ADVANCED ENERGY / SL POWER / CONDOR AC-DC Regulated Power Supply Module 400W
Introducing the MINT1400A2810L01 from ADVANCED ENERGY / SL POWER / CONDOR, a high-performance AC-DC switching power supply designed for medical and industrial applications. This regulated power supply offers reliable power conversion with advanced safety and efficiency features.
Product Highlights:
Power Output: 400W with peak capacity of 450W for 1 minute at 10% duty cycle
Note: For detailed specifications and application guidelines, please refer to the datasheet linked above. This power supply is safety approved for medical and industrial standards, ensuring reliable performance in critical systems.
Disclaimers: All specifications are typical at nominal input, full load, and 25°C unless otherwise stated. Please consult the datasheet for comprehensive details.
{"id":10013622731069,"title":"MINT1400A2810L01","handle":"mint1400a2810l01","description":"\u003ch3\u003eADVANCED ENERGY \/ SL POWER \/ CONDOR AC-DC Regulated Power Supply Module 400W\u003c\/h3\u003e\n\u003cp\u003eIntroducing the \u003cstrong\u003eMINT1400A2810L01\u003c\/strong\u003e from \u003cstrong\u003eADVANCED ENERGY \/ SL POWER \/ CONDOR\u003c\/strong\u003e, a high-performance AC-DC switching power supply designed for medical and industrial applications. This regulated power supply offers reliable power conversion with advanced safety and efficiency features.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Highlights:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower Output: 400W with peak capacity of 450W for 1 minute at 10% duty cycle\u003c\/li\u003e\n\u003cli\u003eInput Voltage: Universal 85-270VAC, 47-63Hz single-phase\u003c\/li\u003e\n\u003cli\u003eOutput Voltage: 28V DC with adjustable regulation +\/- 5%\u003c\/li\u003e\n\u003cli\u003eMaximum Output Current: 14.3A\u003c\/li\u003e\n\u003cli\u003eEfficiency: Up to 91% at 240VAC, typical 88% at 120VAC\u003c\/li\u003e\n\u003cli\u003eCompact Size: 3.94” x 7” x 1.58”, 1U compatible, 9.5 W\/in³\u003c\/li\u003e\n\u003cli\u003eCooling: Fan cooling with derating for higher temperatures\u003c\/li\u003e\n\u003cli\u003eSafety Compliance: EN\/IEC\/UL 60601-1, CSA 601.1, EN55011\/22 Class B conducted noise\u003c\/li\u003e\n\u003cli\u003eIsolation: Input-Output 4000VAC, Input-Ground 1500VAC, Output-Ground 500VAC\u003c\/li\u003e\n\u003cli\u003eRemote ON\/OFF, PFC, and Power Good signals for system integration\u003c\/li\u003e\n\u003cli\u003eRoHS Compliant – Category 6\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Input\u003c\/td\u003e\n\u003ctd\u003e85-270VAC, 47-63Hz, single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e120VAC: 4.2A, 230VAC: 2.1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e37A max (active circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor\u003c\/td\u003e\n\u003ctd\u003e0.99 typical, 0.96 minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eTypical 88% @ 120VAC, 91% @ 240VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power\u003c\/td\u003e\n\u003ctd\u003e400W (Peak 450W for 1 min.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRipple \u0026amp; Noise\u003c\/td\u003e\n\u003ctd\u003e1% pk-pk max., 20MHz BW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eInput-Output: 4000VAC, Input-Ground: 1500VAC, Output-Ground: 500VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 70°C (derate above 40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransient Response\u003c\/td\u003e\n\u003ctd\u003e500µs to 1%, 0.2A\/µs, 3.5% deviation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.94” x 7” x 1.58”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Details:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePart Number: \u003cstrong\u003eMINT1400A2810L01\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eManufacturer: \u003cstrong\u003eADVANCED ENERGY \/ SL POWER \/ CONDOR\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eCountry of Origin: \u003cstrong\u003eCN\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eUOM: \u003cstrong\u003eEA\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eECCN: \u003cstrong\u003eEAR99\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePackage Type: \u003cstrong\u003eStandard\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eDatasheet: \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-cod\/cod-mint1400a2810l01.pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e For detailed specifications and application guidelines, please refer to the datasheet linked above. This power supply is safety approved for medical and industrial standards, ensuring reliable performance in critical systems.\u003c\/p\u003e\n\u003cp\u003eDisclaimers: All specifications are typical at nominal input, full load, and 25°C unless otherwise stated. Please consult the datasheet for comprehensive details.\u003c\/p\u003e","published_at":"2025-08-10T19:42:31+05:30","created_at":"2025-08-10T19:42:32+05:30","vendor":"Waldom Electonics","type":"AC-DC Power Supply","tags":["400W","AC","ADVAN-SLPO","IMPORT_CSV","Power","Switching","WLDM"],"price":2100901,"price_min":2100901,"price_max":2100901,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50578738479421,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"MINT1400A2810L01","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"MINT1400A2810L01","public_title":null,"options":["Default Title"],"price":2100901,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"MINT1400A2810L01","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/MINT1400A2810L01_43060308_f12489f4.jpg?v=1754835156"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/MINT1400A2810L01_43060308_f12489f4.jpg?v=1754835156","options":["Title"],"media":[{"alt":null,"id":45764612489533,"position":1,"preview_image":{"aspect_ratio":1.375,"height":200,"width":275,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/MINT1400A2810L01_43060308_f12489f4.jpg?v=1754835156"},"aspect_ratio":1.375,"height":200,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/MINT1400A2810L01_43060308_f12489f4.jpg?v=1754835156","width":275}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eADVANCED ENERGY \/ SL POWER \/ CONDOR AC-DC Regulated Power Supply Module 400W\u003c\/h3\u003e\n\u003cp\u003eIntroducing the \u003cstrong\u003eMINT1400A2810L01\u003c\/strong\u003e from \u003cstrong\u003eADVANCED ENERGY \/ SL POWER \/ CONDOR\u003c\/strong\u003e, a high-performance AC-DC switching power supply designed for medical and industrial applications. This regulated power supply offers reliable power conversion with advanced safety and efficiency features.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Highlights:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower Output: 400W with peak capacity of 450W for 1 minute at 10% duty cycle\u003c\/li\u003e\n\u003cli\u003eInput Voltage: Universal 85-270VAC, 47-63Hz single-phase\u003c\/li\u003e\n\u003cli\u003eOutput Voltage: 28V DC with adjustable regulation +\/- 5%\u003c\/li\u003e\n\u003cli\u003eMaximum Output Current: 14.3A\u003c\/li\u003e\n\u003cli\u003eEfficiency: Up to 91% at 240VAC, typical 88% at 120VAC\u003c\/li\u003e\n\u003cli\u003eCompact Size: 3.94” x 7” x 1.58”, 1U compatible, 9.5 W\/in³\u003c\/li\u003e\n\u003cli\u003eCooling: Fan cooling with derating for higher temperatures\u003c\/li\u003e\n\u003cli\u003eSafety Compliance: EN\/IEC\/UL 60601-1, CSA 601.1, EN55011\/22 Class B conducted noise\u003c\/li\u003e\n\u003cli\u003eIsolation: Input-Output 4000VAC, Input-Ground 1500VAC, Output-Ground 500VAC\u003c\/li\u003e\n\u003cli\u003eRemote ON\/OFF, PFC, and Power Good signals for system integration\u003c\/li\u003e\n\u003cli\u003eRoHS Compliant – Category 6\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Input\u003c\/td\u003e\n\u003ctd\u003e85-270VAC, 47-63Hz, single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e120VAC: 4.2A, 230VAC: 2.1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e37A max (active circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor\u003c\/td\u003e\n\u003ctd\u003e0.99 typical, 0.96 minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eTypical 88% @ 120VAC, 91% @ 240VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power\u003c\/td\u003e\n\u003ctd\u003e400W (Peak 450W for 1 min.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRipple \u0026amp; Noise\u003c\/td\u003e\n\u003ctd\u003e1% pk-pk max., 20MHz BW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eInput-Output: 4000VAC, Input-Ground: 1500VAC, Output-Ground: 500VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 70°C (derate above 40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransient Response\u003c\/td\u003e\n\u003ctd\u003e500µs to 1%, 0.2A\/µs, 3.5% deviation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.94” x 7” x 1.58”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Details:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePart Number: \u003cstrong\u003eMINT1400A2810L01\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eManufacturer: \u003cstrong\u003eADVANCED ENERGY \/ SL POWER \/ CONDOR\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eCountry of Origin: \u003cstrong\u003eCN\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eUOM: \u003cstrong\u003eEA\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eECCN: \u003cstrong\u003eEAR99\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePackage Type: \u003cstrong\u003eStandard\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eDatasheet: \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-cod\/cod-mint1400a2810l01.pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e For detailed specifications and application guidelines, please refer to the datasheet linked above. This power supply is safety approved for medical and industrial standards, ensuring reliable performance in critical systems.\u003c\/p\u003e\n\u003cp\u003eDisclaimers: All specifications are typical at nominal input, full load, and 25°C unless otherwise stated. Please consult the datasheet for comprehensive details.\u003c\/p\u003e"}