The Part Number: TEQ 160-7212WIR Manufacturer: TRACO ELEC. AG Country of Origin: TW UOM: EA ECCN: EAR99 Package Type: BOX Product Type: DC-DC Converter | Isolated DC/DC Converters
The TEQ 160WIR Series offers high-performance isolated DC/DC converter modules with an ultra-wide 4:1 input voltage range, designed for demanding industrial and railway applications. Encased in a rugged, sealed metal case, these converters deliver reliable power conversion with excellent thermal management and efficiency.
Key Features
High power output of 160 Watts with excellent thermal convection cooling
Operating temperature range from -40°C to +75°C without derating, up to +90°C with derating
Efficiency up to 90% for optimal power utilization
Isolation: Input to Output 1591 VAC, Input to Case 1600 VAC, Output to Case 1600 VAC
Compliance with UL 508, IEC 62368-1, EN 50155 for railway applications
Protection features include short circuit, overvoltage, and overtemperature shutdown
Electrical Specifications
Model
Input Voltage Range
Output Voltage Nom.
Max Output Current
Efficiency (Typ.)
TEQ 160-4812WIR
19 - 75 VDC
12 VDC
13,000 mA
90%
TEQ 160-4815WIR
19 - 75 VDC
24 VDC
6,500 mA
90%
TEQ 160-4816WIR
19 - 75 VDC
28 VDC
5,500 mA
90%
TEQ 160-4818WIR
19 - 75 VDC
48 VDC
3,200 mA
90%
TEQ 160-7212WIR
43 - 160 VDC
12 VDC
15,000 mA
89%
TEQ 160-7215WIR
43 - 160 VDC
24 VDC
7,500 mA
89%
TEQ 160-7216WIR
43 - 160 VDC
28 VDC
6,500 mA
89%
TEQ 160-7218WIR
43 - 160 VDC
48 VDC
3,800 mA
89%
Additional Features
Ripple and Noise: up to 350 mVp-p depending on model
Capacitive Load:
12 V models: up to 12,500 µF
24 V models: up to 3,100 µF
28 V models: up to 2,300 µF
48 V models: up to 790 µF
Start-up time approximately 75 ms
MTBF estimated at 400,000 hours
Natural convection cooling, suitable for harsh environments
Designed for applications requiring high shock and vibration resistance
Environmental & Safety Standards
RoHS compliant
UL 62368-1, IEC 62368-1, UL 508, CSA-C22.2, No 107.1
EN 50155 (railway), EN 61373 (vibration and shock)
EMI/EMC: EN 55011, EN 55032, EN 61000-4 series
Operating temperature: -40°C to +90°C
Humidity: up to 95% non-condensing
Pollution Degree: PD 2
Dimensions & Connections
Terminal
Pin Function
Recommended Wire
1, 2
–Vin
12 AWG
3
NC
NC
4
On/Off Ctrl
14 - 18 AWG
5, 6
+Vin
12 AWG
7, 8
–Vout
12 AWG
9
–Sense
14 - 18 AWG
10
+Sense
14 - 18 AWG
11, 12
+Vout
12 AWG
For detailed specifications and datasheet, please click here.
Note: All specifications are valid at nominal voltage, full load, and +25°C after warm-up unless otherwise specified. Please refer to the datasheet for comprehensive details.
{"id":10021803196733,"title":"TEQ 160-7212WIR","handle":"teq-160-7212wir","description":"\u003ch3\u003eDC\/DC Converter TEQ 160WIR Series, 160 Watt\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003ePart Number:\u003c\/strong\u003e TEQ 160-7212WIR\u003cbr\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e TRACO ELEC. AG\u003cbr\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e TW\u003cbr\u003e\n\u003cstrong\u003eUOM:\u003c\/strong\u003e EA\u003cbr\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e EAR99\u003cbr\u003e\n\u003cstrong\u003ePackage Type:\u003c\/strong\u003e BOX\u003cbr\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e DC-DC Converter | Isolated DC\/DC Converters\u003c\/p\u003e\n\u003cp\u003eThe TEQ 160WIR Series offers high-performance isolated DC\/DC converter modules with an ultra-wide 4:1 input voltage range, designed for demanding industrial and railway applications. Encased in a rugged, sealed metal case, these converters deliver reliable power conversion with excellent thermal management and efficiency.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh power output of 160 Watts with excellent thermal convection cooling\u003c\/li\u003e\n\u003cli\u003eOperating temperature range from -40°C to +75°C without derating, up to +90°C with derating\u003c\/li\u003e\n\u003cli\u003eEfficiency up to 90% for optimal power utilization\u003c\/li\u003e\n\u003cli\u003eInput filter compliant with EN 55022, class A\u003c\/li\u003e\n\u003cli\u003eInput voltage range:\n \u003cul\u003e\n\u003cli\u003e19 - 75 VDC (48 VDC nom.)\u003c\/li\u003e\n\u003cli\u003e43 - 160 VDC (110 VDC nom.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eOutput voltages available: 12 VDC, 24 VDC, 28 VDC, 48 VDC\u003c\/li\u003e\n\u003cli\u003eMaximum output current:\n \u003cul\u003e\n\u003cli\u003e13,000 mA (12 VDC)\u003c\/li\u003e\n\u003cli\u003e6,500 mA (24 VDC)\u003c\/li\u003e\n\u003cli\u003e5,500 mA (28 VDC)\u003c\/li\u003e\n\u003cli\u003e3,200 mA (48 VDC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eOutput voltage trimming: -20% to +10%\u003c\/li\u003e\n\u003cli\u003eRemote On\/Off control and under voltage lockout\u003c\/li\u003e\n\u003cli\u003eIsolation: Input to Output 1591 VAC, Input to Case 1600 VAC, Output to Case 1600 VAC\u003c\/li\u003e\n\u003cli\u003eCompliance with UL 508, IEC 62368-1, EN 50155 for railway applications\u003c\/li\u003e\n\u003cli\u003eProtection features include short circuit, overvoltage, and overtemperature shutdown\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eInput Voltage Range\u003c\/th\u003e\n\u003cth\u003eOutput Voltage Nom.\u003c\/th\u003e\n\u003cth\u003eMax Output Current\u003c\/th\u003e\n\u003cth\u003eEfficiency (Typ.)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTEQ 160-4812WIR\u003c\/td\u003e\n\u003ctd\u003e19 - 75 VDC\u003c\/td\u003e\n\u003ctd\u003e12 VDC\u003c\/td\u003e\n\u003ctd\u003e13,000 mA\u003c\/td\u003e\n\u003ctd\u003e90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTEQ 160-4815WIR\u003c\/td\u003e\n\u003ctd\u003e19 - 75 VDC\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003ctd\u003e6,500 mA\u003c\/td\u003e\n\u003ctd\u003e90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTEQ 160-4816WIR\u003c\/td\u003e\n\u003ctd\u003e19 - 75 VDC\u003c\/td\u003e\n\u003ctd\u003e28 VDC\u003c\/td\u003e\n\u003ctd\u003e5,500 mA\u003c\/td\u003e\n\u003ctd\u003e90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTEQ 160-4818WIR\u003c\/td\u003e\n\u003ctd\u003e19 - 75 VDC\u003c\/td\u003e\n\u003ctd\u003e48 VDC\u003c\/td\u003e\n\u003ctd\u003e3,200 mA\u003c\/td\u003e\n\u003ctd\u003e90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTEQ 160-7212WIR\u003c\/td\u003e\n\u003ctd\u003e43 - 160 VDC\u003c\/td\u003e\n\u003ctd\u003e12 VDC\u003c\/td\u003e\n\u003ctd\u003e15,000 mA\u003c\/td\u003e\n\u003ctd\u003e89%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTEQ 160-7215WIR\u003c\/td\u003e\n\u003ctd\u003e43 - 160 VDC\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003ctd\u003e7,500 mA\u003c\/td\u003e\n\u003ctd\u003e89%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTEQ 160-7216WIR\u003c\/td\u003e\n\u003ctd\u003e43 - 160 VDC\u003c\/td\u003e\n\u003ctd\u003e28 VDC\u003c\/td\u003e\n\u003ctd\u003e6,500 mA\u003c\/td\u003e\n\u003ctd\u003e89%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTEQ 160-7218WIR\u003c\/td\u003e\n\u003ctd\u003e43 - 160 VDC\u003c\/td\u003e\n\u003ctd\u003e48 VDC\u003c\/td\u003e\n\u003ctd\u003e3,800 mA\u003c\/td\u003e\n\u003ctd\u003e89%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAdditional Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRipple and Noise: up to 350 mVp-p depending on model\u003c\/li\u003e\n\u003cli\u003eCapacitive Load:\n \u003cul\u003e\n\u003cli\u003e12 V models: up to 12,500 µF\u003c\/li\u003e\n\u003cli\u003e24 V models: up to 3,100 µF\u003c\/li\u003e\n\u003cli\u003e28 V models: up to 2,300 µF\u003c\/li\u003e\n\u003cli\u003e48 V models: up to 790 µF\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eStart-up time approximately 75 ms\u003c\/li\u003e\n\u003cli\u003eMTBF estimated at 400,000 hours\u003c\/li\u003e\n\u003cli\u003eNatural convection cooling, suitable for harsh environments\u003c\/li\u003e\n\u003cli\u003eDesigned for applications requiring high shock and vibration resistance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental \u0026amp; Safety Standards\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eUL 62368-1, IEC 62368-1, UL 508, CSA-C22.2, No 107.1\u003c\/li\u003e\n\u003cli\u003eEN 50155 (railway), EN 61373 (vibration and shock)\u003c\/li\u003e\n\u003cli\u003eEMI\/EMC: EN 55011, EN 55032, EN 61000-4 series\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -40°C to +90°C\u003c\/li\u003e\n\u003cli\u003eHumidity: up to 95% non-condensing\u003c\/li\u003e\n\u003cli\u003ePollution Degree: PD 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDimensions \u0026amp; Connections\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal\u003c\/th\u003e\n\u003cth\u003ePin Function\u003c\/th\u003e\n\u003cth\u003eRecommended Wire\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1, 2\u003c\/td\u003e\n\u003ctd\u003e–Vin\u003c\/td\u003e\n\u003ctd\u003e12 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003eNC\u003c\/td\u003e\n\u003ctd\u003eNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003eOn\/Off Ctrl\u003c\/td\u003e\n\u003ctd\u003e14 - 18 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5, 6\u003c\/td\u003e\n\u003ctd\u003e+Vin\u003c\/td\u003e\n\u003ctd\u003e12 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7, 8\u003c\/td\u003e\n\u003ctd\u003e–Vout\u003c\/td\u003e\n\u003ctd\u003e12 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003e–Sense\u003c\/td\u003e\n\u003ctd\u003e14 - 18 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e+Sense\u003c\/td\u003e\n\u003ctd\u003e14 - 18 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e11, 12\u003c\/td\u003e\n\u003ctd\u003e+Vout\u003c\/td\u003e\n\u003ctd\u003e12 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eFor detailed specifications and datasheet, please \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-tra\/tra-teq-160-7212wir.pdf\" target=\"_blank\"\u003eclick here\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eNote: All specifications are valid at nominal voltage, full load, and +25°C after warm-up unless otherwise specified. Please refer to the datasheet for comprehensive details.\u003c\/p\u003e","published_at":"2025-08-12T22:46:03+05:30","created_at":"2025-08-12T22:46:03+05:30","vendor":"Waldom Electonics","type":"DC-DC Converter","tags":["12V","180W","DC","IMPORT_CSV","Isolated","TRACO","WLDM"],"price":6331114,"price_min":6331114,"price_max":6331114,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50613269168445,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"TEQ 160-7212WIR","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"TEQ 160-7212WIR","public_title":null,"options":["Default Title"],"price":6331114,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"TEQ 160-7212WIR","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/TEQ_160-7212WIR_55971821_a0043bf4.jpg?v=1755018967"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/TEQ_160-7212WIR_55971821_a0043bf4.jpg?v=1755018967","options":["Title"],"media":[{"alt":null,"id":45806608187709,"position":1,"preview_image":{"aspect_ratio":1.34,"height":200,"width":268,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/TEQ_160-7212WIR_55971821_a0043bf4.jpg?v=1755018967"},"aspect_ratio":1.34,"height":200,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/TEQ_160-7212WIR_55971821_a0043bf4.jpg?v=1755018967","width":268}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eDC\/DC Converter TEQ 160WIR Series, 160 Watt\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003ePart Number:\u003c\/strong\u003e TEQ 160-7212WIR\u003cbr\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e TRACO ELEC. AG\u003cbr\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e TW\u003cbr\u003e\n\u003cstrong\u003eUOM:\u003c\/strong\u003e EA\u003cbr\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e EAR99\u003cbr\u003e\n\u003cstrong\u003ePackage Type:\u003c\/strong\u003e BOX\u003cbr\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e DC-DC Converter | Isolated DC\/DC Converters\u003c\/p\u003e\n\u003cp\u003eThe TEQ 160WIR Series offers high-performance isolated DC\/DC converter modules with an ultra-wide 4:1 input voltage range, designed for demanding industrial and railway applications. Encased in a rugged, sealed metal case, these converters deliver reliable power conversion with excellent thermal management and efficiency.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh power output of 160 Watts with excellent thermal convection cooling\u003c\/li\u003e\n\u003cli\u003eOperating temperature range from -40°C to +75°C without derating, up to +90°C with derating\u003c\/li\u003e\n\u003cli\u003eEfficiency up to 90% for optimal power utilization\u003c\/li\u003e\n\u003cli\u003eInput filter compliant with EN 55022, class A\u003c\/li\u003e\n\u003cli\u003eInput voltage range:\n \u003cul\u003e\n\u003cli\u003e19 - 75 VDC (48 VDC nom.)\u003c\/li\u003e\n\u003cli\u003e43 - 160 VDC (110 VDC nom.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eOutput voltages available: 12 VDC, 24 VDC, 28 VDC, 48 VDC\u003c\/li\u003e\n\u003cli\u003eMaximum output current:\n \u003cul\u003e\n\u003cli\u003e13,000 mA (12 VDC)\u003c\/li\u003e\n\u003cli\u003e6,500 mA (24 VDC)\u003c\/li\u003e\n\u003cli\u003e5,500 mA (28 VDC)\u003c\/li\u003e\n\u003cli\u003e3,200 mA (48 VDC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eOutput voltage trimming: -20% to +10%\u003c\/li\u003e\n\u003cli\u003eRemote On\/Off control and under voltage lockout\u003c\/li\u003e\n\u003cli\u003eIsolation: Input to Output 1591 VAC, Input to Case 1600 VAC, Output to Case 1600 VAC\u003c\/li\u003e\n\u003cli\u003eCompliance with UL 508, IEC 62368-1, EN 50155 for railway applications\u003c\/li\u003e\n\u003cli\u003eProtection features include short circuit, overvoltage, and overtemperature shutdown\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eInput Voltage Range\u003c\/th\u003e\n\u003cth\u003eOutput Voltage Nom.\u003c\/th\u003e\n\u003cth\u003eMax Output Current\u003c\/th\u003e\n\u003cth\u003eEfficiency (Typ.)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTEQ 160-4812WIR\u003c\/td\u003e\n\u003ctd\u003e19 - 75 VDC\u003c\/td\u003e\n\u003ctd\u003e12 VDC\u003c\/td\u003e\n\u003ctd\u003e13,000 mA\u003c\/td\u003e\n\u003ctd\u003e90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTEQ 160-4815WIR\u003c\/td\u003e\n\u003ctd\u003e19 - 75 VDC\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003ctd\u003e6,500 mA\u003c\/td\u003e\n\u003ctd\u003e90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTEQ 160-4816WIR\u003c\/td\u003e\n\u003ctd\u003e19 - 75 VDC\u003c\/td\u003e\n\u003ctd\u003e28 VDC\u003c\/td\u003e\n\u003ctd\u003e5,500 mA\u003c\/td\u003e\n\u003ctd\u003e90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTEQ 160-4818WIR\u003c\/td\u003e\n\u003ctd\u003e19 - 75 VDC\u003c\/td\u003e\n\u003ctd\u003e48 VDC\u003c\/td\u003e\n\u003ctd\u003e3,200 mA\u003c\/td\u003e\n\u003ctd\u003e90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTEQ 160-7212WIR\u003c\/td\u003e\n\u003ctd\u003e43 - 160 VDC\u003c\/td\u003e\n\u003ctd\u003e12 VDC\u003c\/td\u003e\n\u003ctd\u003e15,000 mA\u003c\/td\u003e\n\u003ctd\u003e89%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTEQ 160-7215WIR\u003c\/td\u003e\n\u003ctd\u003e43 - 160 VDC\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003ctd\u003e7,500 mA\u003c\/td\u003e\n\u003ctd\u003e89%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTEQ 160-7216WIR\u003c\/td\u003e\n\u003ctd\u003e43 - 160 VDC\u003c\/td\u003e\n\u003ctd\u003e28 VDC\u003c\/td\u003e\n\u003ctd\u003e6,500 mA\u003c\/td\u003e\n\u003ctd\u003e89%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTEQ 160-7218WIR\u003c\/td\u003e\n\u003ctd\u003e43 - 160 VDC\u003c\/td\u003e\n\u003ctd\u003e48 VDC\u003c\/td\u003e\n\u003ctd\u003e3,800 mA\u003c\/td\u003e\n\u003ctd\u003e89%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAdditional Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRipple and Noise: up to 350 mVp-p depending on model\u003c\/li\u003e\n\u003cli\u003eCapacitive Load:\n \u003cul\u003e\n\u003cli\u003e12 V models: up to 12,500 µF\u003c\/li\u003e\n\u003cli\u003e24 V models: up to 3,100 µF\u003c\/li\u003e\n\u003cli\u003e28 V models: up to 2,300 µF\u003c\/li\u003e\n\u003cli\u003e48 V models: up to 790 µF\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eStart-up time approximately 75 ms\u003c\/li\u003e\n\u003cli\u003eMTBF estimated at 400,000 hours\u003c\/li\u003e\n\u003cli\u003eNatural convection cooling, suitable for harsh environments\u003c\/li\u003e\n\u003cli\u003eDesigned for applications requiring high shock and vibration resistance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental \u0026amp; Safety Standards\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eUL 62368-1, IEC 62368-1, UL 508, CSA-C22.2, No 107.1\u003c\/li\u003e\n\u003cli\u003eEN 50155 (railway), EN 61373 (vibration and shock)\u003c\/li\u003e\n\u003cli\u003eEMI\/EMC: EN 55011, EN 55032, EN 61000-4 series\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -40°C to +90°C\u003c\/li\u003e\n\u003cli\u003eHumidity: up to 95% non-condensing\u003c\/li\u003e\n\u003cli\u003ePollution Degree: PD 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDimensions \u0026amp; Connections\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal\u003c\/th\u003e\n\u003cth\u003ePin Function\u003c\/th\u003e\n\u003cth\u003eRecommended Wire\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1, 2\u003c\/td\u003e\n\u003ctd\u003e–Vin\u003c\/td\u003e\n\u003ctd\u003e12 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003eNC\u003c\/td\u003e\n\u003ctd\u003eNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003eOn\/Off Ctrl\u003c\/td\u003e\n\u003ctd\u003e14 - 18 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5, 6\u003c\/td\u003e\n\u003ctd\u003e+Vin\u003c\/td\u003e\n\u003ctd\u003e12 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7, 8\u003c\/td\u003e\n\u003ctd\u003e–Vout\u003c\/td\u003e\n\u003ctd\u003e12 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003e–Sense\u003c\/td\u003e\n\u003ctd\u003e14 - 18 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e+Sense\u003c\/td\u003e\n\u003ctd\u003e14 - 18 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e11, 12\u003c\/td\u003e\n\u003ctd\u003e+Vout\u003c\/td\u003e\n\u003ctd\u003e12 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eFor detailed specifications and datasheet, please \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-tra\/tra-teq-160-7212wir.pdf\" target=\"_blank\"\u003eclick here\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eNote: All specifications are valid at nominal voltage, full load, and +25°C after warm-up unless otherwise specified. Please refer to the datasheet for comprehensive details.\u003c\/p\u003e"}