WEIDMULLER Surge Voltage Arrester - VPU AC II US 1+1 R 240/50 Y
Ensure optimal surge protection for low-voltage electrical systems with the WEIDMULLER Surge Voltage Arrester, part number 2736460000. Designed for single-phase applications, this device offers reliable surge protection with remote contact capabilities, suitable for TT, TN, and IT systems with N connections.
Product Features
Compact surge protection device suitable for installation in various electrical applications
No additional overcurrent protection devices needed
Short circuit current rating (SCCR) up to 200 kA for enhanced safety
Tested according to IEC/EN 61643-11 and UL 1449 4th Edition standards
Surge voltage category III, pollution severity 2
Remote signaling contact for status monitoring
RoHS compliant and UL certified (UL File Number: E354261)
Note: For more detailed specifications and installation instructions, please refer to the datasheet linked above. Product information is based on the provided datasheet; please search the internet for additional details if needed.
Use left/right arrows to navigate the slideshow or swipe left/right if using a mobile device
Choosing a selection results in a full page refresh.
Press the space key then arrow keys to make a selection.
Shopping Cart
{"id":10026760503613,"title":"2736460000","handle":"2736460000","description":"\u003ch3\u003eWEIDMULLER Surge Voltage Arrester - VPU AC II US 1+1 R 240\/50 Y\u003c\/h3\u003e\n\n\u003cp\u003eEnsure optimal surge protection for low-voltage electrical systems with the WEIDMULLER Surge Voltage Arrester, part number 2736460000. Designed for single-phase applications, this device offers reliable surge protection with remote contact capabilities, suitable for TT, TN, and IT systems with N connections.\u003c\/p\u003e\n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eCompact surge protection device suitable for installation in various electrical applications\u003c\/li\u003e\n \u003cli\u003eNo additional overcurrent protection devices needed\u003c\/li\u003e\n \u003cli\u003eShort circuit current rating (SCCR) up to 200 kA for enhanced safety\u003c\/li\u003e\n \u003cli\u003eTested according to IEC\/EN 61643-11 and UL 1449 4th Edition standards\u003c\/li\u003e\n \u003cli\u003eSurge voltage category III, pollution severity 2\u003c\/li\u003e\n \u003cli\u003eRemote signaling contact for status monitoring\u003c\/li\u003e\n \u003cli\u003eRoHS compliant and UL certified (UL File Number: E354261)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n \u003cth\u003eDimensions \u0026amp; Weight\u003c\/th\u003e\n \u003ctd\u003e\n \u003cul\u003e\n \u003cli\u003eDepth: 68 mm (2.677 inches)\u003c\/li\u003e\n \u003cli\u003eIncluding DIN rail: 76 mm\u003c\/li\u003e\n \u003cli\u003eHeight: 104.5 mm (4.114 inches)\u003c\/li\u003e\n \u003cli\u003eWidth: 36 mm (1.417 inches)\u003c\/li\u003e\n \u003cli\u003eMounting height: 75 mm\u003c\/li\u003e\n \u003cli\u003eNet weight: 244 g\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eOperating Conditions\u003c\/th\u003e\n \u003ctd\u003e\n \u003cul\u003e\n \u003cli\u003eStorage temperature: -40 °C to 85 °C\u003c\/li\u003e\n \u003cli\u003eOperating temperature: -40 °C to 85 °C\u003c\/li\u003e\n \u003cli\u003eHumidity: 5% to 95% relative humidity\u003c\/li\u003e\n \u003cli\u003eMaximum operating altitude: ≤ 4000 m\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eRated Data (UL)\u003c\/th\u003e\n \u003ctd\u003e\n \u003cul\u003e\n \u003cli\u003eRated Voltage U\u003csub\u003eN\u003c\/sub\u003e: 240 V\u003c\/li\u003e\n \u003cli\u003eMCOV (L-PE): 300 V\u003c\/li\u003e\n \u003cli\u003eMCOV (N-PE): 305 V\u003c\/li\u003e\n \u003cli\u003eSCCR: 150 kA\u003c\/li\u003e\n \u003cli\u003eConnection: Push-in, solid wire, min. 0.14 mm², max. 10 mm² (AWG 30- AWG 10)\u003c\/li\u003e\n \u003cli\u003eResponse time: ≤ 25 ns\u003c\/li\u003e\n \u003cli\u003eProtection level U\u003csub\u003ep\u003c\/sub\u003e at I\u003csub\u003eN\u003c\/sub\u003e: ≤ 1.3 kV (L\/N-PE), ≤ 1.5 kV (N-PE)\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eElectrical Connection\u003c\/th\u003e\n \u003ctd\u003e\n \u003cul\u003e\n \u003cli\u003eConnection type: Screw terminal\u003c\/li\u003e\n \u003cli\u003eStripping length: 18 mm\u003c\/li\u003e\n \u003cli\u003eClamping range: 4 mm² to 35 mm²\u003c\/li\u003e\n \u003cli\u003eMax. tightening torque: 4.5 Nm\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eStandards \u0026amp; Certifications\u003c\/th\u003e\n \u003ctd\u003e\n \u003cul\u003e\n \u003cli\u003eIEC 61643-11, EN 61643-11, UL 1449\u003c\/li\u003e\n \u003cli\u003eResponse time: ≤ 25 ns\u003c\/li\u003e\n \u003cli\u003eSurge voltage category: III\u003c\/li\u003e\n \u003cli\u003eRoHS compliant\u003c\/li\u003e\n \u003cli\u003eUL File Number: E354261\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eAdditional Information\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eProduct is suitable for applications requiring surge protection with remote status signaling\u003c\/li\u003e\n \u003cli\u003ePart Number: 2736460000\u003c\/li\u003e\n \u003cli\u003eManufacturer: WEIDMULLER\u003c\/li\u003e\n \u003cli\u003eCountry of Origin: SI\u003c\/li\u003e\n \u003cli\u003eUOM: EA\u003c\/li\u003e\n \u003cli\u003eECCN: EAR99\u003c\/li\u003e\n \u003cli\u003ePackage Type: PKG\u003c\/li\u003e\n \u003cli\u003eDatasheet: \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-we\/2736460000.pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e For more detailed specifications and installation instructions, please refer to the datasheet linked above. Product information is based on the provided datasheet; please search the internet for additional details if needed.\u003c\/p\u003e\u003cbr\u003e","published_at":"2025-08-15T14:52:07+05:30","created_at":"2025-08-15T14:52:08+05:30","vendor":"Waldom Electonics","type":"","tags":["IMPORT_CSV","IMPORT_PT2","WEIDM","WLDM"],"price":3414605,"price_min":3414605,"price_max":3414605,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50623082561853,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"2736460000","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"2736460000","public_title":null,"options":["Default Title"],"price":3414605,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"2736460000","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/54994808.jpg?v=1755249728"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/54994808.jpg?v=1755249728","options":["Title"],"media":[{"alt":null,"id":45851854471485,"position":1,"preview_image":{"aspect_ratio":1.0,"height":800,"width":800,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/54994808.jpg?v=1755249728"},"aspect_ratio":1.0,"height":800,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/54994808.jpg?v=1755249728","width":800}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eWEIDMULLER Surge Voltage Arrester - VPU AC II US 1+1 R 240\/50 Y\u003c\/h3\u003e\n\n\u003cp\u003eEnsure optimal surge protection for low-voltage electrical systems with the WEIDMULLER Surge Voltage Arrester, part number 2736460000. Designed for single-phase applications, this device offers reliable surge protection with remote contact capabilities, suitable for TT, TN, and IT systems with N connections.\u003c\/p\u003e\n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eCompact surge protection device suitable for installation in various electrical applications\u003c\/li\u003e\n \u003cli\u003eNo additional overcurrent protection devices needed\u003c\/li\u003e\n \u003cli\u003eShort circuit current rating (SCCR) up to 200 kA for enhanced safety\u003c\/li\u003e\n \u003cli\u003eTested according to IEC\/EN 61643-11 and UL 1449 4th Edition standards\u003c\/li\u003e\n \u003cli\u003eSurge voltage category III, pollution severity 2\u003c\/li\u003e\n \u003cli\u003eRemote signaling contact for status monitoring\u003c\/li\u003e\n \u003cli\u003eRoHS compliant and UL certified (UL File Number: E354261)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n \u003cth\u003eDimensions \u0026amp; Weight\u003c\/th\u003e\n \u003ctd\u003e\n \u003cul\u003e\n \u003cli\u003eDepth: 68 mm (2.677 inches)\u003c\/li\u003e\n \u003cli\u003eIncluding DIN rail: 76 mm\u003c\/li\u003e\n \u003cli\u003eHeight: 104.5 mm (4.114 inches)\u003c\/li\u003e\n \u003cli\u003eWidth: 36 mm (1.417 inches)\u003c\/li\u003e\n \u003cli\u003eMounting height: 75 mm\u003c\/li\u003e\n \u003cli\u003eNet weight: 244 g\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eOperating Conditions\u003c\/th\u003e\n \u003ctd\u003e\n \u003cul\u003e\n \u003cli\u003eStorage temperature: -40 °C to 85 °C\u003c\/li\u003e\n \u003cli\u003eOperating temperature: -40 °C to 85 °C\u003c\/li\u003e\n \u003cli\u003eHumidity: 5% to 95% relative humidity\u003c\/li\u003e\n \u003cli\u003eMaximum operating altitude: ≤ 4000 m\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eRated Data (UL)\u003c\/th\u003e\n \u003ctd\u003e\n \u003cul\u003e\n \u003cli\u003eRated Voltage U\u003csub\u003eN\u003c\/sub\u003e: 240 V\u003c\/li\u003e\n \u003cli\u003eMCOV (L-PE): 300 V\u003c\/li\u003e\n \u003cli\u003eMCOV (N-PE): 305 V\u003c\/li\u003e\n \u003cli\u003eSCCR: 150 kA\u003c\/li\u003e\n \u003cli\u003eConnection: Push-in, solid wire, min. 0.14 mm², max. 10 mm² (AWG 30- AWG 10)\u003c\/li\u003e\n \u003cli\u003eResponse time: ≤ 25 ns\u003c\/li\u003e\n \u003cli\u003eProtection level U\u003csub\u003ep\u003c\/sub\u003e at I\u003csub\u003eN\u003c\/sub\u003e: ≤ 1.3 kV (L\/N-PE), ≤ 1.5 kV (N-PE)\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eElectrical Connection\u003c\/th\u003e\n \u003ctd\u003e\n \u003cul\u003e\n \u003cli\u003eConnection type: Screw terminal\u003c\/li\u003e\n \u003cli\u003eStripping length: 18 mm\u003c\/li\u003e\n \u003cli\u003eClamping range: 4 mm² to 35 mm²\u003c\/li\u003e\n \u003cli\u003eMax. tightening torque: 4.5 Nm\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003cth\u003eStandards \u0026amp; Certifications\u003c\/th\u003e\n \u003ctd\u003e\n \u003cul\u003e\n \u003cli\u003eIEC 61643-11, EN 61643-11, UL 1449\u003c\/li\u003e\n \u003cli\u003eResponse time: ≤ 25 ns\u003c\/li\u003e\n \u003cli\u003eSurge voltage category: III\u003c\/li\u003e\n \u003cli\u003eRoHS compliant\u003c\/li\u003e\n \u003cli\u003eUL File Number: E354261\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eAdditional Information\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eProduct is suitable for applications requiring surge protection with remote status signaling\u003c\/li\u003e\n \u003cli\u003ePart Number: 2736460000\u003c\/li\u003e\n \u003cli\u003eManufacturer: WEIDMULLER\u003c\/li\u003e\n \u003cli\u003eCountry of Origin: SI\u003c\/li\u003e\n \u003cli\u003eUOM: EA\u003c\/li\u003e\n \u003cli\u003eECCN: EAR99\u003c\/li\u003e\n \u003cli\u003ePackage Type: PKG\u003c\/li\u003e\n \u003cli\u003eDatasheet: \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-we\/2736460000.pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e For more detailed specifications and installation instructions, please refer to the datasheet linked above. Product information is based on the provided datasheet; please search the internet for additional details if needed.\u003c\/p\u003e\u003cbr\u003e"}