Use left/right arrows to navigate the slideshow or swipe left/right if using a mobile device
Choosing a selection results in a full page refresh.
Press the space key then arrow keys to make a selection.
Shopping Cart
{"id":10028099240253,"title":"ELB-15-210B2-ES","handle":"elb-15-210b2-es","description":"\u003ch3\u003eTE Connectivity \/ ENERGY Loadbreak Connections ELB-15-210B2-ES\u003c\/h3\u003e\n\u003cp\u003ePart Number: ELB-15-210B2-ES\u003c\/p\u003e\n\u003cp\u003eManufacturer: TE CONNECTIVITY \/ ENERGY\u003c\/p\u003e\n\u003cp\u003eCountry of Origin: COO not specified\u003c\/p\u003e\n\u003cp\u003eUnit of Measure (UOM): Not specified\u003c\/p\u003e\n\u003cp\u003eECCN: EAR99\u003c\/p\u003e\n\u003cp\u003ePackage Type: Not specified\u003c\/p\u003e\n\u003cp\u003eDatasheet: \u003ca href=\"https:\/\/www.te.com\/commerce\/DocumentDelivery\/DDEController?Action=srchrtrv\u0026amp;DocNm=EPP-2820-DDS-5_16-EN-AMS-200A-ELBOW\u0026amp;DocType=Data+Sheet\u0026amp;DocLang=English\u0026amp;PartCntxt=FG1284-000\u0026amp;DocFormat=pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for 15 kV, 200A loadbreak applications\u003c\/li\u003e\n\u003cli\u003eFully shielded and submersible rubber elbow for underground cable terminations\u003c\/li\u003e\n\u003cli\u003eCompatible with extruded (XLPE or EPR) solid dielectric cables\u003c\/li\u003e\n\u003cli\u003eSuitable for cables up to 250 kcmil (for aluminum or copper conductors)\u003c\/li\u003e\n\u003cli\u003ePeroxide cured EPDM rubber ensures low dielectric loss and high dielectric strength\u003c\/li\u003e\n\u003cli\u003eIncludes a copper top compression connector for reliable cable connection\u003c\/li\u003e\n\u003cli\u003eEasy to crimp, suitable for aluminum and copper conductors\u003c\/li\u003e\n\u003cli\u003eCapacitive test point for insulation testing\u003c\/li\u003e\n\u003cli\u003eConforms to IEEE Standard 386 and IEEE 592 for ground shield continuity\u003c\/li\u003e\n\u003cli\u003eOptional integral jacket seal (part number suffix –ES) provides environmental moisture protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eRating\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e15 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e200A (without test point), 210A (with test point)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePartial Discharge\u003c\/td\u003e\n\u003ctd\u003e11 pC (minimum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase-to-Ground Max Rating\u003c\/td\u003e\n\u003ctd\u003e8.3 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase-to-Phase Max Rating\u003c\/td\u003e\n\u003ctd\u003e14.4 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC 60Hz 1-Minute Withstand\u003c\/td\u003e\n\u003ctd\u003e34 kV (rms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC 15-Minute Withstand\u003c\/td\u003e\n\u003ctd\u003e53 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBIL and Full Wave (Crest)\u003c\/td\u003e\n\u003ctd\u003e95 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCable and Conductor Compatibility\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFits cables with insulation diameters from 0.370” to 1.060” (9.4 mm to 26.9 mm)\u003c\/li\u003e\n\u003cli\u003eCompatible with conductor sizes from #2 AWG to 250 kcmil (for aluminum or copper conductors)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent Rating \u0026amp; Test Point Code\u003c\/th\u003e\n\u003cth\u003eCable Insulator Diameter Range\u003c\/th\u003e\n\u003cth\u003eJacket Seal\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200 = 200 AMP WITHOUT test point\u003c\/td\u003e\n\u003ctd\u003eCode A: .575 - .740 in (14.6 - 18.8 mm)\u003cbr\u003eCode B: .640 - .905 in (16.2 - 23.0 mm)\u003cbr\u003eCode C: .830 - 1.060 in (21.1 - 26.9 mm)\u003cbr\u003eCode D: .930 - 1.220 in (23.6 - 31.0 mm)\u003c\/td\u003e\n\u003ctd\u003eNo Jacket Seal: Blank\u003cbr\u003eIntegral Jacket Seal: ES\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eKit Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eElbow body with copper top terminal\u003c\/li\u003e\n\u003cli\u003eLoadbreak probe and installation tool\u003c\/li\u003e\n\u003cli\u003eSealing mastic (for integral seal options)\u003c\/li\u003e\n\u003cli\u003eInstallation instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAdditional Information\u003c\/h3\u003e\n\u003cp\u003eFor more detailed specifications and testing reports, please refer to the \u003ca href=\"https:\/\/www.te.com\/commerce\/DocumentDelivery\/DDEController?Action=srchrtrv\u0026amp;DocNm=EPP-2820-DDS-5_16-EN-AMS-200A-ELBOW\u0026amp;DocType=Data+Sheet\u0026amp;DocLang=English\u0026amp;PartCntxt=FG1284-000\u0026amp;DocFormat=pdf\" target=\"_blank\"\u003efull datasheet\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e The datasheet was not processed; please search the internet for the part number ELB-15-210B2-ES for more details.\u003c\/p\u003e\u003cbr\u003e","published_at":"2025-08-16T07:01:35+05:30","created_at":"2025-08-16T07:01:35+05:30","vendor":"Waldom Electonics","type":"","tags":["ELB","IMPORT_CSV","IMPORT_PT2","TE-ENER","WLDM"],"price":1593797,"price_min":1593797,"price_max":1593797,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50626623963453,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"ELB-15-210B2-ES","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"ELB-15-210B2-ES","public_title":null,"options":["Default Title"],"price":1593797,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"ELB-15-210B2-ES","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/54229314.jpg?v=1755307898"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/54229314.jpg?v=1755307898","options":["Title"],"media":[{"alt":null,"id":45864100397373,"position":1,"preview_image":{"aspect_ratio":1.0,"height":400,"width":400,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/54229314.jpg?v=1755307898"},"aspect_ratio":1.0,"height":400,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/54229314.jpg?v=1755307898","width":400}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eTE Connectivity \/ ENERGY Loadbreak Connections ELB-15-210B2-ES\u003c\/h3\u003e\n\u003cp\u003ePart Number: ELB-15-210B2-ES\u003c\/p\u003e\n\u003cp\u003eManufacturer: TE CONNECTIVITY \/ ENERGY\u003c\/p\u003e\n\u003cp\u003eCountry of Origin: COO not specified\u003c\/p\u003e\n\u003cp\u003eUnit of Measure (UOM): Not specified\u003c\/p\u003e\n\u003cp\u003eECCN: EAR99\u003c\/p\u003e\n\u003cp\u003ePackage Type: Not specified\u003c\/p\u003e\n\u003cp\u003eDatasheet: \u003ca href=\"https:\/\/www.te.com\/commerce\/DocumentDelivery\/DDEController?Action=srchrtrv\u0026amp;DocNm=EPP-2820-DDS-5_16-EN-AMS-200A-ELBOW\u0026amp;DocType=Data+Sheet\u0026amp;DocLang=English\u0026amp;PartCntxt=FG1284-000\u0026amp;DocFormat=pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for 15 kV, 200A loadbreak applications\u003c\/li\u003e\n\u003cli\u003eFully shielded and submersible rubber elbow for underground cable terminations\u003c\/li\u003e\n\u003cli\u003eCompatible with extruded (XLPE or EPR) solid dielectric cables\u003c\/li\u003e\n\u003cli\u003eSuitable for cables up to 250 kcmil (for aluminum or copper conductors)\u003c\/li\u003e\n\u003cli\u003ePeroxide cured EPDM rubber ensures low dielectric loss and high dielectric strength\u003c\/li\u003e\n\u003cli\u003eIncludes a copper top compression connector for reliable cable connection\u003c\/li\u003e\n\u003cli\u003eEasy to crimp, suitable for aluminum and copper conductors\u003c\/li\u003e\n\u003cli\u003eCapacitive test point for insulation testing\u003c\/li\u003e\n\u003cli\u003eConforms to IEEE Standard 386 and IEEE 592 for ground shield continuity\u003c\/li\u003e\n\u003cli\u003eOptional integral jacket seal (part number suffix –ES) provides environmental moisture protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eRating\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e15 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e200A (without test point), 210A (with test point)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePartial Discharge\u003c\/td\u003e\n\u003ctd\u003e11 pC (minimum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase-to-Ground Max Rating\u003c\/td\u003e\n\u003ctd\u003e8.3 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase-to-Phase Max Rating\u003c\/td\u003e\n\u003ctd\u003e14.4 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC 60Hz 1-Minute Withstand\u003c\/td\u003e\n\u003ctd\u003e34 kV (rms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC 15-Minute Withstand\u003c\/td\u003e\n\u003ctd\u003e53 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBIL and Full Wave (Crest)\u003c\/td\u003e\n\u003ctd\u003e95 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCable and Conductor Compatibility\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFits cables with insulation diameters from 0.370” to 1.060” (9.4 mm to 26.9 mm)\u003c\/li\u003e\n\u003cli\u003eCompatible with conductor sizes from #2 AWG to 250 kcmil (for aluminum or copper conductors)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent Rating \u0026amp; Test Point Code\u003c\/th\u003e\n\u003cth\u003eCable Insulator Diameter Range\u003c\/th\u003e\n\u003cth\u003eJacket Seal\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200 = 200 AMP WITHOUT test point\u003c\/td\u003e\n\u003ctd\u003eCode A: .575 - .740 in (14.6 - 18.8 mm)\u003cbr\u003eCode B: .640 - .905 in (16.2 - 23.0 mm)\u003cbr\u003eCode C: .830 - 1.060 in (21.1 - 26.9 mm)\u003cbr\u003eCode D: .930 - 1.220 in (23.6 - 31.0 mm)\u003c\/td\u003e\n\u003ctd\u003eNo Jacket Seal: Blank\u003cbr\u003eIntegral Jacket Seal: ES\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eKit Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eElbow body with copper top terminal\u003c\/li\u003e\n\u003cli\u003eLoadbreak probe and installation tool\u003c\/li\u003e\n\u003cli\u003eSealing mastic (for integral seal options)\u003c\/li\u003e\n\u003cli\u003eInstallation instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAdditional Information\u003c\/h3\u003e\n\u003cp\u003eFor more detailed specifications and testing reports, please refer to the \u003ca href=\"https:\/\/www.te.com\/commerce\/DocumentDelivery\/DDEController?Action=srchrtrv\u0026amp;DocNm=EPP-2820-DDS-5_16-EN-AMS-200A-ELBOW\u0026amp;DocType=Data+Sheet\u0026amp;DocLang=English\u0026amp;PartCntxt=FG1284-000\u0026amp;DocFormat=pdf\" target=\"_blank\"\u003efull datasheet\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e The datasheet was not processed; please search the internet for the part number ELB-15-210B2-ES for more details.\u003c\/p\u003e\u003cbr\u003e"}