ITC CANNON D-Sub Standard Connectors RP BKAF 22 CONT MOD WA
Enhance your electronic connectivity with the ITT CANNON D-Sub Standard Connectors, designed for reliable performance in industrial applications. These connectors feature robust construction, precise electrical specifications, and versatile mounting options to suit various operational needs.
7.5 A (size 20), 22.0 A (size 16); test current below 55 mV and 50 mV respectively
Test voltage
1,500 V to 3,200 V depending on service class
Water tightness
Meets VG 95319 Part 2, Test Nr. 5.9.2 with 0.2 bar overpressure for 48 hours at 25°C
Contact Arrangement & Insulator Positions
Shell Size
Contact Arrangement
Insulator Positions
10
10-6
- 90 - -
12
12-3
- - 180
10
12-10
- 60 155 270 295
14
14-5
- 40 92 184 273
12
14-12
- 43 90 - -
15
14-15
- 17 110 155 234
19
14-19
- 30 165 315 -
16
8-16
- 54 152 180 331
23
16-23
- 158 270 - -
26
16-26
- 60 - 275 338
For more detailed specifications, please refer to the datasheet.
Note: Use of these connectors for voltages exceeding 50V with touchable conductive parts must comply with safety regulations DIN VDE Part 410 and IEC 60364-4-41. Power sources should be disconnected before mating or unmating to ensure safety.
Note: The product image displayed is a standard reference image. Actual product appearance may vary. For the most accurate and up-to-date representation, we recommend searching the part number online.
Use left/right arrows to navigate the slideshow or swipe left/right if using a mobile device
Choosing a selection results in a full page refresh.
Press the space key then arrow keys to make a selection.
Shopping Cart
{"id":10075002437949,"title":"031-1351-000","handle":"031-1351-000","description":"\u003ch3\u003eITC CANNON D-Sub Standard Connectors RP BKAF 22 CONT MOD WA\u003c\/h3\u003e\n\u003cp\u003eEnhance your electronic connectivity with the ITT CANNON D-Sub Standard Connectors, designed for reliable performance in industrial applications. These connectors feature robust construction, precise electrical specifications, and versatile mounting options to suit various operational needs.\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 031-1351-000\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ITT CANNON\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e US\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eUnit of Measure:\u003c\/strong\u003e EA\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e EAR99\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003ePackage Type:\u003c\/strong\u003e Not specified\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eDatasheet:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.waldomapac.com\/productfiles\/mf-can\/kptc_catalog_q3_1998.pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eStandard D-Sub connector with 22 contact positions\u003c\/li\u003e\n \u003cli\u003eConstructed with aluminum alloy shell, nickel plated for durability\u003c\/li\u003e\n \u003cli\u003eCopper alloy contacts with hard gold or silver plating for reliable electrical performance\u003c\/li\u003e\n \u003cli\u003eWater-tight design compliant with VG 95319 Part 2, Test Nr. 5.9.2\u003c\/li\u003e\n \u003cli\u003eSuitable for service classes A to E, J to W, Z1, Z2, Z3 with gasket styles A and B\u003c\/li\u003e\n \u003cli\u003eMultiple mounting options including wall, box, straight, and jam nut configurations\u003c\/li\u003e\n \u003cli\u003eElectrical ratings include a test voltage of up to 3200 V at sea level and 770 V at 21336 m altitude\u003c\/li\u003e\n \u003cli\u003eCompatible with wire sizes from 0.4 mm² to 2.0 mm²\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n \u003ctr\u003e\n \u003cth\u003eParameter\u003c\/th\u003e\n \u003cth\u003eDetails\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eNumber of contacts\u003c\/td\u003e\n \u003ctd\u003e6 to 26\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eWire size\u003c\/td\u003e\n \u003ctd\u003e0.4 – 0.75 mm² (contact size 20), 1.0 – 2.0 mm² (contact size 16)\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eContact rating\u003c\/td\u003e\n \u003ctd\u003e7.5 A (size 20), 22.0 A (size 16); test current below 55 mV and 50 mV respectively\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eTest voltage\u003c\/td\u003e\n \u003ctd\u003e1,500 V to 3,200 V depending on service class\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eWater tightness\u003c\/td\u003e\n \u003ctd\u003eMeets VG 95319 Part 2, Test Nr. 5.9.2 with 0.2 bar overpressure for 48 hours at 25°C\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eContact Arrangement \u0026amp; Insulator Positions\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n \u003ctr\u003e\n \u003cth\u003eShell Size\u003c\/th\u003e\n \u003cth\u003eContact Arrangement\u003c\/th\u003e\n \u003cth\u003eInsulator Positions\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e10\u003c\/td\u003e\n \u003ctd\u003e10-6\u003c\/td\u003e\n \u003ctd\u003e- 90 - -\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e12\u003c\/td\u003e\n \u003ctd\u003e12-3\u003c\/td\u003e\n \u003ctd\u003e- - 180\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e10\u003c\/td\u003e\n \u003ctd\u003e12-10\u003c\/td\u003e\n \u003ctd\u003e- 60 155 270 295\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e14\u003c\/td\u003e\n \u003ctd\u003e14-5\u003c\/td\u003e\n \u003ctd\u003e- 40 92 184 273\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e12\u003c\/td\u003e\n \u003ctd\u003e14-12\u003c\/td\u003e\n \u003ctd\u003e- 43 90 - -\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e15\u003c\/td\u003e\n \u003ctd\u003e14-15\u003c\/td\u003e\n \u003ctd\u003e- 17 110 155 234\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e19\u003c\/td\u003e\n \u003ctd\u003e14-19\u003c\/td\u003e\n \u003ctd\u003e- 30 165 315 -\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e16\u003c\/td\u003e\n \u003ctd\u003e8-16\u003c\/td\u003e\n \u003ctd\u003e- 54 152 180 331\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e23\u003c\/td\u003e\n \u003ctd\u003e16-23\u003c\/td\u003e\n \u003ctd\u003e- 158 270 - -\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e26\u003c\/td\u003e\n \u003ctd\u003e16-26\u003c\/td\u003e\n \u003ctd\u003e- 60 - 275 338\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eFor more detailed specifications, please refer to the \u003ca href=\"https:\/\/www.waldomapac.com\/productfiles\/mf-can\/kptc_catalog_q3_1998.pdf\" target=\"_blank\"\u003edatasheet\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Use of these connectors for voltages exceeding 50V with touchable conductive parts must comply with safety regulations DIN VDE Part 410 and IEC 60364-4-41. Power sources should be disconnected before mating or unmating to ensure safety.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNote: The product image displayed is a standard reference image. Actual product appearance may vary. For the most accurate and up-to-date representation, we recommend searching the part number online.\u003c\/strong\u003e\u003c\/p\u003e","published_at":"2025-09-22T01:07:36+05:30","created_at":"2025-09-22T01:07:36+05:30","vendor":"Waldom Electonics","type":"Connector","tags":["STD_IMG","WLDM"],"price":131523,"price_min":131523,"price_max":131523,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50765570441533,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"031-1351-000","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"031-1351-000","public_title":null,"options":["Default Title"],"price":131523,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"031-1351-000","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/fbe811dc-181f-41c1-ab5a-dc3410446d1d_35105366-7860-4826-b5b4-7f449756fb7c.jpg?v=1758483456"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/fbe811dc-181f-41c1-ab5a-dc3410446d1d_35105366-7860-4826-b5b4-7f449756fb7c.jpg?v=1758483456","options":["Title"],"media":[{"alt":null,"id":46539308106045,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1024,"width":1024,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/fbe811dc-181f-41c1-ab5a-dc3410446d1d_35105366-7860-4826-b5b4-7f449756fb7c.jpg?v=1758483456"},"aspect_ratio":1.0,"height":1024,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/fbe811dc-181f-41c1-ab5a-dc3410446d1d_35105366-7860-4826-b5b4-7f449756fb7c.jpg?v=1758483456","width":1024}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eITC CANNON D-Sub Standard Connectors RP BKAF 22 CONT MOD WA\u003c\/h3\u003e\n\u003cp\u003eEnhance your electronic connectivity with the ITT CANNON D-Sub Standard Connectors, designed for reliable performance in industrial applications. These connectors feature robust construction, precise electrical specifications, and versatile mounting options to suit various operational needs.\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 031-1351-000\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ITT CANNON\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e US\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eUnit of Measure:\u003c\/strong\u003e EA\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e EAR99\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003ePackage Type:\u003c\/strong\u003e Not specified\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eDatasheet:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.waldomapac.com\/productfiles\/mf-can\/kptc_catalog_q3_1998.pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eStandard D-Sub connector with 22 contact positions\u003c\/li\u003e\n \u003cli\u003eConstructed with aluminum alloy shell, nickel plated for durability\u003c\/li\u003e\n \u003cli\u003eCopper alloy contacts with hard gold or silver plating for reliable electrical performance\u003c\/li\u003e\n \u003cli\u003eWater-tight design compliant with VG 95319 Part 2, Test Nr. 5.9.2\u003c\/li\u003e\n \u003cli\u003eSuitable for service classes A to E, J to W, Z1, Z2, Z3 with gasket styles A and B\u003c\/li\u003e\n \u003cli\u003eMultiple mounting options including wall, box, straight, and jam nut configurations\u003c\/li\u003e\n \u003cli\u003eElectrical ratings include a test voltage of up to 3200 V at sea level and 770 V at 21336 m altitude\u003c\/li\u003e\n \u003cli\u003eCompatible with wire sizes from 0.4 mm² to 2.0 mm²\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n \u003ctr\u003e\n \u003cth\u003eParameter\u003c\/th\u003e\n \u003cth\u003eDetails\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eNumber of contacts\u003c\/td\u003e\n \u003ctd\u003e6 to 26\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eWire size\u003c\/td\u003e\n \u003ctd\u003e0.4 – 0.75 mm² (contact size 20), 1.0 – 2.0 mm² (contact size 16)\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eContact rating\u003c\/td\u003e\n \u003ctd\u003e7.5 A (size 20), 22.0 A (size 16); test current below 55 mV and 50 mV respectively\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eTest voltage\u003c\/td\u003e\n \u003ctd\u003e1,500 V to 3,200 V depending on service class\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eWater tightness\u003c\/td\u003e\n \u003ctd\u003eMeets VG 95319 Part 2, Test Nr. 5.9.2 with 0.2 bar overpressure for 48 hours at 25°C\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eContact Arrangement \u0026amp; Insulator Positions\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n \u003ctr\u003e\n \u003cth\u003eShell Size\u003c\/th\u003e\n \u003cth\u003eContact Arrangement\u003c\/th\u003e\n \u003cth\u003eInsulator Positions\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e10\u003c\/td\u003e\n \u003ctd\u003e10-6\u003c\/td\u003e\n \u003ctd\u003e- 90 - -\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e12\u003c\/td\u003e\n \u003ctd\u003e12-3\u003c\/td\u003e\n \u003ctd\u003e- - 180\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e10\u003c\/td\u003e\n \u003ctd\u003e12-10\u003c\/td\u003e\n \u003ctd\u003e- 60 155 270 295\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e14\u003c\/td\u003e\n \u003ctd\u003e14-5\u003c\/td\u003e\n \u003ctd\u003e- 40 92 184 273\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e12\u003c\/td\u003e\n \u003ctd\u003e14-12\u003c\/td\u003e\n \u003ctd\u003e- 43 90 - -\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e15\u003c\/td\u003e\n \u003ctd\u003e14-15\u003c\/td\u003e\n \u003ctd\u003e- 17 110 155 234\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e19\u003c\/td\u003e\n \u003ctd\u003e14-19\u003c\/td\u003e\n \u003ctd\u003e- 30 165 315 -\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e16\u003c\/td\u003e\n \u003ctd\u003e8-16\u003c\/td\u003e\n \u003ctd\u003e- 54 152 180 331\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e23\u003c\/td\u003e\n \u003ctd\u003e16-23\u003c\/td\u003e\n \u003ctd\u003e- 158 270 - -\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e26\u003c\/td\u003e\n \u003ctd\u003e16-26\u003c\/td\u003e\n \u003ctd\u003e- 60 - 275 338\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eFor more detailed specifications, please refer to the \u003ca href=\"https:\/\/www.waldomapac.com\/productfiles\/mf-can\/kptc_catalog_q3_1998.pdf\" target=\"_blank\"\u003edatasheet\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Use of these connectors for voltages exceeding 50V with touchable conductive parts must comply with safety regulations DIN VDE Part 410 and IEC 60364-4-41. Power sources should be disconnected before mating or unmating to ensure safety.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNote: The product image displayed is a standard reference image. Actual product appearance may vary. For the most accurate and up-to-date representation, we recommend searching the part number online.\u003c\/strong\u003e\u003c\/p\u003e"}
NO PROPER USER MANUAL AND ORIGINAL BOX OF THE ELCTRNOICS ARE ALWAYS MISSING YOU ONLY SEND THE COMPONNET IN YOUR CARDBOARD BOX NO ORGINAL MANUAL NO ORGINAL BOX NOTHIING
High-performance Robotic Arm Gripper, Options for ST3215 / CF35-12 Serial Bus Servo, Closed-loop Control, Real-time Protection, Adjustable Gripper Stand-off