The AIRPAX / SENSATA JLE Series Magnetic Hydraulic Circuit Protectors are high-performance circuit breakers designed for reliable protection in demanding high-current applications. Manufactured in Malaysia, these circuit protectors comply with international safety standards and are RoHS certified, ensuring environmentally responsible manufacturing.
Key Features:
UL 489 Listed and UL 489A Listed for safety and reliability
CSA, CUL/CUR, VDE, CCC, and ISO-9001 certifications
Available in 1 to 6 pole configurations with various terminal styles for versatile installation
Rated currents from 100A to 1200A with voltage ratings up to 250Vdc
Interrupting capacities up to 100,000 amps at 65Vdc
Consistent trip points over temperature ranges from –40°C to +85°C
Optional internal low voltage shunt for current metering
Electrical and mechanical auxiliary switch options for external circuit monitoring
Reduced voltage drop compared to other circuit protective devices
Mid-trip handle for easy fault identification
Technical Specifications:
Poles
1, 2, 3, 4, 5, 6
Current Ratings
100 to 250A (up to 160Vdc), 275 to 1200A (paralleled poles)
Voltage Ratings
65Vdc, 125Vdc, 160Vdc
Interrupting Capacity
10,000A to 100,000A depending on voltage and current ratings
Package Type
Black (BLK)
UOM
Each (EA)
ECCN
EAR99
COO
MY (Malaysia)
Additional Details:
Designed to operate reliably over a wide temperature range from –40°C to +85°C
Multiple terminal options and configurations for flexible integration
For more detailed technical information, please refer to the datasheet linked above. The datasheet was not processed; please search the internet for the part number JLE-1-1REC4-40063-150-V for comprehensive details.
{"id":10024555938109,"title":"JLE-1-1REC4-40063-150-V","handle":"jle-1-1rec4-40063-150-v","description":"\u003ch3\u003eProduct Description: AIRPAX \/ SENSATA CIR BRKR MAG-HYDR (Part Number: JLE-1-1REC4-40063-150-V)\u003c\/h3\u003e\n\n\u003cp\u003eThe AIRPAX \/ SENSATA JLE Series Magnetic Hydraulic Circuit Protectors are high-performance circuit breakers designed for reliable protection in demanding high-current applications. Manufactured in Malaysia, these circuit protectors comply with international safety standards and are RoHS certified, ensuring environmentally responsible manufacturing.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eUL 489 Listed and UL 489A Listed for safety and reliability\u003c\/li\u003e\n \u003cli\u003eCSA, CUL\/CUR, VDE, CCC, and ISO-9001 certifications\u003c\/li\u003e\n \u003cli\u003eAvailable in 1 to 6 pole configurations with various terminal styles for versatile installation\u003c\/li\u003e\n \u003cli\u003eRated currents from 100A to 1200A with voltage ratings up to 250Vdc\u003c\/li\u003e\n \u003cli\u003eInterrupting capacities up to 100,000 amps at 65Vdc\u003c\/li\u003e\n \u003cli\u003eConsistent trip points over temperature ranges from –40°C to +85°C\u003c\/li\u003e\n \u003cli\u003eOptional internal low voltage shunt for current metering\u003c\/li\u003e\n \u003cli\u003eElectrical and mechanical auxiliary switch options for external circuit monitoring\u003c\/li\u003e\n \u003cli\u003eReduced voltage drop compared to other circuit protective devices\u003c\/li\u003e\n \u003cli\u003eMid-trip handle for easy fault identification\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications:\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n \u003cth\u003ePoles\u003c\/th\u003e\n \u003ctd\u003e1, 2, 3, 4, 5, 6\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eCurrent Ratings\u003c\/th\u003e\n \u003ctd\u003e100 to 250A (up to 160Vdc), 275 to 1200A (paralleled poles)\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eVoltage Ratings\u003c\/th\u003e\n \u003ctd\u003e65Vdc, 125Vdc, 160Vdc\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eInterrupting Capacity\u003c\/th\u003e\n \u003ctd\u003e10,000A to 100,000A depending on voltage and current ratings\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003ePackage Type\u003c\/th\u003e\n \u003ctd\u003eBlack (BLK)\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eUOM\u003c\/th\u003e\n \u003ctd\u003eEach (EA)\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eECCN\u003c\/th\u003e\n \u003ctd\u003eEAR99\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eCOO\u003c\/th\u003e\n \u003ctd\u003eMY (Malaysia)\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eAdditional Details:\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eDesigned to operate reliably over a wide temperature range from –40°C to +85°C\u003c\/li\u003e\n \u003cli\u003eMultiple terminal options and configurations for flexible integration\u003c\/li\u003e\n \u003cli\u003eDatasheet available for detailed specifications and configurations: \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-ai\/jle.pdf\" target=\"_blank\"\u003eJAE\/JRE\/JLE Series Magnetic Circuit Protectors Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eFor more detailed technical information, please refer to the datasheet linked above. The datasheet was not processed; please search the internet for the part number \u003cstrong\u003eJLE-1-1REC4-40063-150-V\u003c\/strong\u003e for comprehensive details.\u003c\/p\u003e\u003cbr\u003e","published_at":"2025-08-14T08:05:38+05:30","created_at":"2025-08-14T08:05:38+05:30","vendor":"Waldom Electonics","type":"Circuit Protection","tags":["AIRPA-SENS","CIR","Circuit","IMPORT_CSV","WLDM"],"price":4873414,"price_min":4873414,"price_max":4873414,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50618611794237,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"JLE-1-1REC4-40063-150-V","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"JLE-1-1REC4-40063-150-V","public_title":null,"options":["Default Title"],"price":4873414,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"JLE-1-1REC4-40063-150-V","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/49501823.jpg?v=1755138940"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/49501823.jpg?v=1755138940","options":["Title"],"media":[{"alt":null,"id":45829940052285,"position":1,"preview_image":{"aspect_ratio":1.0,"height":400,"width":400,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/49501823.jpg?v=1755138940"},"aspect_ratio":1.0,"height":400,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/49501823.jpg?v=1755138940","width":400}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eProduct Description: AIRPAX \/ SENSATA CIR BRKR MAG-HYDR (Part Number: JLE-1-1REC4-40063-150-V)\u003c\/h3\u003e\n\n\u003cp\u003eThe AIRPAX \/ SENSATA JLE Series Magnetic Hydraulic Circuit Protectors are high-performance circuit breakers designed for reliable protection in demanding high-current applications. Manufactured in Malaysia, these circuit protectors comply with international safety standards and are RoHS certified, ensuring environmentally responsible manufacturing.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eUL 489 Listed and UL 489A Listed for safety and reliability\u003c\/li\u003e\n \u003cli\u003eCSA, CUL\/CUR, VDE, CCC, and ISO-9001 certifications\u003c\/li\u003e\n \u003cli\u003eAvailable in 1 to 6 pole configurations with various terminal styles for versatile installation\u003c\/li\u003e\n \u003cli\u003eRated currents from 100A to 1200A with voltage ratings up to 250Vdc\u003c\/li\u003e\n \u003cli\u003eInterrupting capacities up to 100,000 amps at 65Vdc\u003c\/li\u003e\n \u003cli\u003eConsistent trip points over temperature ranges from –40°C to +85°C\u003c\/li\u003e\n \u003cli\u003eOptional internal low voltage shunt for current metering\u003c\/li\u003e\n \u003cli\u003eElectrical and mechanical auxiliary switch options for external circuit monitoring\u003c\/li\u003e\n \u003cli\u003eReduced voltage drop compared to other circuit protective devices\u003c\/li\u003e\n \u003cli\u003eMid-trip handle for easy fault identification\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications:\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n \u003cth\u003ePoles\u003c\/th\u003e\n \u003ctd\u003e1, 2, 3, 4, 5, 6\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eCurrent Ratings\u003c\/th\u003e\n \u003ctd\u003e100 to 250A (up to 160Vdc), 275 to 1200A (paralleled poles)\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eVoltage Ratings\u003c\/th\u003e\n \u003ctd\u003e65Vdc, 125Vdc, 160Vdc\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eInterrupting Capacity\u003c\/th\u003e\n \u003ctd\u003e10,000A to 100,000A depending on voltage and current ratings\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003ePackage Type\u003c\/th\u003e\n \u003ctd\u003eBlack (BLK)\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eUOM\u003c\/th\u003e\n \u003ctd\u003eEach (EA)\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eECCN\u003c\/th\u003e\n \u003ctd\u003eEAR99\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eCOO\u003c\/th\u003e\n \u003ctd\u003eMY (Malaysia)\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eAdditional Details:\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eDesigned to operate reliably over a wide temperature range from –40°C to +85°C\u003c\/li\u003e\n \u003cli\u003eMultiple terminal options and configurations for flexible integration\u003c\/li\u003e\n \u003cli\u003eDatasheet available for detailed specifications and configurations: \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-ai\/jle.pdf\" target=\"_blank\"\u003eJAE\/JRE\/JLE Series Magnetic Circuit Protectors Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eFor more detailed technical information, please refer to the datasheet linked above. The datasheet was not processed; please search the internet for the part number \u003cstrong\u003eJLE-1-1REC4-40063-150-V\u003c\/strong\u003e for comprehensive details.\u003c\/p\u003e\u003cbr\u003e"}