XP POWER JHL0312D12 Isolated DC/DC Converter - Through Hole MEDICAL
Enhance your medical electronic applications with the XP POWER JHL0312D12, a high-reliability isolated DC/DC converter designed specifically for medical environments. Manufactured in Taiwan, this 3-watt converter complies with IEC60601-1 standards, ensuring safety and performance in critical medical devices.
Part Number: JHL0312D12
Manufacturer: XP POWER
Country of Origin: TW
Unit of Measure: EA
ECCN: EAR99
Package Type: TUBE
For detailed technical specifications, download the Datasheet.
Product Features
3 Watts power output suitable for medical applications
Reinforced insulation of 4000 VAC, meeting IEC60601-1, 3rd Edition
2 MOPP isolation at 250 VAC for enhanced safety
Low patient leakage current of 2 µA
Compact DIP24 package with through-hole mounting
High efficiency up to 82% depending on model
Auto-recovery hiccup mode for short circuit and overload protection
Designed for natural convection cooling
Operating temperature range: -20°C to +80°C
Meets international medical safety and EMC standards
Model Ratings & Electrical Specifications
Input Voltage
Output Voltage
Output Current
Input Current (No Load / Full Load)
Maximum Capacitive Load
Efficiency
Model Number
10-17 V
5.0 V
600 mA
56 mA / 720 µF
720 µF
76%
JHL0312S05
10-17 V
12.0 V
250 mA
72 mA / 300 µF
300 µF
78%
JHL0312S12
10-17 V
15.0 V
200 mA
67 mA / 240 µF
240 µF
78%
JHL0312S15
10-17 V
±12.0 V
125 mA
43 mA / ±140 µF
±140 µF
81%
JHL0312D12
10-17 V
±15.0 V
100 mA
56 mA / ±120 µF
±120 µF
80%
JHL0312D15
20-30 V
5.0 V
600 mA
38 mA / 720 µF
720 µF
74%
JHL0324S05
20-30 V
12.0 V
250 mA
37 mA / 300 µF
300 µF
78%
JHL0324S12
20-30 V
15.0 V
200 mA
23 mA / 240 µF
240 µF
82%
JHL0324S15
20-30 V
±12.0 V
125 mA
29 mA / ±140 µF
±140 µF
80%
JHL0324D12
20-30 V
±15.0 V
100 mA
42 mA / ±120 µF
±120 µF
80%
JHL0324D15
Environmental & Mechanical Details
Dimensions: 1.25" x 0.18" (31.75mm x 4.57mm)
Weight: approximately 0.04 lbs (20 g)
Pin diameter: 0.02" ±0.002" (0.5mm ±0.05mm)
Pin pitch tolerance: ±0.014" (±0.35mm)
Case tolerance: ±0.02" (±0.5mm)
Operating temperature: -20°C to +80°C
Storage temperature: -40°C to +100°C
Cooling: Natural convection
Humidity: 5% to 90% RH (non-condensing)
Shock & Vibration: Meets EN60068 standards
Safety & EMC Compliance
IEC60601-1, 3rd Edition compliant with reinforced insulation
For more detailed technical information, please refer to the Datasheet. Please note that the datasheet was not processed; search the internet for the part number for additional details.
{"id":10013127901501,"title":"JHL0312D12","handle":"jhl0312d12","description":"\u003ch3\u003eXP POWER JHL0312D12 Isolated DC\/DC Converter - Through Hole MEDICAL\u003c\/h3\u003e\n\u003cp\u003eEnhance your medical electronic applications with the XP POWER JHL0312D12, a high-reliability isolated DC\/DC converter designed specifically for medical environments. Manufactured in Taiwan, this 3-watt converter complies with IEC60601-1 standards, ensuring safety and performance in critical medical devices.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e JHL0312D12\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e XP POWER\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e TW\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit of Measure:\u003c\/strong\u003e EA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e EAR99\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Type:\u003c\/strong\u003e TUBE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor detailed technical specifications, download the \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-xpp\/xpp-jhl0312d12.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3 Watts power output suitable for medical applications\u003c\/li\u003e\n\u003cli\u003eReinforced insulation of 4000 VAC, meeting IEC60601-1, 3rd Edition\u003c\/li\u003e\n\u003cli\u003e2 MOPP isolation at 250 VAC for enhanced safety\u003c\/li\u003e\n\u003cli\u003eLow patient leakage current of 2 µA\u003c\/li\u003e\n\u003cli\u003eCompact DIP24 package with through-hole mounting\u003c\/li\u003e\n\u003cli\u003eHigh efficiency up to 82% depending on model\u003c\/li\u003e\n\u003cli\u003eAuto-recovery hiccup mode for short circuit and overload protection\u003c\/li\u003e\n\u003cli\u003eDesigned for natural convection cooling\u003c\/li\u003e\n\u003cli\u003eOperating temperature range: -20°C to +80°C\u003c\/li\u003e\n\u003cli\u003eMeets international medical safety and EMC standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModel Ratings \u0026amp; Electrical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003cth\u003eOutput Voltage\u003c\/th\u003e\n\u003cth\u003eOutput Current\u003c\/th\u003e\n\u003cth\u003eInput Current (No Load \/ Full Load)\u003c\/th\u003e\n\u003cth\u003eMaximum Capacitive Load\u003c\/th\u003e\n\u003cth\u003eEfficiency\u003c\/th\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e10-17 V\u003c\/td\u003e\n\u003ctd\u003e5.0 V\u003c\/td\u003e\n\u003ctd\u003e600 mA\u003c\/td\u003e\n\u003ctd\u003e56 mA \/ 720 µF\u003c\/td\u003e\n\u003ctd\u003e720 µF\u003c\/td\u003e\n\u003ctd\u003e76%\u003c\/td\u003e\n\u003ctd\u003eJHL0312S05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10-17 V\u003c\/td\u003e\n\u003ctd\u003e12.0 V\u003c\/td\u003e\n\u003ctd\u003e250 mA\u003c\/td\u003e\n\u003ctd\u003e72 mA \/ 300 µF\u003c\/td\u003e\n\u003ctd\u003e300 µF\u003c\/td\u003e\n\u003ctd\u003e78%\u003c\/td\u003e\n\u003ctd\u003eJHL0312S12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10-17 V\u003c\/td\u003e\n\u003ctd\u003e15.0 V\u003c\/td\u003e\n\u003ctd\u003e200 mA\u003c\/td\u003e\n\u003ctd\u003e67 mA \/ 240 µF\u003c\/td\u003e\n\u003ctd\u003e240 µF\u003c\/td\u003e\n\u003ctd\u003e78%\u003c\/td\u003e\n\u003ctd\u003eJHL0312S15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10-17 V\u003c\/td\u003e\n\u003ctd\u003e±12.0 V\u003c\/td\u003e\n\u003ctd\u003e125 mA\u003c\/td\u003e\n\u003ctd\u003e43 mA \/ ±140 µF\u003c\/td\u003e\n\u003ctd\u003e±140 µF\u003c\/td\u003e\n\u003ctd\u003e81%\u003c\/td\u003e\n\u003ctd\u003eJHL0312D12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10-17 V\u003c\/td\u003e\n\u003ctd\u003e±15.0 V\u003c\/td\u003e\n\u003ctd\u003e100 mA\u003c\/td\u003e\n\u003ctd\u003e56 mA \/ ±120 µF\u003c\/td\u003e\n\u003ctd\u003e±120 µF\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003ctd\u003eJHL0312D15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20-30 V\u003c\/td\u003e\n\u003ctd\u003e5.0 V\u003c\/td\u003e\n\u003ctd\u003e600 mA\u003c\/td\u003e\n\u003ctd\u003e38 mA \/ 720 µF\u003c\/td\u003e\n\u003ctd\u003e720 µF\u003c\/td\u003e\n\u003ctd\u003e74%\u003c\/td\u003e\n\u003ctd\u003eJHL0324S05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20-30 V\u003c\/td\u003e\n\u003ctd\u003e12.0 V\u003c\/td\u003e\n\u003ctd\u003e250 mA\u003c\/td\u003e\n\u003ctd\u003e37 mA \/ 300 µF\u003c\/td\u003e\n\u003ctd\u003e300 µF\u003c\/td\u003e\n\u003ctd\u003e78%\u003c\/td\u003e\n\u003ctd\u003eJHL0324S12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20-30 V\u003c\/td\u003e\n\u003ctd\u003e15.0 V\u003c\/td\u003e\n\u003ctd\u003e200 mA\u003c\/td\u003e\n\u003ctd\u003e23 mA \/ 240 µF\u003c\/td\u003e\n\u003ctd\u003e240 µF\u003c\/td\u003e\n\u003ctd\u003e82%\u003c\/td\u003e\n\u003ctd\u003eJHL0324S15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20-30 V\u003c\/td\u003e\n\u003ctd\u003e±12.0 V\u003c\/td\u003e\n\u003ctd\u003e125 mA\u003c\/td\u003e\n\u003ctd\u003e29 mA \/ ±140 µF\u003c\/td\u003e\n\u003ctd\u003e±140 µF\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003ctd\u003eJHL0324D12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20-30 V\u003c\/td\u003e\n\u003ctd\u003e±15.0 V\u003c\/td\u003e\n\u003ctd\u003e100 mA\u003c\/td\u003e\n\u003ctd\u003e42 mA \/ ±120 µF\u003c\/td\u003e\n\u003ctd\u003e±120 µF\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003ctd\u003eJHL0324D15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEnvironmental \u0026amp; Mechanical Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDimensions: 1.25\" x 0.18\" (31.75mm x 4.57mm)\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.04 lbs (20 g)\u003c\/li\u003e\n\u003cli\u003ePin diameter: 0.02\" ±0.002\" (0.5mm ±0.05mm)\u003c\/li\u003e\n\u003cli\u003ePin pitch tolerance: ±0.014\" (±0.35mm)\u003c\/li\u003e\n\u003cli\u003eCase tolerance: ±0.02\" (±0.5mm)\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -20°C to +80°C\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40°C to +100°C\u003c\/li\u003e\n\u003cli\u003eCooling: Natural convection\u003c\/li\u003e\n\u003cli\u003eHumidity: 5% to 90% RH (non-condensing)\u003c\/li\u003e\n\u003cli\u003eShock \u0026amp; Vibration: Meets EN60068 standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSafety \u0026amp; EMC Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIEC60601-1, 3rd Edition compliant with reinforced insulation\u003c\/li\u003e\n\u003cli\u003ePatient leakage current: 2 µA\u003c\/li\u003e\n\u003cli\u003eEMC emissions: EN55011 Level A\u003c\/li\u003e\n\u003cli\u003eImmunity: IEC61000-4 series standards\u003c\/li\u003e\n\u003cli\u003eCertifications: UL, IEC60601-1, CSA-22.2 No.60601-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor more detailed technical information, please refer to the \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-xpp\/xpp-jhl0312d12.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e. Please note that the datasheet was not processed; search the internet for the part number for additional details.\u003c\/p\u003e","published_at":"2025-08-10T13:29:11+05:30","created_at":"2025-08-10T13:29:11+05:30","vendor":"Waldom Electonics","type":"DC-DC Converter","tags":["DC","IMPORT_CSV","Isolated","WLDM","XP"],"price":532328,"price_min":532328,"price_max":532328,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50577501225277,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"JHL0312D12","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"JHL0312D12","public_title":null,"options":["Default Title"],"price":532328,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"JHL0312D12","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/JHL0312D12_55939654_a3cc9240.jpg?v=1754812754"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/JHL0312D12_55939654_a3cc9240.jpg?v=1754812754","options":["Title"],"media":[{"alt":null,"id":45760653951293,"position":1,"preview_image":{"aspect_ratio":1.0,"height":200,"width":200,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/JHL0312D12_55939654_a3cc9240.jpg?v=1754812754"},"aspect_ratio":1.0,"height":200,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/JHL0312D12_55939654_a3cc9240.jpg?v=1754812754","width":200}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eXP POWER JHL0312D12 Isolated DC\/DC Converter - Through Hole MEDICAL\u003c\/h3\u003e\n\u003cp\u003eEnhance your medical electronic applications with the XP POWER JHL0312D12, a high-reliability isolated DC\/DC converter designed specifically for medical environments. Manufactured in Taiwan, this 3-watt converter complies with IEC60601-1 standards, ensuring safety and performance in critical medical devices.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e JHL0312D12\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e XP POWER\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e TW\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit of Measure:\u003c\/strong\u003e EA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e EAR99\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Type:\u003c\/strong\u003e TUBE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor detailed technical specifications, download the \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-xpp\/xpp-jhl0312d12.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3 Watts power output suitable for medical applications\u003c\/li\u003e\n\u003cli\u003eReinforced insulation of 4000 VAC, meeting IEC60601-1, 3rd Edition\u003c\/li\u003e\n\u003cli\u003e2 MOPP isolation at 250 VAC for enhanced safety\u003c\/li\u003e\n\u003cli\u003eLow patient leakage current of 2 µA\u003c\/li\u003e\n\u003cli\u003eCompact DIP24 package with through-hole mounting\u003c\/li\u003e\n\u003cli\u003eHigh efficiency up to 82% depending on model\u003c\/li\u003e\n\u003cli\u003eAuto-recovery hiccup mode for short circuit and overload protection\u003c\/li\u003e\n\u003cli\u003eDesigned for natural convection cooling\u003c\/li\u003e\n\u003cli\u003eOperating temperature range: -20°C to +80°C\u003c\/li\u003e\n\u003cli\u003eMeets international medical safety and EMC standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModel Ratings \u0026amp; Electrical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003cth\u003eOutput Voltage\u003c\/th\u003e\n\u003cth\u003eOutput Current\u003c\/th\u003e\n\u003cth\u003eInput Current (No Load \/ Full Load)\u003c\/th\u003e\n\u003cth\u003eMaximum Capacitive Load\u003c\/th\u003e\n\u003cth\u003eEfficiency\u003c\/th\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e10-17 V\u003c\/td\u003e\n\u003ctd\u003e5.0 V\u003c\/td\u003e\n\u003ctd\u003e600 mA\u003c\/td\u003e\n\u003ctd\u003e56 mA \/ 720 µF\u003c\/td\u003e\n\u003ctd\u003e720 µF\u003c\/td\u003e\n\u003ctd\u003e76%\u003c\/td\u003e\n\u003ctd\u003eJHL0312S05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10-17 V\u003c\/td\u003e\n\u003ctd\u003e12.0 V\u003c\/td\u003e\n\u003ctd\u003e250 mA\u003c\/td\u003e\n\u003ctd\u003e72 mA \/ 300 µF\u003c\/td\u003e\n\u003ctd\u003e300 µF\u003c\/td\u003e\n\u003ctd\u003e78%\u003c\/td\u003e\n\u003ctd\u003eJHL0312S12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10-17 V\u003c\/td\u003e\n\u003ctd\u003e15.0 V\u003c\/td\u003e\n\u003ctd\u003e200 mA\u003c\/td\u003e\n\u003ctd\u003e67 mA \/ 240 µF\u003c\/td\u003e\n\u003ctd\u003e240 µF\u003c\/td\u003e\n\u003ctd\u003e78%\u003c\/td\u003e\n\u003ctd\u003eJHL0312S15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10-17 V\u003c\/td\u003e\n\u003ctd\u003e±12.0 V\u003c\/td\u003e\n\u003ctd\u003e125 mA\u003c\/td\u003e\n\u003ctd\u003e43 mA \/ ±140 µF\u003c\/td\u003e\n\u003ctd\u003e±140 µF\u003c\/td\u003e\n\u003ctd\u003e81%\u003c\/td\u003e\n\u003ctd\u003eJHL0312D12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10-17 V\u003c\/td\u003e\n\u003ctd\u003e±15.0 V\u003c\/td\u003e\n\u003ctd\u003e100 mA\u003c\/td\u003e\n\u003ctd\u003e56 mA \/ ±120 µF\u003c\/td\u003e\n\u003ctd\u003e±120 µF\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003ctd\u003eJHL0312D15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20-30 V\u003c\/td\u003e\n\u003ctd\u003e5.0 V\u003c\/td\u003e\n\u003ctd\u003e600 mA\u003c\/td\u003e\n\u003ctd\u003e38 mA \/ 720 µF\u003c\/td\u003e\n\u003ctd\u003e720 µF\u003c\/td\u003e\n\u003ctd\u003e74%\u003c\/td\u003e\n\u003ctd\u003eJHL0324S05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20-30 V\u003c\/td\u003e\n\u003ctd\u003e12.0 V\u003c\/td\u003e\n\u003ctd\u003e250 mA\u003c\/td\u003e\n\u003ctd\u003e37 mA \/ 300 µF\u003c\/td\u003e\n\u003ctd\u003e300 µF\u003c\/td\u003e\n\u003ctd\u003e78%\u003c\/td\u003e\n\u003ctd\u003eJHL0324S12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20-30 V\u003c\/td\u003e\n\u003ctd\u003e15.0 V\u003c\/td\u003e\n\u003ctd\u003e200 mA\u003c\/td\u003e\n\u003ctd\u003e23 mA \/ 240 µF\u003c\/td\u003e\n\u003ctd\u003e240 µF\u003c\/td\u003e\n\u003ctd\u003e82%\u003c\/td\u003e\n\u003ctd\u003eJHL0324S15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20-30 V\u003c\/td\u003e\n\u003ctd\u003e±12.0 V\u003c\/td\u003e\n\u003ctd\u003e125 mA\u003c\/td\u003e\n\u003ctd\u003e29 mA \/ ±140 µF\u003c\/td\u003e\n\u003ctd\u003e±140 µF\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003ctd\u003eJHL0324D12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20-30 V\u003c\/td\u003e\n\u003ctd\u003e±15.0 V\u003c\/td\u003e\n\u003ctd\u003e100 mA\u003c\/td\u003e\n\u003ctd\u003e42 mA \/ ±120 µF\u003c\/td\u003e\n\u003ctd\u003e±120 µF\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003ctd\u003eJHL0324D15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEnvironmental \u0026amp; Mechanical Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDimensions: 1.25\" x 0.18\" (31.75mm x 4.57mm)\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.04 lbs (20 g)\u003c\/li\u003e\n\u003cli\u003ePin diameter: 0.02\" ±0.002\" (0.5mm ±0.05mm)\u003c\/li\u003e\n\u003cli\u003ePin pitch tolerance: ±0.014\" (±0.35mm)\u003c\/li\u003e\n\u003cli\u003eCase tolerance: ±0.02\" (±0.5mm)\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -20°C to +80°C\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40°C to +100°C\u003c\/li\u003e\n\u003cli\u003eCooling: Natural convection\u003c\/li\u003e\n\u003cli\u003eHumidity: 5% to 90% RH (non-condensing)\u003c\/li\u003e\n\u003cli\u003eShock \u0026amp; Vibration: Meets EN60068 standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSafety \u0026amp; EMC Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIEC60601-1, 3rd Edition compliant with reinforced insulation\u003c\/li\u003e\n\u003cli\u003ePatient leakage current: 2 µA\u003c\/li\u003e\n\u003cli\u003eEMC emissions: EN55011 Level A\u003c\/li\u003e\n\u003cli\u003eImmunity: IEC61000-4 series standards\u003c\/li\u003e\n\u003cli\u003eCertifications: UL, IEC60601-1, CSA-22.2 No.60601-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor more detailed technical information, please refer to the \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-xpp\/xpp-jhl0312d12.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e. Please note that the datasheet was not processed; search the internet for the part number for additional details.\u003c\/p\u003e"}