ADVANCED ENERGY / SL POWER / CONDOR SLE65S1203N01 AC/DC Desktop Adapter 12V 65W
Ensure reliable power delivery with the SLE65S1203N01 AC/DC desktop power supply from ADVANCED ENERGY / SL POWER / CONDOR. Designed for industrial and medical applications, this high-efficiency power adapter provides a stable 12V output with a maximum power of 65W, meeting rigorous safety and performance standards.
Product Features
Single output 12V, 5.4A power supply with 65W rated power
Medical and industrial grade, compliant with IEC60601-1, IEC62638-1, UL62638-1 safety standards
Input voltage range: 90VAC–264VAC, 47Hz–63Hz
High efficiency: 89.0% average
Fast start-up time: ≤3 seconds
Overload, overvoltage, and short circuit protection with auto-recovery
Compact design: 125.0mm x 62.0mm x 34.0mm, weighing approximately 340 grams
Operating temperature: 0°C to 40°C; Storage temperature: -20°C to 60°C
RoHS compliant, ECCN: EAR99
Package Type: BOX
Technical Specifications
Model Number
Voltage
Current
Rated Power
Ripple & Noise
Voltage Tolerance
Line & Load Regulation
Efficiency (Average)
Start Up Delay
SLE65S1203N01
12.0V
5.4A
65.04W
200mV pk-pk
±5%
Line: ±1%, Load: ±5%
89.0%
≤3s
Input & Safety Standards
Input Voltage & Frequency
90VAC–264VAC, 47Hz–63Hz
Input Current
2.0A at 90VAC
Inrush Current
120A max at 240VAC cold start
Touch Leakage Current
≤100μA at 264VAC
Safety Certifications
IEC60601-1, ANSI/AAMI ES60601-1, IEC62638-1, UL62638-1, EN60601-1, EN62638-1, China GB4943
Environmental & Mechanical Specifications
Operating Temperature: 0°C to 40°C
Storage Temperature: -20°C to 60°C
Operating Humidity: 10% RH to 90% RH, non-condensing
Storage Humidity: 5% RH to 90% RH
Operating Altitude: up to 5,000 meters
Dielectric Withstand Voltage: 5,656VDC input to output
Insulation Resistance: 10M Ohms at 500VDC input to output
Short Circuit Protection: Trip and restart in hiccup mode
Additional Information
For more detailed specifications and datasheet, please visit the datasheet. Power supply does not include a line cord. Suitable for medical and industrial applications, ensuring compliance with relevant safety standards.
Note: The product is not medical equipment (applied parts). Medical product manufacturers should evaluate class B/BF/CF compliance of their end product.
Use left/right arrows to navigate the slideshow or swipe left/right if using a mobile device
Choosing a selection results in a full page refresh.
Press the space key then arrow keys to make a selection.
Shopping Cart
{"id":10026616521021,"title":"SLE65S1203N01","handle":"sle65s1203n01","description":"\u003ch3\u003eADVANCED ENERGY \/ SL POWER \/ CONDOR SLE65S1203N01 AC\/DC Desktop Adapter 12V 65W\u003c\/h3\u003e\n\u003cp\u003eEnsure reliable power delivery with the \u003cstrong\u003eSLE65S1203N01\u003c\/strong\u003e AC\/DC desktop power supply from \u003cstrong\u003eADVANCED ENERGY \/ SL POWER \/ CONDOR\u003c\/strong\u003e. Designed for industrial and medical applications, this high-efficiency power adapter provides a stable 12V output with a maximum power of 65W, meeting rigorous safety and performance standards.\u003c\/p\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eSingle output 12V, 5.4A power supply with 65W rated power\u003c\/li\u003e\n \u003cli\u003eMedical and industrial grade, compliant with IEC60601-1, IEC62638-1, UL62638-1 safety standards\u003c\/li\u003e\n \u003cli\u003eInput voltage range: 90VAC–264VAC, 47Hz–63Hz\u003c\/li\u003e\n \u003cli\u003eHigh efficiency: 89.0% average\u003c\/li\u003e\n \u003cli\u003eFast start-up time: ≤3 seconds\u003c\/li\u003e\n \u003cli\u003eOverload, overvoltage, and short circuit protection with auto-recovery\u003c\/li\u003e\n \u003cli\u003eCompact design: 125.0mm x 62.0mm x 34.0mm, weighing approximately 340 grams\u003c\/li\u003e\n \u003cli\u003eOperating temperature: 0°C to 40°C; Storage temperature: -20°C to 60°C\u003c\/li\u003e\n \u003cli\u003eRoHS compliant, ECCN: EAR99\u003c\/li\u003e\n \u003cli\u003ePackage Type: BOX\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n \u003cth\u003eModel Number\u003c\/th\u003e\n \u003cth\u003eVoltage\u003c\/th\u003e\n \u003cth\u003eCurrent\u003c\/th\u003e\n \u003cth\u003eRated Power\u003c\/th\u003e\n \u003cth\u003eRipple \u0026amp; Noise\u003c\/th\u003e\n \u003cth\u003eVoltage Tolerance\u003c\/th\u003e\n \u003cth\u003eLine \u0026amp; Load Regulation\u003c\/th\u003e\n \u003cth\u003eEfficiency (Average)\u003c\/th\u003e\n \u003cth\u003eStart Up Delay\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eSLE65S1203N01\u003c\/td\u003e\n \u003ctd\u003e12.0V\u003c\/td\u003e\n \u003ctd\u003e5.4A\u003c\/td\u003e\n \u003ctd\u003e65.04W\u003c\/td\u003e\n \u003ctd\u003e200mV pk-pk\u003c\/td\u003e\n \u003ctd\u003e±5%\u003c\/td\u003e\n \u003ctd\u003eLine: ±1%, Load: ±5%\u003c\/td\u003e\n \u003ctd\u003e89.0%\u003c\/td\u003e\n \u003ctd\u003e≤3s\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInput \u0026amp; Safety Standards\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n \u003cth\u003eInput Voltage \u0026amp; Frequency\u003c\/th\u003e\n \u003ctd\u003e90VAC–264VAC, 47Hz–63Hz\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eInput Current\u003c\/th\u003e\n \u003ctd\u003e2.0A at 90VAC\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eInrush Current\u003c\/th\u003e\n \u003ctd\u003e120A max at 240VAC cold start\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eTouch Leakage Current\u003c\/th\u003e\n \u003ctd\u003e≤100μA at 264VAC\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n \u003cth\u003eSafety Certifications\u003c\/th\u003e\n \u003ctd\u003eIEC60601-1, ANSI\/AAMI ES60601-1, IEC62638-1, UL62638-1, EN60601-1, EN62638-1, China GB4943\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEnvironmental \u0026amp; Mechanical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eOperating Temperature: 0°C to 40°C\u003c\/li\u003e\n \u003cli\u003eStorage Temperature: -20°C to 60°C\u003c\/li\u003e\n \u003cli\u003eOperating Humidity: 10% RH to 90% RH, non-condensing\u003c\/li\u003e\n \u003cli\u003eStorage Humidity: 5% RH to 90% RH\u003c\/li\u003e\n \u003cli\u003eOperating Altitude: up to 5,000 meters\u003c\/li\u003e\n \u003cli\u003eDielectric Withstand Voltage: 5,656VDC input to output\u003c\/li\u003e\n \u003cli\u003eInsulation Resistance: 10M Ohms at 500VDC input to output\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProtection \u0026amp; Compliance\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eOverload Protection: 120%–200% rated output power, auto-recovery\u003c\/li\u003e\n \u003cli\u003eOvervoltage Protection: 120%–200% rated output voltage, reset required\u003c\/li\u003e\n \u003cli\u003eShort Circuit Protection: Trip and restart in hiccup mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdditional Information\u003c\/h3\u003e\n\u003cp\u003eFor more detailed specifications and datasheet, please visit the \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-cod\/cod-sle65s1203n01.pdf\" target=\"_blank\"\u003edatasheet\u003c\/a\u003e. Power supply does not include a line cord. Suitable for medical and industrial applications, ensuring compliance with relevant safety standards.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: The product is not medical equipment (applied parts). Medical product manufacturers should evaluate class B\/BF\/CF compliance of their end product.\u003c\/em\u003e\u003c\/p\u003e\u003cbr\u003e","published_at":"2025-08-15T12:17:04+05:30","created_at":"2025-08-15T12:17:05+05:30","vendor":"Waldom Electonics","type":"AC-DC Power Supply","tags":["12V","65W","AC","ADVAN-SLPO","Desktop","IMPORT_CSV","IMPORT_PT2","WLDM"],"price":283973,"price_min":283973,"price_max":283973,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50622719492413,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"SLE65S1203N01","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"SLE65S1203N01","public_title":null,"options":["Default Title"],"price":283973,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"SLE65S1203N01","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/SLE65S1203N01_54928385_ddaec415.jpg?v=1755240425"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/SLE65S1203N01_54928385_ddaec415.jpg?v=1755240425","options":["Title"],"media":[{"alt":null,"id":45850215350589,"position":1,"preview_image":{"aspect_ratio":1.24,"height":200,"width":248,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/SLE65S1203N01_54928385_ddaec415.jpg?v=1755240425"},"aspect_ratio":1.24,"height":200,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/SLE65S1203N01_54928385_ddaec415.jpg?v=1755240425","width":248}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eADVANCED ENERGY \/ SL POWER \/ CONDOR SLE65S1203N01 AC\/DC Desktop Adapter 12V 65W\u003c\/h3\u003e\n\u003cp\u003eEnsure reliable power delivery with the \u003cstrong\u003eSLE65S1203N01\u003c\/strong\u003e AC\/DC desktop power supply from \u003cstrong\u003eADVANCED ENERGY \/ SL POWER \/ CONDOR\u003c\/strong\u003e. Designed for industrial and medical applications, this high-efficiency power adapter provides a stable 12V output with a maximum power of 65W, meeting rigorous safety and performance standards.\u003c\/p\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eSingle output 12V, 5.4A power supply with 65W rated power\u003c\/li\u003e\n \u003cli\u003eMedical and industrial grade, compliant with IEC60601-1, IEC62638-1, UL62638-1 safety standards\u003c\/li\u003e\n \u003cli\u003eInput voltage range: 90VAC–264VAC, 47Hz–63Hz\u003c\/li\u003e\n \u003cli\u003eHigh efficiency: 89.0% average\u003c\/li\u003e\n \u003cli\u003eFast start-up time: ≤3 seconds\u003c\/li\u003e\n \u003cli\u003eOverload, overvoltage, and short circuit protection with auto-recovery\u003c\/li\u003e\n \u003cli\u003eCompact design: 125.0mm x 62.0mm x 34.0mm, weighing approximately 340 grams\u003c\/li\u003e\n \u003cli\u003eOperating temperature: 0°C to 40°C; Storage temperature: -20°C to 60°C\u003c\/li\u003e\n \u003cli\u003eRoHS compliant, ECCN: EAR99\u003c\/li\u003e\n \u003cli\u003ePackage Type: BOX\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n \u003cth\u003eModel Number\u003c\/th\u003e\n \u003cth\u003eVoltage\u003c\/th\u003e\n \u003cth\u003eCurrent\u003c\/th\u003e\n \u003cth\u003eRated Power\u003c\/th\u003e\n \u003cth\u003eRipple \u0026amp; Noise\u003c\/th\u003e\n \u003cth\u003eVoltage Tolerance\u003c\/th\u003e\n \u003cth\u003eLine \u0026amp; Load Regulation\u003c\/th\u003e\n \u003cth\u003eEfficiency (Average)\u003c\/th\u003e\n \u003cth\u003eStart Up Delay\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eSLE65S1203N01\u003c\/td\u003e\n \u003ctd\u003e12.0V\u003c\/td\u003e\n \u003ctd\u003e5.4A\u003c\/td\u003e\n \u003ctd\u003e65.04W\u003c\/td\u003e\n \u003ctd\u003e200mV pk-pk\u003c\/td\u003e\n \u003ctd\u003e±5%\u003c\/td\u003e\n \u003ctd\u003eLine: ±1%, Load: ±5%\u003c\/td\u003e\n \u003ctd\u003e89.0%\u003c\/td\u003e\n \u003ctd\u003e≤3s\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInput \u0026amp; Safety Standards\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n \u003cth\u003eInput Voltage \u0026amp; Frequency\u003c\/th\u003e\n \u003ctd\u003e90VAC–264VAC, 47Hz–63Hz\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eInput Current\u003c\/th\u003e\n \u003ctd\u003e2.0A at 90VAC\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eInrush Current\u003c\/th\u003e\n \u003ctd\u003e120A max at 240VAC cold start\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eTouch Leakage Current\u003c\/th\u003e\n \u003ctd\u003e≤100μA at 264VAC\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n \u003cth\u003eSafety Certifications\u003c\/th\u003e\n \u003ctd\u003eIEC60601-1, ANSI\/AAMI ES60601-1, IEC62638-1, UL62638-1, EN60601-1, EN62638-1, China GB4943\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEnvironmental \u0026amp; Mechanical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eOperating Temperature: 0°C to 40°C\u003c\/li\u003e\n \u003cli\u003eStorage Temperature: -20°C to 60°C\u003c\/li\u003e\n \u003cli\u003eOperating Humidity: 10% RH to 90% RH, non-condensing\u003c\/li\u003e\n \u003cli\u003eStorage Humidity: 5% RH to 90% RH\u003c\/li\u003e\n \u003cli\u003eOperating Altitude: up to 5,000 meters\u003c\/li\u003e\n \u003cli\u003eDielectric Withstand Voltage: 5,656VDC input to output\u003c\/li\u003e\n \u003cli\u003eInsulation Resistance: 10M Ohms at 500VDC input to output\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProtection \u0026amp; Compliance\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eOverload Protection: 120%–200% rated output power, auto-recovery\u003c\/li\u003e\n \u003cli\u003eOvervoltage Protection: 120%–200% rated output voltage, reset required\u003c\/li\u003e\n \u003cli\u003eShort Circuit Protection: Trip and restart in hiccup mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdditional Information\u003c\/h3\u003e\n\u003cp\u003eFor more detailed specifications and datasheet, please visit the \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-cod\/cod-sle65s1203n01.pdf\" target=\"_blank\"\u003edatasheet\u003c\/a\u003e. Power supply does not include a line cord. Suitable for medical and industrial applications, ensuring compliance with relevant safety standards.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: The product is not medical equipment (applied parts). Medical product manufacturers should evaluate class B\/BF\/CF compliance of their end product.\u003c\/em\u003e\u003c\/p\u003e\u003cbr\u003e"}