Breakers hold 100% of rated current; trip between 101% and 124% (134% for AC/DC units). Trip at 125% and above (135% for AC/DC units).
Dielectric Strength
50/60 Hz., 1500V DC, 1100V AC
Insulation Resistance
100 Megaohms at 500VDC
Endurance
10,000 on/off cycles (6000 at rated load, 4000 at no load). Tested at six cycles per minute, 1 second on, 9 seconds off at 25°C ambient.
Mechanical and Environmental Data
Characteristic
Specification
Operating Temperature
-40°C to +85°C
Humidity
Meets Mil-STD-202 method 103
Shock
Tested per Mil-STD-202, method 213, test condition C (100g @ 6 ms)
Vibration
Tested per Mil-STD-202, method 201, 10-55 Hz, 0.06” total excursion in 2 planes
Fungus and Moisture Resistance
Moisture resistant finish; fungus-resistant plastic parts
Mounting
Two #6-32 screws from the front; optional metric models available. Recommended torque: 6-8 in-lb (front), 10-12 in-lb (#8-32), 14-16 in-lb (#10-32). Mount units upright within 90° of normal position.
Weight
Approximately 2.5 ounces per pole
Approval Ratings
Model Series
Voltage
Frequency
Phase
Current Rating (Amps)
Interrupting Capacity (Amps)
W6 Series
65V DC, 277V AC, 277/480V
50/60Hz
-
0.2 - 50
2,000
W9 Series
65V DC, 277V AC, 277/480V
50/60Hz
-
0.2 - 50
2,000 to 5,000 depending on configuration
VDE Approved
Various voltages including 250V and 415/240V
50/60Hz
1, 3Ø-Wye
0.2 - 50
2,000 to 5,000 depending on configuration
Trip Curves and Timing
Includes various trip curves such as instant, standard delay, short delay, and high inrush, suitable for different circuit protection needs. Refer to datasheet for detailed trip time characteristics.
Outline Dimensions
Dimensions are provided for panel mounting and toggle actuator models, with details available in the datasheet. Mounting recommended with specific torque values to ensure performance.
Additional Information
For more detailed specifications and technical data, please review the full datasheet available here.
Note: Please thoroughly review the technical data and approvals files to confirm suitability for your application.
Datasheet was not processed please search the internet for the part number for more details.
Use left/right arrows to navigate the slideshow or swipe left/right if using a mobile device
Choosing a selection results in a full page refresh.
Press the space key then arrow keys to make a selection.
Shopping Cart
{"id":10028271468861,"title":"6-1393252-9","handle":"6-1393252-9","description":"\u003ch3\u003eTE Connectivity\/AMP Brand Circuit Breakers W67-X2Q13-20 M6\/M7\/M9\/W6\/W7\u003c\/h3\u003e\n\u003cp\u003ePart Number: 6-1393252-9\u003c\/p\u003e\n\u003cp\u003eManufacturer: TE CONNECTIVITY\/AMP BRAND\u003c\/p\u003e\n\u003cp\u003eCountry of Origin: CN\u003c\/p\u003e\n\u003cp\u003eUnit of Measure: EA\u003c\/p\u003e\n\u003cp\u003eECCN: EAR99\u003c\/p\u003e\n\u003cp\u003ePackage Type: TRAY\u003c\/p\u003e\n\u003cp\u003eProduct Category: Circuit Protection | Circuit Breakers\u003c\/p\u003e\n\u003cp\u003eProduct Type: Circuit Protection\u003c\/p\u003e\n\u003cp\u003eDatasheet: \u003ca href=\"https:\/\/www.te.com\/commerce\/DocumentDelivery\/DDEController?Action=srchrtrv\u0026amp;DocNm=1308242_w6w9\u0026amp;DocType=Data+Sheet\u0026amp;DocLang=English\u0026amp;PartCntxt=6-1393252-9\u0026amp;DocFormat=pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for the international market with UL Recognized (UL1077), CSA accepted, and VDE approved certifications.\u003c\/li\u003e\n\u003cli\u003eRatings up to 50 Amps, suitable for a wide range of applications.\u003c\/li\u003e\n\u003cli\u003eHeavy-duty #10-32 stud connections (W9 model).\u003c\/li\u003e\n\u003cli\u003eQuick-connect or screw terminal options (W6 model).\u003c\/li\u003e\n\u003cli\u003eMultiple delay curve options for flexible circuit protection.\u003c\/li\u003e\n\u003cli\u003eTrip-free operation ensures reliable circuit interruption.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eElectrical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eBreakers hold 100% of rated current; trip between 101% and 124% (134% for AC\/DC units). Trip at 125% and above (135% for AC\/DC units).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz., 1500V DC, 1100V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e100 Megaohms at 500VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEndurance\u003c\/td\u003e\n\u003ctd\u003e10,000 on\/off cycles (6000 at rated load, 4000 at no load). Tested at six cycles per minute, 1 second on, 9 seconds off at 25°C ambient.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eMechanical and Environmental Data\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003eMeets Mil-STD-202 method 103\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd\u003eTested per Mil-STD-202, method 213, test condition C (100g @ 6 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003eTested per Mil-STD-202, method 201, 10-55 Hz, 0.06” total excursion in 2 planes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFungus and Moisture Resistance\u003c\/td\u003e\n\u003ctd\u003eMoisture resistant finish; fungus-resistant plastic parts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eTwo #6-32 screws from the front; optional metric models available. Recommended torque: 6-8 in-lb (front), 10-12 in-lb (#8-32), 14-16 in-lb (#10-32). Mount units upright within 90° of normal position.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 2.5 ounces per pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApproval Ratings\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Series\u003c\/th\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003cth\u003ePhase\u003c\/th\u003e\n\u003cth\u003eCurrent Rating (Amps)\u003c\/th\u003e\n\u003cth\u003eInterrupting Capacity (Amps)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eW6 Series\u003c\/td\u003e\n\u003ctd\u003e65V DC, 277V AC, 277\/480V\u003c\/td\u003e\n\u003ctd\u003e50\/60Hz\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e0.2 - 50\u003c\/td\u003e\n\u003ctd\u003e2,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eW9 Series\u003c\/td\u003e\n\u003ctd\u003e65V DC, 277V AC, 277\/480V\u003c\/td\u003e\n\u003ctd\u003e50\/60Hz\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e0.2 - 50\u003c\/td\u003e\n\u003ctd\u003e2,000 to 5,000 depending on configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVDE Approved\u003c\/td\u003e\n\u003ctd\u003eVarious voltages including 250V and 415\/240V\u003c\/td\u003e\n\u003ctd\u003e50\/60Hz\u003c\/td\u003e\n\u003ctd\u003e1, 3Ø-Wye\u003c\/td\u003e\n\u003ctd\u003e0.2 - 50\u003c\/td\u003e\n\u003ctd\u003e2,000 to 5,000 depending on configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTrip Curves and Timing\u003c\/h3\u003e\n\u003cp\u003eIncludes various trip curves such as instant, standard delay, short delay, and high inrush, suitable for different circuit protection needs. Refer to datasheet for detailed trip time characteristics.\u003c\/p\u003e\n\n\u003ch3\u003eOutline Dimensions\u003c\/h3\u003e\n\u003cp\u003eDimensions are provided for panel mounting and toggle actuator models, with details available in the datasheet. Mounting recommended with specific torque values to ensure performance.\u003c\/p\u003e\n\n\u003ch3\u003eAdditional Information\u003c\/h3\u003e\n\u003cp\u003eFor more detailed specifications and technical data, please review the full datasheet available \u003ca href=\"https:\/\/www.te.com\/commerce\/DocumentDelivery\/DDEController?Action=srchrtrv\u0026amp;DocNm=1308242_w6w9\u0026amp;DocType=Data+Sheet\u0026amp;DocLang=English\u0026amp;PartCntxt=6-1393252-9\u0026amp;DocFormat=pdf\" target=\"_blank\"\u003ehere\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cp\u003eNote: Please thoroughly review the technical data and approvals files to confirm suitability for your application.\u003c\/p\u003e\n\n\u003cp\u003eDatasheet was not processed please search the internet for the part number for more details.\u003c\/p\u003e\u003cbr\u003e","published_at":"2025-08-16T08:51:03+05:30","created_at":"2025-08-16T08:51:03+05:30","vendor":"Waldom Electonics","type":"Circuit Protection","tags":["Circuit","IMPORT_CSV","IMPORT_PT2","TE-AMP","WLDM"],"price":671473,"price_min":671473,"price_max":671473,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50627065053501,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"6-1393252-9","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"6-1393252-9","public_title":null,"options":["Default Title"],"price":671473,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"6-1393252-9","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/6-1393252-9_10438311_cfbf5ca0.jpg?v=1755314467"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/6-1393252-9_10438311_cfbf5ca0.jpg?v=1755314467","options":["Title"],"media":[{"alt":null,"id":45865939501373,"position":1,"preview_image":{"aspect_ratio":1.755,"height":200,"width":351,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/6-1393252-9_10438311_cfbf5ca0.jpg?v=1755314467"},"aspect_ratio":1.755,"height":200,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/6-1393252-9_10438311_cfbf5ca0.jpg?v=1755314467","width":351}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eTE Connectivity\/AMP Brand Circuit Breakers W67-X2Q13-20 M6\/M7\/M9\/W6\/W7\u003c\/h3\u003e\n\u003cp\u003ePart Number: 6-1393252-9\u003c\/p\u003e\n\u003cp\u003eManufacturer: TE CONNECTIVITY\/AMP BRAND\u003c\/p\u003e\n\u003cp\u003eCountry of Origin: CN\u003c\/p\u003e\n\u003cp\u003eUnit of Measure: EA\u003c\/p\u003e\n\u003cp\u003eECCN: EAR99\u003c\/p\u003e\n\u003cp\u003ePackage Type: TRAY\u003c\/p\u003e\n\u003cp\u003eProduct Category: Circuit Protection | Circuit Breakers\u003c\/p\u003e\n\u003cp\u003eProduct Type: Circuit Protection\u003c\/p\u003e\n\u003cp\u003eDatasheet: \u003ca href=\"https:\/\/www.te.com\/commerce\/DocumentDelivery\/DDEController?Action=srchrtrv\u0026amp;DocNm=1308242_w6w9\u0026amp;DocType=Data+Sheet\u0026amp;DocLang=English\u0026amp;PartCntxt=6-1393252-9\u0026amp;DocFormat=pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for the international market with UL Recognized (UL1077), CSA accepted, and VDE approved certifications.\u003c\/li\u003e\n\u003cli\u003eRatings up to 50 Amps, suitable for a wide range of applications.\u003c\/li\u003e\n\u003cli\u003eHeavy-duty #10-32 stud connections (W9 model).\u003c\/li\u003e\n\u003cli\u003eQuick-connect or screw terminal options (W6 model).\u003c\/li\u003e\n\u003cli\u003eMultiple delay curve options for flexible circuit protection.\u003c\/li\u003e\n\u003cli\u003eTrip-free operation ensures reliable circuit interruption.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eElectrical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eBreakers hold 100% of rated current; trip between 101% and 124% (134% for AC\/DC units). Trip at 125% and above (135% for AC\/DC units).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz., 1500V DC, 1100V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e100 Megaohms at 500VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEndurance\u003c\/td\u003e\n\u003ctd\u003e10,000 on\/off cycles (6000 at rated load, 4000 at no load). Tested at six cycles per minute, 1 second on, 9 seconds off at 25°C ambient.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eMechanical and Environmental Data\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003eMeets Mil-STD-202 method 103\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd\u003eTested per Mil-STD-202, method 213, test condition C (100g @ 6 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003eTested per Mil-STD-202, method 201, 10-55 Hz, 0.06” total excursion in 2 planes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFungus and Moisture Resistance\u003c\/td\u003e\n\u003ctd\u003eMoisture resistant finish; fungus-resistant plastic parts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eTwo #6-32 screws from the front; optional metric models available. Recommended torque: 6-8 in-lb (front), 10-12 in-lb (#8-32), 14-16 in-lb (#10-32). Mount units upright within 90° of normal position.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 2.5 ounces per pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApproval Ratings\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Series\u003c\/th\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003cth\u003ePhase\u003c\/th\u003e\n\u003cth\u003eCurrent Rating (Amps)\u003c\/th\u003e\n\u003cth\u003eInterrupting Capacity (Amps)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eW6 Series\u003c\/td\u003e\n\u003ctd\u003e65V DC, 277V AC, 277\/480V\u003c\/td\u003e\n\u003ctd\u003e50\/60Hz\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e0.2 - 50\u003c\/td\u003e\n\u003ctd\u003e2,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eW9 Series\u003c\/td\u003e\n\u003ctd\u003e65V DC, 277V AC, 277\/480V\u003c\/td\u003e\n\u003ctd\u003e50\/60Hz\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e0.2 - 50\u003c\/td\u003e\n\u003ctd\u003e2,000 to 5,000 depending on configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVDE Approved\u003c\/td\u003e\n\u003ctd\u003eVarious voltages including 250V and 415\/240V\u003c\/td\u003e\n\u003ctd\u003e50\/60Hz\u003c\/td\u003e\n\u003ctd\u003e1, 3Ø-Wye\u003c\/td\u003e\n\u003ctd\u003e0.2 - 50\u003c\/td\u003e\n\u003ctd\u003e2,000 to 5,000 depending on configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTrip Curves and Timing\u003c\/h3\u003e\n\u003cp\u003eIncludes various trip curves such as instant, standard delay, short delay, and high inrush, suitable for different circuit protection needs. Refer to datasheet for detailed trip time characteristics.\u003c\/p\u003e\n\n\u003ch3\u003eOutline Dimensions\u003c\/h3\u003e\n\u003cp\u003eDimensions are provided for panel mounting and toggle actuator models, with details available in the datasheet. Mounting recommended with specific torque values to ensure performance.\u003c\/p\u003e\n\n\u003ch3\u003eAdditional Information\u003c\/h3\u003e\n\u003cp\u003eFor more detailed specifications and technical data, please review the full datasheet available \u003ca href=\"https:\/\/www.te.com\/commerce\/DocumentDelivery\/DDEController?Action=srchrtrv\u0026amp;DocNm=1308242_w6w9\u0026amp;DocType=Data+Sheet\u0026amp;DocLang=English\u0026amp;PartCntxt=6-1393252-9\u0026amp;DocFormat=pdf\" target=\"_blank\"\u003ehere\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cp\u003eNote: Please thoroughly review the technical data and approvals files to confirm suitability for your application.\u003c\/p\u003e\n\n\u003cp\u003eDatasheet was not processed please search the internet for the part number for more details.\u003c\/p\u003e\u003cbr\u003e"}