OMRON ELECTRONIC COMPONENTS G9EC-1-DC12 DC Power Relay
Introducing the G9EC-1-DC12 DC Power Relay manufactured by OMRON ELECTRONIC COMPONENTS. This high-capacity relay is designed for demanding applications requiring reliable switching of high-voltage and high-current loads.
Includes screw terminals, mounting holes for M6 or 6.5-dia. screws
G9EC-1
Dimensions with lead wires available
Refer to datasheet for detailed mounting and wiring instructions
Application & Usage
This relay is suitable for industrial applications requiring high-current switching, such as power supply systems, motor controls, and high-capacity load management. Ensure proper safety measures and verify equipment compatibility before installation.
Note: Application examples provided are for reference only. Confirm equipment functions and safety before use. Consult your OMRON representative for conditions outside standard specifications.
For more detailed specifications and installation instructions, please refer to the datasheet.
Disclaimer: Application examples are for reference only. Confirm equipment functions and safety before use. Consult your OMRON representative for applications outside standard specifications.
Use left/right arrows to navigate the slideshow or swipe left/right if using a mobile device
Choosing a selection results in a full page refresh.
Press the space key then arrow keys to make a selection.
Shopping Cart
{"id":10024604860733,"title":"G9EC-1-DC12","handle":"g9ec-1-dc12","description":"\u003ch3\u003eOMRON ELECTRONIC COMPONENTS G9EC-1-DC12 DC Power Relay\u003c\/h3\u003e\n\u003cp\u003eIntroducing the \u003cstrong\u003eG9EC-1-DC12\u003c\/strong\u003e DC Power Relay manufactured by \u003cstrong\u003eOMRON ELECTRONIC COMPONENTS\u003c\/strong\u003e. This high-capacity relay is designed for demanding applications requiring reliable switching of high-voltage and high-current loads.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e DC Power Relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e G9EC-1-DC12\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e OMRON ELECTRONIC COMPONENTS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Japan (COO: JP)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUOM:\u003c\/strong\u003e Each (EA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e EAR99\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliant:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Type:\u003c\/strong\u003e Not specified\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDatasheet:\u003c\/strong\u003e \u003ca href=\"https:\/\/4donline.ihs.com\/images\/VipMasterIC\/IC\/OMRN\/OMRN-S-A0001783432\/OMRN-S-A0001783432-1.pdf?hkey=82A29B72BDB3BD67C626B77C2F032848\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDownload Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCapable of switching 200 A at 400 VDC loads with a maximum interruption capacity of 1,000 A at 400 VDC.\u003c\/li\u003e\n\u003cli\u003eCompact dimensions: 98 x 44 x 86.7 mm (L x W x H).\u003c\/li\u003e\n\u003cli\u003eSealed construction with hermetically injected gas, enabling interruption of high-capacity loads safely and efficiently.\u003c\/li\u003e\n\u003cli\u003eDesigned for versatile mounting with no restrictions on orientation.\u003c\/li\u003e\n\u003cli\u003eUL\/CSA standard UL508 approved for industrial safety compliance.\u003c\/li\u003e\n\u003cli\u003eOptional Terminal Cover available for enhanced safety and protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Ratings \u0026amp; Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003cth\u003eRated Current (mA)\u003c\/th\u003e\n\u003cth\u003eCoil Resistance (Ω)\u003c\/th\u003e\n\u003cth\u003eMust-operate Voltage (V)\u003c\/th\u003e\n\u003cth\u003eMust-release Voltage (V)\u003c\/th\u003e\n\u003cth\u003eMaximum Voltage (V)\u003c\/th\u003e\n\u003cth\u003ePower Consumption (W)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12 VDC\u003c\/td\u003e\n\u003ctd\u003e938\u003c\/td\u003e\n\u003ctd\u003e12.8\u003c\/td\u003e\n\u003ctd\u003eApprox. 11\u003c\/td\u003e\n\u003ctd\u003e75% of rated voltage\u003c\/td\u003e\n\u003ctd\u003e8% of rated voltage\u003c\/td\u003e\n\u003ctd\u003e110% of rated voltage (at 23°C, within 10 min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003ctd\u003e469\u003c\/td\u003e\n\u003ctd\u003e51.2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e48 VDC\u003c\/td\u003e\n\u003ctd\u003e234\u003c\/td\u003e\n\u003ctd\u003e204.8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e60 VDC\u003c\/td\u003e\n\u003ctd\u003e188\u003c\/td\u003e\n\u003ctd\u003e320.0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 VDC\u003c\/td\u003e\n\u003ctd\u003e113\u003c\/td\u003e\n\u003ctd\u003e888.9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eContact \u0026amp; Switching Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Load:\u003c\/strong\u003e 200 A at 400 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Switching Voltage:\u003c\/strong\u003e 400 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Switching Current:\u003c\/strong\u003e 200 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Resistance:\u003c\/strong\u003e Max. 30 mΩ (typ. 0.2 mΩ)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Drop:\u003c\/strong\u003e Max. 0.1 V at 200 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperate Time:\u003c\/strong\u003e Max. 50 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelease Time:\u003c\/strong\u003e Max. 30 ms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDurability \u0026amp; Resistance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMechanical Endurance: Min. 200,000 operations\u003c\/li\u003e\n\u003cli\u003eElectrical Endurance (resistive load): Min. 3,000 operations at 400 VDC, 200 A\u003c\/li\u003e\n\u003cli\u003eImpulse withstand voltage: 4,500 V\u003c\/li\u003e\n\u003cli\u003eVibration resistance: Destruction at 10-55 Hz, 0.75 mm amplitude\u003c\/li\u003e\n\u003cli\u003eShock resistance: 490 m\/s² (destruction), 196 m\/s² (malfunction)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDimensions \u0026amp; Mounting\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eDimensions (mm)\u003c\/th\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG9EC-1-B\u003c\/td\u003e\n\u003ctd\u003e98 x 44 x 86.7\u003c\/td\u003e\n\u003ctd\u003eIncludes screw terminals, mounting holes for M6 or 6.5-dia. screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG9EC-1\u003c\/td\u003e\n\u003ctd\u003eDimensions with lead wires available\u003c\/td\u003e\n\u003ctd\u003eRefer to datasheet for detailed mounting and wiring instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplication \u0026amp; Usage\u003c\/h3\u003e\n\u003cp\u003eThis relay is suitable for industrial applications requiring high-current switching, such as power supply systems, motor controls, and high-capacity load management. Ensure proper safety measures and verify equipment compatibility before installation.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: Application examples provided are for reference only. Confirm equipment functions and safety before use. Consult your OMRON representative for conditions outside standard specifications.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eFor more detailed specifications and installation instructions, please refer to the \u003ca href=\"https:\/\/4donline.ihs.com\/images\/VipMasterIC\/IC\/OMRN\/OMRN-S-A0001783432\/OMRN-S-A0001783432-1.pdf?hkey=82A29B72BDB3BD67C626B77C2F032848\" target=\"_blank\" rel=\"noopener noreferrer\"\u003edatasheet\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDisclaimer:\u003c\/strong\u003e Application examples are for reference only. Confirm equipment functions and safety before use. Consult your OMRON representative for applications outside standard specifications.\u003c\/p\u003e\u003cbr\u003e","published_at":"2025-08-14T08:49:18+05:30","created_at":"2025-08-14T08:49:18+05:30","vendor":"Waldom Electonics","type":"","tags":["DC","IMPORT_CSV","OMRON-ELE","Power","Relay","WLDM"],"price":4148444,"price_min":4148444,"price_max":4148444,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50618687390013,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"G9EC-1-DC12","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"G9EC-1-DC12","public_title":null,"options":["Default Title"],"price":4148444,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"G9EC-1-DC12","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/12051920.jpg?v=1755141560"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/12051920.jpg?v=1755141560","options":["Title"],"media":[{"alt":null,"id":45830492946749,"position":1,"preview_image":{"aspect_ratio":1.0,"height":640,"width":640,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/12051920.jpg?v=1755141560"},"aspect_ratio":1.0,"height":640,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/12051920.jpg?v=1755141560","width":640}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eOMRON ELECTRONIC COMPONENTS G9EC-1-DC12 DC Power Relay\u003c\/h3\u003e\n\u003cp\u003eIntroducing the \u003cstrong\u003eG9EC-1-DC12\u003c\/strong\u003e DC Power Relay manufactured by \u003cstrong\u003eOMRON ELECTRONIC COMPONENTS\u003c\/strong\u003e. This high-capacity relay is designed for demanding applications requiring reliable switching of high-voltage and high-current loads.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e DC Power Relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e G9EC-1-DC12\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e OMRON ELECTRONIC COMPONENTS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Japan (COO: JP)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUOM:\u003c\/strong\u003e Each (EA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e EAR99\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliant:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Type:\u003c\/strong\u003e Not specified\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDatasheet:\u003c\/strong\u003e \u003ca href=\"https:\/\/4donline.ihs.com\/images\/VipMasterIC\/IC\/OMRN\/OMRN-S-A0001783432\/OMRN-S-A0001783432-1.pdf?hkey=82A29B72BDB3BD67C626B77C2F032848\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDownload Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCapable of switching 200 A at 400 VDC loads with a maximum interruption capacity of 1,000 A at 400 VDC.\u003c\/li\u003e\n\u003cli\u003eCompact dimensions: 98 x 44 x 86.7 mm (L x W x H).\u003c\/li\u003e\n\u003cli\u003eSealed construction with hermetically injected gas, enabling interruption of high-capacity loads safely and efficiently.\u003c\/li\u003e\n\u003cli\u003eDesigned for versatile mounting with no restrictions on orientation.\u003c\/li\u003e\n\u003cli\u003eUL\/CSA standard UL508 approved for industrial safety compliance.\u003c\/li\u003e\n\u003cli\u003eOptional Terminal Cover available for enhanced safety and protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Ratings \u0026amp; Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003cth\u003eRated Current (mA)\u003c\/th\u003e\n\u003cth\u003eCoil Resistance (Ω)\u003c\/th\u003e\n\u003cth\u003eMust-operate Voltage (V)\u003c\/th\u003e\n\u003cth\u003eMust-release Voltage (V)\u003c\/th\u003e\n\u003cth\u003eMaximum Voltage (V)\u003c\/th\u003e\n\u003cth\u003ePower Consumption (W)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12 VDC\u003c\/td\u003e\n\u003ctd\u003e938\u003c\/td\u003e\n\u003ctd\u003e12.8\u003c\/td\u003e\n\u003ctd\u003eApprox. 11\u003c\/td\u003e\n\u003ctd\u003e75% of rated voltage\u003c\/td\u003e\n\u003ctd\u003e8% of rated voltage\u003c\/td\u003e\n\u003ctd\u003e110% of rated voltage (at 23°C, within 10 min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003ctd\u003e469\u003c\/td\u003e\n\u003ctd\u003e51.2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e48 VDC\u003c\/td\u003e\n\u003ctd\u003e234\u003c\/td\u003e\n\u003ctd\u003e204.8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e60 VDC\u003c\/td\u003e\n\u003ctd\u003e188\u003c\/td\u003e\n\u003ctd\u003e320.0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 VDC\u003c\/td\u003e\n\u003ctd\u003e113\u003c\/td\u003e\n\u003ctd\u003e888.9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eContact \u0026amp; Switching Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Load:\u003c\/strong\u003e 200 A at 400 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Switching Voltage:\u003c\/strong\u003e 400 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Switching Current:\u003c\/strong\u003e 200 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Resistance:\u003c\/strong\u003e Max. 30 mΩ (typ. 0.2 mΩ)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Drop:\u003c\/strong\u003e Max. 0.1 V at 200 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperate Time:\u003c\/strong\u003e Max. 50 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelease Time:\u003c\/strong\u003e Max. 30 ms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDurability \u0026amp; Resistance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMechanical Endurance: Min. 200,000 operations\u003c\/li\u003e\n\u003cli\u003eElectrical Endurance (resistive load): Min. 3,000 operations at 400 VDC, 200 A\u003c\/li\u003e\n\u003cli\u003eImpulse withstand voltage: 4,500 V\u003c\/li\u003e\n\u003cli\u003eVibration resistance: Destruction at 10-55 Hz, 0.75 mm amplitude\u003c\/li\u003e\n\u003cli\u003eShock resistance: 490 m\/s² (destruction), 196 m\/s² (malfunction)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDimensions \u0026amp; Mounting\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eDimensions (mm)\u003c\/th\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG9EC-1-B\u003c\/td\u003e\n\u003ctd\u003e98 x 44 x 86.7\u003c\/td\u003e\n\u003ctd\u003eIncludes screw terminals, mounting holes for M6 or 6.5-dia. screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG9EC-1\u003c\/td\u003e\n\u003ctd\u003eDimensions with lead wires available\u003c\/td\u003e\n\u003ctd\u003eRefer to datasheet for detailed mounting and wiring instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplication \u0026amp; Usage\u003c\/h3\u003e\n\u003cp\u003eThis relay is suitable for industrial applications requiring high-current switching, such as power supply systems, motor controls, and high-capacity load management. Ensure proper safety measures and verify equipment compatibility before installation.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: Application examples provided are for reference only. Confirm equipment functions and safety before use. Consult your OMRON representative for conditions outside standard specifications.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eFor more detailed specifications and installation instructions, please refer to the \u003ca href=\"https:\/\/4donline.ihs.com\/images\/VipMasterIC\/IC\/OMRN\/OMRN-S-A0001783432\/OMRN-S-A0001783432-1.pdf?hkey=82A29B72BDB3BD67C626B77C2F032848\" target=\"_blank\" rel=\"noopener noreferrer\"\u003edatasheet\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDisclaimer:\u003c\/strong\u003e Application examples are for reference only. Confirm equipment functions and safety before use. Consult your OMRON representative for applications outside standard specifications.\u003c\/p\u003e\u003cbr\u003e"}