ADVANCED ENERGY / SL POWER / CONDOR CINT1150A2406K01 AC-DC Regulated Power Supply Module 150W
Upgrade your industrial power solutions with the high-performance CINT1150A2406K01 AC-DC power supply module from ADVANCED ENERGY / SL POWER / CONDOR. Designed for demanding applications, this 150W switching power supply offers reliable, efficient power conversion in a compact form factor.
Product Features
High-density 2” x 4” x 1.3” open-frame design suitable for 1U applications
Universal input voltage range of 90-264 VAC for global compatibility
Wide operating temperature from -10°C to +70°C, with full rated power up to +50°C
Power Fail and DC OK signals for system monitoring
Approved to CSA, EN, IEC, UL60950-1, 2nd Edition safety standards
RoHS compliant for environmentally responsible design
Hiccup mode overload protection and short circuit protection
High efficiency rated at 88% typical at 115VAC
Multiple safety and EMC compliance standards including EN55011/22, FCC, EN61000 series
Technical Specifications
Parameter
Details
Output Power
150W continuous with 200 LFM airflow; 100W convection cooled
Power Fail: goes LOW with a 5ms warning before power loss
DC OK: open collector signal, HIGH 100-500ms after regulation
Connector
Details
Input
Molex 09-50-3031 (Pins: 08-52-0072)
Ground
Molex 01-90020009
DC Output
AMP 640250-6 (Pins: 640252-1)
Signals
Molex 1375820-2 (Pins: 1375819)
Certifications & Compliance
EN55011/22 Class B (Conducted Emissions)
EN55011/22 Class A (Radiated Emissions)
EN61000-4 series immunity standards
FCC Part 15, Subpart B, Class A/B
IEC/CSA/UL safety standards
For more detailed specifications and technical information, please refer to the datasheet. Datasheet was not processed please search the internet for the part number for more details.
Use left/right arrows to navigate the slideshow or swipe left/right if using a mobile device
Choosing a selection results in a full page refresh.
Press the space key then arrow keys to make a selection.
Shopping Cart
{"id":10017451442493,"title":"CINT1150A2406K01","handle":"cint1150a2406k01","description":"\u003ch3\u003eADVANCED ENERGY \/ SL POWER \/ CONDOR CINT1150A2406K01 AC-DC Regulated Power Supply Module 150W\u003c\/h3\u003e\n\u003cp\u003eUpgrade your industrial power solutions with the high-performance \u003cstrong\u003eCINT1150A2406K01\u003c\/strong\u003e AC-DC power supply module from \u003cstrong\u003eADVANCED ENERGY \/ SL POWER \/ CONDOR\u003c\/strong\u003e. Designed for demanding applications, this 150W switching power supply offers reliable, efficient power conversion in a compact form factor.\u003c\/p\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-density 2” x 4” x 1.3” open-frame design suitable for 1U applications\u003c\/li\u003e\n\u003cli\u003eUniversal input voltage range of 90-264 VAC for global compatibility\u003c\/li\u003e\n\u003cli\u003eWide operating temperature from -10°C to +70°C, with full rated power up to +50°C\u003c\/li\u003e\n\u003cli\u003ePower Fail and DC OK signals for system monitoring\u003c\/li\u003e\n\u003cli\u003eApproved to CSA, EN, IEC, UL60950-1, 2nd Edition safety standards\u003c\/li\u003e\n\u003cli\u003eRoHS compliant for environmentally responsible design\u003c\/li\u003e\n\u003cli\u003eHiccup mode overload protection and short circuit protection\u003c\/li\u003e\n\u003cli\u003eHigh efficiency rated at 88% typical at 115VAC\u003c\/li\u003e\n\u003cli\u003eMultiple safety and EMC compliance standards including EN55011\/22, FCC, EN61000 series\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power\u003c\/td\u003e\n\u003ctd\u003e150W continuous with 200 LFM airflow; 100W convection cooled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24V (model: CINT1150A2406K01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e6.25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRipple \u0026amp; Noise\u003c\/td\u003e\n\u003ctd\u003e0.5% RMS, 1.0% pk-pk\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Regulation\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Threshold\u003c\/td\u003e\n\u003ctd\u003e28.0 ± 2.5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eTypically 88% at 115VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eInput-Output: 4000Vac; Input-Ground: 1800Vac; Output-Ground: 500Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10°C to +70°C; derates above 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e2.0” W x 4.0” L x 1.3” H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e183g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eEN\/CSA\/UL\/IEC60950-1, 2nd Edition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInput Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e90-264 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e47-63Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e≤50A at 264VAC, cold start\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor\u003c\/td\u003e\n\u003ctd\u003e≥0.9 at nominal conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Fuses\u003c\/td\u003e\n\u003ctd\u003e4A, 250VAC (F1, F2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eTypically 88%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProtection and Safety\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHiccup mode overload and short circuit protection\u003c\/li\u003e\n\u003cli\u003eOvervoltage protection with latch mode\u003c\/li\u003e\n\u003cli\u003eAutomatic shutdown at 155°C temperature\u003c\/li\u003e\n\u003cli\u003eInsulation Safety Rating: Basic Reinforced\u003c\/li\u003e\n\u003cli\u003eIsolation Voltage: Input-Output 4000Vac, Input-Ground 1800Vac, Output-Ground 500Vac\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAuxiliary Signals \u0026amp; Connectors\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAC Power Fail: stays HIGH during normal operation\u003c\/li\u003e\n\u003cli\u003ePower Fail: goes LOW with a 5ms warning before power loss\u003c\/li\u003e\n\u003cli\u003eDC OK: open collector signal, HIGH 100-500ms after regulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003eMolex 09-50-3031 (Pins: 08-52-0072)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround\u003c\/td\u003e\n\u003ctd\u003eMolex 01-90020009\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Output\u003c\/td\u003e\n\u003ctd\u003eAMP 640250-6 (Pins: 640252-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignals\u003c\/td\u003e\n\u003ctd\u003eMolex 1375820-2 (Pins: 1375819)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCertifications \u0026amp; Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEN55011\/22 Class B (Conducted Emissions)\u003c\/li\u003e\n\u003cli\u003eEN55011\/22 Class A (Radiated Emissions)\u003c\/li\u003e\n\u003cli\u003eEN61000-4 series immunity standards\u003c\/li\u003e\n\u003cli\u003eFCC Part 15, Subpart B, Class A\/B\u003c\/li\u003e\n\u003cli\u003eIEC\/CSA\/UL safety standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor more detailed specifications and technical information, please refer to the \u003ca href=\"https:\/\/www.waldomapac.com\/productfiles\/mf-cod\/198cint1150_ds.pdf\" target=\"_blank\"\u003edatasheet\u003c\/a\u003e. Datasheet was not processed please search the internet for the part number for more details.\u003c\/p\u003e","published_at":"2025-08-11T08:10:10+05:30","created_at":"2025-08-11T08:10:10+05:30","vendor":"Waldom Electonics","type":"AC-DC Power Supply","tags":["150W","AC","ADVAN-SLPO","IMPORT_CSV","Power","Switching","WLDM"],"price":812005,"price_min":812005,"price_max":812005,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50598222233917,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"CINT1150A2406K01","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"CINT1150A2406K01","public_title":null,"options":["Default Title"],"price":812005,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"CINT1150A2406K01","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/CINT1150A2406K01_44153642_c53bafb2.jpg?v=1754880014"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/CINT1150A2406K01_44153642_c53bafb2.jpg?v=1754880014","options":["Title"],"media":[{"alt":null,"id":45775716942141,"position":1,"preview_image":{"aspect_ratio":1.0,"height":200,"width":200,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/CINT1150A2406K01_44153642_c53bafb2.jpg?v=1754880014"},"aspect_ratio":1.0,"height":200,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/CINT1150A2406K01_44153642_c53bafb2.jpg?v=1754880014","width":200}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eADVANCED ENERGY \/ SL POWER \/ CONDOR CINT1150A2406K01 AC-DC Regulated Power Supply Module 150W\u003c\/h3\u003e\n\u003cp\u003eUpgrade your industrial power solutions with the high-performance \u003cstrong\u003eCINT1150A2406K01\u003c\/strong\u003e AC-DC power supply module from \u003cstrong\u003eADVANCED ENERGY \/ SL POWER \/ CONDOR\u003c\/strong\u003e. Designed for demanding applications, this 150W switching power supply offers reliable, efficient power conversion in a compact form factor.\u003c\/p\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-density 2” x 4” x 1.3” open-frame design suitable for 1U applications\u003c\/li\u003e\n\u003cli\u003eUniversal input voltage range of 90-264 VAC for global compatibility\u003c\/li\u003e\n\u003cli\u003eWide operating temperature from -10°C to +70°C, with full rated power up to +50°C\u003c\/li\u003e\n\u003cli\u003ePower Fail and DC OK signals for system monitoring\u003c\/li\u003e\n\u003cli\u003eApproved to CSA, EN, IEC, UL60950-1, 2nd Edition safety standards\u003c\/li\u003e\n\u003cli\u003eRoHS compliant for environmentally responsible design\u003c\/li\u003e\n\u003cli\u003eHiccup mode overload protection and short circuit protection\u003c\/li\u003e\n\u003cli\u003eHigh efficiency rated at 88% typical at 115VAC\u003c\/li\u003e\n\u003cli\u003eMultiple safety and EMC compliance standards including EN55011\/22, FCC, EN61000 series\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power\u003c\/td\u003e\n\u003ctd\u003e150W continuous with 200 LFM airflow; 100W convection cooled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24V (model: CINT1150A2406K01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e6.25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRipple \u0026amp; Noise\u003c\/td\u003e\n\u003ctd\u003e0.5% RMS, 1.0% pk-pk\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Regulation\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Threshold\u003c\/td\u003e\n\u003ctd\u003e28.0 ± 2.5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eTypically 88% at 115VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eInput-Output: 4000Vac; Input-Ground: 1800Vac; Output-Ground: 500Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10°C to +70°C; derates above 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e2.0” W x 4.0” L x 1.3” H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e183g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eEN\/CSA\/UL\/IEC60950-1, 2nd Edition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInput Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e90-264 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e47-63Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e≤50A at 264VAC, cold start\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor\u003c\/td\u003e\n\u003ctd\u003e≥0.9 at nominal conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Fuses\u003c\/td\u003e\n\u003ctd\u003e4A, 250VAC (F1, F2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eTypically 88%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProtection and Safety\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHiccup mode overload and short circuit protection\u003c\/li\u003e\n\u003cli\u003eOvervoltage protection with latch mode\u003c\/li\u003e\n\u003cli\u003eAutomatic shutdown at 155°C temperature\u003c\/li\u003e\n\u003cli\u003eInsulation Safety Rating: Basic Reinforced\u003c\/li\u003e\n\u003cli\u003eIsolation Voltage: Input-Output 4000Vac, Input-Ground 1800Vac, Output-Ground 500Vac\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAuxiliary Signals \u0026amp; Connectors\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAC Power Fail: stays HIGH during normal operation\u003c\/li\u003e\n\u003cli\u003ePower Fail: goes LOW with a 5ms warning before power loss\u003c\/li\u003e\n\u003cli\u003eDC OK: open collector signal, HIGH 100-500ms after regulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003eMolex 09-50-3031 (Pins: 08-52-0072)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround\u003c\/td\u003e\n\u003ctd\u003eMolex 01-90020009\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Output\u003c\/td\u003e\n\u003ctd\u003eAMP 640250-6 (Pins: 640252-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignals\u003c\/td\u003e\n\u003ctd\u003eMolex 1375820-2 (Pins: 1375819)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCertifications \u0026amp; Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEN55011\/22 Class B (Conducted Emissions)\u003c\/li\u003e\n\u003cli\u003eEN55011\/22 Class A (Radiated Emissions)\u003c\/li\u003e\n\u003cli\u003eEN61000-4 series immunity standards\u003c\/li\u003e\n\u003cli\u003eFCC Part 15, Subpart B, Class A\/B\u003c\/li\u003e\n\u003cli\u003eIEC\/CSA\/UL safety standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor more detailed specifications and technical information, please refer to the \u003ca href=\"https:\/\/www.waldomapac.com\/productfiles\/mf-cod\/198cint1150_ds.pdf\" target=\"_blank\"\u003edatasheet\u003c\/a\u003e. Datasheet was not processed please search the internet for the part number for more details.\u003c\/p\u003e"}