The HONEYWELL AWM3300V is a high-precision flow sensor designed for accurate measurement of airflow up to 1.0 SLPM (Standard Liters Per Minute) and 1000 sccm (standard cubic centimeters per minute). This sensor features a microbridge mass airflow design with amplified output, making it suitable for applications requiring reliable and sensitive airflow detection.
{"id":10026849599805,"title":"AWM3300V","handle":"awm3300v","description":"\u003ch3\u003eHONEYWELL AWM3300V Flow Sensor 1.0 SLPM Straight 1000 sccm\u003c\/h3\u003e\n\u003cp\u003eThe HONEYWELL AWM3300V is a high-precision flow sensor designed for accurate measurement of airflow up to 1.0 SLPM (Standard Liters Per Minute) and 1000 sccm (standard cubic centimeters per minute). This sensor features a microbridge mass airflow design with amplified output, making it suitable for applications requiring reliable and sensitive airflow detection.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e AWM3300V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e HONEYWELL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin (COO):\u003c\/strong\u003e CN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit of Measure (UOM):\u003c\/strong\u003e EA (Each)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e EAR99\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Type:\u003c\/strong\u003e PCS (Pack of one)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliant:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Sensors\/Transducers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Category:\u003c\/strong\u003e Sensors\/Transducers | Flow Sensors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFlow sensing capability up to 1.0 SLPM (1000 sccm)\u003c\/li\u003e\n\u003cli\u003eLaser trimmed for improved sensor interchangeability\u003c\/li\u003e\n\u003cli\u003eLow differential pressure sensing\u003c\/li\u003e\n\u003cli\u003eAmplified output with onboard circuitry for increased gain and voltage offset adjustment\u003c\/li\u003e\n\u003cli\u003eHeater control and sensing bridge supply circuits integrated within the package\u003c\/li\u003e\n\u003cli\u003eRatiometric output voltage relative to supply voltage\u003c\/li\u003e\n\u003cli\u003eSuitable for precise airflow measurement in various industrial and medical applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctr\u003e\n\u003cth\u003ePerformance Parameter\u003c\/th\u003e\n\u003cth\u003eConditions \/ Notes\u003c\/th\u003e\n\u003cth\u003eValues\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Range\u003c\/td\u003e\n\u003ctd\u003eUp to 1.0 SLPM \/ 1000 sccm\u003c\/td\u003e\n\u003ctd\u003e1.0 SLPM \/ 1000 sccm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e10.01 ± 0.01 VDC @ 25°C\u003c\/td\u003e\n\u003ctd\u003e5 VDC typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C to +85°C\u003c\/td\u003e\n\u003ctd\u003e-25°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +90°C\u003c\/td\u003e\n\u003ctd\u003e-40°C to +90°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarm-up Time\u003c\/td\u003e\n\u003ctd\u003eMaximum 1 minute for circuitry stabilization\u003c\/td\u003e\n\u003ctd\u003eMax 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Flow Rate Change\u003c\/td\u003e\n\u003ctd\u003eTo prevent damage\u003c\/td\u003e\n\u003ctd\u003e5 SLPM\/sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMounting \u0026amp; Handling\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePositive flow direction from Port 1 (P1) to Port 2 (P2)\u003c\/li\u003e\n\u003cli\u003eDo not exert forces exceeding 4.54 kg (10 lbs.) in any direction\u003c\/li\u003e\n\u003cli\u003eMounting dimensions are provided for reference only\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrder Guide \u0026amp; Performance Curves\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eFlow Range (sccm)\u003c\/th\u003e\n\u003cth\u003ePressure (mBar)\u003c\/th\u003e\n\u003cth\u003eOutput Voltage (VDC)\u003c\/th\u003e\n\u003cth\u003eTolerance (VDC)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAWM3300V\u003c\/td\u003e\n\u003ctd\u003e0 - 1000\u003c\/td\u003e\n\u003ctd\u003e± 0.15\u003c\/td\u003e\n\u003ctd\u003e5.00\u003c\/td\u003e\n\u003ctd\u003e± 0.15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAdditional Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRoHS Compliant\u003c\/li\u003e\n\u003cli\u003eIncludes integrated heater control and sensing circuitry for enhanced performance\u003c\/li\u003e\n\u003cli\u003eDesigned for easy interchangeability and calibration stability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor detailed specifications and application notes, please refer to the \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-mr\/mr-awm3300v.pdf\" target=\"_blank\"\u003eDatasheet\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e The datasheet was not processed; please search the internet for the part number AWM3300V for more details.\u003c\/p\u003e\u003cbr\u003e","published_at":"2025-08-15T16:49:50+05:30","created_at":"2025-08-15T16:49:51+05:30","vendor":"Waldom Electonics","type":"Sensors\/Transducers","tags":["Flow","HWLL","IMPORT_CSV","IMPORT_PT2","Sensors","SLPM","Transducers","WLDM"],"price":2359096,"price_min":2359096,"price_max":2359096,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50623229264189,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"AWM3300V","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"AWM3300V","public_title":null,"options":["Default Title"],"price":2359096,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"AWM3300V","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/11928759.jpg?v=1755256791"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/11928759.jpg?v=1755256791","options":["Title"],"media":[{"alt":null,"id":45853022552381,"position":1,"preview_image":{"aspect_ratio":1.0,"height":640,"width":640,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/11928759.jpg?v=1755256791"},"aspect_ratio":1.0,"height":640,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/11928759.jpg?v=1755256791","width":640}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eHONEYWELL AWM3300V Flow Sensor 1.0 SLPM Straight 1000 sccm\u003c\/h3\u003e\n\u003cp\u003eThe HONEYWELL AWM3300V is a high-precision flow sensor designed for accurate measurement of airflow up to 1.0 SLPM (Standard Liters Per Minute) and 1000 sccm (standard cubic centimeters per minute). This sensor features a microbridge mass airflow design with amplified output, making it suitable for applications requiring reliable and sensitive airflow detection.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e AWM3300V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e HONEYWELL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin (COO):\u003c\/strong\u003e CN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit of Measure (UOM):\u003c\/strong\u003e EA (Each)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e EAR99\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Type:\u003c\/strong\u003e PCS (Pack of one)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliant:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Sensors\/Transducers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Category:\u003c\/strong\u003e Sensors\/Transducers | Flow Sensors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFlow sensing capability up to 1.0 SLPM (1000 sccm)\u003c\/li\u003e\n\u003cli\u003eLaser trimmed for improved sensor interchangeability\u003c\/li\u003e\n\u003cli\u003eLow differential pressure sensing\u003c\/li\u003e\n\u003cli\u003eAmplified output with onboard circuitry for increased gain and voltage offset adjustment\u003c\/li\u003e\n\u003cli\u003eHeater control and sensing bridge supply circuits integrated within the package\u003c\/li\u003e\n\u003cli\u003eRatiometric output voltage relative to supply voltage\u003c\/li\u003e\n\u003cli\u003eSuitable for precise airflow measurement in various industrial and medical applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctr\u003e\n\u003cth\u003ePerformance Parameter\u003c\/th\u003e\n\u003cth\u003eConditions \/ Notes\u003c\/th\u003e\n\u003cth\u003eValues\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Range\u003c\/td\u003e\n\u003ctd\u003eUp to 1.0 SLPM \/ 1000 sccm\u003c\/td\u003e\n\u003ctd\u003e1.0 SLPM \/ 1000 sccm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e10.01 ± 0.01 VDC @ 25°C\u003c\/td\u003e\n\u003ctd\u003e5 VDC typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C to +85°C\u003c\/td\u003e\n\u003ctd\u003e-25°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +90°C\u003c\/td\u003e\n\u003ctd\u003e-40°C to +90°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarm-up Time\u003c\/td\u003e\n\u003ctd\u003eMaximum 1 minute for circuitry stabilization\u003c\/td\u003e\n\u003ctd\u003eMax 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Flow Rate Change\u003c\/td\u003e\n\u003ctd\u003eTo prevent damage\u003c\/td\u003e\n\u003ctd\u003e5 SLPM\/sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMounting \u0026amp; Handling\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePositive flow direction from Port 1 (P1) to Port 2 (P2)\u003c\/li\u003e\n\u003cli\u003eDo not exert forces exceeding 4.54 kg (10 lbs.) in any direction\u003c\/li\u003e\n\u003cli\u003eMounting dimensions are provided for reference only\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrder Guide \u0026amp; Performance Curves\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eFlow Range (sccm)\u003c\/th\u003e\n\u003cth\u003ePressure (mBar)\u003c\/th\u003e\n\u003cth\u003eOutput Voltage (VDC)\u003c\/th\u003e\n\u003cth\u003eTolerance (VDC)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAWM3300V\u003c\/td\u003e\n\u003ctd\u003e0 - 1000\u003c\/td\u003e\n\u003ctd\u003e± 0.15\u003c\/td\u003e\n\u003ctd\u003e5.00\u003c\/td\u003e\n\u003ctd\u003e± 0.15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAdditional Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRoHS Compliant\u003c\/li\u003e\n\u003cli\u003eIncludes integrated heater control and sensing circuitry for enhanced performance\u003c\/li\u003e\n\u003cli\u003eDesigned for easy interchangeability and calibration stability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor detailed specifications and application notes, please refer to the \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-mr\/mr-awm3300v.pdf\" target=\"_blank\"\u003eDatasheet\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e The datasheet was not processed; please search the internet for the part number AWM3300V for more details.\u003c\/p\u003e\u003cbr\u003e"}