OMRON ELECTRONIC COMPONENTS G7L-2A-TUB-J-CB-DC12 Power Relay
Part Number: G7L-2A-TUB-J-CB-DC12
Manufacturer: OMRON ELECTRONIC COMPONENTS
Country of Origin: Indonesia (ID)
Unit of Measure: Not specified
ECCN: EAR99
Package Type: Not specified
Datasheet: G7L Power Relay Datasheet
The G7L-2A-TUB-J-CB-DC12 is a high-capacity, high-dielectric-strength relay designed for reliable switching in various electronic applications. It features a wide-range AC-activated coil compatible with 100 to 120 VAC at 50/60 Hz and 200 to 240 VAC at 50/60 Hz, making it suitable for diverse power control tasks.
Key Features
High-capacity relay with robust dielectric strength
No contact chattering during momentary voltage drops up to 50% of rated voltage
Wide-range AC coil handling 100-120 VAC and 200-240 VAC at 50/60 Hz
Miniature size optimized for maximum switching power, especially for inductive loads
Dimensions vary based on mounting type. E-brackets, adapters, and sockets are sold separately. For detailed dimensions, refer to the datasheet.
Additional Information
RoHS compliant
Part Number: G7L-2A-TUB-J-CB-DC12
For detailed specifications and application examples, please consult the datasheet.
Note: This product is suitable for switching applications in power supplies, motor controls, lighting, and other industrial equipment. Accessories such as E-brackets, adapters, and covers are sold separately.
Note: The product image displayed is a standard reference image. Actual product appearance may vary. For the most accurate and up-to-date representation, we recommend searching the part number online.
{"id":10008988254525,"title":"G7L-2A-TUB-J-CB-DC12","handle":"g7l-2a-tub-j-cb-dc12","description":"\u003ch3\u003eOMRON ELECTRONIC COMPONENTS G7L-2A-TUB-J-CB-DC12 Power Relay\u003c\/h3\u003e\n\u003cp\u003ePart Number: G7L-2A-TUB-J-CB-DC12\u003cbr\u003e\nManufacturer: OMRON ELECTRONIC COMPONENTS\u003cbr\u003e\nCountry of Origin: Indonesia (ID)\u003cbr\u003e\nUnit of Measure: Not specified\u003cbr\u003e\nECCN: EAR99\u003cbr\u003e\nPackage Type: Not specified\u003cbr\u003e\nDatasheet: \u003ca href=\"https:\/\/omronfs.omron.com\/en_US\/ecb\/products\/pdf\/en-g7l.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eG7L Power Relay Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eThe G7L-2A-TUB-J-CB-DC12 is a high-capacity, high-dielectric-strength relay designed for reliable switching in various electronic applications. It features a wide-range AC-activated coil compatible with 100 to 120 VAC at 50\/60 Hz and 200 to 240 VAC at 50\/60 Hz, making it suitable for diverse power control tasks.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-capacity relay with robust dielectric strength\u003c\/li\u003e\n\u003cli\u003eNo contact chattering during momentary voltage drops up to 50% of rated voltage\u003c\/li\u003e\n\u003cli\u003eWide-range AC coil handling 100-120 VAC and 200-240 VAC at 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eMiniature size optimized for maximum switching power, especially for inductive loads\u003c\/li\u003e\n\u003cli\u003eFlame-resistant insulation materials (UL94V-0 compliant)\u003c\/li\u003e\n\u003cli\u003eMultiple terminal options including quick-connect, screw, and PCB terminals\u003c\/li\u003e\n\u003cli\u003eMounting options include DIN track, upper bracket, and E-bracket (sold separately)\u003c\/li\u003e\n\u003cli\u003eConforms to UL, CSA, TUV standards and IEC950 compliance\u003c\/li\u003e\n\u003cli\u003eContact gap of 3 mm for safety\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Ratings \u0026amp; Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eCoil Voltage\u003c\/th\u003e\n\u003cth\u003eRated Current (mA)\u003c\/th\u003e\n\u003cth\u003eCoil Resistance (Ω)\u003c\/th\u003e\n\u003cth\u003eMust Operate Voltage\u003c\/th\u003e\n\u003cth\u003eMust Release Voltage\u003c\/th\u003e\n\u003cth\u003eMax Permissible Voltage\u003c\/th\u003e\n\u003cth\u003ePower Consumption (VA-W)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC 12V\u003c\/td\u003e\n\u003ctd\u003e158\u003c\/td\u003e\n\u003ctd\u003e75\u003c\/td\u003e\n\u003ctd\u003e75% max.\u003c\/td\u003e\n\u003ctd\u003e15% min.\u003c\/td\u003e\n\u003ctd\u003e132 V\u003c\/td\u003e\n\u003ctd\u003eApprox. 1.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC 12V\u003c\/td\u003e\n\u003ctd\u003e142\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003ctd\u003e75% max.\u003c\/td\u003e\n\u003ctd\u003e15% min.\u003c\/td\u003e\n\u003ctd\u003e110% of rated voltage\u003c\/td\u003e\n\u003ctd\u003eApprox. 1.7 to 2.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC 24V\u003c\/td\u003e\n\u003ctd\u003e71\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003ctd\u003e75% max.\u003c\/td\u003e\n\u003ctd\u003e15% min.\u003c\/td\u003e\n\u003ctd\u003e110% of rated voltage\u003c\/td\u003e\n\u003ctd\u003eApprox. 1.7 to 2.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC 100\/120V\u003c\/td\u003e\n\u003ctd\u003e17.0 to 20.4\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003ctd\u003e75% max.\u003c\/td\u003e\n\u003ctd\u003e18 V min.\u003c\/td\u003e\n\u003ctd\u003e132 V\u003c\/td\u003e\n\u003ctd\u003eApprox. 1.7 to 2.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC 200\/240V\u003c\/td\u003e\n\u003ctd\u003e8.5 to 10.2\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003ctd\u003e75% max.\u003c\/td\u003e\n\u003ctd\u003e36 V min.\u003c\/td\u003e\n\u003ctd\u003e264 V\u003c\/td\u003e\n\u003ctd\u003eApprox. 1.7 to 2.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eContact Ratings\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eContact Form\u003c\/th\u003e\n\u003cth\u003eLoad Type\u003c\/th\u003e\n\u003cth\u003eResistive Load\u003c\/th\u003e\n\u003cth\u003eInductive Load (cos φ=0.4)\u003c\/th\u003e\n\u003cth\u003eRated Load\u003c\/th\u003e\n\u003cth\u003eRated Carry Current\u003c\/th\u003e\n\u003cth\u003eMax Switching Voltage\u003c\/th\u003e\n\u003cth\u003eMax Switching Current\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDPST-NO\u003c\/td\u003e\n\u003ctd\u003eResistive \/ Inductive\u003c\/td\u003e\n\u003ctd\u003e30 A at 220 VAC\u003c\/td\u003e\n\u003ctd\u003e25 A at 220 VAC\u003c\/td\u003e\n\u003ctd\u003e25 A at 220 VAC\u003c\/td\u003e\n\u003ctd\u003e20 A at 220 VAC\u003c\/td\u003e\n\u003ctd\u003e250 VAC\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical \u0026amp; Electrical Endurance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMechanical endurance: 1,000,000 operations minimum at 1,800 operations\/hr\u003c\/li\u003e\n\u003cli\u003eElectrical endurance: 100,000 operations minimum at rated load\u003c\/li\u003e\n\u003cli\u003eOperate time: Max. 30 ms\u003c\/li\u003e\n\u003cli\u003eRelease time: Max. 30 ms\u003c\/li\u003e\n\u003cli\u003eContact resistance: Max. 50 mΩ\u003c\/li\u003e\n\u003cli\u003eInsulation resistance: Min. 1,000 MΩ at 500 VDC\u003c\/li\u003e\n\u003cli\u003eDielectric strength: 4,000 VAC coil to contacts; 2,000 VAC between contacts\u003c\/li\u003e\n\u003cli\u003eImpulse withstand voltage: 10,000 V\u003c\/li\u003e\n\u003cli\u003eShock resistance: 1,000 m\/s² (destruction), 100 m\/s² (malfunction)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Dimensions \u0026amp; Mounting\u003c\/h3\u003e\n\u003cp\u003eDimensions vary based on mounting type. E-brackets, adapters, and sockets are sold separately. For detailed dimensions, refer to the datasheet.\u003c\/p\u003e\n\u003ch3\u003eAdditional Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003ePart Number: G7L-2A-TUB-J-CB-DC12\u003c\/li\u003e\n\u003cli\u003eFor detailed specifications and application examples, please consult the \u003ca href=\"https:\/\/omronfs.omron.com\/en_US\/ecb\/products\/pdf\/en-g7l.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003edatasheet\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNote: This product is suitable for switching applications in power supplies, motor controls, lighting, and other industrial equipment. Accessories such as E-brackets, adapters, and covers are sold separately.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNote: The product image displayed is a standard reference image. Actual product appearance may vary. For the most accurate and up-to-date representation, we recommend searching the part number online.\u003c\/strong\u003e\u003c\/p\u003e","published_at":"2025-08-08T09:49:45+05:30","created_at":"2025-08-08T09:49:45+05:30","vendor":"Waldom Electonics","type":"","tags":["12VDC","DPST","IMPORT_PT2","OMRON-ELE","STD_IMG","WLDM"],"price":142610,"price_min":142610,"price_max":142610,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50562310340925,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"G7L-2A-TUB-J-CB-DC12","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"G7L-2A-TUB-J-CB-DC12","public_title":null,"options":["Default Title"],"price":142610,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"G7L-2A-TUB-J-CB-DC12","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/fbe811dc-181f-41c1-ab5a-dc3410446d1d_c0eecdab-6e2a-4257-bd96-df0de9c689cd.jpg?v=1754626785"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/fbe811dc-181f-41c1-ab5a-dc3410446d1d_c0eecdab-6e2a-4257-bd96-df0de9c689cd.jpg?v=1754626785","options":["Title"],"media":[{"alt":null,"id":45723555889469,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1024,"width":1024,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/fbe811dc-181f-41c1-ab5a-dc3410446d1d_c0eecdab-6e2a-4257-bd96-df0de9c689cd.jpg?v=1754626785"},"aspect_ratio":1.0,"height":1024,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/fbe811dc-181f-41c1-ab5a-dc3410446d1d_c0eecdab-6e2a-4257-bd96-df0de9c689cd.jpg?v=1754626785","width":1024}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eOMRON ELECTRONIC COMPONENTS G7L-2A-TUB-J-CB-DC12 Power Relay\u003c\/h3\u003e\n\u003cp\u003ePart Number: G7L-2A-TUB-J-CB-DC12\u003cbr\u003e\nManufacturer: OMRON ELECTRONIC COMPONENTS\u003cbr\u003e\nCountry of Origin: Indonesia (ID)\u003cbr\u003e\nUnit of Measure: Not specified\u003cbr\u003e\nECCN: EAR99\u003cbr\u003e\nPackage Type: Not specified\u003cbr\u003e\nDatasheet: \u003ca href=\"https:\/\/omronfs.omron.com\/en_US\/ecb\/products\/pdf\/en-g7l.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eG7L Power Relay Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eThe G7L-2A-TUB-J-CB-DC12 is a high-capacity, high-dielectric-strength relay designed for reliable switching in various electronic applications. It features a wide-range AC-activated coil compatible with 100 to 120 VAC at 50\/60 Hz and 200 to 240 VAC at 50\/60 Hz, making it suitable for diverse power control tasks.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-capacity relay with robust dielectric strength\u003c\/li\u003e\n\u003cli\u003eNo contact chattering during momentary voltage drops up to 50% of rated voltage\u003c\/li\u003e\n\u003cli\u003eWide-range AC coil handling 100-120 VAC and 200-240 VAC at 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eMiniature size optimized for maximum switching power, especially for inductive loads\u003c\/li\u003e\n\u003cli\u003eFlame-resistant insulation materials (UL94V-0 compliant)\u003c\/li\u003e\n\u003cli\u003eMultiple terminal options including quick-connect, screw, and PCB terminals\u003c\/li\u003e\n\u003cli\u003eMounting options include DIN track, upper bracket, and E-bracket (sold separately)\u003c\/li\u003e\n\u003cli\u003eConforms to UL, CSA, TUV standards and IEC950 compliance\u003c\/li\u003e\n\u003cli\u003eContact gap of 3 mm for safety\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Ratings \u0026amp; Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eCoil Voltage\u003c\/th\u003e\n\u003cth\u003eRated Current (mA)\u003c\/th\u003e\n\u003cth\u003eCoil Resistance (Ω)\u003c\/th\u003e\n\u003cth\u003eMust Operate Voltage\u003c\/th\u003e\n\u003cth\u003eMust Release Voltage\u003c\/th\u003e\n\u003cth\u003eMax Permissible Voltage\u003c\/th\u003e\n\u003cth\u003ePower Consumption (VA-W)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC 12V\u003c\/td\u003e\n\u003ctd\u003e158\u003c\/td\u003e\n\u003ctd\u003e75\u003c\/td\u003e\n\u003ctd\u003e75% max.\u003c\/td\u003e\n\u003ctd\u003e15% min.\u003c\/td\u003e\n\u003ctd\u003e132 V\u003c\/td\u003e\n\u003ctd\u003eApprox. 1.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC 12V\u003c\/td\u003e\n\u003ctd\u003e142\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003ctd\u003e75% max.\u003c\/td\u003e\n\u003ctd\u003e15% min.\u003c\/td\u003e\n\u003ctd\u003e110% of rated voltage\u003c\/td\u003e\n\u003ctd\u003eApprox. 1.7 to 2.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC 24V\u003c\/td\u003e\n\u003ctd\u003e71\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003ctd\u003e75% max.\u003c\/td\u003e\n\u003ctd\u003e15% min.\u003c\/td\u003e\n\u003ctd\u003e110% of rated voltage\u003c\/td\u003e\n\u003ctd\u003eApprox. 1.7 to 2.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC 100\/120V\u003c\/td\u003e\n\u003ctd\u003e17.0 to 20.4\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003ctd\u003e75% max.\u003c\/td\u003e\n\u003ctd\u003e18 V min.\u003c\/td\u003e\n\u003ctd\u003e132 V\u003c\/td\u003e\n\u003ctd\u003eApprox. 1.7 to 2.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC 200\/240V\u003c\/td\u003e\n\u003ctd\u003e8.5 to 10.2\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003ctd\u003e75% max.\u003c\/td\u003e\n\u003ctd\u003e36 V min.\u003c\/td\u003e\n\u003ctd\u003e264 V\u003c\/td\u003e\n\u003ctd\u003eApprox. 1.7 to 2.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eContact Ratings\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eContact Form\u003c\/th\u003e\n\u003cth\u003eLoad Type\u003c\/th\u003e\n\u003cth\u003eResistive Load\u003c\/th\u003e\n\u003cth\u003eInductive Load (cos φ=0.4)\u003c\/th\u003e\n\u003cth\u003eRated Load\u003c\/th\u003e\n\u003cth\u003eRated Carry Current\u003c\/th\u003e\n\u003cth\u003eMax Switching Voltage\u003c\/th\u003e\n\u003cth\u003eMax Switching Current\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDPST-NO\u003c\/td\u003e\n\u003ctd\u003eResistive \/ Inductive\u003c\/td\u003e\n\u003ctd\u003e30 A at 220 VAC\u003c\/td\u003e\n\u003ctd\u003e25 A at 220 VAC\u003c\/td\u003e\n\u003ctd\u003e25 A at 220 VAC\u003c\/td\u003e\n\u003ctd\u003e20 A at 220 VAC\u003c\/td\u003e\n\u003ctd\u003e250 VAC\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical \u0026amp; Electrical Endurance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMechanical endurance: 1,000,000 operations minimum at 1,800 operations\/hr\u003c\/li\u003e\n\u003cli\u003eElectrical endurance: 100,000 operations minimum at rated load\u003c\/li\u003e\n\u003cli\u003eOperate time: Max. 30 ms\u003c\/li\u003e\n\u003cli\u003eRelease time: Max. 30 ms\u003c\/li\u003e\n\u003cli\u003eContact resistance: Max. 50 mΩ\u003c\/li\u003e\n\u003cli\u003eInsulation resistance: Min. 1,000 MΩ at 500 VDC\u003c\/li\u003e\n\u003cli\u003eDielectric strength: 4,000 VAC coil to contacts; 2,000 VAC between contacts\u003c\/li\u003e\n\u003cli\u003eImpulse withstand voltage: 10,000 V\u003c\/li\u003e\n\u003cli\u003eShock resistance: 1,000 m\/s² (destruction), 100 m\/s² (malfunction)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Dimensions \u0026amp; Mounting\u003c\/h3\u003e\n\u003cp\u003eDimensions vary based on mounting type. E-brackets, adapters, and sockets are sold separately. For detailed dimensions, refer to the datasheet.\u003c\/p\u003e\n\u003ch3\u003eAdditional Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003ePart Number: G7L-2A-TUB-J-CB-DC12\u003c\/li\u003e\n\u003cli\u003eFor detailed specifications and application examples, please consult the \u003ca href=\"https:\/\/omronfs.omron.com\/en_US\/ecb\/products\/pdf\/en-g7l.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003edatasheet\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNote: This product is suitable for switching applications in power supplies, motor controls, lighting, and other industrial equipment. Accessories such as E-brackets, adapters, and covers are sold separately.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNote: The product image displayed is a standard reference image. Actual product appearance may vary. For the most accurate and up-to-date representation, we recommend searching the part number online.\u003c\/strong\u003e\u003c\/p\u003e"}