TE Connectivity/AMP Brand Circuit Breakers W68-X2Q110-10 M6/M7/M9/W6/W7
Ensure reliable circuit protection with the TE Connectivity (TE) AMP Series W68-X2Q110-10 M6/M7/M9/W6/W7 magnetic hydraulic circuit breakers. Designed for international applications, these circuit breakers offer versatile configurations and multiple trip curve options to suit a wide range of industrial and electrical needs.
Product Features
Ratings up to 50 Amps, suitable for various circuit protection applications
UL Recognized (UL1077), CSA accepted, and VDE approved for international compliance
Heavy-duty #10-32 stud connections (W9 model)
Quick-connect or screw terminal options (W6 model)
Multiple delay curve options for tailored trip characteristics
Trip-free operation ensures safety and reliability
Electrical and Mechanical Specifications
Characteristic
Specification
Calibration
Breakers hold 100% of rated current; trip between 101% and 124% of rated load (134% for AC/DC units). Trip at 125% and above (135% for AC/DC units).
Dielectric Strength
1500V at 50/60 Hz; 1100V DC
Insulation Resistance
100 Megaohms at 500VDC
Endurance
10,000 on/off cycles (6000 at rated load, 4000 at no load)
Operating Temperature
-40°C to +85°C
Humidity
Meets Mil-STD-202 method 103
Shock
Tested per Mil-STD-202, method 213, test condition C (100g @ 6 ms)
Vibration
Tested per Mil-STD-202, method 201, 10-55 Hz, 0.06” (1.52mm) excursion
Fungus & Moisture Resistance
Moisture resistant finish; fungus resistant plastic parts
Mounting
Two #6-32 screws from front; optional metric models with M3 x 0.5 screws
Weight
Approximately 2.5 ounces per pole
Approval and Ratings
Series
Voltage (V)
Frequency (Hz)
Phase
Current Rating (Amps)
Interrupting Capacity (Amps)
W6 Series
65, 277, 277/480
50/60
-
0.2 - 50
2,000 - 5,000
W9 Series
65, 277, 277/480
50/60
-
0.2 - 50
2,000 - 5,000
VDE (Circuit Function X)
65, 250, 415/240
50/60
-
0.2 - 50
2,000 - 5,000
Trip Curves and Timing
Includes various trip curves such as instant, standard delay, short delay, and high inrush, suitable for different operational requirements. Refer to the datasheet for detailed trip time characteristics and curves.
Physical Dimensions
Outline dimensions and mounting details are available in the datasheet. Models are designed for panel mounting with specific cutout dimensions and terminal configurations.
{"id":10026423517501,"title":"1-1393253-7","handle":"1-1393253-7","description":"\u003ch3\u003eTE Connectivity\/AMP Brand Circuit Breakers W68-X2Q110-10 M6\/M7\/M9\/W6\/W7\u003c\/h3\u003e\n\n\u003cp\u003eEnsure reliable circuit protection with the TE Connectivity (TE) AMP Series W68-X2Q110-10 M6\/M7\/M9\/W6\/W7 magnetic hydraulic circuit breakers. Designed for international applications, these circuit breakers offer versatile configurations and multiple trip curve options to suit a wide range of industrial and electrical needs.\u003c\/p\u003e\n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eRatings up to 50 Amps, suitable for various circuit protection applications\u003c\/li\u003e\n \u003cli\u003eUL Recognized (UL1077), CSA accepted, and VDE approved for international compliance\u003c\/li\u003e\n \u003cli\u003eHeavy-duty #10-32 stud connections (W9 model)\u003c\/li\u003e\n \u003cli\u003eQuick-connect or screw terminal options (W6 model)\u003c\/li\u003e\n \u003cli\u003eMultiple delay curve options for tailored trip characteristics\u003c\/li\u003e\n \u003cli\u003eTrip-free operation ensures safety and reliability\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eElectrical and Mechanical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n \u003cth\u003eCharacteristic\u003c\/th\u003e\n \u003cth\u003eSpecification\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eCalibration\u003c\/td\u003e\n \u003ctd\u003eBreakers hold 100% of rated current; trip between 101% and 124% of rated load (134% for AC\/DC units). Trip at 125% and above (135% for AC\/DC units).\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eDielectric Strength\u003c\/td\u003e\n \u003ctd\u003e1500V at 50\/60 Hz; 1100V DC\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n \u003ctd\u003e100 Megaohms at 500VDC\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eEndurance\u003c\/td\u003e\n \u003ctd\u003e10,000 on\/off cycles (6000 at rated load, 4000 at no load)\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n \u003ctd\u003e-40°C to +85°C\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eHumidity\u003c\/td\u003e\n \u003ctd\u003eMeets Mil-STD-202 method 103\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eShock\u003c\/td\u003e\n \u003ctd\u003eTested per Mil-STD-202, method 213, test condition C (100g @ 6 ms)\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eVibration\u003c\/td\u003e\n \u003ctd\u003eTested per Mil-STD-202, method 201, 10-55 Hz, 0.06” (1.52mm) excursion\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eFungus \u0026amp; Moisture Resistance\u003c\/td\u003e\n \u003ctd\u003eMoisture resistant finish; fungus resistant plastic parts\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eMounting\u003c\/td\u003e\n \u003ctd\u003eTwo #6-32 screws from front; optional metric models with M3 x 0.5 screws\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eWeight\u003c\/td\u003e\n \u003ctd\u003eApproximately 2.5 ounces per pole\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApproval and Ratings\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n \u003cth\u003eSeries\u003c\/th\u003e\n \u003cth\u003eVoltage (V)\u003c\/th\u003e\n \u003cth\u003eFrequency (Hz)\u003c\/th\u003e\n \u003cth\u003ePhase\u003c\/th\u003e\n \u003cth\u003eCurrent Rating (Amps)\u003c\/th\u003e\n \u003cth\u003eInterrupting Capacity (Amps)\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eW6 Series\u003c\/td\u003e\n \u003ctd\u003e65, 277, 277\/480\u003c\/td\u003e\n \u003ctd\u003e50\/60\u003c\/td\u003e\n \u003ctd\u003e-\u003c\/td\u003e\n \u003ctd\u003e0.2 - 50\u003c\/td\u003e\n \u003ctd\u003e2,000 - 5,000\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eW9 Series\u003c\/td\u003e\n \u003ctd\u003e65, 277, 277\/480\u003c\/td\u003e\n \u003ctd\u003e50\/60\u003c\/td\u003e\n \u003ctd\u003e-\u003c\/td\u003e\n \u003ctd\u003e0.2 - 50\u003c\/td\u003e\n \u003ctd\u003e2,000 - 5,000\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eVDE (Circuit Function X)\u003c\/td\u003e\n \u003ctd\u003e65, 250, 415\/240\u003c\/td\u003e\n \u003ctd\u003e50\/60\u003c\/td\u003e\n \u003ctd\u003e-\u003c\/td\u003e\n \u003ctd\u003e0.2 - 50\u003c\/td\u003e\n \u003ctd\u003e2,000 - 5,000\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTrip Curves and Timing\u003c\/h3\u003e\n\u003cp\u003eIncludes various trip curves such as instant, standard delay, short delay, and high inrush, suitable for different operational requirements. Refer to the datasheet for detailed trip time characteristics and curves.\u003c\/p\u003e\n\n\u003ch3\u003ePhysical Dimensions\u003c\/h3\u003e\n\u003cp\u003eOutline dimensions and mounting details are available in the datasheet. Models are designed for panel mounting with specific cutout dimensions and terminal configurations.\u003c\/p\u003e\n\n\u003ch3\u003eAdditional Information\u003c\/h3\u003e\n\u003cp\u003ePackage Type: Tray\u003c\/p\u003e\n\u003cp\u003ePart Number: 1-1393253-7\u003c\/p\u003e\n\u003cp\u003eManufacturer: TE CONNECTIVITY\/AMP BRAND\u003c\/p\u003e\n\u003cp\u003eCountry of Origin: MX\u003c\/p\u003e\n\u003cp\u003eUOM: EA\u003c\/p\u003e\n\u003cp\u003eECCN: EAR99\u003c\/p\u003e\n\u003cp\u003eDatasheet: \u003ca href=\"https:\/\/www.te.com\/commerce\/DocumentDelivery\/DDEController?Action=srchrtrv\u0026amp;DocNm=1308242_w6w9\u0026amp;DocType=Data+Sheet\u0026amp;DocLang=English\u0026amp;PartCntxt=1-1393253-7\u0026amp;DocFormat=pdf\" target=\"_blank\"\u003eView Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cem\u003eNote: Please review the technical data and approval documents before selecting this product for your application.\u003c\/em\u003e\u003c\/p\u003e","published_at":"2025-08-15T08:10:39+05:30","created_at":"2025-08-15T08:10:40+05:30","vendor":"Waldom Electonics","type":"Circuit Protection","tags":["IMPORT_CSV","IMPORT_PT2","WLDM"],"price":1585897,"price_min":1585897,"price_max":1585897,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50622262444349,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"1-1393253-7","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"1-1393253-7","public_title":null,"options":["Default Title"],"price":1585897,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"1-1393253-7","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/1-1393253-7_10147181_7af79cb1.jpg?v=1755225640"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/1-1393253-7_10147181_7af79cb1.jpg?v=1755225640","options":["Title"],"media":[{"alt":null,"id":45847997415741,"position":1,"preview_image":{"aspect_ratio":1.755,"height":200,"width":351,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/1-1393253-7_10147181_7af79cb1.jpg?v=1755225640"},"aspect_ratio":1.755,"height":200,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/1-1393253-7_10147181_7af79cb1.jpg?v=1755225640","width":351}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eTE Connectivity\/AMP Brand Circuit Breakers W68-X2Q110-10 M6\/M7\/M9\/W6\/W7\u003c\/h3\u003e\n\n\u003cp\u003eEnsure reliable circuit protection with the TE Connectivity (TE) AMP Series W68-X2Q110-10 M6\/M7\/M9\/W6\/W7 magnetic hydraulic circuit breakers. Designed for international applications, these circuit breakers offer versatile configurations and multiple trip curve options to suit a wide range of industrial and electrical needs.\u003c\/p\u003e\n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eRatings up to 50 Amps, suitable for various circuit protection applications\u003c\/li\u003e\n \u003cli\u003eUL Recognized (UL1077), CSA accepted, and VDE approved for international compliance\u003c\/li\u003e\n \u003cli\u003eHeavy-duty #10-32 stud connections (W9 model)\u003c\/li\u003e\n \u003cli\u003eQuick-connect or screw terminal options (W6 model)\u003c\/li\u003e\n \u003cli\u003eMultiple delay curve options for tailored trip characteristics\u003c\/li\u003e\n \u003cli\u003eTrip-free operation ensures safety and reliability\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eElectrical and Mechanical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n \u003cth\u003eCharacteristic\u003c\/th\u003e\n \u003cth\u003eSpecification\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eCalibration\u003c\/td\u003e\n \u003ctd\u003eBreakers hold 100% of rated current; trip between 101% and 124% of rated load (134% for AC\/DC units). Trip at 125% and above (135% for AC\/DC units).\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eDielectric Strength\u003c\/td\u003e\n \u003ctd\u003e1500V at 50\/60 Hz; 1100V DC\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n \u003ctd\u003e100 Megaohms at 500VDC\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eEndurance\u003c\/td\u003e\n \u003ctd\u003e10,000 on\/off cycles (6000 at rated load, 4000 at no load)\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n \u003ctd\u003e-40°C to +85°C\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eHumidity\u003c\/td\u003e\n \u003ctd\u003eMeets Mil-STD-202 method 103\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eShock\u003c\/td\u003e\n \u003ctd\u003eTested per Mil-STD-202, method 213, test condition C (100g @ 6 ms)\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eVibration\u003c\/td\u003e\n \u003ctd\u003eTested per Mil-STD-202, method 201, 10-55 Hz, 0.06” (1.52mm) excursion\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eFungus \u0026amp; Moisture Resistance\u003c\/td\u003e\n \u003ctd\u003eMoisture resistant finish; fungus resistant plastic parts\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eMounting\u003c\/td\u003e\n \u003ctd\u003eTwo #6-32 screws from front; optional metric models with M3 x 0.5 screws\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eWeight\u003c\/td\u003e\n \u003ctd\u003eApproximately 2.5 ounces per pole\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApproval and Ratings\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n \u003cth\u003eSeries\u003c\/th\u003e\n \u003cth\u003eVoltage (V)\u003c\/th\u003e\n \u003cth\u003eFrequency (Hz)\u003c\/th\u003e\n \u003cth\u003ePhase\u003c\/th\u003e\n \u003cth\u003eCurrent Rating (Amps)\u003c\/th\u003e\n \u003cth\u003eInterrupting Capacity (Amps)\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eW6 Series\u003c\/td\u003e\n \u003ctd\u003e65, 277, 277\/480\u003c\/td\u003e\n \u003ctd\u003e50\/60\u003c\/td\u003e\n \u003ctd\u003e-\u003c\/td\u003e\n \u003ctd\u003e0.2 - 50\u003c\/td\u003e\n \u003ctd\u003e2,000 - 5,000\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eW9 Series\u003c\/td\u003e\n \u003ctd\u003e65, 277, 277\/480\u003c\/td\u003e\n \u003ctd\u003e50\/60\u003c\/td\u003e\n \u003ctd\u003e-\u003c\/td\u003e\n \u003ctd\u003e0.2 - 50\u003c\/td\u003e\n \u003ctd\u003e2,000 - 5,000\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eVDE (Circuit Function X)\u003c\/td\u003e\n \u003ctd\u003e65, 250, 415\/240\u003c\/td\u003e\n \u003ctd\u003e50\/60\u003c\/td\u003e\n \u003ctd\u003e-\u003c\/td\u003e\n \u003ctd\u003e0.2 - 50\u003c\/td\u003e\n \u003ctd\u003e2,000 - 5,000\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTrip Curves and Timing\u003c\/h3\u003e\n\u003cp\u003eIncludes various trip curves such as instant, standard delay, short delay, and high inrush, suitable for different operational requirements. Refer to the datasheet for detailed trip time characteristics and curves.\u003c\/p\u003e\n\n\u003ch3\u003ePhysical Dimensions\u003c\/h3\u003e\n\u003cp\u003eOutline dimensions and mounting details are available in the datasheet. Models are designed for panel mounting with specific cutout dimensions and terminal configurations.\u003c\/p\u003e\n\n\u003ch3\u003eAdditional Information\u003c\/h3\u003e\n\u003cp\u003ePackage Type: Tray\u003c\/p\u003e\n\u003cp\u003ePart Number: 1-1393253-7\u003c\/p\u003e\n\u003cp\u003eManufacturer: TE CONNECTIVITY\/AMP BRAND\u003c\/p\u003e\n\u003cp\u003eCountry of Origin: MX\u003c\/p\u003e\n\u003cp\u003eUOM: EA\u003c\/p\u003e\n\u003cp\u003eECCN: EAR99\u003c\/p\u003e\n\u003cp\u003eDatasheet: \u003ca href=\"https:\/\/www.te.com\/commerce\/DocumentDelivery\/DDEController?Action=srchrtrv\u0026amp;DocNm=1308242_w6w9\u0026amp;DocType=Data+Sheet\u0026amp;DocLang=English\u0026amp;PartCntxt=1-1393253-7\u0026amp;DocFormat=pdf\" target=\"_blank\"\u003eView Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cem\u003eNote: Please review the technical data and approval documents before selecting this product for your application.\u003c\/em\u003e\u003c\/p\u003e"}