical Value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Coefficient\u003c\/td\u003e\n\u003ctd\u003e0.03%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Noise\u003c\/td\u003e\n\u003ctd\u003e0.5% rms, 1% pk-pk, 20 MHz bandwidth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransient Response\u003c\/td\u003e\n\u003ctd\u003e500 μs typical for 50% load step change\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Adjustment\u003c\/td\u003e\n\u003ctd\u003eBuilt-in potentiometer, ±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeakage Current (Commercial)\u003c\/td\u003e\n\u003ctd\u003e160 μA at 254 Vac, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeakage Current (Medical)\u003c\/td\u003e\n\u003ctd\u003e100 μA at 264 Vac, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eEMI\/EMC Compliance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEN55022 Class B; FCC Class B\u003c\/li\u003e\n\u003cli\u003eEN55011 Class B; FCC Class B\u003c\/li\u003e\n\u003cli\u003eEN61000-4-2, 6 kV contact; 8 kV air\u003c\/li\u003e\n\u003cli\u003eEN61000-4-3, 3 V\/meter\u003c\/li\u003e\n\u003cli\u003eEN61000-4-4, 2 kV, 5 kHz\u003c\/li\u003e\n\u003cli\u003eEN61000-4-5, 1 kV differential; 2 kV common\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical and Environmental Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eOperating Conditions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C; -40 to +85°C (derate output by 2.5% per °C above 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e0 to 95% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd\u003e20 g pk\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003e1.5 g rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e-500 to 10,000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eFor more detailed specifications and safety information, please refer to the \u003ca href=\"https:\/\/www.waldomapac.com\/productfiles\/mf-cod\/20070205102150181487641_glx50g.pdf\" target=\"_blank\"\u003efull datasheet\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e All specifications are typical at nominal input, full load, and 25°C unless otherwise specified. Add “G” suffix to model number for RoHS compliant versions.\u003c\/p\u003e\n\u003cp\u003eDisclaimers: All specifications are subject to change without notice. Please consult the datasheet for the most current information.\u003c\/p\u003e"}