Part Number: 1-1415075-1
Manufacturer: TE CONNECTIVITY/AMP BRAND
Country of Origin: AT
Unit of Measure: EA
ECCN: EAR99
Package Type: BLK
Datasheet: View Datasheet
Product Features
Relays packaged with PT relay, DIN-rail socket, plastic retaining clip, module, and marking tag for easy installation and field repairs
Available configurations include 2 pole (12 A), 3 pole (10 A), and 4 pole (6 A)
Coil options for DC and AC voltages
Mechanical and electrical indicators for status monitoring
Manual test tab, optionally lockable for maintenance
Insulation: Basic insulation for coil-contact circuit, Micro disconnection for open contact, Basic for adjacent contact circuits
Operating temperature range: -40°C to +70°C in operation
Processing terminals include screw terminals with torque of 0.5 Nm
Disclaimers
For detailed technical data and approvals, please refer to the datasheet linked above. Technical data of approved types available upon request. Datasheet was not processed, please search the internet for the part number for more details.
NO PROPER USER MANUAL AND ORIGINAL BOX OF THE ELCTRNOICS ARE ALWAYS MISSING YOU ONLY SEND THE COMPONNET IN YOUR CARDBOARD BOX NO ORGINAL MANUAL NO ORGINAL BOX NOTHIING
High-performance Robotic Arm Gripper, Options for ST3215 / CF35-12 Serial Bus Servo, Closed-loop Control, Real-time Protection, Adjustable Gripper Stand-off
{"id":10020444242237,"title":"1-1415075-1","handle":"1-1415075-1","description":"\u003ch3\u003eTE CONNECTIVITY\/AMP BRAND PT3S7LB2 Relay\u003c\/h3\u003e\n\u003cp\u003ePart Number: 1-1415075-1\u003cbr\u003e\nManufacturer: TE CONNECTIVITY\/AMP BRAND\u003cbr\u003e\nCountry of Origin: AT\u003cbr\u003e\nUnit of Measure: EA\u003cbr\u003e\nECCN: EAR99\u003cbr\u003e\nPackage Type: BLK\u003cbr\u003e\nDatasheet: \u003ca href=\"https:\/\/www.te.com\/commerce\/DocumentDelivery\/DDEController?Action=srchrtrv\u0026amp;DocNm=PT_Package\u0026amp;DocType=Data+Sheet\u0026amp;DocLang=English\u0026amp;PartCntxt=1-1415075-1\u0026amp;DocFormat=pdf\" target=\"_blank\"\u003eView Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eRelays packaged with PT relay, DIN-rail socket, plastic retaining clip, module, and marking tag for easy installation and field repairs\u003c\/li\u003e\n \u003cli\u003eAvailable configurations include 2 pole (12 A), 3 pole (10 A), and 4 pole (6 A)\u003c\/li\u003e\n \u003cli\u003eCoil options for DC and AC voltages\u003c\/li\u003e\n \u003cli\u003eMechanical and electrical indicators for status monitoring\u003c\/li\u003e\n \u003cli\u003eManual test tab, optionally lockable for maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplication Areas\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003ePLC control panels\u003c\/li\u003e\n \u003cli\u003eAutomation panels\u003c\/li\u003e\n \u003cli\u003eMachine industry\u003c\/li\u003e\n \u003cli\u003eElevator industry\u003c\/li\u003e\n \u003cli\u003eBuilding management systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctr\u003e\n \u003cth\u003eContact Data\u003c\/th\u003e\n \u003cth\u003eCol2\u003c\/th\u003e\n \u003cth\u003eCol3\u003c\/th\u003e\n \u003cth\u003eCol4\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n \u003ctd\u003eContact configuration\u003c\/td\u003e\n \u003ctd\u003e2 CO\u003c\/td\u003e\n \u003ctd\u003e3 CO\u003c\/td\u003e\n \u003ctd\u003e4 CO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n \u003ctd\u003eContact set\u003c\/td\u003e\n \u003ctd\u003eSingle contact\u003c\/td\u003e\n \u003ctd\u003e\u003c\/td\u003e\n \u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n \u003ctd\u003eRated voltage \/ Max. switching voltage AC\u003c\/td\u003e\n \u003ctd\u003e240\/400VAC\u003c\/td\u003e\n \u003ctd\u003e240\/400VAC\u003c\/td\u003e\n \u003ctd\u003e240\/240VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n \u003ctd\u003eRated current\u003c\/td\u003e\n \u003ctd\u003e12 A\u003c\/td\u003e\n \u003ctd\u003e10 A\u003c\/td\u003e\n \u003ctd\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n \u003ctd\u003eMaximum breaking capacity AC\u003c\/td\u003e\n \u003ctd\u003e3000 VA\u003c\/td\u003e\n \u003ctd\u003e2500 VA\u003c\/td\u003e\n \u003ctd\u003e1500 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n \u003ctd\u003eContact material\u003c\/td\u003e\n \u003ctd\u003eAgNi90\/10, gold plated\u003c\/td\u003e\n \u003ctd\u003e\u003c\/td\u003e\n \u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCoil Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctr\u003e\n \u003cth\u003eRated coil voltage range\u003c\/th\u003e\n \u003cth\u003eDC coil\u003c\/th\u003e\n \u003cth\u003eAC coil\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n \u003ctd\u003e6...220 VDC\u003c\/td\u003e\n \u003ctd\u003e\u003c\/td\u003e\n \u003ctd\u003e6...230 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCoil Versions\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctr\u003e\n \u003cth\u003eCoil code LED\u003c\/th\u003e\n \u003cth\u003eRated voltage VAC\u003c\/th\u003e\n \u003cth\u003eOperate voltage VAC\u003c\/th\u003e\n \u003cth\u003eRelease voltage VAC\u003c\/th\u003e\n \u003cth\u003eCoil resistance Ω\u003c\/th\u003e\n \u003cth\u003eRated coil power VA\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n \u003ctd\u003eRC4\u003c\/td\u003e\n \u003ctd\u003e24\u003c\/td\u003e\n \u003ctd\u003e19.2\/21.6\u003c\/td\u003e\n \u003ctd\u003e7.2\u003c\/td\u003e\n \u003ctd\u003e192±10%\u003c\/td\u003e\n \u003ctd\u003e1.0\/0.79\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n \u003ctd\u003eSB5\u003c\/td\u003e\n \u003ctd\u003e115\u003c\/td\u003e\n \u003ctd\u003e92.0\/103.5\u003c\/td\u003e\n \u003ctd\u003e34.5\u003c\/td\u003e\n \u003ctd\u003e4845±12%\u003c\/td\u003e\n \u003ctd\u003e1.0\/0.86\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n \u003ctd\u003eTD0\u003c\/td\u003e\n \u003ctd\u003e230\u003c\/td\u003e\n \u003ctd\u003e184.0\/207.0\u003c\/td\u003e\n \u003ctd\u003e69.0\u003c\/td\u003e\n \u003ctd\u003e19465±15%\u003c\/td\u003e\n \u003ctd\u003e1.0\/0.90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eAdditional Details\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eDielectric strength: Coil-contact circuit 2500 Vrms, Open contact circuit 1200 Vrms, Adjacent contact circuits 2500 Vrms\u003c\/li\u003e\n \u003cli\u003eInsulation: Basic insulation for coil-contact circuit, Micro disconnection for open contact, Basic for adjacent contact circuits\u003c\/li\u003e\n \u003cli\u003eOperating temperature range: -40°C to +70°C in operation\u003c\/li\u003e\n \u003cli\u003eProcessing terminals include screw terminals with torque of 0.5 Nm\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDisclaimers\u003c\/h3\u003e\n\u003cp\u003eFor detailed technical data and approvals, please refer to the datasheet linked above. Technical data of approved types available upon request. Datasheet was not processed, please search the internet for the part number for more details.\u003c\/p\u003e","published_at":"2025-08-12T01:55:56+05:30","created_at":"2025-08-12T01:55:56+05:30","vendor":"Waldom Electonics","type":"Relays","tags":["IMPORT_CSV","WLDM"],"price":361030,"price_min":361030,"price_max":361030,"available":false,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50609998364989,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"1-1415075-1","requires_shipping":true,"taxable":true,"featured_image":null,"available":false,"name":"1-1415075-1","public_title":null,"options":["Default Title"],"price":361030,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"1-1415075-1","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/27990952.jpg?v=1754943959"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/27990952.jpg?v=1754943959","options":["Title"],"media":[{"alt":null,"id":45789356622141,"position":1,"preview_image":{"aspect_ratio":1.0,"height":400,"width":400,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/27990952.jpg?v=1754943959"},"aspect_ratio":1.0,"height":400,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/27990952.jpg?v=1754943959","width":400}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eTE CONNECTIVITY\/AMP BRAND PT3S7LB2 Relay\u003c\/h3\u003e\n\u003cp\u003ePart Number: 1-1415075-1\u003cbr\u003e\nManufacturer: TE CONNECTIVITY\/AMP BRAND\u003cbr\u003e\nCountry of Origin: AT\u003cbr\u003e\nUnit of Measure: EA\u003cbr\u003e\nECCN: EAR99\u003cbr\u003e\nPackage Type: BLK\u003cbr\u003e\nDatasheet: \u003ca href=\"https:\/\/www.te.com\/commerce\/DocumentDelivery\/DDEController?Action=srchrtrv\u0026amp;DocNm=PT_Package\u0026amp;DocType=Data+Sheet\u0026amp;DocLang=English\u0026amp;PartCntxt=1-1415075-1\u0026amp;DocFormat=pdf\" target=\"_blank\"\u003eView Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eRelays packaged with PT relay, DIN-rail socket, plastic retaining clip, module, and marking tag for easy installation and field repairs\u003c\/li\u003e\n \u003cli\u003eAvailable configurations include 2 pole (12 A), 3 pole (10 A), and 4 pole (6 A)\u003c\/li\u003e\n \u003cli\u003eCoil options for DC and AC voltages\u003c\/li\u003e\n \u003cli\u003eMechanical and electrical indicators for status monitoring\u003c\/li\u003e\n \u003cli\u003eManual test tab, optionally lockable for maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplication Areas\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003ePLC control panels\u003c\/li\u003e\n \u003cli\u003eAutomation panels\u003c\/li\u003e\n \u003cli\u003eMachine industry\u003c\/li\u003e\n \u003cli\u003eElevator industry\u003c\/li\u003e\n \u003cli\u003eBuilding management systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctr\u003e\n \u003cth\u003eContact Data\u003c\/th\u003e\n \u003cth\u003eCol2\u003c\/th\u003e\n \u003cth\u003eCol3\u003c\/th\u003e\n \u003cth\u003eCol4\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n \u003ctd\u003eContact configuration\u003c\/td\u003e\n \u003ctd\u003e2 CO\u003c\/td\u003e\n \u003ctd\u003e3 CO\u003c\/td\u003e\n \u003ctd\u003e4 CO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n \u003ctd\u003eContact set\u003c\/td\u003e\n \u003ctd\u003eSingle contact\u003c\/td\u003e\n \u003ctd\u003e\u003c\/td\u003e\n \u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n \u003ctd\u003eRated voltage \/ Max. switching voltage AC\u003c\/td\u003e\n \u003ctd\u003e240\/400VAC\u003c\/td\u003e\n \u003ctd\u003e240\/400VAC\u003c\/td\u003e\n \u003ctd\u003e240\/240VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n \u003ctd\u003eRated current\u003c\/td\u003e\n \u003ctd\u003e12 A\u003c\/td\u003e\n \u003ctd\u003e10 A\u003c\/td\u003e\n \u003ctd\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n \u003ctd\u003eMaximum breaking capacity AC\u003c\/td\u003e\n \u003ctd\u003e3000 VA\u003c\/td\u003e\n \u003ctd\u003e2500 VA\u003c\/td\u003e\n \u003ctd\u003e1500 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n \u003ctd\u003eContact material\u003c\/td\u003e\n \u003ctd\u003eAgNi90\/10, gold plated\u003c\/td\u003e\n \u003ctd\u003e\u003c\/td\u003e\n \u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCoil Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctr\u003e\n \u003cth\u003eRated coil voltage range\u003c\/th\u003e\n \u003cth\u003eDC coil\u003c\/th\u003e\n \u003cth\u003eAC coil\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n \u003ctd\u003e6...220 VDC\u003c\/td\u003e\n \u003ctd\u003e\u003c\/td\u003e\n \u003ctd\u003e6...230 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCoil Versions\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctr\u003e\n \u003cth\u003eCoil code LED\u003c\/th\u003e\n \u003cth\u003eRated voltage VAC\u003c\/th\u003e\n \u003cth\u003eOperate voltage VAC\u003c\/th\u003e\n \u003cth\u003eRelease voltage VAC\u003c\/th\u003e\n \u003cth\u003eCoil resistance Ω\u003c\/th\u003e\n \u003cth\u003eRated coil power VA\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n \u003ctd\u003eRC4\u003c\/td\u003e\n \u003ctd\u003e24\u003c\/td\u003e\n \u003ctd\u003e19.2\/21.6\u003c\/td\u003e\n \u003ctd\u003e7.2\u003c\/td\u003e\n \u003ctd\u003e192±10%\u003c\/td\u003e\n \u003ctd\u003e1.0\/0.79\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n \u003ctd\u003eSB5\u003c\/td\u003e\n \u003ctd\u003e115\u003c\/td\u003e\n \u003ctd\u003e92.0\/103.5\u003c\/td\u003e\n \u003ctd\u003e34.5\u003c\/td\u003e\n \u003ctd\u003e4845±12%\u003c\/td\u003e\n \u003ctd\u003e1.0\/0.86\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n \u003ctd\u003eTD0\u003c\/td\u003e\n \u003ctd\u003e230\u003c\/td\u003e\n \u003ctd\u003e184.0\/207.0\u003c\/td\u003e\n \u003ctd\u003e69.0\u003c\/td\u003e\n \u003ctd\u003e19465±15%\u003c\/td\u003e\n \u003ctd\u003e1.0\/0.90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eAdditional Details\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eDielectric strength: Coil-contact circuit 2500 Vrms, Open contact circuit 1200 Vrms, Adjacent contact circuits 2500 Vrms\u003c\/li\u003e\n \u003cli\u003eInsulation: Basic insulation for coil-contact circuit, Micro disconnection for open contact, Basic for adjacent contact circuits\u003c\/li\u003e\n \u003cli\u003eOperating temperature range: -40°C to +70°C in operation\u003c\/li\u003e\n \u003cli\u003eProcessing terminals include screw terminals with torque of 0.5 Nm\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDisclaimers\u003c\/h3\u003e\n\u003cp\u003eFor detailed technical data and approvals, please refer to the datasheet linked above. Technical data of approved types available upon request. Datasheet was not processed, please search the internet for the part number for more details.\u003c\/p\u003e"}