The HONEYWELL AWM3200V is a high-precision airflow sensor designed for accurate mass airflow measurement in various applications. This sensor features amplified microbridge technology, enabling enhanced gain and voltage offset adjustments for improved performance and interchangeability.
Microbridge mass airflow sensing with amplified output for increased sensitivity
Flow sensing capability up to 1.0 SLPM
Low differential pressure sensing for precise measurements
Laser-trimmed for improved sensor interchangeability
On-board heater control and sensing bridge supply circuitry
Ratiometric output voltage relative to supply voltage
Suitable for applications requiring accurate airflow detection and control
Specifications
Performance Characteristics
Values
Flow Range
Up to 1.0 SLPM
Operating Temperature
-25°C to +85°C
Storage Temperature
-40°C to +90°C
Warm-up Time
Maximum 1 minute
Output Voltage
Ratiometric to supply voltage (10.01 ± 0.01 VDC)
Maximum Flow Rate Change
5 SLPM per 1 second
Mounting and Handling
Positive flow direction from Port 1 (P1) to Port 2 (P2)
Do not exert forces exceeding 10 lbs. in any direction
Mounting dimensions are provided for reference only
Additional Notes
Initial warm-up time for signal conditioned circuitry is up to 1 minute
Output load should be connected from V OUT to GND (current sinking)
Use a 5-micron filter on differential pressure sensors for optimal performance
For more detailed technical information, please refer to the datasheet. Please search the internet for the part number AWM3200V for additional details.
Use left/right arrows to navigate the slideshow or swipe left/right if using a mobile device
Choosing a selection results in a full page refresh.
Press the space key then arrow keys to make a selection.
Shopping Cart
{"id":10026849468733,"title":"AWM3200V","handle":"awm3200v","description":"\u003ch3\u003eHONEYWELL AWM3200V Sensor Airflow Amplified\u003c\/h3\u003e\n\u003cp\u003eThe HONEYWELL AWM3200V is a high-precision airflow sensor designed for accurate mass airflow measurement in various applications. This sensor features amplified microbridge technology, enabling enhanced gain and voltage offset adjustments for improved performance and interchangeability.\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e AWM3200V\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e HONEYWELL\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eCountry of Origin (COO):\u003c\/strong\u003e CN\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eUnit of Measure (UOM):\u003c\/strong\u003e EA\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e EAR99\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003ePackage Type:\u003c\/strong\u003e BLK\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eDatasheet:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-mr\/mr-awm3200v.pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eMicrobridge mass airflow sensing with amplified output for increased sensitivity\u003c\/li\u003e\n \u003cli\u003eFlow sensing capability up to 1.0 SLPM\u003c\/li\u003e\n \u003cli\u003eLow differential pressure sensing for precise measurements\u003c\/li\u003e\n \u003cli\u003eLaser-trimmed for improved sensor interchangeability\u003c\/li\u003e\n \u003cli\u003eOn-board heater control and sensing bridge supply circuitry\u003c\/li\u003e\n \u003cli\u003eRatiometric output voltage relative to supply voltage\u003c\/li\u003e\n \u003cli\u003eSuitable for applications requiring accurate airflow detection and control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n \u003ctr\u003e\n \u003cth\u003ePerformance Characteristics\u003c\/th\u003e\n \u003cth\u003eValues\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eFlow Range\u003c\/td\u003e\n \u003ctd\u003eUp to 1.0 SLPM\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n \u003ctd\u003e-25°C to +85°C\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n \u003ctd\u003e-40°C to +90°C\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eWarm-up Time\u003c\/td\u003e\n \u003ctd\u003eMaximum 1 minute\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eOutput Voltage\u003c\/td\u003e\n \u003ctd\u003eRatiometric to supply voltage (10.01 ± 0.01 VDC)\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eMaximum Flow Rate Change\u003c\/td\u003e\n \u003ctd\u003e5 SLPM per 1 second\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMounting and Handling\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003ePositive flow direction from Port 1 (P1) to Port 2 (P2)\u003c\/li\u003e\n \u003cli\u003eDo not exert forces exceeding 10 lbs. in any direction\u003c\/li\u003e\n \u003cli\u003eMounting dimensions are provided for reference only\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdditional Notes\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eInitial warm-up time for signal conditioned circuitry is up to 1 minute\u003c\/li\u003e\n \u003cli\u003eOutput load should be connected from V OUT to GND (current sinking)\u003c\/li\u003e\n \u003cli\u003eUse a 5-micron filter on differential pressure sensors for optimal performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor more detailed technical information, please refer to the \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-mr\/mr-awm3200v.pdf\" target=\"_blank\"\u003edatasheet\u003c\/a\u003e. Please search the internet for the part number AWM3200V for additional details.\u003c\/p\u003e\u003cbr\u003e","published_at":"2025-08-15T16:49:41+05:30","created_at":"2025-08-15T16:49:42+05:30","vendor":"Waldom Electonics","type":"Sensors\/Transducers","tags":["AMP","Flow","HWLL","IMPORT_CSV","IMPORT_PT2","Sensors","Transducers","WLDM"],"price":2413978,"price_min":2413978,"price_max":2413978,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50623229133117,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"AWM3200V","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"AWM3200V","public_title":null,"options":["Default Title"],"price":2413978,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"AWM3200V","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/11928756.jpg?v=1755256782"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/11928756.jpg?v=1755256782","options":["Title"],"media":[{"alt":null,"id":45853020586301,"position":1,"preview_image":{"aspect_ratio":1.0,"height":640,"width":640,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/11928756.jpg?v=1755256782"},"aspect_ratio":1.0,"height":640,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/11928756.jpg?v=1755256782","width":640}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eHONEYWELL AWM3200V Sensor Airflow Amplified\u003c\/h3\u003e\n\u003cp\u003eThe HONEYWELL AWM3200V is a high-precision airflow sensor designed for accurate mass airflow measurement in various applications. This sensor features amplified microbridge technology, enabling enhanced gain and voltage offset adjustments for improved performance and interchangeability.\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e AWM3200V\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e HONEYWELL\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eCountry of Origin (COO):\u003c\/strong\u003e CN\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eUnit of Measure (UOM):\u003c\/strong\u003e EA\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e EAR99\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003ePackage Type:\u003c\/strong\u003e BLK\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eDatasheet:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-mr\/mr-awm3200v.pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eMicrobridge mass airflow sensing with amplified output for increased sensitivity\u003c\/li\u003e\n \u003cli\u003eFlow sensing capability up to 1.0 SLPM\u003c\/li\u003e\n \u003cli\u003eLow differential pressure sensing for precise measurements\u003c\/li\u003e\n \u003cli\u003eLaser-trimmed for improved sensor interchangeability\u003c\/li\u003e\n \u003cli\u003eOn-board heater control and sensing bridge supply circuitry\u003c\/li\u003e\n \u003cli\u003eRatiometric output voltage relative to supply voltage\u003c\/li\u003e\n \u003cli\u003eSuitable for applications requiring accurate airflow detection and control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n \u003ctr\u003e\n \u003cth\u003ePerformance Characteristics\u003c\/th\u003e\n \u003cth\u003eValues\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eFlow Range\u003c\/td\u003e\n \u003ctd\u003eUp to 1.0 SLPM\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n \u003ctd\u003e-25°C to +85°C\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n \u003ctd\u003e-40°C to +90°C\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eWarm-up Time\u003c\/td\u003e\n \u003ctd\u003eMaximum 1 minute\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eOutput Voltage\u003c\/td\u003e\n \u003ctd\u003eRatiometric to supply voltage (10.01 ± 0.01 VDC)\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eMaximum Flow Rate Change\u003c\/td\u003e\n \u003ctd\u003e5 SLPM per 1 second\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMounting and Handling\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003ePositive flow direction from Port 1 (P1) to Port 2 (P2)\u003c\/li\u003e\n \u003cli\u003eDo not exert forces exceeding 10 lbs. in any direction\u003c\/li\u003e\n \u003cli\u003eMounting dimensions are provided for reference only\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdditional Notes\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eInitial warm-up time for signal conditioned circuitry is up to 1 minute\u003c\/li\u003e\n \u003cli\u003eOutput load should be connected from V OUT to GND (current sinking)\u003c\/li\u003e\n \u003cli\u003eUse a 5-micron filter on differential pressure sensors for optimal performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor more detailed technical information, please refer to the \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-mr\/mr-awm3200v.pdf\" target=\"_blank\"\u003edatasheet\u003c\/a\u003e. Please search the internet for the part number AWM3200V for additional details.\u003c\/p\u003e\u003cbr\u003e"}