Part Number: G7L 5158E
Manufacturer: OMRON ELECTRONIC COMPONENTS
Country of Origin: Indonesia (ID)
Unit of Measure: Each (EA)
ECCN: EAR99
Package Type: Not specified
Datasheet: Download Datasheet
Product Features
General purpose relay ideally suited for high-inrush fluid pump controls such as pools, spas, water processing, emergency systems, and chemical industries.
High-capacity, high withstand voltage relay with no contact chattering during momentary voltage drops up to 50% of rated voltage.
UL Class B construction standard ensures safety and reliability.
Wide-range AC-activated coil handling 100 to 120 VAC or 200 to 240 VAC at 50 or 60 Hz.
Miniature size design maximizes switching capacity, especially for inductive loads.
Flame resistant materials (UL94V-0-qualifying) used for all insulation components.
Multiple mounting options available: quick-connect, screw, PCB terminals, and DIN track mounting.
Conforms to UL, CSA, TUV standards and IEC 950 compliance.
Safety contact gap of 3 mm enhances operational safety.
RoHS compliant for environmentally conscious applications.
Technical Specifications
Contact Data
Load
G7L-1A-T, G7L-1A-B @
Col3
G7L-2A-T, G7L-2A-B @
Col5
G7L-1A-P, G7L-2A-P
Col7
Resistive load (cos = 1)
30 A, 220 VAC
—
25 A, 220 VAC
—
20 A, 220 VAC
—
Contact Type
Double break
Contact material
Ag alloy
Carry current
30 A
25 A
20 A
Max. operating voltage
250 VAC
Max. operating current
30 A
25 A
20 A
Max. switching capacity
6,600 VA
5,500 VA
4,400 VA
Min. permissible load
100 mA, 5 VDC (@ 60 operations/min)
Note: Not suitable for microloads such as signals.
{"id":10024508981565,"title":"G7L 5158E","handle":"g7l-5158e","description":"\u003ch3\u003eOMRON ELECTRONIC COMPONENTS G7L Series Relay\u003c\/h3\u003e\n\u003cp\u003ePart Number: G7L 5158E\u003cbr\u003e\nManufacturer: OMRON ELECTRONIC COMPONENTS\u003cbr\u003e\nCountry of Origin: Indonesia (ID)\u003cbr\u003e\nUnit of Measure: Each (EA)\u003cbr\u003e\nECCN: EAR99\u003cbr\u003e\nPackage Type: Not specified\u003cbr\u003e\nDatasheet: \u003ca href=\"https:\/\/4donline.ihs.com\/images\/VipMasterIC\/IC\/OMRN\/OMRN-S-A0001359891\/OMRN-S-A0001359891-1.pdf?hkey=82A29B72BDB3BD67C626B77C2F032848\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGeneral purpose relay ideally suited for high-inrush fluid pump controls such as pools, spas, water processing, emergency systems, and chemical industries.\u003c\/li\u003e\n\u003cli\u003eHigh-capacity, high withstand voltage relay with no contact chattering during momentary voltage drops up to 50% of rated voltage.\u003c\/li\u003e\n\u003cli\u003eUL Class B construction standard ensures safety and reliability.\u003c\/li\u003e\n\u003cli\u003eWide-range AC-activated coil handling 100 to 120 VAC or 200 to 240 VAC at 50 or 60 Hz.\u003c\/li\u003e\n\u003cli\u003eMiniature size design maximizes switching capacity, especially for inductive loads.\u003c\/li\u003e\n\u003cli\u003eFlame resistant materials (UL94V-0-qualifying) used for all insulation components.\u003c\/li\u003e\n\u003cli\u003eMultiple mounting options available: quick-connect, screw, PCB terminals, and DIN track mounting.\u003c\/li\u003e\n\u003cli\u003eConforms to UL, CSA, TUV standards and IEC 950 compliance.\u003c\/li\u003e\n\u003cli\u003eSafety contact gap of 3 mm enhances operational safety.\u003c\/li\u003e\n\u003cli\u003eRoHS compliant for environmentally conscious applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eContact Data\u003c\/h4\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctr\u003e\n\u003cth\u003eLoad\u003c\/th\u003e\n\u003cth\u003eG7L-1A-T, G7L-1A-B @\u003c\/th\u003e\n\u003cth\u003eCol3\u003c\/th\u003e\n\u003cth\u003eG7L-2A-T, G7L-2A-B @\u003c\/th\u003e\n\u003cth\u003eCol5\u003c\/th\u003e\n\u003cth\u003eG7L-1A-P, G7L-2A-P\u003c\/th\u003e\n\u003cth\u003eCol7\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistive load (cos = 1)\u003c\/td\u003e\n\u003ctd\u003e30 A, 220 VAC\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e25 A, 220 VAC\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e20 A, 220 VAC\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Type\u003c\/td\u003e\n\u003ctd\u003eDouble break\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact material\u003c\/td\u003e\n\u003ctd\u003eAg alloy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarry current\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. operating voltage\u003c\/td\u003e\n\u003ctd\u003e250 VAC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. operating current\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. switching capacity\u003c\/td\u003e\n\u003ctd\u003e6,600 VA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e5,500 VA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e4,400 VA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. permissible load\u003c\/td\u003e\n\u003ctd\u003e100 mA, 5 VDC (@ 60 operations\/min)\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003eNote: Not suitable for microloads such as signals.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eCoil Data\u003c\/h4\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctr\u003e\n\u003cth\u003eAC\u003c\/th\u003e\n\u003cth\u003eRated voltage (V)\u003c\/th\u003e\n\u003cth\u003eRated current (mA)\u003c\/th\u003e\n\u003cth\u003eResistance (Ω)\u003c\/th\u003e\n\u003cth\u003eMust operate\u003c\/th\u003e\n\u003cth\u003eMust release\u003c\/th\u003e\n\u003cth\u003eMax. voltage\u003c\/th\u003e\n\u003cth\u003ePower consumption\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e142\u003c\/td\u003e\n\u003ctd\u003e75\u003c\/td\u003e\n\u003ctd\u003e75\u003c\/td\u003e\n\u003ctd\u003e75% max.\u003c\/td\u003e\n\u003ctd\u003e15% min.\u003c\/td\u003e\n\u003ctd\u003e110%\u003c\/td\u003e\n\u003ctd\u003eApprox. 1.70 to 2.50 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e71\u003c\/td\u003e\n\u003ctd\u003e303\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003e34\u003c\/td\u003e\n\u003ctd\u003e1310\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 to 120\u003c\/td\u003e\n\u003ctd\u003e17.00 to 20.40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e5,260\u003c\/td\u003e\n\u003ctd\u003e75 volts max.\u003c\/td\u003e\n\u003ctd\u003e18 volts min.\u003c\/td\u003e\n\u003ctd\u003e132 volts\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200 to 240\u003c\/td\u003e\n\u003ctd\u003e8.50 to 10.20\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e21,000\u003c\/td\u003e\n\u003ctd\u003e150 volts max.\u003c\/td\u003e\n\u003ctd\u003e36 volts min.\u003c\/td\u003e\n\u003ctd\u003e264 volts\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eEnvironmental \u0026amp; Mechanical Durability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eOperate time: max 30 ms\u003c\/li\u003e\n\u003cli\u003eRelease time: max 30 ms\u003c\/li\u003e\n\u003cli\u003eMechanical durability: 1,000,000 operations minimum\u003c\/li\u003e\n\u003cli\u003eElectrical durability: 100,000 operations minimum at rated load\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -25°C to 60°C\u003c\/li\u003e\n\u003cli\u003eHumidity: 5% to 85% RH\u003c\/li\u003e\n\u003cli\u003eVibration and shock resistance: Meets industry standards for durability\u003c\/li\u003e\n\u003cli\u003eWeight: Quick-connect type approx. 90 g, PCB approx. 100 g, Screw approx. 120 g\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAdditional Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConforms to UL, CSA, TUV standards and IEC 950.\u003c\/li\u003e\n\u003cli\u003eRoHS compliant.\u003c\/li\u003e\n\u003cli\u003eAccessories such as E-brackets, adapters, sockets, and covers are sold separately.\u003c\/li\u003e\n\u003cli\u003eFor VDE approved versions, please consult OMRON.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eNote\u003c\/h3\u003e\n\u003cp\u003eDatasheet was not processed please search the internet for the part number for more details.\u003c\/p\u003e\u003cbr\u003e","published_at":"2025-08-14T07:28:10+05:30","created_at":"2025-08-14T07:28:10+05:30","vendor":"Waldom Electonics","type":"Relays","tags":["IMPORT_CSV","OMRON-ELE","Relay","WLDM"],"price":141640,"price_min":141640,"price_max":141640,"available":false,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50618540949821,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"G7L 5158E","requires_shipping":true,"taxable":true,"featured_image":null,"available":false,"name":"G7L 5158E","public_title":null,"options":["Default Title"],"price":141640,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"G7L 5158E","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/54489265.jpg?v=1755136692"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/54489265.jpg?v=1755136692","options":["Title"],"media":[{"alt":null,"id":45829443354941,"position":1,"preview_image":{"aspect_ratio":1.0,"height":640,"width":640,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/54489265.jpg?v=1755136692"},"aspect_ratio":1.0,"height":640,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/54489265.jpg?v=1755136692","width":640}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eOMRON ELECTRONIC COMPONENTS G7L Series Relay\u003c\/h3\u003e\n\u003cp\u003ePart Number: G7L 5158E\u003cbr\u003e\nManufacturer: OMRON ELECTRONIC COMPONENTS\u003cbr\u003e\nCountry of Origin: Indonesia (ID)\u003cbr\u003e\nUnit of Measure: Each (EA)\u003cbr\u003e\nECCN: EAR99\u003cbr\u003e\nPackage Type: Not specified\u003cbr\u003e\nDatasheet: \u003ca href=\"https:\/\/4donline.ihs.com\/images\/VipMasterIC\/IC\/OMRN\/OMRN-S-A0001359891\/OMRN-S-A0001359891-1.pdf?hkey=82A29B72BDB3BD67C626B77C2F032848\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGeneral purpose relay ideally suited for high-inrush fluid pump controls such as pools, spas, water processing, emergency systems, and chemical industries.\u003c\/li\u003e\n\u003cli\u003eHigh-capacity, high withstand voltage relay with no contact chattering during momentary voltage drops up to 50% of rated voltage.\u003c\/li\u003e\n\u003cli\u003eUL Class B construction standard ensures safety and reliability.\u003c\/li\u003e\n\u003cli\u003eWide-range AC-activated coil handling 100 to 120 VAC or 200 to 240 VAC at 50 or 60 Hz.\u003c\/li\u003e\n\u003cli\u003eMiniature size design maximizes switching capacity, especially for inductive loads.\u003c\/li\u003e\n\u003cli\u003eFlame resistant materials (UL94V-0-qualifying) used for all insulation components.\u003c\/li\u003e\n\u003cli\u003eMultiple mounting options available: quick-connect, screw, PCB terminals, and DIN track mounting.\u003c\/li\u003e\n\u003cli\u003eConforms to UL, CSA, TUV standards and IEC 950 compliance.\u003c\/li\u003e\n\u003cli\u003eSafety contact gap of 3 mm enhances operational safety.\u003c\/li\u003e\n\u003cli\u003eRoHS compliant for environmentally conscious applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eContact Data\u003c\/h4\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctr\u003e\n\u003cth\u003eLoad\u003c\/th\u003e\n\u003cth\u003eG7L-1A-T, G7L-1A-B @\u003c\/th\u003e\n\u003cth\u003eCol3\u003c\/th\u003e\n\u003cth\u003eG7L-2A-T, G7L-2A-B @\u003c\/th\u003e\n\u003cth\u003eCol5\u003c\/th\u003e\n\u003cth\u003eG7L-1A-P, G7L-2A-P\u003c\/th\u003e\n\u003cth\u003eCol7\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistive load (cos = 1)\u003c\/td\u003e\n\u003ctd\u003e30 A, 220 VAC\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e25 A, 220 VAC\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e20 A, 220 VAC\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Type\u003c\/td\u003e\n\u003ctd\u003eDouble break\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact material\u003c\/td\u003e\n\u003ctd\u003eAg alloy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarry current\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. operating voltage\u003c\/td\u003e\n\u003ctd\u003e250 VAC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. operating current\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. switching capacity\u003c\/td\u003e\n\u003ctd\u003e6,600 VA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e5,500 VA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e4,400 VA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. permissible load\u003c\/td\u003e\n\u003ctd\u003e100 mA, 5 VDC (@ 60 operations\/min)\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003eNote: Not suitable for microloads such as signals.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eCoil Data\u003c\/h4\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctr\u003e\n\u003cth\u003eAC\u003c\/th\u003e\n\u003cth\u003eRated voltage (V)\u003c\/th\u003e\n\u003cth\u003eRated current (mA)\u003c\/th\u003e\n\u003cth\u003eResistance (Ω)\u003c\/th\u003e\n\u003cth\u003eMust operate\u003c\/th\u003e\n\u003cth\u003eMust release\u003c\/th\u003e\n\u003cth\u003eMax. voltage\u003c\/th\u003e\n\u003cth\u003ePower consumption\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e142\u003c\/td\u003e\n\u003ctd\u003e75\u003c\/td\u003e\n\u003ctd\u003e75\u003c\/td\u003e\n\u003ctd\u003e75% max.\u003c\/td\u003e\n\u003ctd\u003e15% min.\u003c\/td\u003e\n\u003ctd\u003e110%\u003c\/td\u003e\n\u003ctd\u003eApprox. 1.70 to 2.50 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e71\u003c\/td\u003e\n\u003ctd\u003e303\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003e34\u003c\/td\u003e\n\u003ctd\u003e1310\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 to 120\u003c\/td\u003e\n\u003ctd\u003e17.00 to 20.40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e5,260\u003c\/td\u003e\n\u003ctd\u003e75 volts max.\u003c\/td\u003e\n\u003ctd\u003e18 volts min.\u003c\/td\u003e\n\u003ctd\u003e132 volts\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200 to 240\u003c\/td\u003e\n\u003ctd\u003e8.50 to 10.20\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e21,000\u003c\/td\u003e\n\u003ctd\u003e150 volts max.\u003c\/td\u003e\n\u003ctd\u003e36 volts min.\u003c\/td\u003e\n\u003ctd\u003e264 volts\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eEnvironmental \u0026amp; Mechanical Durability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eOperate time: max 30 ms\u003c\/li\u003e\n\u003cli\u003eRelease time: max 30 ms\u003c\/li\u003e\n\u003cli\u003eMechanical durability: 1,000,000 operations minimum\u003c\/li\u003e\n\u003cli\u003eElectrical durability: 100,000 operations minimum at rated load\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -25°C to 60°C\u003c\/li\u003e\n\u003cli\u003eHumidity: 5% to 85% RH\u003c\/li\u003e\n\u003cli\u003eVibration and shock resistance: Meets industry standards for durability\u003c\/li\u003e\n\u003cli\u003eWeight: Quick-connect type approx. 90 g, PCB approx. 100 g, Screw approx. 120 g\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAdditional Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConforms to UL, CSA, TUV standards and IEC 950.\u003c\/li\u003e\n\u003cli\u003eRoHS compliant.\u003c\/li\u003e\n\u003cli\u003eAccessories such as E-brackets, adapters, sockets, and covers are sold separately.\u003c\/li\u003e\n\u003cli\u003eFor VDE approved versions, please consult OMRON.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eNote\u003c\/h3\u003e\n\u003cp\u003eDatasheet was not processed please search the internet for the part number for more details.\u003c\/p\u003e\u003cbr\u003e"}