ADVANCED ENERGY / SL POWER / CONDOR CINT1150A2406K01 AC-DC Regulated Power Supply Module 150W
Upgrade your industrial power solutions with the high-performance CINT1150A2406K01 AC-DC power supply module from ADVANCED ENERGY / SL POWER / CONDOR. Designed for demanding applications, this 150W switching power supply offers reliable, efficient power conversion in a compact form factor.
Product Features
High-density 2” x 4” x 1.3” open-frame design suitable for 1U applications
Universal input voltage range of 90-264 VAC for global compatibility
Wide operating temperature from -10°C to +70°C, with full rated power up to +50°C
Power Fail and DC OK signals for system monitoring
Approved to CSA, EN, IEC, UL60950-1, 2nd Edition safety standards
RoHS compliant for environmentally responsible design
Hiccup mode overload protection and short circuit protection
High efficiency rated at 88% typical at 115VAC
Multiple safety and EMC compliance standards including EN55011/22, FCC, EN61000 series
Technical Specifications
Parameter
Details
Output Power
150W continuous with 200 LFM airflow; 100W convection cooled
Power Fail: goes LOW with a 5ms warning before power loss
DC OK: open collector signal, HIGH 100-500ms after regulation
Connector
Details
Input
Molex 09-50-3031 (Pins: 08-52-0072)
Ground
Molex 01-90020009
DC Output
AMP 640250-6 (Pins: 640252-1)
Signals
Molex 1375820-2 (Pins: 1375819)
Certifications & Compliance
EN55011/22 Class B (Conducted Emissions)
EN55011/22 Class A (Radiated Emissions)
EN61000-4 series immunity standards
FCC Part 15, Subpart B, Class A/B
IEC/CSA/UL safety standards
For more detailed specifications and technical information, please refer to the datasheet. Datasheet was not processed please search the internet for the part number for more details.
{"id":10017451442493,"title":"CINT1150A2406K01","handle":"cint1150a2406k01","description":"\u003ch3\u003eADVANCED ENERGY \/ SL POWER \/ CONDOR CINT1150A2406K01 AC-DC Regulated Power Supply Module 150W\u003c\/h3\u003e\n\u003cp\u003eUpgrade your industrial power solutions with the high-performance \u003cstrong\u003eCINT1150A2406K01\u003c\/strong\u003e AC-DC power supply module from \u003cstrong\u003eADVANCED ENERGY \/ SL POWER \/ CONDOR\u003c\/strong\u003e. Designed for demanding applications, this 150W switching power supply offers reliable, efficient power conversion in a compact form factor.\u003c\/p\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-density 2” x 4” x 1.3” open-frame design suitable for 1U applications\u003c\/li\u003e\n\u003cli\u003eUniversal input voltage range of 90-264 VAC for global compatibility\u003c\/li\u003e\n\u003cli\u003eWide operating temperature from -10°C to +70°C, with full rated power up to +50°C\u003c\/li\u003e\n\u003cli\u003ePower Fail and DC OK signals for system monitoring\u003c\/li\u003e\n\u003cli\u003eApproved to CSA, EN, IEC, UL60950-1, 2nd Edition safety standards\u003c\/li\u003e\n\u003cli\u003eRoHS compliant for environmentally responsible design\u003c\/li\u003e\n\u003cli\u003eHiccup mode overload protection and short circuit protection\u003c\/li\u003e\n\u003cli\u003eHigh efficiency rated at 88% typical at 115VAC\u003c\/li\u003e\n\u003cli\u003eMultiple safety and EMC compliance standards including EN55011\/22, FCC, EN61000 series\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power\u003c\/td\u003e\n\u003ctd\u003e150W continuous with 200 LFM airflow; 100W convection cooled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24V (model: CINT1150A2406K01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e6.25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRipple \u0026amp; Noise\u003c\/td\u003e\n\u003ctd\u003e0.5% RMS, 1.0% pk-pk\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Regulation\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Threshold\u003c\/td\u003e\n\u003ctd\u003e28.0 ± 2.5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eTypically 88% at 115VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eInput-Output: 4000Vac; Input-Ground: 1800Vac; Output-Ground: 500Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10°C to +70°C; derates above 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e2.0” W x 4.0” L x 1.3” H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e183g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eEN\/CSA\/UL\/IEC60950-1, 2nd Edition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInput Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e90-264 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e47-63Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e≤50A at 264VAC, cold start\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor\u003c\/td\u003e\n\u003ctd\u003e≥0.9 at nominal conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Fuses\u003c\/td\u003e\n\u003ctd\u003e4A, 250VAC (F1, F2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eTypically 88%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProtection and Safety\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHiccup mode overload and short circuit protection\u003c\/li\u003e\n\u003cli\u003eOvervoltage protection with latch mode\u003c\/li\u003e\n\u003cli\u003eAutomatic shutdown at 155°C temperature\u003c\/li\u003e\n\u003cli\u003eInsulation Safety Rating: Basic Reinforced\u003c\/li\u003e\n\u003cli\u003eIsolation Voltage: Input-Output 4000Vac, Input-Ground 1800Vac, Output-Ground 500Vac\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAuxiliary Signals \u0026amp; Connectors\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAC Power Fail: stays HIGH during normal operation\u003c\/li\u003e\n\u003cli\u003ePower Fail: goes LOW with a 5ms warning before power loss\u003c\/li\u003e\n\u003cli\u003eDC OK: open collector signal, HIGH 100-500ms after regulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003eMolex 09-50-3031 (Pins: 08-52-0072)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround\u003c\/td\u003e\n\u003ctd\u003eMolex 01-90020009\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Output\u003c\/td\u003e\n\u003ctd\u003eAMP 640250-6 (Pins: 640252-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignals\u003c\/td\u003e\n\u003ctd\u003eMolex 1375820-2 (Pins: 1375819)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCertifications \u0026amp; Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEN55011\/22 Class B (Conducted Emissions)\u003c\/li\u003e\n\u003cli\u003eEN55011\/22 Class A (Radiated Emissions)\u003c\/li\u003e\n\u003cli\u003eEN61000-4 series immunity standards\u003c\/li\u003e\n\u003cli\u003eFCC Part 15, Subpart B, Class A\/B\u003c\/li\u003e\n\u003cli\u003eIEC\/CSA\/UL safety standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor more detailed specifications and technical information, please refer to the \u003ca href=\"https:\/\/www.waldomapac.com\/productfiles\/mf-cod\/198cint1150_ds.pdf\" target=\"_blank\"\u003edatasheet\u003c\/a\u003e. Datasheet was not processed please search the internet for the part number for more details.\u003c\/p\u003e","published_at":"2025-08-11T08:10:10+05:30","created_at":"2025-08-11T08:10:10+05:30","vendor":"Waldom Electonics","type":"AC-DC Power Supply","tags":["150W","AC","ADVAN-SLPO","IMPORT_CSV","Power","Switching","WLDM"],"price":812005,"price_min":812005,"price_max":812005,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50598222233917,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"CINT1150A2406K01","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"CINT1150A2406K01","public_title":null,"options":["Default Title"],"price":812005,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"CINT1150A2406K01","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/CINT1150A2406K01_44153642_c53bafb2.jpg?v=1754880014"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/CINT1150A2406K01_44153642_c53bafb2.jpg?v=1754880014","options":["Title"],"media":[{"alt":null,"id":45775716942141,"position":1,"preview_image":{"aspect_ratio":1.0,"height":200,"width":200,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/CINT1150A2406K01_44153642_c53bafb2.jpg?v=1754880014"},"aspect_ratio":1.0,"height":200,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/CINT1150A2406K01_44153642_c53bafb2.jpg?v=1754880014","width":200}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eADVANCED ENERGY \/ SL POWER \/ CONDOR CINT1150A2406K01 AC-DC Regulated Power Supply Module 150W\u003c\/h3\u003e\n\u003cp\u003eUpgrade your industrial power solutions with the high-performance \u003cstrong\u003eCINT1150A2406K01\u003c\/strong\u003e AC-DC power supply module from \u003cstrong\u003eADVANCED ENERGY \/ SL POWER \/ CONDOR\u003c\/strong\u003e. Designed for demanding applications, this 150W switching power supply offers reliable, efficient power conversion in a compact form factor.\u003c\/p\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-density 2” x 4” x 1.3” open-frame design suitable for 1U applications\u003c\/li\u003e\n\u003cli\u003eUniversal input voltage range of 90-264 VAC for global compatibility\u003c\/li\u003e\n\u003cli\u003eWide operating temperature from -10°C to +70°C, with full rated power up to +50°C\u003c\/li\u003e\n\u003cli\u003ePower Fail and DC OK signals for system monitoring\u003c\/li\u003e\n\u003cli\u003eApproved to CSA, EN, IEC, UL60950-1, 2nd Edition safety standards\u003c\/li\u003e\n\u003cli\u003eRoHS compliant for environmentally responsible design\u003c\/li\u003e\n\u003cli\u003eHiccup mode overload protection and short circuit protection\u003c\/li\u003e\n\u003cli\u003eHigh efficiency rated at 88% typical at 115VAC\u003c\/li\u003e\n\u003cli\u003eMultiple safety and EMC compliance standards including EN55011\/22, FCC, EN61000 series\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power\u003c\/td\u003e\n\u003ctd\u003e150W continuous with 200 LFM airflow; 100W convection cooled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24V (model: CINT1150A2406K01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e6.25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRipple \u0026amp; Noise\u003c\/td\u003e\n\u003ctd\u003e0.5% RMS, 1.0% pk-pk\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Regulation\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Threshold\u003c\/td\u003e\n\u003ctd\u003e28.0 ± 2.5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eTypically 88% at 115VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eInput-Output: 4000Vac; Input-Ground: 1800Vac; Output-Ground: 500Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10°C to +70°C; derates above 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e2.0” W x 4.0” L x 1.3” H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e183g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eEN\/CSA\/UL\/IEC60950-1, 2nd Edition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInput Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e90-264 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e47-63Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e≤50A at 264VAC, cold start\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor\u003c\/td\u003e\n\u003ctd\u003e≥0.9 at nominal conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Fuses\u003c\/td\u003e\n\u003ctd\u003e4A, 250VAC (F1, F2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eTypically 88%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProtection and Safety\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHiccup mode overload and short circuit protection\u003c\/li\u003e\n\u003cli\u003eOvervoltage protection with latch mode\u003c\/li\u003e\n\u003cli\u003eAutomatic shutdown at 155°C temperature\u003c\/li\u003e\n\u003cli\u003eInsulation Safety Rating: Basic Reinforced\u003c\/li\u003e\n\u003cli\u003eIsolation Voltage: Input-Output 4000Vac, Input-Ground 1800Vac, Output-Ground 500Vac\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAuxiliary Signals \u0026amp; Connectors\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAC Power Fail: stays HIGH during normal operation\u003c\/li\u003e\n\u003cli\u003ePower Fail: goes LOW with a 5ms warning before power loss\u003c\/li\u003e\n\u003cli\u003eDC OK: open collector signal, HIGH 100-500ms after regulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003eMolex 09-50-3031 (Pins: 08-52-0072)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround\u003c\/td\u003e\n\u003ctd\u003eMolex 01-90020009\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Output\u003c\/td\u003e\n\u003ctd\u003eAMP 640250-6 (Pins: 640252-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignals\u003c\/td\u003e\n\u003ctd\u003eMolex 1375820-2 (Pins: 1375819)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCertifications \u0026amp; Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEN55011\/22 Class B (Conducted Emissions)\u003c\/li\u003e\n\u003cli\u003eEN55011\/22 Class A (Radiated Emissions)\u003c\/li\u003e\n\u003cli\u003eEN61000-4 series immunity standards\u003c\/li\u003e\n\u003cli\u003eFCC Part 15, Subpart B, Class A\/B\u003c\/li\u003e\n\u003cli\u003eIEC\/CSA\/UL safety standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor more detailed specifications and technical information, please refer to the \u003ca href=\"https:\/\/www.waldomapac.com\/productfiles\/mf-cod\/198cint1150_ds.pdf\" target=\"_blank\"\u003edatasheet\u003c\/a\u003e. Datasheet was not processed please search the internet for the part number for more details.\u003c\/p\u003e"}