XP POWER JCA1024S05 Isolated DC/DC Converter - Through Hole, 10W
Introducing the JCA1024S05 isolated DC/DC converter manufactured by XP POWER. Designed for reliable power conversion in industrial and electronic applications, this compact module offers high efficiency and robust performance.
{"id":10021816729917,"title":"JCA1024S05","handle":"jca1024s05","description":"\u003ch3\u003eXP POWER JCA1024S05 Isolated DC\/DC Converter - Through Hole, 10W\u003c\/h3\u003e\n\u003cp\u003eIntroducing the \u003cstrong\u003eJCA1024S05\u003c\/strong\u003e isolated DC\/DC converter manufactured by \u003cstrong\u003eXP POWER\u003c\/strong\u003e. Designed for reliable power conversion in industrial and electronic applications, this compact module offers high efficiency and robust performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Details:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e JCA1024S05\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e XP POWER\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e TW (Taiwan)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit of Measure:\u003c\/strong\u003e EA (Each)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e EAR99\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Type:\u003c\/strong\u003e TUBE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDatasheet:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-xpp\/xpp-jca1024s05.pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower Rating: 10 Watts\u003c\/li\u003e\n\u003cli\u003eInput Voltage Range:\n \u003cul\u003e\n \u003cli\u003e5 VDC (4.5-9.0 VDC)\u003c\/li\u003e\n \u003cli\u003e12 VDC (9-18 VDC)\u003c\/li\u003e\n \u003cli\u003e24 VDC (18-36 VDC)\u003c\/li\u003e\n \u003cli\u003e48 VDC (36-75 VDC)\u003c\/li\u003e\n \u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eOutput Voltage Options:\n \u003cul\u003e\n \u003cli\u003e3.3 V, 5 V, 12 V, 15 V (single output)\u003c\/li\u003e\n \u003cli\u003e±5 V, ±12 V, ±15 V (dual output)\u003c\/li\u003e\n \u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eEfficiency up to 90%\u003c\/li\u003e\n\u003cli\u003eIsolation Voltage: 1500 VDC (input to output)\u003c\/li\u003e\n\u003cli\u003eOperating Temperature Range: -40°C to +100°C\u003c\/li\u003e\n\u003cli\u003eCompact Size: 1.0” x 0.8” Metal Package\u003c\/li\u003e\n\u003cli\u003eIndustry Standard Pinout with Through Hole Mounting\u003c\/li\u003e\n\u003cli\u003eHigh Reliability with \u0026gt;950,000 hours MTBF\u003c\/li\u003e\n\u003cli\u003eCompliance: UL, CB, TUV Approvals\u003c\/li\u003e\n\u003cli\u003eOperating Humidity: Up to 95% RH, non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003cth\u003eOutput Voltage\u003c\/th\u003e\n\u003cth\u003eOutput Current\u003c\/th\u003e\n\u003cth\u003eEfficiency\u003c\/th\u003e\n\u003cth\u003eInput Current (at nominal input)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 VDC\u003c\/td\u003e\n\u003ctd\u003e3.3 V \/ 5 V \/ 12 V \/ 15 V\u003c\/td\u003e\n\u003ctd\u003eup to 2.42 A\u003c\/td\u003e\n\u003ctd\u003eup to 86%\u003c\/td\u003e\n\u003ctd\u003e84 mA (for 5 V input models)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12 VDC\u003c\/td\u003e\n\u003ctd\u003e3.3 V \/ 5 V \/ 12 V \/ 15 V\u003c\/td\u003e\n\u003ctd\u003eup to 0.83 A\u003c\/td\u003e\n\u003ctd\u003eup to 89%\u003c\/td\u003e\n\u003ctd\u003e126 mA (for 12 V input models)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003ctd\u003e3.3 V \/ 5 V \/ 12 V \/ 15 V\u003c\/td\u003e\n\u003ctd\u003eup to 0.66 A\u003c\/td\u003e\n\u003ctd\u003eup to 90%\u003c\/td\u003e\n\u003ctd\u003e120 mA (for 24 V input models)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e48 VDC\u003c\/td\u003e\n\u003ctd\u003e3.3 V \/ 5 V \/ 12 V \/ 15 V\u003c\/td\u003e\n\u003ctd\u003eup to 0.66 A\u003c\/td\u003e\n\u003ctd\u003eup to 90%\u003c\/td\u003e\n\u003ctd\u003e105 mA (for 48 V input models)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental \u0026amp; Safety Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Temperature: -40°C to +100°C\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: -55°C to +125°C\u003c\/li\u003e\n\u003cli\u003eCooling Method: Convection cooled\u003c\/li\u003e\n\u003cli\u003eSafety Approvals: IEC62368-1, EN62368-1, UL62368-1\u003c\/li\u003e\n\u003cli\u003eEMC \u0026amp; Immunity: EN5503, EN61000-4 series, CE Mark LVD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor detailed electrical characteristics and application information, please refer to the \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-xpp\/xpp-jca1024s05.pdf\" target=\"_blank\"\u003edatasheet\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: Datasheet was not processed, please search the internet for the part number JCA1024S05 for more details.\u003c\/em\u003e\u003c\/p\u003e","published_at":"2025-08-12T22:56:36+05:30","created_at":"2025-08-12T22:56:36+05:30","vendor":"Waldom Electonics","type":"DC-DC Converter","tags":["DC","IMPORT_CSV","Isolated","WLDM","XP"],"price":548266,"price_min":548266,"price_max":548266,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50613300068669,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"JCA1024S05","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"JCA1024S05","public_title":null,"options":["Default Title"],"price":548266,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"JCA1024S05","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/JCA1024S05_55983130_6d728155.jpg?v=1755019599"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/JCA1024S05_55983130_6d728155.jpg?v=1755019599","options":["Title"],"media":[{"alt":null,"id":45806740996413,"position":1,"preview_image":{"aspect_ratio":1.0,"height":200,"width":200,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/JCA1024S05_55983130_6d728155.jpg?v=1755019599"},"aspect_ratio":1.0,"height":200,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/JCA1024S05_55983130_6d728155.jpg?v=1755019599","width":200}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eXP POWER JCA1024S05 Isolated DC\/DC Converter - Through Hole, 10W\u003c\/h3\u003e\n\u003cp\u003eIntroducing the \u003cstrong\u003eJCA1024S05\u003c\/strong\u003e isolated DC\/DC converter manufactured by \u003cstrong\u003eXP POWER\u003c\/strong\u003e. Designed for reliable power conversion in industrial and electronic applications, this compact module offers high efficiency and robust performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Details:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e JCA1024S05\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e XP POWER\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e TW (Taiwan)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit of Measure:\u003c\/strong\u003e EA (Each)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e EAR99\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Type:\u003c\/strong\u003e TUBE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDatasheet:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-xpp\/xpp-jca1024s05.pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower Rating: 10 Watts\u003c\/li\u003e\n\u003cli\u003eInput Voltage Range:\n \u003cul\u003e\n \u003cli\u003e5 VDC (4.5-9.0 VDC)\u003c\/li\u003e\n \u003cli\u003e12 VDC (9-18 VDC)\u003c\/li\u003e\n \u003cli\u003e24 VDC (18-36 VDC)\u003c\/li\u003e\n \u003cli\u003e48 VDC (36-75 VDC)\u003c\/li\u003e\n \u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eOutput Voltage Options:\n \u003cul\u003e\n \u003cli\u003e3.3 V, 5 V, 12 V, 15 V (single output)\u003c\/li\u003e\n \u003cli\u003e±5 V, ±12 V, ±15 V (dual output)\u003c\/li\u003e\n \u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eEfficiency up to 90%\u003c\/li\u003e\n\u003cli\u003eIsolation Voltage: 1500 VDC (input to output)\u003c\/li\u003e\n\u003cli\u003eOperating Temperature Range: -40°C to +100°C\u003c\/li\u003e\n\u003cli\u003eCompact Size: 1.0” x 0.8” Metal Package\u003c\/li\u003e\n\u003cli\u003eIndustry Standard Pinout with Through Hole Mounting\u003c\/li\u003e\n\u003cli\u003eHigh Reliability with \u0026gt;950,000 hours MTBF\u003c\/li\u003e\n\u003cli\u003eCompliance: UL, CB, TUV Approvals\u003c\/li\u003e\n\u003cli\u003eOperating Humidity: Up to 95% RH, non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003cth\u003eOutput Voltage\u003c\/th\u003e\n\u003cth\u003eOutput Current\u003c\/th\u003e\n\u003cth\u003eEfficiency\u003c\/th\u003e\n\u003cth\u003eInput Current (at nominal input)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 VDC\u003c\/td\u003e\n\u003ctd\u003e3.3 V \/ 5 V \/ 12 V \/ 15 V\u003c\/td\u003e\n\u003ctd\u003eup to 2.42 A\u003c\/td\u003e\n\u003ctd\u003eup to 86%\u003c\/td\u003e\n\u003ctd\u003e84 mA (for 5 V input models)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12 VDC\u003c\/td\u003e\n\u003ctd\u003e3.3 V \/ 5 V \/ 12 V \/ 15 V\u003c\/td\u003e\n\u003ctd\u003eup to 0.83 A\u003c\/td\u003e\n\u003ctd\u003eup to 89%\u003c\/td\u003e\n\u003ctd\u003e126 mA (for 12 V input models)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003ctd\u003e3.3 V \/ 5 V \/ 12 V \/ 15 V\u003c\/td\u003e\n\u003ctd\u003eup to 0.66 A\u003c\/td\u003e\n\u003ctd\u003eup to 90%\u003c\/td\u003e\n\u003ctd\u003e120 mA (for 24 V input models)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e48 VDC\u003c\/td\u003e\n\u003ctd\u003e3.3 V \/ 5 V \/ 12 V \/ 15 V\u003c\/td\u003e\n\u003ctd\u003eup to 0.66 A\u003c\/td\u003e\n\u003ctd\u003eup to 90%\u003c\/td\u003e\n\u003ctd\u003e105 mA (for 48 V input models)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental \u0026amp; Safety Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Temperature: -40°C to +100°C\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: -55°C to +125°C\u003c\/li\u003e\n\u003cli\u003eCooling Method: Convection cooled\u003c\/li\u003e\n\u003cli\u003eSafety Approvals: IEC62368-1, EN62368-1, UL62368-1\u003c\/li\u003e\n\u003cli\u003eEMC \u0026amp; Immunity: EN5503, EN61000-4 series, CE Mark LVD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor detailed electrical characteristics and application information, please refer to the \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-xpp\/xpp-jca1024s05.pdf\" target=\"_blank\"\u003edatasheet\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: Datasheet was not processed, please search the internet for the part number JCA1024S05 for more details.\u003c\/em\u003e\u003c\/p\u003e"}