DC-DC Regulated Power Supply Module - Part Number: THM 6-1211
Manufactured by TRACO ELEC. AG, this high-performance isolated DC-DC converter is designed for demanding applications requiring reliable power conversion. With a compact TUBE package, it offers excellent electrical isolation and efficiency, making it suitable for medical, transportation, control, measurement, and IGBT driver applications.
Compact DIP-24 plastic case for space-saving integration
High isolation voltage of 5000 VAC rated for 250 VAC working voltage
IEC 60601-1 certification for 2 x MOPP, suitable for medical applications
Low leakage current <2 µA, ensuring safety and compliance
Wide operating temperature range from –40°C to +90°C
High efficiency up to 89%, reducing power loss and heat generation
Designed with high-grade components for reliability
Automatic short circuit protection and output current limitation at 150%
Overvoltage protection within 112-152% of Vout nominal
Electrical Specifications
Input Voltage Range
Output Voltage (Vnom)
Output Current (Imax)
Efficiency (typ.)
9 - 18 VDC (12 VDC nom.)
3.3 V / 5 V / 12 V / 15 V / 24 V / +5 V / +12 V / +15 V
1,200 mA / 500 mA / 400 mA / 250 mA / 200 mA / 600 mA / 250 mA / 200 mA
84% - 89%
Additional Specifications
Input Current at no load: 10 - 20 mA depending on model
Surge Voltage: Up to 100 VDC (48 V models)
Input Filter: Internal Pi-Type
Output Voltage Adjustment: ±10% (for models with adjustable output)
Ripple & Noise (20 MHz bandwidth): 30-50 mVp-p depending on output voltage
Capacitive Load (max): 75 - 2,100 µF depending on model
Start-up Time: Approx. 30 ms
Protection: Continuous, automatic recovery from short circuit
Environmental & Mechanical Details
Operating Temperature: –40°C to +90°C
Storage Temperature: –55°C to +125°C
Isolation Test Voltage: 5,000 VAC (60 seconds)
Leakage Current: <2 µA
Dimensions: Refer to datasheet for detailed outline dimensions
Weight: Approx. 14 g
Certifications & Compliance
IEC 60601-1, IEC 62368-1, UL 62368-1
RoHS Compliant, REACH compliant
EMC and EMI standards met for medical and industrial environments
For more detailed specifications and application guidelines, please refer to the datasheet. The product is designed to meet rigorous safety and performance standards, ensuring reliable operation in critical applications.
Note: Datasheet was not processed please search the internet for the part number for more details.
{"id":10021819547965,"title":"THM 6-1211","handle":"thm-6-1211","description":"\u003ch3\u003eDC-DC Regulated Power Supply Module - Part Number: THM 6-1211\u003c\/h3\u003e\n\u003cp\u003eManufactured by TRACO ELEC. AG, this high-performance isolated DC-DC converter is designed for demanding applications requiring reliable power conversion. With a compact TUBE package, it offers excellent electrical isolation and efficiency, making it suitable for medical, transportation, control, measurement, and IGBT driver applications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e DC-DC Converter | Isolated DC\/DC Converter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e THM 6-1211\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e TRACO ELEC. AG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Taiwan (TW)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Type:\u003c\/strong\u003e TUBE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUOM:\u003c\/strong\u003e EA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e EAR99\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDatasheet:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-tra\/tra-thm-6-1211.pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompact DIP-24 plastic case for space-saving integration\u003c\/li\u003e\n\u003cli\u003eHigh isolation voltage of 5000 VAC rated for 250 VAC working voltage\u003c\/li\u003e\n\u003cli\u003eIEC 60601-1 certification for 2 x MOPP, suitable for medical applications\u003c\/li\u003e\n\u003cli\u003eLow leakage current \u0026lt;2 µA, ensuring safety and compliance\u003c\/li\u003e\n\u003cli\u003eWide operating temperature range from –40°C to +90°C\u003c\/li\u003e\n\u003cli\u003eHigh efficiency up to 89%, reducing power loss and heat generation\u003c\/li\u003e\n\u003cli\u003eDesigned with high-grade components for reliability\u003c\/li\u003e\n\u003cli\u003eAutomatic short circuit protection and output current limitation at 150%\u003c\/li\u003e\n\u003cli\u003eOvervoltage protection within 112-152% of Vout nominal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage Range\u003c\/th\u003e\n\u003cth\u003eOutput Voltage (Vnom)\u003c\/th\u003e\n\u003cth\u003eOutput Current (Imax)\u003c\/th\u003e\n\u003cth\u003eEfficiency (typ.)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e9 - 18 VDC (12 VDC nom.)\u003c\/td\u003e\n\u003ctd\u003e3.3 V \/ 5 V \/ 12 V \/ 15 V \/ 24 V \/ +5 V \/ +12 V \/ +15 V\u003c\/td\u003e\n\u003ctd\u003e1,200 mA \/ 500 mA \/ 400 mA \/ 250 mA \/ 200 mA \/ 600 mA \/ 250 mA \/ 200 mA\u003c\/td\u003e\n\u003ctd\u003e84% - 89%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAdditional Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInput Current at no load: 10 - 20 mA depending on model\u003c\/li\u003e\n\u003cli\u003eSurge Voltage: Up to 100 VDC (48 V models)\u003c\/li\u003e\n\u003cli\u003eInput Filter: Internal Pi-Type\u003c\/li\u003e\n\u003cli\u003eOutput Voltage Adjustment: ±10% (for models with adjustable output)\u003c\/li\u003e\n\u003cli\u003eRipple \u0026amp; Noise (20 MHz bandwidth): 30-50 mVp-p depending on output voltage\u003c\/li\u003e\n\u003cli\u003eCapacitive Load (max): 75 - 2,100 µF depending on model\u003c\/li\u003e\n\u003cli\u003eStart-up Time: Approx. 30 ms\u003c\/li\u003e\n\u003cli\u003eProtection: Continuous, automatic recovery from short circuit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental \u0026amp; Mechanical Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Temperature: –40°C to +90°C\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: –55°C to +125°C\u003c\/li\u003e\n\u003cli\u003eIsolation Test Voltage: 5,000 VAC (60 seconds)\u003c\/li\u003e\n\u003cli\u003eLeakage Current: \u0026lt;2 µA\u003c\/li\u003e\n\u003cli\u003eDimensions: Refer to datasheet for detailed outline dimensions\u003c\/li\u003e\n\u003cli\u003eWeight: Approx. 14 g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCertifications \u0026amp; Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIEC 60601-1, IEC 62368-1, UL 62368-1\u003c\/li\u003e\n\u003cli\u003eRoHS Compliant, REACH compliant\u003c\/li\u003e\n\u003cli\u003eEMC and EMI standards met for medical and industrial environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor more detailed specifications and application guidelines, please refer to the \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-tra\/tra-thm-6-1211.pdf\" target=\"_blank\"\u003edatasheet\u003c\/a\u003e. The product is designed to meet rigorous safety and performance standards, ensuring reliable operation in critical applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Datasheet was not processed please search the internet for the part number for more details.\u003c\/p\u003e","published_at":"2025-08-12T22:58:16+05:30","created_at":"2025-08-12T22:58:16+05:30","vendor":"Waldom Electonics","type":"DC-DC Converter","tags":["30W","DC","IMPORT_CSV","IMPORT_PT2","Isolated","Power","TRACO","WLDM"],"price":782069,"price_min":782069,"price_max":782069,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50613304033597,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"THM 6-1211","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"THM 6-1211","public_title":null,"options":["Default Title"],"price":782069,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"THM 6-1211","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/THM_6-1211_55983189_5cfb6c4b.jpg?v=1755019699"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/THM_6-1211_55983189_5cfb6c4b.jpg?v=1755019699","options":["Title"],"media":[{"alt":null,"id":45806766588221,"position":1,"preview_image":{"aspect_ratio":1.0,"height":200,"width":200,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/THM_6-1211_55983189_5cfb6c4b.jpg?v=1755019699"},"aspect_ratio":1.0,"height":200,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/THM_6-1211_55983189_5cfb6c4b.jpg?v=1755019699","width":200}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eDC-DC Regulated Power Supply Module - Part Number: THM 6-1211\u003c\/h3\u003e\n\u003cp\u003eManufactured by TRACO ELEC. AG, this high-performance isolated DC-DC converter is designed for demanding applications requiring reliable power conversion. With a compact TUBE package, it offers excellent electrical isolation and efficiency, making it suitable for medical, transportation, control, measurement, and IGBT driver applications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e DC-DC Converter | Isolated DC\/DC Converter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e THM 6-1211\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e TRACO ELEC. AG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Taiwan (TW)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Type:\u003c\/strong\u003e TUBE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUOM:\u003c\/strong\u003e EA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e EAR99\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDatasheet:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-tra\/tra-thm-6-1211.pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompact DIP-24 plastic case for space-saving integration\u003c\/li\u003e\n\u003cli\u003eHigh isolation voltage of 5000 VAC rated for 250 VAC working voltage\u003c\/li\u003e\n\u003cli\u003eIEC 60601-1 certification for 2 x MOPP, suitable for medical applications\u003c\/li\u003e\n\u003cli\u003eLow leakage current \u0026lt;2 µA, ensuring safety and compliance\u003c\/li\u003e\n\u003cli\u003eWide operating temperature range from –40°C to +90°C\u003c\/li\u003e\n\u003cli\u003eHigh efficiency up to 89%, reducing power loss and heat generation\u003c\/li\u003e\n\u003cli\u003eDesigned with high-grade components for reliability\u003c\/li\u003e\n\u003cli\u003eAutomatic short circuit protection and output current limitation at 150%\u003c\/li\u003e\n\u003cli\u003eOvervoltage protection within 112-152% of Vout nominal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage Range\u003c\/th\u003e\n\u003cth\u003eOutput Voltage (Vnom)\u003c\/th\u003e\n\u003cth\u003eOutput Current (Imax)\u003c\/th\u003e\n\u003cth\u003eEfficiency (typ.)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e9 - 18 VDC (12 VDC nom.)\u003c\/td\u003e\n\u003ctd\u003e3.3 V \/ 5 V \/ 12 V \/ 15 V \/ 24 V \/ +5 V \/ +12 V \/ +15 V\u003c\/td\u003e\n\u003ctd\u003e1,200 mA \/ 500 mA \/ 400 mA \/ 250 mA \/ 200 mA \/ 600 mA \/ 250 mA \/ 200 mA\u003c\/td\u003e\n\u003ctd\u003e84% - 89%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAdditional Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInput Current at no load: 10 - 20 mA depending on model\u003c\/li\u003e\n\u003cli\u003eSurge Voltage: Up to 100 VDC (48 V models)\u003c\/li\u003e\n\u003cli\u003eInput Filter: Internal Pi-Type\u003c\/li\u003e\n\u003cli\u003eOutput Voltage Adjustment: ±10% (for models with adjustable output)\u003c\/li\u003e\n\u003cli\u003eRipple \u0026amp; Noise (20 MHz bandwidth): 30-50 mVp-p depending on output voltage\u003c\/li\u003e\n\u003cli\u003eCapacitive Load (max): 75 - 2,100 µF depending on model\u003c\/li\u003e\n\u003cli\u003eStart-up Time: Approx. 30 ms\u003c\/li\u003e\n\u003cli\u003eProtection: Continuous, automatic recovery from short circuit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental \u0026amp; Mechanical Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Temperature: –40°C to +90°C\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: –55°C to +125°C\u003c\/li\u003e\n\u003cli\u003eIsolation Test Voltage: 5,000 VAC (60 seconds)\u003c\/li\u003e\n\u003cli\u003eLeakage Current: \u0026lt;2 µA\u003c\/li\u003e\n\u003cli\u003eDimensions: Refer to datasheet for detailed outline dimensions\u003c\/li\u003e\n\u003cli\u003eWeight: Approx. 14 g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCertifications \u0026amp; Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIEC 60601-1, IEC 62368-1, UL 62368-1\u003c\/li\u003e\n\u003cli\u003eRoHS Compliant, REACH compliant\u003c\/li\u003e\n\u003cli\u003eEMC and EMI standards met for medical and industrial environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor more detailed specifications and application guidelines, please refer to the \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-tra\/tra-thm-6-1211.pdf\" target=\"_blank\"\u003edatasheet\u003c\/a\u003e. The product is designed to meet rigorous safety and performance standards, ensuring reliable operation in critical applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Datasheet was not processed please search the internet for the part number for more details.\u003c\/p\u003e"}