Introducing the PRC: SNS Sealed Fixed Thermostat with Leads, manufactured by SENSTA PRESSURE & TEMP in China (COO: CN). This high-reliability sensor is designed for precise temperature control in various applications. Packaged in a convenient box, it features a 3/8" tube mounting connection and complies with RoHS standards (RoHs: Y). The product's ECCN classification is EAR99, making it suitable for a wide range of industrial environments.
Product Features
Automatic reset for reliable operation
Compact and easy to mount
Fast thermal response for accurate temperature control
Innovative dry seal design protects against moisture and dust ingress
High temperature rating up to 275ºF (135ºC)
Long cycle life of 100,000 cycles
Suitable for electrical loads up to 10A @ 240 VAC
Specifications
Electrical Ratings
Cycles Amps Agency Volts FLA LRA VA x1000 (resistive)
120 Vac
5.8 34.8 10 125 (USA, Canada)
240 Vac
2.9 17.4 10 125
Other Ratings
UL 100 120 Vac 10A, 240 Vac 10A; ENEC 30Vdc 16A
Operating Temperature: -20 to 135ºC (-4 to 275ºF)
Ambient Temperature: -40ºC to maximum wire lead insulation temperature
Temperature Rating: PVC - 105ºC, XLP - 125ºC
Minimum Nominal Temperature Differential: 8ºC (15ºF)
Dielectric Strength: 750 Vrms (terminals to case), 1500 Vrms (case)
Wire Leads: 18 AWG or 16 AWG, suitable for 105°C PVC or 125°C XLPE insulation
Physical Dimensions & Mounting
Dimensions are provided in millimeters and inches. Multiple mounting clips are available for various tube sizes, including 3/8" tubes, with options for rotation and additional clip styles.
Certifications & Approvals
Agency
File/Report Number
Category
UL (USA)
SA995
Category SDFY2
UL (Canada)
SA995
Category SDFY8
DEKRA (ENEC)
2014531.16
EN60730-1, EN60730-2-9
DEKRA (IECEx)
21862646400
IEC60079-0, IEC60079-15, IEC60529
Important Notices
These devices are intended for use by Original Equipment Manufacturers and are not suitable as service components. They should not be submerged in liquids, used in explosion-proof environments, or in applications with flammable vapors, gases, or dust. Proper end-of-life protection must be implemented to prevent circuit failure. Follow all mounting and safety instructions to avoid injury or damage.
Additional Information
For detailed technical specifications and application guidance, please refer to the datasheet.
Note: Datasheet was not processed, please search the internet for the part number 3NT01L-H7925 for more details.
Use left/right arrows to navigate the slideshow or swipe left/right if using a mobile device
Choosing a selection results in a full page refresh.
Press the space key then arrow keys to make a selection.
Shopping Cart
{"id":10019374170429,"title":"3NT01L-H7925","handle":"3nt01l-h7925","description":"\u003ch3\u003eSealed Fixed Thermostat with Leads - 3\/8\" Tube M\u003c\/h3\u003e\n\u003cp\u003eIntroducing the \u003cstrong\u003ePRC: SNS\u003c\/strong\u003e Sealed Fixed Thermostat with Leads, manufactured by \u003cstrong\u003eSENSTA PRESSURE \u0026amp; TEMP\u003c\/strong\u003e in China (COO: CN). This high-reliability sensor is designed for precise temperature control in various applications. Packaged in a convenient box, it features a 3\/8\" tube mounting connection and complies with RoHS standards (RoHs: Y). The product's ECCN classification is EAR99, making it suitable for a wide range of industrial environments.\u003c\/p\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eAutomatic reset for reliable operation\u003c\/li\u003e\n \u003cli\u003eCompact and easy to mount\u003c\/li\u003e\n \u003cli\u003eFast thermal response for accurate temperature control\u003c\/li\u003e\n \u003cli\u003eInnovative dry seal design protects against moisture and dust ingress\u003c\/li\u003e\n \u003cli\u003eHigh temperature rating up to 275ºF (135ºC)\u003c\/li\u003e\n \u003cli\u003eLong cycle life of 100,000 cycles\u003c\/li\u003e\n \u003cli\u003eSuitable for electrical loads up to 10A @ 240 VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n \u003cth\u003eElectrical Ratings\u003c\/th\u003e\n \u003ctd\u003eCycles Amps Agency Volts FLA LRA VA x1000 (resistive)\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e120 Vac\u003c\/td\u003e\n \u003ctd\u003e5.8 34.8 10 125 (USA, Canada)\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e240 Vac\u003c\/td\u003e\n \u003ctd\u003e2.9 17.4 10 125\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eOther Ratings\u003c\/td\u003e\n \u003ctd\u003eUL 100 120 Vac 10A, 240 Vac 10A; ENEC 30Vdc 16A\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cul\u003e\n \u003cli\u003eOperating Temperature: -20 to 135ºC (-4 to 275ºF)\u003c\/li\u003e\n \u003cli\u003eAmbient Temperature: -40ºC to maximum wire lead insulation temperature\u003c\/li\u003e\n \u003cli\u003eTemperature Rating: PVC - 105ºC, XLP - 125ºC\u003c\/li\u003e\n \u003cli\u003eMinimum Nominal Temperature Differential: 8ºC (15ºF)\u003c\/li\u003e\n \u003cli\u003eDielectric Strength: 750 Vrms (terminals to case), 1500 Vrms (case)\u003c\/li\u003e\n \u003cli\u003eWire Leads: 18 AWG or 16 AWG, suitable for 105°C PVC or 125°C XLPE insulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Dimensions \u0026amp; Mounting\u003c\/h3\u003e\n\u003cp\u003eDimensions are provided in millimeters and inches. Multiple mounting clips are available for various tube sizes, including 3\/8\" tubes, with options for rotation and additional clip styles.\u003c\/p\u003e\n\u003ch3\u003eCertifications \u0026amp; Approvals\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n \u003cth\u003eAgency\u003c\/th\u003e\n \u003cth\u003eFile\/Report Number\u003c\/th\u003e\n \u003cth\u003eCategory\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eUL (USA)\u003c\/td\u003e\n \u003ctd\u003eSA995\u003c\/td\u003e\n \u003ctd\u003eCategory SDFY2\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eUL (Canada)\u003c\/td\u003e\n \u003ctd\u003eSA995\u003c\/td\u003e\n \u003ctd\u003eCategory SDFY8\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eDEKRA (ENEC)\u003c\/td\u003e\n \u003ctd\u003e2014531.16\u003c\/td\u003e\n \u003ctd\u003eEN60730-1, EN60730-2-9\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eDEKRA (IECEx)\u003c\/td\u003e\n \u003ctd\u003e21862646400\u003c\/td\u003e\n \u003ctd\u003eIEC60079-0, IEC60079-15, IEC60529\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eImportant Notices\u003c\/h3\u003e\n\u003cp\u003eThese devices are intended for use by Original Equipment Manufacturers and are not suitable as service components. They should not be submerged in liquids, used in explosion-proof environments, or in applications with flammable vapors, gases, or dust. Proper end-of-life protection must be implemented to prevent circuit failure. Follow all mounting and safety instructions to avoid injury or damage.\u003c\/p\u003e\n\u003ch3\u003eAdditional Information\u003c\/h3\u003e\n\u003cp\u003eFor detailed technical specifications and application guidance, please refer to the \u003ca href=\"https:\/\/www.waldomapac.com\/productfiles\/mf-sns\/ta-3nt20series-fixed20temperature20thermostats-datasheet.pdf\" target=\"_blank\"\u003edatasheet\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: Datasheet was not processed, please search the internet for the part number 3NT01L-H7925 for more details.\u003c\/em\u003e\u003c\/p\u003e","published_at":"2025-08-11T14:01:26+05:30","created_at":"2025-08-11T14:01:26+05:30","vendor":"Waldom Electonics","type":"Sensors\/Transducers","tags":["IMPORT_CSV","WLDM"],"price":193750,"price_min":193750,"price_max":193750,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50606824096061,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"3NT01L-H7925","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"3NT01L-H7925","public_title":null,"options":["Default Title"],"price":193750,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"3NT01L-H7925","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/50377267.jpg?v=1754901089"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/50377267.jpg?v=1754901089","options":["Title"],"media":[{"alt":null,"id":45781221212477,"position":1,"preview_image":{"aspect_ratio":1.0,"height":420,"width":420,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/50377267.jpg?v=1754901089"},"aspect_ratio":1.0,"height":420,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/50377267.jpg?v=1754901089","width":420}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eSealed Fixed Thermostat with Leads - 3\/8\" Tube M\u003c\/h3\u003e\n\u003cp\u003eIntroducing the \u003cstrong\u003ePRC: SNS\u003c\/strong\u003e Sealed Fixed Thermostat with Leads, manufactured by \u003cstrong\u003eSENSTA PRESSURE \u0026amp; TEMP\u003c\/strong\u003e in China (COO: CN). This high-reliability sensor is designed for precise temperature control in various applications. Packaged in a convenient box, it features a 3\/8\" tube mounting connection and complies with RoHS standards (RoHs: Y). The product's ECCN classification is EAR99, making it suitable for a wide range of industrial environments.\u003c\/p\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eAutomatic reset for reliable operation\u003c\/li\u003e\n \u003cli\u003eCompact and easy to mount\u003c\/li\u003e\n \u003cli\u003eFast thermal response for accurate temperature control\u003c\/li\u003e\n \u003cli\u003eInnovative dry seal design protects against moisture and dust ingress\u003c\/li\u003e\n \u003cli\u003eHigh temperature rating up to 275ºF (135ºC)\u003c\/li\u003e\n \u003cli\u003eLong cycle life of 100,000 cycles\u003c\/li\u003e\n \u003cli\u003eSuitable for electrical loads up to 10A @ 240 VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n \u003cth\u003eElectrical Ratings\u003c\/th\u003e\n \u003ctd\u003eCycles Amps Agency Volts FLA LRA VA x1000 (resistive)\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e120 Vac\u003c\/td\u003e\n \u003ctd\u003e5.8 34.8 10 125 (USA, Canada)\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e240 Vac\u003c\/td\u003e\n \u003ctd\u003e2.9 17.4 10 125\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eOther Ratings\u003c\/td\u003e\n \u003ctd\u003eUL 100 120 Vac 10A, 240 Vac 10A; ENEC 30Vdc 16A\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cul\u003e\n \u003cli\u003eOperating Temperature: -20 to 135ºC (-4 to 275ºF)\u003c\/li\u003e\n \u003cli\u003eAmbient Temperature: -40ºC to maximum wire lead insulation temperature\u003c\/li\u003e\n \u003cli\u003eTemperature Rating: PVC - 105ºC, XLP - 125ºC\u003c\/li\u003e\n \u003cli\u003eMinimum Nominal Temperature Differential: 8ºC (15ºF)\u003c\/li\u003e\n \u003cli\u003eDielectric Strength: 750 Vrms (terminals to case), 1500 Vrms (case)\u003c\/li\u003e\n \u003cli\u003eWire Leads: 18 AWG or 16 AWG, suitable for 105°C PVC or 125°C XLPE insulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Dimensions \u0026amp; Mounting\u003c\/h3\u003e\n\u003cp\u003eDimensions are provided in millimeters and inches. Multiple mounting clips are available for various tube sizes, including 3\/8\" tubes, with options for rotation and additional clip styles.\u003c\/p\u003e\n\u003ch3\u003eCertifications \u0026amp; Approvals\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n \u003cth\u003eAgency\u003c\/th\u003e\n \u003cth\u003eFile\/Report Number\u003c\/th\u003e\n \u003cth\u003eCategory\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eUL (USA)\u003c\/td\u003e\n \u003ctd\u003eSA995\u003c\/td\u003e\n \u003ctd\u003eCategory SDFY2\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eUL (Canada)\u003c\/td\u003e\n \u003ctd\u003eSA995\u003c\/td\u003e\n \u003ctd\u003eCategory SDFY8\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eDEKRA (ENEC)\u003c\/td\u003e\n \u003ctd\u003e2014531.16\u003c\/td\u003e\n \u003ctd\u003eEN60730-1, EN60730-2-9\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eDEKRA (IECEx)\u003c\/td\u003e\n \u003ctd\u003e21862646400\u003c\/td\u003e\n \u003ctd\u003eIEC60079-0, IEC60079-15, IEC60529\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eImportant Notices\u003c\/h3\u003e\n\u003cp\u003eThese devices are intended for use by Original Equipment Manufacturers and are not suitable as service components. They should not be submerged in liquids, used in explosion-proof environments, or in applications with flammable vapors, gases, or dust. Proper end-of-life protection must be implemented to prevent circuit failure. Follow all mounting and safety instructions to avoid injury or damage.\u003c\/p\u003e\n\u003ch3\u003eAdditional Information\u003c\/h3\u003e\n\u003cp\u003eFor detailed technical specifications and application guidance, please refer to the \u003ca href=\"https:\/\/www.waldomapac.com\/productfiles\/mf-sns\/ta-3nt20series-fixed20temperature20thermostats-datasheet.pdf\" target=\"_blank\"\u003edatasheet\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: Datasheet was not processed, please search the internet for the part number 3NT01L-H7925 for more details.\u003c\/em\u003e\u003c\/p\u003e"}
Team is suppotive and solves all the queries .
The product is good and will surely help me in my project...looking forward for more trades with think robotics.