TE Connectivity SENSORS - PRESS XDCR ANALOG PSI RANGE (Part Number: 4525-SS5B150AS)
Enhance your measurement systems with the TE Connectivity SENSORS PRESS XDCR ANALOG PSI RANGE, a high-performance PCB-mounted pressure transducer designed for precise pressure measurement applications. Built with proprietary UltraStable™ process technology and CMOS sensor conditioning circuitry, this transducer offers exceptional accuracy and stability in various environments.
Product Features
PSI Pressure Ranges for versatile measurement capabilities
PCB Mountable design for easy integration
High-Level Analog Output for accurate signal transmission
Barbed Pressure Ports compatible with 3/32” ID tubing
Suitable for differential, gage, absolute, and vacuum pressure measurements
Temperature compensated for reliable performance
Operates on 3.3V or 5.0V DC supply voltage
Applications
Blocked Filter Detection
Altitude and Airspeed Measurements
Medical Instruments
Fire Suppression Systems
Panel Meters
Air Movement and Environmental Controls
Pneumatic Controls
Specifications
Parameter
Conditions
Min
Typ
Max
Units
Notes
Supply Voltage
2.7
3.3 / 5.0
5.5
V DC
Output
0.500
4.500
V
Ratiometric to supply voltage
Accuracy
-0.25
0.25
%Span
Total Error Band (TEB)
-1.0
1.0
%Span
Includes all accuracy errors, thermal errors over the compensated temperature range, span, and offset calibration tolerances
Supply Current
3
mA
Long Term Stability
±0.5
%Span
Over a year with constant voltage and temperature
Operating Temperature
-25
+105
°C
Media Compatibility
Non-Corrosive Dry Gases (see wetted material chart)
Mechanical Vibration: Mil Spec 202F, Method 214A, Condition 1E, 1 Hour Each Axis
Thermal Shock: 100 Cycles over storage temperature with 30-minute dwell
Solder Temperature: 250°C for 5 seconds max
Performance
Response Time: 1 ms
Start Time to Data Ready: 5 ms
Weight: 1.43 to 2.02 grams
Additional Information
The MS4525 pressure transducer is fully calibrated, temperature compensated, and designed for OEM applications requiring high accuracy and stability. It features barbed pressure ports for secure tubing connection and can measure a wide range of pressures with various package configurations.
For detailed specifications and application guidance, please refer to the datasheet.
Datasheet was not processed please search the internet for the part number for more details.
{"id":10027875828029,"title":"4525-SS5B150AS","handle":"4525-ss5b150as","description":"\u003ch3\u003eTE Connectivity SENSORS - PRESS XDCR ANALOG PSI RANGE (Part Number: 4525-SS5B150AS)\u003c\/h3\u003e\n\u003cp\u003eEnhance your measurement systems with the TE Connectivity SENSORS PRESS XDCR ANALOG PSI RANGE, a high-performance PCB-mounted pressure transducer designed for precise pressure measurement applications. Built with proprietary UltraStable™ process technology and CMOS sensor conditioning circuitry, this transducer offers exceptional accuracy and stability in various environments.\u003c\/p\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePSI Pressure Ranges for versatile measurement capabilities\u003c\/li\u003e\n\u003cli\u003ePCB Mountable design for easy integration\u003c\/li\u003e\n\u003cli\u003eHigh-Level Analog Output for accurate signal transmission\u003c\/li\u003e\n\u003cli\u003eBarbed Pressure Ports compatible with 3\/32” ID tubing\u003c\/li\u003e\n\u003cli\u003eSuitable for differential, gage, absolute, and vacuum pressure measurements\u003c\/li\u003e\n\u003cli\u003eTemperature compensated for reliable performance\u003c\/li\u003e\n\u003cli\u003eOperates on 3.3V or 5.0V DC supply voltage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBlocked Filter Detection\u003c\/li\u003e\n\u003cli\u003eAltitude and Airspeed Measurements\u003c\/li\u003e\n\u003cli\u003eMedical Instruments\u003c\/li\u003e\n\u003cli\u003eFire Suppression Systems\u003c\/li\u003e\n\u003cli\u003ePanel Meters\u003c\/li\u003e\n\u003cli\u003eAir Movement and Environmental Controls\u003c\/li\u003e\n\u003cli\u003ePneumatic Controls\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eConditions\u003c\/th\u003e\n\u003cth\u003eMin\u003c\/th\u003e\n\u003cth\u003eTyp\u003c\/th\u003e\n\u003cth\u003eMax\u003c\/th\u003e\n\u003cth\u003eUnits\u003c\/th\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e2.7\u003c\/td\u003e\n\u003ctd\u003e3.3 \/ 5.0\u003c\/td\u003e\n\u003ctd\u003e5.5\u003c\/td\u003e\n\u003ctd\u003eV DC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.500\u003c\/td\u003e\n\u003ctd\u003e4.500\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eV\u003c\/td\u003e\n\u003ctd\u003eRatiometric to supply voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e-0.25\u003c\/td\u003e\n\u003ctd\u003e0.25\u003c\/td\u003e\n\u003ctd\u003e%Span\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Error Band (TEB)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e-1.0\u003c\/td\u003e\n\u003ctd\u003e1.0\u003c\/td\u003e\n\u003ctd\u003e%Span\u003c\/td\u003e\n\u003ctd\u003eIncludes all accuracy errors, thermal errors over the compensated temperature range, span, and offset calibration tolerances\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Current\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003emA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong Term Stability\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.5\u003c\/td\u003e\n\u003ctd\u003e%Span\u003c\/td\u003e\n\u003ctd\u003eOver a year with constant voltage and temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e-25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e+105\u003c\/td\u003e\n\u003ctd\u003e°C\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedia Compatibility\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eNon-Corrosive Dry Gases (see wetted material chart)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePressure Ranges and Package Configurations\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eRange (PSI)\u003c\/th\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003cth\u003ePackage Style\u003c\/th\u003e\n\u003cth\u003eBurst Pressure (psi)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eAbsolute, Gage, Differential, Vacuum\u003c\/td\u003e\n\u003ctd\u003eDS, SS, TP, MM\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eAbsolute, Gage, Differential, Vacuum\u003c\/td\u003e\n\u003ctd\u003eDS, SS, TP, MM\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003eAbsolute, Gage, Differential, Vacuum\u003c\/td\u003e\n\u003ctd\u003eDS, SS, TP, MM\u003c\/td\u003e\n\u003ctd\u003e15 \/ 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003eAbsolute, Gage, Differential, Vacuum\u003c\/td\u003e\n\u003ctd\u003eSS, TP\u003c\/td\u003e\n\u003ctd\u003e45 \/ 90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003eAbsolute, Gage, Differential, Vacuum\u003c\/td\u003e\n\u003ctd\u003eSS, TP\u003c\/td\u003e\n\u003ctd\u003e90 \/ 200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003eAbsolute, Gage, Differential, Vacuum\u003c\/td\u003e\n\u003ctd\u003eSS, TP\u003c\/td\u003e\n\u003ctd\u003e150 \/ 300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003ctd\u003eAbsolute, Gage, Differential, Vacuum\u003c\/td\u003e\n\u003ctd\u003eSS, TP\u003c\/td\u003e\n\u003ctd\u003e300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e150\u003c\/td\u003e\n\u003ctd\u003eAbsolute, Gage, Differential, Vacuum\u003c\/td\u003e\n\u003ctd\u003eSS, TP\u003c\/td\u003e\n\u003ctd\u003e300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEnvironmental and Mechanical Ratings\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStorage Temperature: -40°C to +125°C\u003c\/li\u003e\n\u003cli\u003eOverpressure Limit: Up to 300 psi\u003c\/li\u003e\n\u003cli\u003eBurst Pressure: Varies by range and package style\u003c\/li\u003e\n\u003cli\u003eMechanical Shock: Mil Spec 202F, Method 213B, Condition C, 3 Drops\u003c\/li\u003e\n\u003cli\u003eMechanical Vibration: Mil Spec 202F, Method 214A, Condition 1E, 1 Hour Each Axis\u003c\/li\u003e\n\u003cli\u003eThermal Shock: 100 Cycles over storage temperature with 30-minute dwell\u003c\/li\u003e\n\u003cli\u003eSolder Temperature: 250°C for 5 seconds max\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePerformance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eResponse Time: 1 ms\u003c\/li\u003e\n\u003cli\u003eStart Time to Data Ready: 5 ms\u003c\/li\u003e\n\u003cli\u003eWeight: 1.43 to 2.02 grams\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdditional Information\u003c\/h3\u003e\n\u003cp\u003eThe MS4525 pressure transducer is fully calibrated, temperature compensated, and designed for OEM applications requiring high accuracy and stability. It features barbed pressure ports for secure tubing connection and can measure a wide range of pressures with various package configurations.\u003c\/p\u003e\n\u003cp\u003eFor detailed specifications and application guidance, please refer to the \u003ca href=\"https:\/\/www.te.com\/commerce\/DocumentDelivery\/DDEController?Action=srchrtrv\u0026amp;DocNm=MS4525\u0026amp;DocType=Data+Sheet\u0026amp;DocLang=English\u0026amp;PartCntxt=4525-SS5B150AS\u0026amp;DocFormat=pdf\" target=\"_blank\"\u003edatasheet\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eDatasheet was not processed please search the internet for the part number for more details.\u003c\/p\u003e\n\u003ch3\u003ePart Number:\u003c\/h3\u003e 4525-SS5B150AS\u003cbr\u003e\n\u003ch3\u003eManufacturer:\u003c\/h3\u003e TE Connectivity SENSORS\u003cbr\u003e\n\u003ch3\u003eCountry of Origin:\u003c\/h3\u003e CN\u003cbr\u003e\n\u003ch3\u003eUnit of Measure:\u003c\/h3\u003e EA\u003cbr\u003e\n\u003ch3\u003eECCN:\u003c\/h3\u003e EAR99\u003cbr\u003e\n\u003ch3\u003ePackage Type:\u003c\/h3\u003e PKG\u003cbr\u003e","published_at":"2025-08-16T04:06:32+05:30","created_at":"2025-08-16T04:06:32+05:30","vendor":"Waldom Electonics","type":"Measurement Specialties","tags":["IMPORT_CSV","IMPORT_PT2","Measurement","TE-SENS","WLDM","XDCR"],"price":705844,"price_min":705844,"price_max":705844,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50626231468349,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"4525-SS5B150AS","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"4525-SS5B150AS","public_title":null,"options":["Default Title"],"price":705844,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"4525-SS5B150AS","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/4525-SS5B150AS_56176522_50c3de02.jpg?v=1755297395"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/4525-SS5B150AS_56176522_50c3de02.jpg?v=1755297395","options":["Title"],"media":[{"alt":null,"id":45861535318333,"position":1,"preview_image":{"aspect_ratio":1.34,"height":200,"width":268,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/4525-SS5B150AS_56176522_50c3de02.jpg?v=1755297395"},"aspect_ratio":1.34,"height":200,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/4525-SS5B150AS_56176522_50c3de02.jpg?v=1755297395","width":268}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eTE Connectivity SENSORS - PRESS XDCR ANALOG PSI RANGE (Part Number: 4525-SS5B150AS)\u003c\/h3\u003e\n\u003cp\u003eEnhance your measurement systems with the TE Connectivity SENSORS PRESS XDCR ANALOG PSI RANGE, a high-performance PCB-mounted pressure transducer designed for precise pressure measurement applications. Built with proprietary UltraStable™ process technology and CMOS sensor conditioning circuitry, this transducer offers exceptional accuracy and stability in various environments.\u003c\/p\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePSI Pressure Ranges for versatile measurement capabilities\u003c\/li\u003e\n\u003cli\u003ePCB Mountable design for easy integration\u003c\/li\u003e\n\u003cli\u003eHigh-Level Analog Output for accurate signal transmission\u003c\/li\u003e\n\u003cli\u003eBarbed Pressure Ports compatible with 3\/32” ID tubing\u003c\/li\u003e\n\u003cli\u003eSuitable for differential, gage, absolute, and vacuum pressure measurements\u003c\/li\u003e\n\u003cli\u003eTemperature compensated for reliable performance\u003c\/li\u003e\n\u003cli\u003eOperates on 3.3V or 5.0V DC supply voltage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBlocked Filter Detection\u003c\/li\u003e\n\u003cli\u003eAltitude and Airspeed Measurements\u003c\/li\u003e\n\u003cli\u003eMedical Instruments\u003c\/li\u003e\n\u003cli\u003eFire Suppression Systems\u003c\/li\u003e\n\u003cli\u003ePanel Meters\u003c\/li\u003e\n\u003cli\u003eAir Movement and Environmental Controls\u003c\/li\u003e\n\u003cli\u003ePneumatic Controls\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eConditions\u003c\/th\u003e\n\u003cth\u003eMin\u003c\/th\u003e\n\u003cth\u003eTyp\u003c\/th\u003e\n\u003cth\u003eMax\u003c\/th\u003e\n\u003cth\u003eUnits\u003c\/th\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e2.7\u003c\/td\u003e\n\u003ctd\u003e3.3 \/ 5.0\u003c\/td\u003e\n\u003ctd\u003e5.5\u003c\/td\u003e\n\u003ctd\u003eV DC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.500\u003c\/td\u003e\n\u003ctd\u003e4.500\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eV\u003c\/td\u003e\n\u003ctd\u003eRatiometric to supply voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e-0.25\u003c\/td\u003e\n\u003ctd\u003e0.25\u003c\/td\u003e\n\u003ctd\u003e%Span\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Error Band (TEB)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e-1.0\u003c\/td\u003e\n\u003ctd\u003e1.0\u003c\/td\u003e\n\u003ctd\u003e%Span\u003c\/td\u003e\n\u003ctd\u003eIncludes all accuracy errors, thermal errors over the compensated temperature range, span, and offset calibration tolerances\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Current\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003emA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong Term Stability\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.5\u003c\/td\u003e\n\u003ctd\u003e%Span\u003c\/td\u003e\n\u003ctd\u003eOver a year with constant voltage and temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e-25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e+105\u003c\/td\u003e\n\u003ctd\u003e°C\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedia Compatibility\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eNon-Corrosive Dry Gases (see wetted material chart)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePressure Ranges and Package Configurations\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eRange (PSI)\u003c\/th\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003cth\u003ePackage Style\u003c\/th\u003e\n\u003cth\u003eBurst Pressure (psi)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eAbsolute, Gage, Differential, Vacuum\u003c\/td\u003e\n\u003ctd\u003eDS, SS, TP, MM\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eAbsolute, Gage, Differential, Vacuum\u003c\/td\u003e\n\u003ctd\u003eDS, SS, TP, MM\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003eAbsolute, Gage, Differential, Vacuum\u003c\/td\u003e\n\u003ctd\u003eDS, SS, TP, MM\u003c\/td\u003e\n\u003ctd\u003e15 \/ 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003eAbsolute, Gage, Differential, Vacuum\u003c\/td\u003e\n\u003ctd\u003eSS, TP\u003c\/td\u003e\n\u003ctd\u003e45 \/ 90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003eAbsolute, Gage, Differential, Vacuum\u003c\/td\u003e\n\u003ctd\u003eSS, TP\u003c\/td\u003e\n\u003ctd\u003e90 \/ 200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003eAbsolute, Gage, Differential, Vacuum\u003c\/td\u003e\n\u003ctd\u003eSS, TP\u003c\/td\u003e\n\u003ctd\u003e150 \/ 300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003ctd\u003eAbsolute, Gage, Differential, Vacuum\u003c\/td\u003e\n\u003ctd\u003eSS, TP\u003c\/td\u003e\n\u003ctd\u003e300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e150\u003c\/td\u003e\n\u003ctd\u003eAbsolute, Gage, Differential, Vacuum\u003c\/td\u003e\n\u003ctd\u003eSS, TP\u003c\/td\u003e\n\u003ctd\u003e300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEnvironmental and Mechanical Ratings\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStorage Temperature: -40°C to +125°C\u003c\/li\u003e\n\u003cli\u003eOverpressure Limit: Up to 300 psi\u003c\/li\u003e\n\u003cli\u003eBurst Pressure: Varies by range and package style\u003c\/li\u003e\n\u003cli\u003eMechanical Shock: Mil Spec 202F, Method 213B, Condition C, 3 Drops\u003c\/li\u003e\n\u003cli\u003eMechanical Vibration: Mil Spec 202F, Method 214A, Condition 1E, 1 Hour Each Axis\u003c\/li\u003e\n\u003cli\u003eThermal Shock: 100 Cycles over storage temperature with 30-minute dwell\u003c\/li\u003e\n\u003cli\u003eSolder Temperature: 250°C for 5 seconds max\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePerformance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eResponse Time: 1 ms\u003c\/li\u003e\n\u003cli\u003eStart Time to Data Ready: 5 ms\u003c\/li\u003e\n\u003cli\u003eWeight: 1.43 to 2.02 grams\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdditional Information\u003c\/h3\u003e\n\u003cp\u003eThe MS4525 pressure transducer is fully calibrated, temperature compensated, and designed for OEM applications requiring high accuracy and stability. It features barbed pressure ports for secure tubing connection and can measure a wide range of pressures with various package configurations.\u003c\/p\u003e\n\u003cp\u003eFor detailed specifications and application guidance, please refer to the \u003ca href=\"https:\/\/www.te.com\/commerce\/DocumentDelivery\/DDEController?Action=srchrtrv\u0026amp;DocNm=MS4525\u0026amp;DocType=Data+Sheet\u0026amp;DocLang=English\u0026amp;PartCntxt=4525-SS5B150AS\u0026amp;DocFormat=pdf\" target=\"_blank\"\u003edatasheet\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eDatasheet was not processed please search the internet for the part number for more details.\u003c\/p\u003e\n\u003ch3\u003ePart Number:\u003c\/h3\u003e 4525-SS5B150AS\u003cbr\u003e\n\u003ch3\u003eManufacturer:\u003c\/h3\u003e TE Connectivity SENSORS\u003cbr\u003e\n\u003ch3\u003eCountry of Origin:\u003c\/h3\u003e CN\u003cbr\u003e\n\u003ch3\u003eUnit of Measure:\u003c\/h3\u003e EA\u003cbr\u003e\n\u003ch3\u003eECCN:\u003c\/h3\u003e EAR99\u003cbr\u003e\n\u003ch3\u003ePackage Type:\u003c\/h3\u003e PKG\u003cbr\u003e"}