XP POWER RDE03110S12 Through Hole DC-DC Converter 3W 4:1 Input Rail
The RDE03110S12 is a high-performance, isolated DC-DC converter manufactured by XP POWER. Designed for demanding railway and industrial applications, this compact through-hole power module offers reliable power conversion with robust construction and comprehensive safety features.
50 VDC (1 s), 100 VDC (48 V nominal), 170 VDC (72/110 V nominal)
Undervoltage Lockout
Off at <7.5 V (24 V), <16.0 V (48 V), <37.0 V (72/110 V)
Output Voltage
5 V, 12 V, 15 V, 30 V (see models and ratings)
Output Power
3 W
Efficiency
Up to 84%
Isolation Voltage
3000 VAC (60 s reinforced)
Ripple & Noise
50/75 mV pk-pk (measured at 20 MHz bandwidth)
Transient Response
±3% to ±5% deviation, recovery within 250 μs for 25% load change
Maximum Capacitive Load
See models and ratings table
Operating Temperature
-40°C to +105°C
Humidity
Up to 95% RH (non-condensing)
Safety and Compliance
Meets IEC62368-1 and UL/cUL62368-1 standards for information technology equipment
Complies with IEC60571 and EN50155 for railway applications
Electromagnetic Compatibility (EMC): EN55032 Class A, EN50121-3-2
Immunity standards include EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8
Environmental & Mechanical
Operating Temperature: -40°C to +105°C with derating
Storage Temperature: -50°C to +125°C
Shock & Vibration: IEC/EN 61373
Case Material: Non-conductive UL94V-0 rated plastic
Weight: Approximately 15.4 grams
Additional Information
This DC-DC converter is designed for demanding railway and industrial environments, offering high reliability, safety, and efficiency. Its reinforced isolation and wide input range make it suitable for various power supply configurations.
For more detailed specifications, download the datasheet. Please note, the datasheet was not processed; search the internet for the part number for more details.
Use left/right arrows to navigate the slideshow or swipe left/right if using a mobile device
Choosing a selection results in a full page refresh.
Press the space key then arrow keys to make a selection.
Shopping Cart
{"id":10013386375485,"title":"RDE03110S12","handle":"rde03110s12","description":"\u003ch3\u003eXP POWER RDE03110S12 Through Hole DC-DC Converter 3W 4:1 Input Rail\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eRDE03110S12\u003c\/strong\u003e is a high-performance, isolated DC-DC converter manufactured by \u003cstrong\u003eXP POWER\u003c\/strong\u003e. Designed for demanding railway and industrial applications, this compact through-hole power module offers reliable power conversion with robust construction and comprehensive safety features.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e RDE03110S12\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e XP POWER\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Taiwan (TW)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit of Measure:\u003c\/strong\u003e Each (EA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e EAR99\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Type:\u003c\/strong\u003e Tube\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDatasheet:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-xpp\/xpp-rde03110s12.pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3 Watts power output with high efficiency (up to 84%)\u003c\/li\u003e\n\u003cli\u003eWide 4:1 input voltage range covering 24 VDC, 48 VDC, and 72\/110 VDC rail applications\u003c\/li\u003e\n\u003cli\u003eReinforced 3000 VAC isolation between input and output\u003c\/li\u003e\n\u003cli\u003eOperating temperature range from -40°C to +105°C with full power capability at 80°C\u003c\/li\u003e\n\u003cli\u003eNo external filter required, simplifying system design\u003c\/li\u003e\n\u003cli\u003eCompliance with EN50155, IEC60571, and EN50121-3-2 standards for railway and industrial environments\u003c\/li\u003e\n\u003cli\u003eContinuous short circuit protection with auto-recovery (hiccup mode)\u003c\/li\u003e\n\u003cli\u003eCompact and lightweight design with a power density of 6.38 W\/in³\u003c\/li\u003e\n\u003cli\u003eDurable non-conductive UL94V-0 rated case material\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e9-36 VDC, 18-75 VDC, 40-160 VDC (nominal 24 V, 48 V, 72\/110 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Surge Voltage\u003c\/td\u003e\n\u003ctd\u003e50 VDC (1 s), 100 VDC (48 V nominal), 170 VDC (72\/110 V nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUndervoltage Lockout\u003c\/td\u003e\n\u003ctd\u003eOff at \u0026lt;7.5 V (24 V), \u0026lt;16.0 V (48 V), \u0026lt;37.0 V (72\/110 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e5 V, 12 V, 15 V, 30 V (see models and ratings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power\u003c\/td\u003e\n\u003ctd\u003e3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eUp to 84%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e3000 VAC (60 s reinforced)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRipple \u0026amp; Noise\u003c\/td\u003e\n\u003ctd\u003e50\/75 mV pk-pk (measured at 20 MHz bandwidth)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransient Response\u003c\/td\u003e\n\u003ctd\u003e±3% to ±5% deviation, recovery within 250 μs for 25% load change\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Capacitive Load\u003c\/td\u003e\n\u003ctd\u003eSee models and ratings table\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +105°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003eUp to 95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSafety and Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMeets IEC62368-1 and UL\/cUL62368-1 standards for information technology equipment\u003c\/li\u003e\n\u003cli\u003eComplies with IEC60571 and EN50155 for railway applications\u003c\/li\u003e\n\u003cli\u003eElectromagnetic Compatibility (EMC): EN55032 Class A, EN50121-3-2\u003c\/li\u003e\n\u003cli\u003eImmunity standards include EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental \u0026amp; Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Temperature: -40°C to +105°C with derating\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: -50°C to +125°C\u003c\/li\u003e\n\u003cli\u003eShock \u0026amp; Vibration: IEC\/EN 61373\u003c\/li\u003e\n\u003cli\u003eCase Material: Non-conductive UL94V-0 rated plastic\u003c\/li\u003e\n\u003cli\u003eWeight: Approximately 15.4 grams\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdditional Information\u003c\/h3\u003e\n\u003cp\u003eThis DC-DC converter is designed for demanding railway and industrial environments, offering high reliability, safety, and efficiency. Its reinforced isolation and wide input range make it suitable for various power supply configurations.\u003c\/p\u003e\n\u003cp\u003eFor more detailed specifications, download the \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-xpp\/xpp-rde03110s12.pdf\" target=\"_blank\"\u003edatasheet\u003c\/a\u003e. Please note, the datasheet was not processed; search the internet for the part number for more details.\u003c\/p\u003e","published_at":"2025-08-10T15:58:06+05:30","created_at":"2025-08-10T15:58:06+05:30","vendor":"Waldom Electonics","type":"DC-DC Converter","tags":["3W","DC","IMPORT_CSV","Isolated","Rail","WLDM","XP"],"price":597050,"price_min":597050,"price_max":597050,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50578298274109,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"RDE03110S12","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"RDE03110S12","public_title":null,"options":["Default Title"],"price":597050,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"RDE03110S12","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/RDE03110S12_55983737_40277f2b.jpg?v=1754821689"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/RDE03110S12_55983737_40277f2b.jpg?v=1754821689","options":["Title"],"media":[{"alt":null,"id":45762459828541,"position":1,"preview_image":{"aspect_ratio":1.0,"height":200,"width":200,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/RDE03110S12_55983737_40277f2b.jpg?v=1754821689"},"aspect_ratio":1.0,"height":200,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/RDE03110S12_55983737_40277f2b.jpg?v=1754821689","width":200}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eXP POWER RDE03110S12 Through Hole DC-DC Converter 3W 4:1 Input Rail\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eRDE03110S12\u003c\/strong\u003e is a high-performance, isolated DC-DC converter manufactured by \u003cstrong\u003eXP POWER\u003c\/strong\u003e. Designed for demanding railway and industrial applications, this compact through-hole power module offers reliable power conversion with robust construction and comprehensive safety features.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e RDE03110S12\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e XP POWER\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Taiwan (TW)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit of Measure:\u003c\/strong\u003e Each (EA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e EAR99\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Type:\u003c\/strong\u003e Tube\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDatasheet:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-xpp\/xpp-rde03110s12.pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3 Watts power output with high efficiency (up to 84%)\u003c\/li\u003e\n\u003cli\u003eWide 4:1 input voltage range covering 24 VDC, 48 VDC, and 72\/110 VDC rail applications\u003c\/li\u003e\n\u003cli\u003eReinforced 3000 VAC isolation between input and output\u003c\/li\u003e\n\u003cli\u003eOperating temperature range from -40°C to +105°C with full power capability at 80°C\u003c\/li\u003e\n\u003cli\u003eNo external filter required, simplifying system design\u003c\/li\u003e\n\u003cli\u003eCompliance with EN50155, IEC60571, and EN50121-3-2 standards for railway and industrial environments\u003c\/li\u003e\n\u003cli\u003eContinuous short circuit protection with auto-recovery (hiccup mode)\u003c\/li\u003e\n\u003cli\u003eCompact and lightweight design with a power density of 6.38 W\/in³\u003c\/li\u003e\n\u003cli\u003eDurable non-conductive UL94V-0 rated case material\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e9-36 VDC, 18-75 VDC, 40-160 VDC (nominal 24 V, 48 V, 72\/110 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Surge Voltage\u003c\/td\u003e\n\u003ctd\u003e50 VDC (1 s), 100 VDC (48 V nominal), 170 VDC (72\/110 V nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUndervoltage Lockout\u003c\/td\u003e\n\u003ctd\u003eOff at \u0026lt;7.5 V (24 V), \u0026lt;16.0 V (48 V), \u0026lt;37.0 V (72\/110 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e5 V, 12 V, 15 V, 30 V (see models and ratings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power\u003c\/td\u003e\n\u003ctd\u003e3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eUp to 84%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e3000 VAC (60 s reinforced)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRipple \u0026amp; Noise\u003c\/td\u003e\n\u003ctd\u003e50\/75 mV pk-pk (measured at 20 MHz bandwidth)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransient Response\u003c\/td\u003e\n\u003ctd\u003e±3% to ±5% deviation, recovery within 250 μs for 25% load change\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Capacitive Load\u003c\/td\u003e\n\u003ctd\u003eSee models and ratings table\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +105°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003eUp to 95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSafety and Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMeets IEC62368-1 and UL\/cUL62368-1 standards for information technology equipment\u003c\/li\u003e\n\u003cli\u003eComplies with IEC60571 and EN50155 for railway applications\u003c\/li\u003e\n\u003cli\u003eElectromagnetic Compatibility (EMC): EN55032 Class A, EN50121-3-2\u003c\/li\u003e\n\u003cli\u003eImmunity standards include EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental \u0026amp; Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Temperature: -40°C to +105°C with derating\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: -50°C to +125°C\u003c\/li\u003e\n\u003cli\u003eShock \u0026amp; Vibration: IEC\/EN 61373\u003c\/li\u003e\n\u003cli\u003eCase Material: Non-conductive UL94V-0 rated plastic\u003c\/li\u003e\n\u003cli\u003eWeight: Approximately 15.4 grams\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdditional Information\u003c\/h3\u003e\n\u003cp\u003eThis DC-DC converter is designed for demanding railway and industrial environments, offering high reliability, safety, and efficiency. Its reinforced isolation and wide input range make it suitable for various power supply configurations.\u003c\/p\u003e\n\u003cp\u003eFor more detailed specifications, download the \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-xpp\/xpp-rde03110s12.pdf\" target=\"_blank\"\u003edatasheet\u003c\/a\u003e. Please note, the datasheet was not processed; search the internet for the part number for more details.\u003c\/p\u003e"}