Enhance your electronic applications with the GB10S07P01 AC/DC power supply, manufactured by ADVANCED ENERGY / SL POWER / CONDOR. Designed for medical and industrial grade environments, this PCB mount switching power supply offers reliable performance with a compact form factor.
Meets heavy industrial and IEC60601-1-2 EMC standards, Class B radiated & conducted EMI
Electrical Specifications
Model Number
Voltage
Output Current
Output Power
Ripple & Noise
Line Regulation
Load Regulation
GB10S07P01
7.5V
1.5A
9.8W
75mV pk-pk
±1%
±5%
Additional models available with different output voltages. Ripple & noise are measured at 20MHz bandwidth with specified test setup. All specifications are typical at 230VAC, full load, 25°C ambient.
Input & Safety
Input Voltage & Frequency: 100VAC–240VAC, ±10%, 47Hz–63Hz, 1Ø
Additional immunity and emission standards as per IEC61000-4 series
Disclaimer: The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.
{"id":10023332905277,"title":"GB10S07P01","handle":"gb10s07p01","description":"\u003ch3\u003eAC\/DC Converter 7.5V 9.8W - GB10S07P01\u003c\/h3\u003e\n\u003cp\u003eEnhance your electronic applications with the GB10S07P01 AC\/DC power supply, manufactured by ADVANCED ENERGY \/ SL POWER \/ CONDOR. Designed for medical and industrial grade environments, this PCB mount switching power supply offers reliable performance with a compact form factor.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e GB10S07P01\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ADVANCED ENERGY \/ SL POWER \/ CONDOR\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Vietnam (VN)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit of Measure:\u003c\/strong\u003e Each (EA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e EAR99\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Type:\u003c\/strong\u003e BOX\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDatasheet:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-cod\/cod-gb10s07p01.pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Features \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e10W PCB-Mount Power Supply suitable for medical and industrial applications\u003c\/li\u003e\n\u003cli\u003eCompact dimensions: 27mm x 52mm x 25mm (1.07\" x 2.05\" x 0.98\")\u003c\/li\u003e\n\u003cli\u003eUniversal input voltage range: 90VAC–264VAC* (consult factory for 277VAC option)\u003c\/li\u003e\n\u003cli\u003eHigh efficiency: \u0026gt;88% typical\u003c\/li\u003e\n\u003cli\u003eLow no-load power consumption: \u0026lt;0.1W\u003c\/li\u003e\n\u003cli\u003eLong E-cap life: \u0026gt;8 years\u003c\/li\u003e\n\u003cli\u003eMTBF: \u0026gt;800,000 hours\u003c\/li\u003e\n\u003cli\u003eSafety certifications: EN\/IEC\/UL60601-1 3rd Edition, EN\/IEC\/UL62368-1\u003c\/li\u003e\n\u003cli\u003eMeets heavy industrial and IEC60601-1-2 EMC standards, Class B radiated \u0026amp; conducted EMI\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003cth\u003eOutput Current\u003c\/th\u003e\n\u003cth\u003eOutput Power\u003c\/th\u003e\n\u003cth\u003eRipple \u0026amp; Noise\u003c\/th\u003e\n\u003cth\u003eLine Regulation\u003c\/th\u003e\n\u003cth\u003eLoad Regulation\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGB10S07P01\u003c\/td\u003e\n\u003ctd\u003e7.5V\u003c\/td\u003e\n\u003ctd\u003e1.5A\u003c\/td\u003e\n\u003ctd\u003e9.8W\u003c\/td\u003e\n\u003ctd\u003e75mV pk-pk\u003c\/td\u003e\n\u003ctd\u003e±1%\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eAdditional models available with different output voltages. Ripple \u0026amp; noise are measured at 20MHz bandwidth with specified test setup. All specifications are typical at 230VAC, full load, 25°C ambient.\u003c\/p\u003e\n\u003ch3\u003eInput \u0026amp; Safety\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInput Voltage \u0026amp; Frequency: 100VAC–240VAC, ±10%, 47Hz–63Hz, 1Ø\u003c\/li\u003e\n\u003cli\u003eInput Current: 115VAC: 0.45A, 230VAC: 0.22A\u003c\/li\u003e\n\u003cli\u003eInrush Current: \u0026lt;40A peak at 264VAC cold start\u003c\/li\u003e\n\u003cli\u003eInput Fuses: 2.0A, 250VAC in line and neutral\u003c\/li\u003e\n\u003cli\u003eEarth Leakage Current: \u0026lt;250μA@264VAC\u003c\/li\u003e\n\u003cli\u003ePatient Leakage Current: \u0026lt;100μA@264VAC\u003c\/li\u003e\n\u003cli\u003eEfficiency: \u0026gt;88%\u003c\/li\u003e\n\u003cli\u003ePower Factor: ≥0.9 at 230VAC, 80–100% load\u003c\/li\u003e\n\u003cli\u003eSafety Certifications: EN\/IEC\/UL60601-1 3rd Edition, EN\/IEC\/UL62368-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIsolation \u0026amp; Reliability\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIsolation Voltage: 4000VAC (2 x MOPP)\u003c\/li\u003e\n\u003cli\u003eDielectric Strength (Hipot): 4000VAC\u003c\/li\u003e\n\u003cli\u003eMTBF: \u0026gt;800,000 hours (full load, 110VAC \u0026amp; 220VAC, 25°C)\u003c\/li\u003e\n\u003cli\u003eE-cap Life: \u0026gt;8 years based on typical usage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental \u0026amp; Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Temperature: -25°C to +70°C (derating above 50°C)\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 5% to 90%, non-condensing\u003c\/li\u003e\n\u003cli\u003eDimensions: 27mm x 52mm x 25mm\u003c\/li\u003e\n\u003cli\u003eWeight: 100 grams\u003c\/li\u003e\n\u003cli\u003eCooling Method: Convection\u003c\/li\u003e\n\u003cli\u003eVibration \u0026amp; Shock: Compliant with industry standards for operational and non-operational conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProtection \u0026amp; EMI\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOvertemperature Protection: Auto-recovery shutdown\u003c\/li\u003e\n\u003cli\u003eOverload Protection: 130%–160% in hiccup mode\u003c\/li\u003e\n\u003cli\u003eOvervoltage Protection: 120%–150% of nominal voltage in hiccup mode\u003c\/li\u003e\n\u003cli\u003eShort Circuit Protection: Hiccup mode\u003c\/li\u003e\n\u003cli\u003eEMC Compliance: EN55032, EN55011\/CISPR11 Class B, FCC Part 15.107 \u0026amp; 15.109 Class B\u003c\/li\u003e\n\u003cli\u003eESD Immunity: Level 4 (+\/-8kV contact, +\/-15kV air)\u003c\/li\u003e\n\u003cli\u003eAdditional immunity and emission standards as per IEC61000-4 series\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eDisclaimer: The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.\u003c\/em\u003e\u003c\/p\u003e\u003cbr\u003e","published_at":"2025-08-13T22:17:06+05:30","created_at":"2025-08-13T22:17:06+05:30","vendor":"Waldom Electonics","type":"AC-DC Power Supply","tags":["5V","8W","AC","ADVAN-SLPO","IMPORT_CSV","Switching","WLDM"],"price":130969,"price_min":130969,"price_max":130969,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50616319672637,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"GB10S07P01","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"GB10S07P01","public_title":null,"options":["Default Title"],"price":130969,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"GB10S07P01","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/GB10S07P01_51198750_28cf80a7.jpg?v=1755103630"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/GB10S07P01_51198750_28cf80a7.jpg?v=1755103630","options":["Title"],"media":[{"alt":null,"id":45822413308221,"position":1,"preview_image":{"aspect_ratio":1.27,"height":200,"width":254,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/GB10S07P01_51198750_28cf80a7.jpg?v=1755103630"},"aspect_ratio":1.27,"height":200,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/GB10S07P01_51198750_28cf80a7.jpg?v=1755103630","width":254}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eAC\/DC Converter 7.5V 9.8W - GB10S07P01\u003c\/h3\u003e\n\u003cp\u003eEnhance your electronic applications with the GB10S07P01 AC\/DC power supply, manufactured by ADVANCED ENERGY \/ SL POWER \/ CONDOR. Designed for medical and industrial grade environments, this PCB mount switching power supply offers reliable performance with a compact form factor.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e GB10S07P01\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ADVANCED ENERGY \/ SL POWER \/ CONDOR\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Vietnam (VN)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit of Measure:\u003c\/strong\u003e Each (EA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e EAR99\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Type:\u003c\/strong\u003e BOX\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDatasheet:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-cod\/cod-gb10s07p01.pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Features \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e10W PCB-Mount Power Supply suitable for medical and industrial applications\u003c\/li\u003e\n\u003cli\u003eCompact dimensions: 27mm x 52mm x 25mm (1.07\" x 2.05\" x 0.98\")\u003c\/li\u003e\n\u003cli\u003eUniversal input voltage range: 90VAC–264VAC* (consult factory for 277VAC option)\u003c\/li\u003e\n\u003cli\u003eHigh efficiency: \u0026gt;88% typical\u003c\/li\u003e\n\u003cli\u003eLow no-load power consumption: \u0026lt;0.1W\u003c\/li\u003e\n\u003cli\u003eLong E-cap life: \u0026gt;8 years\u003c\/li\u003e\n\u003cli\u003eMTBF: \u0026gt;800,000 hours\u003c\/li\u003e\n\u003cli\u003eSafety certifications: EN\/IEC\/UL60601-1 3rd Edition, EN\/IEC\/UL62368-1\u003c\/li\u003e\n\u003cli\u003eMeets heavy industrial and IEC60601-1-2 EMC standards, Class B radiated \u0026amp; conducted EMI\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003cth\u003eOutput Current\u003c\/th\u003e\n\u003cth\u003eOutput Power\u003c\/th\u003e\n\u003cth\u003eRipple \u0026amp; Noise\u003c\/th\u003e\n\u003cth\u003eLine Regulation\u003c\/th\u003e\n\u003cth\u003eLoad Regulation\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGB10S07P01\u003c\/td\u003e\n\u003ctd\u003e7.5V\u003c\/td\u003e\n\u003ctd\u003e1.5A\u003c\/td\u003e\n\u003ctd\u003e9.8W\u003c\/td\u003e\n\u003ctd\u003e75mV pk-pk\u003c\/td\u003e\n\u003ctd\u003e±1%\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eAdditional models available with different output voltages. Ripple \u0026amp; noise are measured at 20MHz bandwidth with specified test setup. All specifications are typical at 230VAC, full load, 25°C ambient.\u003c\/p\u003e\n\u003ch3\u003eInput \u0026amp; Safety\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInput Voltage \u0026amp; Frequency: 100VAC–240VAC, ±10%, 47Hz–63Hz, 1Ø\u003c\/li\u003e\n\u003cli\u003eInput Current: 115VAC: 0.45A, 230VAC: 0.22A\u003c\/li\u003e\n\u003cli\u003eInrush Current: \u0026lt;40A peak at 264VAC cold start\u003c\/li\u003e\n\u003cli\u003eInput Fuses: 2.0A, 250VAC in line and neutral\u003c\/li\u003e\n\u003cli\u003eEarth Leakage Current: \u0026lt;250μA@264VAC\u003c\/li\u003e\n\u003cli\u003ePatient Leakage Current: \u0026lt;100μA@264VAC\u003c\/li\u003e\n\u003cli\u003eEfficiency: \u0026gt;88%\u003c\/li\u003e\n\u003cli\u003ePower Factor: ≥0.9 at 230VAC, 80–100% load\u003c\/li\u003e\n\u003cli\u003eSafety Certifications: EN\/IEC\/UL60601-1 3rd Edition, EN\/IEC\/UL62368-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIsolation \u0026amp; Reliability\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIsolation Voltage: 4000VAC (2 x MOPP)\u003c\/li\u003e\n\u003cli\u003eDielectric Strength (Hipot): 4000VAC\u003c\/li\u003e\n\u003cli\u003eMTBF: \u0026gt;800,000 hours (full load, 110VAC \u0026amp; 220VAC, 25°C)\u003c\/li\u003e\n\u003cli\u003eE-cap Life: \u0026gt;8 years based on typical usage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental \u0026amp; Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Temperature: -25°C to +70°C (derating above 50°C)\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 5% to 90%, non-condensing\u003c\/li\u003e\n\u003cli\u003eDimensions: 27mm x 52mm x 25mm\u003c\/li\u003e\n\u003cli\u003eWeight: 100 grams\u003c\/li\u003e\n\u003cli\u003eCooling Method: Convection\u003c\/li\u003e\n\u003cli\u003eVibration \u0026amp; Shock: Compliant with industry standards for operational and non-operational conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProtection \u0026amp; EMI\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOvertemperature Protection: Auto-recovery shutdown\u003c\/li\u003e\n\u003cli\u003eOverload Protection: 130%–160% in hiccup mode\u003c\/li\u003e\n\u003cli\u003eOvervoltage Protection: 120%–150% of nominal voltage in hiccup mode\u003c\/li\u003e\n\u003cli\u003eShort Circuit Protection: Hiccup mode\u003c\/li\u003e\n\u003cli\u003eEMC Compliance: EN55032, EN55011\/CISPR11 Class B, FCC Part 15.107 \u0026amp; 15.109 Class B\u003c\/li\u003e\n\u003cli\u003eESD Immunity: Level 4 (+\/-8kV contact, +\/-15kV air)\u003c\/li\u003e\n\u003cli\u003eAdditional immunity and emission standards as per IEC61000-4 series\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eDisclaimer: The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.\u003c\/em\u003e\u003c\/p\u003e\u003cbr\u003e"}