Enhance your electronic protection with the EPCOS Gas Discharge Tubes (GDTs) / Gas Plasma Arrestors, designed for reliable surge suppression in various applications. Manufactured in Malaysia, these high-performance arrestors are RoHS-compatible and meet industry standards for safety and durability.
{"id":10022959153469,"title":"B88069X8740B502","handle":"b88069x8740b502","description":"\u003ch3\u003eGas Discharge Tubes - GDTs \/ Gas Plasma Arrestors\u003c\/h3\u003e\n\u003cp\u003eEnhance your electronic protection with the EPCOS Gas Discharge Tubes (GDTs) \/ Gas Plasma Arrestors, designed for reliable surge suppression in various applications. Manufactured in Malaysia, these high-performance arrestors are RoHS-compatible and meet industry standards for safety and durability.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e B88069X8740B502\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e EPCOS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e MY\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit of Measure:\u003c\/strong\u003e EA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e EAR99\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Type:\u003c\/strong\u003e BLK\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDatasheet:\u003c\/strong\u003e \u003ca href=\"https:\/\/product.tdk.com\/system\/files\/dam\/doc\/product\/protection\/voltage\/arrester\/data_sheet\/100\/ds\/t23-a230x-x8740b502.pdf?ref_disty=mouser\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDownload Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStandard size for easy integration\u003c\/li\u003e\n\u003cli\u003eFast response time for effective surge suppression\u003c\/li\u003e\n\u003cli\u003eVery high current rating ensures robust protection\u003c\/li\u003e\n\u003cli\u003eStable performance over the component's lifespan\u003c\/li\u003e\n\u003cli\u003eLow capacitance (\u0026lt; 1.5 pF) minimizes signal interference\u003c\/li\u003e\n\u003cli\u003eHigh insulation resistance (\u0026gt; 10 GΩ at 100 V DC)\u003c\/li\u003e\n\u003cli\u003eRoHS-compatible for environmentally conscious designs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValues\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Spark-over Voltage (Min.\/Max.)\u003c\/td\u003e\n\u003ctd\u003e230 ±20 V (Min. 184 V, Max. 276 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpulse Spark-over Voltage at 100 V\/µs\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 400 V (typical \u0026lt; 350 V); \u0026lt; 500 V (distribution \u0026lt; 450 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Life\u003c\/td\u003e\n\u003ctd\u003e10 operations at 50 Hz; 1 s; 50 operations at specified conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance at 100 V DC\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance at 1 MHz\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1.5 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransverse Delay Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.2 µs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArc Voltage at 1 A\u003c\/td\u003e\n\u003ctd\u003e~ 35 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlow Voltage\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e~ 2 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation \u0026amp; Storage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +125°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClimatic Category (IEC 60068-1)\u003c\/td\u003e\n\u003ctd\u003e40\/125\/21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplication Areas\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLine Protection\u003c\/li\u003e\n\u003cli\u003eStation Protection\u003c\/li\u003e\n\u003cli\u003eBase Stations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSoldering Parameters\u003c\/h3\u003e\n\u003cp\u003eWave Soldering:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSolder Composition: Sn 95.5 \/ Ag 3.8 \/ Cu 0.7\u003c\/li\u003e\n\u003cli\u003eSolder Bath Temperature: 263°C (±3°C)\u003c\/li\u003e\n\u003cli\u003eDwell Time: \u0026lt; 3 seconds\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eImportant Cautions and Handling Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOperate surge arresters within specified maximum operating voltages.\u003c\/li\u003e\n\u003cli\u003eAvoid operation in power networks exceeding spark-over voltage.\u003c\/li\u003e\n\u003cli\u003eHandle with care to prevent damage; do not drop the components.\u003c\/li\u003e\n\u003cli\u003eDo not use damaged surge arresters.\u003c\/li\u003e\n\u003cli\u003eSurge arresters may become hot under prolonged current stress.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor more detailed information, please refer to the \u003ca href=\"https:\/\/product.tdk.com\/system\/files\/dam\/doc\/product\/protection\/voltage\/arrester\/data_sheet\/100\/ds\/t23-a230x-x8740b502.pdf?ref_disty=mouser\" target=\"_blank\" rel=\"noopener noreferrer\"\u003efull datasheet\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Datasheet was not processed; please search the internet for the part number \u003cem\u003eB88069X8740B502\u003c\/em\u003e for more details.\u003c\/p\u003e","published_at":"2025-08-13T16:07:24+05:30","created_at":"2025-08-13T16:07:24+05:30","vendor":"Waldom Electonics","type":"","tags":["EPCOS","IMPORT_CSV","WLDM"],"price":34232,"price_min":34232,"price_max":34232,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50615550312765,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"B88069X8740B502","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"B88069X8740B502","public_title":null,"options":["Default Title"],"price":34232,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"B88069X8740B502","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/56958018.jpg?v=1755081446"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/56958018.jpg?v=1755081446","options":["Title"],"media":[{"alt":null,"id":45818168443197,"position":1,"preview_image":{"aspect_ratio":1.0,"height":420,"width":420,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/56958018.jpg?v=1755081446"},"aspect_ratio":1.0,"height":420,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/56958018.jpg?v=1755081446","width":420}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eGas Discharge Tubes - GDTs \/ Gas Plasma Arrestors\u003c\/h3\u003e\n\u003cp\u003eEnhance your electronic protection with the EPCOS Gas Discharge Tubes (GDTs) \/ Gas Plasma Arrestors, designed for reliable surge suppression in various applications. Manufactured in Malaysia, these high-performance arrestors are RoHS-compatible and meet industry standards for safety and durability.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e B88069X8740B502\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e EPCOS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e MY\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit of Measure:\u003c\/strong\u003e EA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e EAR99\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Type:\u003c\/strong\u003e BLK\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDatasheet:\u003c\/strong\u003e \u003ca href=\"https:\/\/product.tdk.com\/system\/files\/dam\/doc\/product\/protection\/voltage\/arrester\/data_sheet\/100\/ds\/t23-a230x-x8740b502.pdf?ref_disty=mouser\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDownload Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStandard size for easy integration\u003c\/li\u003e\n\u003cli\u003eFast response time for effective surge suppression\u003c\/li\u003e\n\u003cli\u003eVery high current rating ensures robust protection\u003c\/li\u003e\n\u003cli\u003eStable performance over the component's lifespan\u003c\/li\u003e\n\u003cli\u003eLow capacitance (\u0026lt; 1.5 pF) minimizes signal interference\u003c\/li\u003e\n\u003cli\u003eHigh insulation resistance (\u0026gt; 10 GΩ at 100 V DC)\u003c\/li\u003e\n\u003cli\u003eRoHS-compatible for environmentally conscious designs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValues\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Spark-over Voltage (Min.\/Max.)\u003c\/td\u003e\n\u003ctd\u003e230 ±20 V (Min. 184 V, Max. 276 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpulse Spark-over Voltage at 100 V\/µs\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 400 V (typical \u0026lt; 350 V); \u0026lt; 500 V (distribution \u0026lt; 450 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Life\u003c\/td\u003e\n\u003ctd\u003e10 operations at 50 Hz; 1 s; 50 operations at specified conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance at 100 V DC\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance at 1 MHz\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1.5 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransverse Delay Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.2 µs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArc Voltage at 1 A\u003c\/td\u003e\n\u003ctd\u003e~ 35 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlow Voltage\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e~ 2 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation \u0026amp; Storage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +125°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClimatic Category (IEC 60068-1)\u003c\/td\u003e\n\u003ctd\u003e40\/125\/21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplication Areas\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLine Protection\u003c\/li\u003e\n\u003cli\u003eStation Protection\u003c\/li\u003e\n\u003cli\u003eBase Stations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSoldering Parameters\u003c\/h3\u003e\n\u003cp\u003eWave Soldering:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSolder Composition: Sn 95.5 \/ Ag 3.8 \/ Cu 0.7\u003c\/li\u003e\n\u003cli\u003eSolder Bath Temperature: 263°C (±3°C)\u003c\/li\u003e\n\u003cli\u003eDwell Time: \u0026lt; 3 seconds\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eImportant Cautions and Handling Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOperate surge arresters within specified maximum operating voltages.\u003c\/li\u003e\n\u003cli\u003eAvoid operation in power networks exceeding spark-over voltage.\u003c\/li\u003e\n\u003cli\u003eHandle with care to prevent damage; do not drop the components.\u003c\/li\u003e\n\u003cli\u003eDo not use damaged surge arresters.\u003c\/li\u003e\n\u003cli\u003eSurge arresters may become hot under prolonged current stress.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor more detailed information, please refer to the \u003ca href=\"https:\/\/product.tdk.com\/system\/files\/dam\/doc\/product\/protection\/voltage\/arrester\/data_sheet\/100\/ds\/t23-a230x-x8740b502.pdf?ref_disty=mouser\" target=\"_blank\" rel=\"noopener noreferrer\"\u003efull datasheet\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Datasheet was not processed; please search the internet for the part number \u003cem\u003eB88069X8740B502\u003c\/em\u003e for more details.\u003c\/p\u003e"}