From 1 second to 150 seconds depending on model and trip curve
Mechanical and Mounting Details
Size: Approximately 0.66" x 1.38" x 1.38" (16.8 x 34.9 x 34.9 mm)
Weight: Ranges from 1.5 oz to 2.5 oz depending on model
Mounting options include threaded bushings, snap-in, and tapped holes
Terminals include quick connect, screw, and PCB options
Additional Information
RoHS compliant
UL Recognized for ignition protection and supplementary protection standards
Business Unit: Industrial
For more detailed specifications and application information, please refer to the datasheet.
Note: All specifications are subject to change without notice. Please consult the datasheet or contact technical support for the most current information.
{"id":10026423124285,"title":"1-1393249-9","handle":"1-1393249-9","description":"\u003ch3\u003eTE CONNECTIVITY\/AMP BRAND CIR BRKR THRM 5A 250VAC 50VDC\u003c\/h3\u003e\n\u003cp\u003ePart Number: 1-1393249-9\u003c\/p\u003e\n\u003cp\u003eManufacturer: TE CONNECTIVITY\/AMP BRAND\u003c\/p\u003e\n\u003cp\u003eCountry of Origin: CN\u003c\/p\u003e\n\u003cp\u003eUnit of Measure: EA\u003c\/p\u003e\n\u003cp\u003eECCN: EAR99\u003c\/p\u003e\n\u003cp\u003ePackage Type: TRAY\u003c\/p\u003e\n\u003cp\u003eProduct Type: Circuit Protection\u003c\/p\u003e\n\u003cp\u003eProduct Category: Circuit Protection | Circuit Breakers\u003c\/p\u003e\n\u003cp\u003eDatasheet: \u003ca href=\"https:\/\/www.te.com\/commerce\/DocumentDelivery\/DDEController?Action=srchrtrv\u0026amp;DocNm=6-1773453-2_UL1500_Breaker_Flyer\u0026amp;DocType=Data+Sheet\u0026amp;DocLang=English\u0026amp;PartCntxt=1-1393249-9\u0026amp;DocFormat=pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eUL 1500 Ignition Protected Circuit Breaker suitable for marine applications\u003c\/li\u003e\n \u003cli\u003eRatings from 200 milliamps to 50 amps, with both magnetic (magnetic-hydraulic) and thermal types available\u003c\/li\u003e\n \u003cli\u003eMultiple termination options including quick connect terminals, screw terminals, PCB terminals, and studs\u003c\/li\u003e\n \u003cli\u003eVarious mounting options such as threaded bushings, snap-in, and threaded holes\u003c\/li\u003e\n \u003cli\u003eUL Recognized as supplementary protectors for US and Canada, meeting UL 1500 and UL 1077 standards\u003c\/li\u003e\n \u003cli\u003eMaximum operating voltages: 50V DC and 250V AC; interrupt capacities up to 3000A @ 48VDC\u003c\/li\u003e\n \u003cli\u003ePush-to-reset operation with visible trip indication\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eElectrical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n \u003ctr\u003e\n \u003cth\u003eCurrent Ratings\u003c\/th\u003e\n \u003ctd\u003e0.5 to 40 amps (thermal models), 0.2 to 50 amps (magnetic types)\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eMaximum Operating Voltage\u003c\/th\u003e\n \u003ctd\u003e50V DC, 250V AC\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eInterrupt Capacity\u003c\/th\u003e\n \u003ctd\u003e2000A (thermal types), 3000A @ 48VDC, 1000A @ 125\/250VAC or 250VAC 3-phase Wye (magnetic types)\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eTrip Time\u003c\/th\u003e\n \u003ctd\u003eFrom 1 second to 150 seconds depending on model and trip curve\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eMechanical and Mounting Details\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eSize: Approximately 0.66\" x 1.38\" x 1.38\" (16.8 x 34.9 x 34.9 mm)\u003c\/li\u003e\n \u003cli\u003eWeight: Ranges from 1.5 oz to 2.5 oz depending on model\u003c\/li\u003e\n \u003cli\u003eMounting options include threaded bushings, snap-in, and tapped holes\u003c\/li\u003e\n \u003cli\u003eTerminals include quick connect, screw, and PCB options\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAdditional Information\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eRoHS compliant\u003c\/li\u003e\n \u003cli\u003eUL Recognized for ignition protection and supplementary protection standards\u003c\/li\u003e\n \u003cli\u003eBusiness Unit: Industrial\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eFor more detailed specifications and application information, please refer to the \u003ca href=\"https:\/\/www.te.com\/commerce\/DocumentDelivery\/DDEController?Action=srchrtrv\u0026amp;DocNm=6-1773453-2_UL1500_Breaker_Flyer\u0026amp;DocType=Data+Sheet\u0026amp;DocLang=English\u0026amp;PartCntxt=1-1393249-9\u0026amp;DocFormat=pdf\" target=\"_blank\"\u003edatasheet\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cp\u003eNote: All specifications are subject to change without notice. Please consult the datasheet or contact technical support for the most current information.\u003c\/p\u003e","published_at":"2025-08-15T08:09:55+05:30","created_at":"2025-08-15T08:09:57+05:30","vendor":"Waldom Electonics","type":"Circuit Protection","tags":["IMPORT_CSV","IMPORT_PT2","WLDM"],"price":86204,"price_min":86204,"price_max":86204,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50622262051133,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"1-1393249-9","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"1-1393249-9","public_title":null,"options":["Default Title"],"price":86204,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"1-1393249-9","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/1-1393249-9_10147154_17fcf60d.jpg?v=1755225597"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/1-1393249-9_10147154_17fcf60d.jpg?v=1755225597","options":["Title"],"media":[{"alt":null,"id":45847991976253,"position":1,"preview_image":{"aspect_ratio":1.755,"height":200,"width":351,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/1-1393249-9_10147154_17fcf60d.jpg?v=1755225597"},"aspect_ratio":1.755,"height":200,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/1-1393249-9_10147154_17fcf60d.jpg?v=1755225597","width":351}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eTE CONNECTIVITY\/AMP BRAND CIR BRKR THRM 5A 250VAC 50VDC\u003c\/h3\u003e\n\u003cp\u003ePart Number: 1-1393249-9\u003c\/p\u003e\n\u003cp\u003eManufacturer: TE CONNECTIVITY\/AMP BRAND\u003c\/p\u003e\n\u003cp\u003eCountry of Origin: CN\u003c\/p\u003e\n\u003cp\u003eUnit of Measure: EA\u003c\/p\u003e\n\u003cp\u003eECCN: EAR99\u003c\/p\u003e\n\u003cp\u003ePackage Type: TRAY\u003c\/p\u003e\n\u003cp\u003eProduct Type: Circuit Protection\u003c\/p\u003e\n\u003cp\u003eProduct Category: Circuit Protection | Circuit Breakers\u003c\/p\u003e\n\u003cp\u003eDatasheet: \u003ca href=\"https:\/\/www.te.com\/commerce\/DocumentDelivery\/DDEController?Action=srchrtrv\u0026amp;DocNm=6-1773453-2_UL1500_Breaker_Flyer\u0026amp;DocType=Data+Sheet\u0026amp;DocLang=English\u0026amp;PartCntxt=1-1393249-9\u0026amp;DocFormat=pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eUL 1500 Ignition Protected Circuit Breaker suitable for marine applications\u003c\/li\u003e\n \u003cli\u003eRatings from 200 milliamps to 50 amps, with both magnetic (magnetic-hydraulic) and thermal types available\u003c\/li\u003e\n \u003cli\u003eMultiple termination options including quick connect terminals, screw terminals, PCB terminals, and studs\u003c\/li\u003e\n \u003cli\u003eVarious mounting options such as threaded bushings, snap-in, and threaded holes\u003c\/li\u003e\n \u003cli\u003eUL Recognized as supplementary protectors for US and Canada, meeting UL 1500 and UL 1077 standards\u003c\/li\u003e\n \u003cli\u003eMaximum operating voltages: 50V DC and 250V AC; interrupt capacities up to 3000A @ 48VDC\u003c\/li\u003e\n \u003cli\u003ePush-to-reset operation with visible trip indication\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eElectrical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n \u003ctr\u003e\n \u003cth\u003eCurrent Ratings\u003c\/th\u003e\n \u003ctd\u003e0.5 to 40 amps (thermal models), 0.2 to 50 amps (magnetic types)\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eMaximum Operating Voltage\u003c\/th\u003e\n \u003ctd\u003e50V DC, 250V AC\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eInterrupt Capacity\u003c\/th\u003e\n \u003ctd\u003e2000A (thermal types), 3000A @ 48VDC, 1000A @ 125\/250VAC or 250VAC 3-phase Wye (magnetic types)\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eTrip Time\u003c\/th\u003e\n \u003ctd\u003eFrom 1 second to 150 seconds depending on model and trip curve\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eMechanical and Mounting Details\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eSize: Approximately 0.66\" x 1.38\" x 1.38\" (16.8 x 34.9 x 34.9 mm)\u003c\/li\u003e\n \u003cli\u003eWeight: Ranges from 1.5 oz to 2.5 oz depending on model\u003c\/li\u003e\n \u003cli\u003eMounting options include threaded bushings, snap-in, and tapped holes\u003c\/li\u003e\n \u003cli\u003eTerminals include quick connect, screw, and PCB options\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAdditional Information\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eRoHS compliant\u003c\/li\u003e\n \u003cli\u003eUL Recognized for ignition protection and supplementary protection standards\u003c\/li\u003e\n \u003cli\u003eBusiness Unit: Industrial\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eFor more detailed specifications and application information, please refer to the \u003ca href=\"https:\/\/www.te.com\/commerce\/DocumentDelivery\/DDEController?Action=srchrtrv\u0026amp;DocNm=6-1773453-2_UL1500_Breaker_Flyer\u0026amp;DocType=Data+Sheet\u0026amp;DocLang=English\u0026amp;PartCntxt=1-1393249-9\u0026amp;DocFormat=pdf\" target=\"_blank\"\u003edatasheet\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cp\u003eNote: All specifications are subject to change without notice. Please consult the datasheet or contact technical support for the most current information.\u003c\/p\u003e"}