TE CONNECTIVITY/AGASTAT 2112AH1SDC947 Time Delay & Timing Relay
Part Number: 2112AH1SDC947
Manufacturer: TE CONNECTIVITY/AGASTAT BRAND
Country of Origin: US
Unit of Measure: EA
ECCN: EAR99
Package Type: PKG
Datasheet: Download Datasheet
Product Features
Miniature electro-pneumatic timing relay designed for high shock and vibration applications with hermetically sealed units.
High repeat accuracy over voltage and temperature extremes, with ±5% at 25°C in normal vertical position.
Adjustable delay ranges from milliseconds to 3 minutes, with easy linear adjustment via a circular-path Dial Head—no needle valves required.
Sealed timing head circulates air under controlled pressure for reliable operation.
Snap-action switch assembly ensures sustained contact pressure during timing cycles, with special over-center mechanism for flutter-free load transfer.
Precision-wound solenoid assembly provides the basic motive force when the control circuit is closed.
Robust construction in a self-supporting steel enclosure ensures long trouble-free operation.
Operation & Timing Ranges
Series 2112 (On-Delay):
Applies rated voltage to start pre-set delay; NC contacts break and NO contacts make at end of delay.
Contacts remain until coil is de-energized, then switch resets within 25 ms.
Series 2122 (Off-Delay):
Applying rated voltage for at least 75 ms initiates immediate transfer of contacts.
Delay begins upon coil de-energization; contacts revert after preset delay.
No power required during delay; re-energizing restarts cycle.
Timing Adjustment & Ranges
Easy linear adjustment over nine ranges:
Range Codes and Durations:
Code
Range
A
0.03 to 0.1 sec
B
0.1 to 0.3 sec
C
0.15 to 1.0 sec
D
0.375 to 3.0 sec
E
0.75 to 10.0 sec
F
1.0 to 30.0 sec
G
2.0 to 60.0 sec
H
5.0 to 120.0 sec
J
5.0 to 180.0 sec
K
1.5 to 30.0 cycles
L
3.0 to 120.0 cycles
Electrical & Mechanical Specifications
Operating Voltage (Coil Data):
12VDC: Resistance 30Ω
28VDC: Resistance 131Ω
48VDC: Resistance 500Ω
110VDC: Resistance 3200Ω
120V 60Hz (Series 2112): Resistance 190Ω
120V 60Hz (Series 2122): Resistance 285Ω
240V 60Hz: Resistance 765Ω
115V 400Hz: Resistance 2600Ω
125VDC: Resistance 3380Ω
Contact Ratings (DPDT Contacts):
Voltage
Inductive (Amps)
Resistive (Amps)
30V DC
2
10
110V DC
0.75
1
120V 60Hz
3
10
120V 400Hz
1.5
10
240V
1
5
Ambient Temperature Range: -55°C to +85°C
Weight: Max 17 ozs
Mounting Options: Chassis mounting tabs, octal plugs, external or internal adjustment, panel mounting back plate
Additional Details
Hermetically sealed models circulate air under controlled pressure for reliable timing.
Designed for high shock and vibration environments.
Re-set time: 25 ms (Series 2112), 75 ms (Series 2122).
Relay operate time: 75 ms; release time: 25 ms.
Insensitivity to transients of ±1500 VAC for 10 milliseconds.
Dielectric withstands 1000V RMS at 60Hz between non-connected terminals.
For more detailed specifications, please refer to the datasheet. The datasheet was not processed; please search the internet for the part number for more details.
Note: The product image displayed is a standard reference image. Actual product appearance may vary. For the most accurate and up-to-date representation, we recommend searching the part number online.
The images of product "XT90 Parallel 2M-1F XT90 (10cm)" shows 10AWG cables, but what is sent is 14 AWG. Anyone with basic electrical background will know that XT90 plug is meant for high current of ~90 Amps, so it doesnt make any sense to have a product with 14 AWG cables. It is a poor quality product with misleading product images.
{"id":10007145087293,"title":"2112AH1SDC947","handle":"2112ah1sdc947","description":"\u003ch3\u003eTE CONNECTIVITY\/AGASTAT 2112AH1SDC947 Time Delay \u0026amp; Timing Relay\u003c\/h3\u003e\n\u003cp\u003ePart Number: 2112AH1SDC947\u003cbr\u003e\nManufacturer: TE CONNECTIVITY\/AGASTAT BRAND\u003cbr\u003e\nCountry of Origin: US\u003cbr\u003e\nUnit of Measure: EA\u003cbr\u003e\nECCN: EAR99\u003cbr\u003e\nPackage Type: PKG\u003cbr\u003e\nDatasheet: \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-ag\/2100.pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMiniature electro-pneumatic timing relay designed for high shock and vibration applications with hermetically sealed units.\u003c\/li\u003e\n\u003cli\u003eHigh repeat accuracy over voltage and temperature extremes, with ±5% at 25°C in normal vertical position.\u003c\/li\u003e\n\u003cli\u003eAdjustable delay ranges from milliseconds to 3 minutes, with easy linear adjustment via a circular-path Dial Head—no needle valves required.\u003c\/li\u003e\n\u003cli\u003eSealed timing head circulates air under controlled pressure for reliable operation.\u003c\/li\u003e\n\u003cli\u003eSnap-action switch assembly ensures sustained contact pressure during timing cycles, with special over-center mechanism for flutter-free load transfer.\u003c\/li\u003e\n\u003cli\u003ePrecision-wound solenoid assembly provides the basic motive force when the control circuit is closed.\u003c\/li\u003e\n\u003cli\u003eRobust construction in a self-supporting steel enclosure ensures long trouble-free operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOperation \u0026amp; Timing Ranges\u003c\/h3\u003e\n\u003cp\u003eSeries 2112 (On-Delay):\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eApplies rated voltage to start pre-set delay; NC contacts break and NO contacts make at end of delay.\u003c\/li\u003e\n\u003cli\u003eContacts remain until coil is de-energized, then switch resets within 25 ms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSeries 2122 (Off-Delay):\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eApplying rated voltage for at least 75 ms initiates immediate transfer of contacts.\u003c\/li\u003e\n\u003cli\u003eDelay begins upon coil de-energization; contacts revert after preset delay.\u003c\/li\u003e\n\u003cli\u003eNo power required during delay; re-energizing restarts cycle.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTiming Adjustment \u0026amp; Ranges\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEasy linear adjustment over nine ranges:\u003c\/li\u003e\n\u003cli\u003eRange Codes and Durations:\n \u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n \u003ctr\u003e\n \u003cth\u003eCode\u003c\/th\u003e\n \u003cth\u003eRange\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003e0.03 to 0.1 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003e0.1 to 0.3 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003e0.15 to 1.0 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003ctd\u003e0.375 to 3.0 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003eE\u003c\/td\u003e\n\u003ctd\u003e0.75 to 10.0 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003ctd\u003e1.0 to 30.0 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003eG\u003c\/td\u003e\n\u003ctd\u003e2.0 to 60.0 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003eH\u003c\/td\u003e\n\u003ctd\u003e5.0 to 120.0 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003eJ\u003c\/td\u003e\n\u003ctd\u003e5.0 to 180.0 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003eK\u003c\/td\u003e\n\u003ctd\u003e1.5 to 30.0 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003eL\u003c\/td\u003e\n\u003ctd\u003e3.0 to 120.0 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003c\/table\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eElectrical \u0026amp; Mechanical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Voltage (Coil Data): \n \u003cul\u003e\n \u003cli\u003e12VDC: Resistance 30Ω\u003c\/li\u003e\n \u003cli\u003e28VDC: Resistance 131Ω\u003c\/li\u003e\n \u003cli\u003e48VDC: Resistance 500Ω\u003c\/li\u003e\n \u003cli\u003e110VDC: Resistance 3200Ω\u003c\/li\u003e\n \u003cli\u003e120V 60Hz (Series 2112): Resistance 190Ω\u003c\/li\u003e\n \u003cli\u003e120V 60Hz (Series 2122): Resistance 285Ω\u003c\/li\u003e\n \u003cli\u003e240V 60Hz: Resistance 765Ω\u003c\/li\u003e\n \u003cli\u003e115V 400Hz: Resistance 2600Ω\u003c\/li\u003e\n \u003cli\u003e125VDC: Resistance 3380Ω\u003c\/li\u003e\n \u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eContact Ratings (DPDT Contacts):\n \u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n \u003ctr\u003e\n \u003cth\u003eVoltage\u003c\/th\u003e\n \u003cth\u003eInductive (Amps)\u003c\/th\u003e\n \u003cth\u003eResistive (Amps)\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e30V DC\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e110V DC\u003c\/td\u003e\n\u003ctd\u003e0.75\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e120V 60Hz\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e120V 400Hz\u003c\/td\u003e\n\u003ctd\u003e1.5\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e240V\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003c\/table\u003e\n\u003c\/li\u003e\n\u003cli\u003eAmbient Temperature Range: -55°C to +85°C\u003c\/li\u003e\n\u003cli\u003eWeight: Max 17 ozs\u003c\/li\u003e\n\u003cli\u003eMounting Options: Chassis mounting tabs, octal plugs, external or internal adjustment, panel mounting back plate\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAdditional Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHermetically sealed models circulate air under controlled pressure for reliable timing.\u003c\/li\u003e\n\u003cli\u003eDesigned for high shock and vibration environments.\u003c\/li\u003e\n\u003cli\u003eRe-set time: 25 ms (Series 2112), 75 ms (Series 2122).\u003c\/li\u003e\n\u003cli\u003eRelay operate time: 75 ms; release time: 25 ms.\u003c\/li\u003e\n\u003cli\u003eInsensitivity to transients of ±1500 VAC for 10 milliseconds.\u003c\/li\u003e\n\u003cli\u003eDielectric withstands 1000V RMS at 60Hz between non-connected terminals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eFor more detailed specifications, please refer to the \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-ag\/2100.pdf\" target=\"_blank\"\u003edatasheet\u003c\/a\u003e. The datasheet was not processed; please search the internet for the part number for more details.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNote: The product image displayed is a standard reference image. Actual product appearance may vary. For the most accurate and up-to-date representation, we recommend searching the part number online.\u003c\/strong\u003e\u003c\/p\u003e","published_at":"2025-08-07T10:54:10+05:30","created_at":"2025-08-07T10:54:10+05:30","vendor":"Waldom Electonics","type":"","tags":["Relay","RLY","STD_IMG","TE-AGAS","WLDM"],"price":47424593,"price_min":47424593,"price_max":47424593,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50558685020477,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"2112AH1SDC947","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"2112AH1SDC947","public_title":null,"options":["Default Title"],"price":47424593,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"2112AH1SDC947","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/fbe811dc-181f-41c1-ab5a-dc3410446d1d_caaaddd7-a2f2-4025-be68-cd2fdb9b8824.jpg?v=1754544250"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/fbe811dc-181f-41c1-ab5a-dc3410446d1d_caaaddd7-a2f2-4025-be68-cd2fdb9b8824.jpg?v=1754544250","options":["Title"],"media":[{"alt":null,"id":45709203669309,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1024,"width":1024,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/fbe811dc-181f-41c1-ab5a-dc3410446d1d_caaaddd7-a2f2-4025-be68-cd2fdb9b8824.jpg?v=1754544250"},"aspect_ratio":1.0,"height":1024,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/fbe811dc-181f-41c1-ab5a-dc3410446d1d_caaaddd7-a2f2-4025-be68-cd2fdb9b8824.jpg?v=1754544250","width":1024}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eTE CONNECTIVITY\/AGASTAT 2112AH1SDC947 Time Delay \u0026amp; Timing Relay\u003c\/h3\u003e\n\u003cp\u003ePart Number: 2112AH1SDC947\u003cbr\u003e\nManufacturer: TE CONNECTIVITY\/AGASTAT BRAND\u003cbr\u003e\nCountry of Origin: US\u003cbr\u003e\nUnit of Measure: EA\u003cbr\u003e\nECCN: EAR99\u003cbr\u003e\nPackage Type: PKG\u003cbr\u003e\nDatasheet: \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-ag\/2100.pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMiniature electro-pneumatic timing relay designed for high shock and vibration applications with hermetically sealed units.\u003c\/li\u003e\n\u003cli\u003eHigh repeat accuracy over voltage and temperature extremes, with ±5% at 25°C in normal vertical position.\u003c\/li\u003e\n\u003cli\u003eAdjustable delay ranges from milliseconds to 3 minutes, with easy linear adjustment via a circular-path Dial Head—no needle valves required.\u003c\/li\u003e\n\u003cli\u003eSealed timing head circulates air under controlled pressure for reliable operation.\u003c\/li\u003e\n\u003cli\u003eSnap-action switch assembly ensures sustained contact pressure during timing cycles, with special over-center mechanism for flutter-free load transfer.\u003c\/li\u003e\n\u003cli\u003ePrecision-wound solenoid assembly provides the basic motive force when the control circuit is closed.\u003c\/li\u003e\n\u003cli\u003eRobust construction in a self-supporting steel enclosure ensures long trouble-free operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOperation \u0026amp; Timing Ranges\u003c\/h3\u003e\n\u003cp\u003eSeries 2112 (On-Delay):\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eApplies rated voltage to start pre-set delay; NC contacts break and NO contacts make at end of delay.\u003c\/li\u003e\n\u003cli\u003eContacts remain until coil is de-energized, then switch resets within 25 ms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSeries 2122 (Off-Delay):\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eApplying rated voltage for at least 75 ms initiates immediate transfer of contacts.\u003c\/li\u003e\n\u003cli\u003eDelay begins upon coil de-energization; contacts revert after preset delay.\u003c\/li\u003e\n\u003cli\u003eNo power required during delay; re-energizing restarts cycle.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTiming Adjustment \u0026amp; Ranges\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEasy linear adjustment over nine ranges:\u003c\/li\u003e\n\u003cli\u003eRange Codes and Durations:\n \u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n \u003ctr\u003e\n \u003cth\u003eCode\u003c\/th\u003e\n \u003cth\u003eRange\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003e0.03 to 0.1 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003e0.1 to 0.3 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003e0.15 to 1.0 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003ctd\u003e0.375 to 3.0 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003eE\u003c\/td\u003e\n\u003ctd\u003e0.75 to 10.0 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003ctd\u003e1.0 to 30.0 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003eG\u003c\/td\u003e\n\u003ctd\u003e2.0 to 60.0 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003eH\u003c\/td\u003e\n\u003ctd\u003e5.0 to 120.0 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003eJ\u003c\/td\u003e\n\u003ctd\u003e5.0 to 180.0 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003eK\u003c\/td\u003e\n\u003ctd\u003e1.5 to 30.0 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003eL\u003c\/td\u003e\n\u003ctd\u003e3.0 to 120.0 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003c\/table\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eElectrical \u0026amp; Mechanical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Voltage (Coil Data): \n \u003cul\u003e\n \u003cli\u003e12VDC: Resistance 30Ω\u003c\/li\u003e\n \u003cli\u003e28VDC: Resistance 131Ω\u003c\/li\u003e\n \u003cli\u003e48VDC: Resistance 500Ω\u003c\/li\u003e\n \u003cli\u003e110VDC: Resistance 3200Ω\u003c\/li\u003e\n \u003cli\u003e120V 60Hz (Series 2112): Resistance 190Ω\u003c\/li\u003e\n \u003cli\u003e120V 60Hz (Series 2122): Resistance 285Ω\u003c\/li\u003e\n \u003cli\u003e240V 60Hz: Resistance 765Ω\u003c\/li\u003e\n \u003cli\u003e115V 400Hz: Resistance 2600Ω\u003c\/li\u003e\n \u003cli\u003e125VDC: Resistance 3380Ω\u003c\/li\u003e\n \u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eContact Ratings (DPDT Contacts):\n \u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n \u003ctr\u003e\n \u003cth\u003eVoltage\u003c\/th\u003e\n \u003cth\u003eInductive (Amps)\u003c\/th\u003e\n \u003cth\u003eResistive (Amps)\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e30V DC\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e110V DC\u003c\/td\u003e\n\u003ctd\u003e0.75\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e120V 60Hz\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e120V 400Hz\u003c\/td\u003e\n\u003ctd\u003e1.5\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e240V\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003c\/table\u003e\n\u003c\/li\u003e\n\u003cli\u003eAmbient Temperature Range: -55°C to +85°C\u003c\/li\u003e\n\u003cli\u003eWeight: Max 17 ozs\u003c\/li\u003e\n\u003cli\u003eMounting Options: Chassis mounting tabs, octal plugs, external or internal adjustment, panel mounting back plate\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAdditional Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHermetically sealed models circulate air under controlled pressure for reliable timing.\u003c\/li\u003e\n\u003cli\u003eDesigned for high shock and vibration environments.\u003c\/li\u003e\n\u003cli\u003eRe-set time: 25 ms (Series 2112), 75 ms (Series 2122).\u003c\/li\u003e\n\u003cli\u003eRelay operate time: 75 ms; release time: 25 ms.\u003c\/li\u003e\n\u003cli\u003eInsensitivity to transients of ±1500 VAC for 10 milliseconds.\u003c\/li\u003e\n\u003cli\u003eDielectric withstands 1000V RMS at 60Hz between non-connected terminals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eFor more detailed specifications, please refer to the \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-ag\/2100.pdf\" target=\"_blank\"\u003edatasheet\u003c\/a\u003e. The datasheet was not processed; please search the internet for the part number for more details.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNote: The product image displayed is a standard reference image. Actual product appearance may vary. For the most accurate and up-to-date representation, we recommend searching the part number online.\u003c\/strong\u003e\u003c\/p\u003e"}