ADVANCED ENERGY / SL POWER / CONDOR GLC110-24G AC-DC Regulated Power Supply Module 110W
The GLC110-24G is a high-performance, regulated AC-DC power supply module designed for demanding electronic applications. Manufactured by ADVANCED ENERGY / SL POWER / CONDOR and compliant with international safety and EMC standards, this switching power supply offers reliable power conversion with excellent efficiency and safety features.
Product Features
Cost-effective power source with high reliability
Single- and dual-output configurations available
Low profile design with a height of only 1.30 inches
Power fail signal output included as standard
Commercial safety approval to UL60950-1, EN60950-1, CSA22.2 No. 950-95 3rd Ed
Medical safety approval to UL2601-1, EN60601-1, CSA-C22.2 No. 601.1
RoHS compliant model available (G suffix)
Built-in EMI filtering to meet EN55022 Class B, FCC Class B standards
Overvoltage protection on main output
High efficiency ranging from 72% to 85%
Transient response within 500 μs for a 50% load step
Technical Specifications
Parameter
Details
Input Protection
Internal AC fuse designed to blow only during catastrophic failure
Inrush Current
Limited by internal thermistors; at 240 Vac, typically not exceeding 37 A
Efficiency
72-85% depending on model
Temperature Coefficient
0.03%/°C typical on all outputs
EMI/EMC Compliance
Includes built-in EMI filtering meeting EN55022, FCC, EN61000 standards
Operating Temperature: 0 to 50°C; Non-operating: -40 to +85°C
Humidity: 0 to 95% RH
Shock: 20 g pk (operating), 40 g pk (non-operating)
Vibration: 1.5 g (operating), 5 g (non-operating)
Altitude: -500 to 10,000 ft (operating), -500 to 40,000 ft (non-operating)
Additional Information
Part Number: GLC110-24G
Manufacturer: ADVANCED ENERGY / SL POWER / CONDOR
Country of Origin: MX
Unit of Measure: EA
ECCN: EAR99
Package Type: Not specified
Datasheet: Download Datasheet
For more detailed specifications and technical details, please refer to the datasheet linked above. The datasheet was not processed; please search the internet for the part number GLC110-24G for additional information.
Use left/right arrows to navigate the slideshow or swipe left/right if using a mobile device
Choosing a selection results in a full page refresh.
Press the space key then arrow keys to make a selection.
Shopping Cart
{"id":10013833888061,"title":"GLC110-24G","handle":"glc110-24g","description":"\u003ch3\u003eADVANCED ENERGY \/ SL POWER \/ CONDOR GLC110-24G AC-DC Regulated Power Supply Module 110W\u003c\/h3\u003e\n\n\u003cp\u003eThe GLC110-24G is a high-performance, regulated AC-DC power supply module designed for demanding electronic applications. Manufactured by ADVANCED ENERGY \/ SL POWER \/ CONDOR and compliant with international safety and EMC standards, this switching power supply offers reliable power conversion with excellent efficiency and safety features.\u003c\/p\u003e\n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eCost-effective power source with high reliability\u003c\/li\u003e\n \u003cli\u003eSingle- and dual-output configurations available\u003c\/li\u003e\n \u003cli\u003eLow profile design with a height of only 1.30 inches\u003c\/li\u003e\n \u003cli\u003ePower fail signal output included as standard\u003c\/li\u003e\n \u003cli\u003eCommercial safety approval to UL60950-1, EN60950-1, CSA22.2 No. 950-95 3rd Ed\u003c\/li\u003e\n \u003cli\u003eMedical safety approval to UL2601-1, EN60601-1, CSA-C22.2 No. 601.1\u003c\/li\u003e\n \u003cli\u003eRoHS compliant model available (G suffix)\u003c\/li\u003e\n \u003cli\u003eBuilt-in EMI filtering to meet EN55022 Class B, FCC Class B standards\u003c\/li\u003e\n \u003cli\u003eOvervoltage protection on main output\u003c\/li\u003e\n \u003cli\u003eHigh efficiency ranging from 72% to 85%\u003c\/li\u003e\n \u003cli\u003eTransient response within 500 μs for a 50% load step\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n \u003cthead\u003e\n \u003ctr\u003e\n \u003cth\u003eParameter\u003c\/th\u003e\n \u003cth\u003eDetails\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003c\/thead\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd\u003eInput Protection\u003c\/td\u003e\n \u003ctd\u003eInternal AC fuse designed to blow only during catastrophic failure\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eInrush Current\u003c\/td\u003e\n \u003ctd\u003eLimited by internal thermistors; at 240 Vac, typically not exceeding 37 A\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eEfficiency\u003c\/td\u003e\n \u003ctd\u003e72-85% depending on model\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eTemperature Coefficient\u003c\/td\u003e\n \u003ctd\u003e0.03%\/°C typical on all outputs\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eEMI\/EMC Compliance\u003c\/td\u003e\n \u003ctd\u003eIncludes built-in EMI filtering meeting EN55022, FCC, EN61000 standards\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eSafety Certifications\u003c\/td\u003e\n \u003ctd\u003eUL60950-1, EN60950-1, CSA22.2 No. 950-95 3rd Ed (Commercial); UL2601-1, EN60601-1, CSA-C22.2 No. 601.1 (Medical)\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eOutput Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n \u003cthead\u003e\n \u003ctr\u003e\n \u003cth\u003eModel\u003c\/th\u003e\n \u003cth\u003eOutput Voltage\u003c\/th\u003e\n \u003cth\u003eOutput Current (Normal)\u003c\/th\u003e\n \u003cth\u003ePeak Output Current\u003c\/th\u003e\n \u003cth\u003eOutput Noise (P-P)\u003c\/th\u003e\n \u003cth\u003eOvervoltage Protection (OVP)\u003c\/th\u003e\n \u003cth\u003eTotal Regulation\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003c\/thead\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd\u003eGLC110-24G\u003c\/td\u003e\n \u003ctd\u003e+24 V\u003c\/td\u003e\n \u003ctd\u003e3.2 A\u003c\/td\u003e\n \u003ctd\u003e4.6 A\u003c\/td\u003e\n \u003ctd\u003e240 mV\u003c\/td\u003e\n \u003ctd\u003e± 2.5 V\u003c\/td\u003e\n \u003ctd\u003e2%\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eGLC110-15G\u003c\/td\u003e\n \u003ctd\u003e+15 V\u003c\/td\u003e\n \u003ctd\u003e5 A\u003c\/td\u003e\n \u003ctd\u003e7.7 A\u003c\/td\u003e\n \u003ctd\u003e150 mV\u003c\/td\u003e\n \u003ctd\u003e± 1.5 V\u003c\/td\u003e\n \u003ctd\u003e2%\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eGLC110-12G\u003c\/td\u003e\n \u003ctd\u003e+12 V\u003c\/td\u003e\n \u003ctd\u003e6.3 A\u003c\/td\u003e\n \u003ctd\u003e9.1 A\u003c\/td\u003e\n \u003ctd\u003e120 mV\u003c\/td\u003e\n \u003ctd\u003e± 1.1 V\u003c\/td\u003e\n \u003ctd\u003e2%\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eGLC110-524\u003c\/td\u003e\n \u003ctd\u003e+24 V \/ -12 V\u003c\/td\u003e\n \u003ctd\u003e3.2 A \/ 0 A\u003c\/td\u003e\n \u003ctd\u003e4.6 A \/ 2.5 A\u003c\/td\u003e\n \u003ctd\u003e200 mV\u003c\/td\u003e\n \u003ctd\u003e± 2.5 V\u003c\/td\u003e\n \u003ctd\u003e2%\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eMechanical \u0026amp; Environmental Specifications\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eOperating Temperature: 0 to 50°C; Non-operating: -40 to +85°C\u003c\/li\u003e\n \u003cli\u003eHumidity: 0 to 95% RH\u003c\/li\u003e\n \u003cli\u003eShock: 20 g pk (operating), 40 g pk (non-operating)\u003c\/li\u003e\n \u003cli\u003eVibration: 1.5 g (operating), 5 g (non-operating)\u003c\/li\u003e\n \u003cli\u003eAltitude: -500 to 10,000 ft (operating), -500 to 40,000 ft (non-operating)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAdditional Information\u003c\/h3\u003e\n\u003cp\u003ePart Number: GLC110-24G\u003cbr\u003e\nManufacturer: ADVANCED ENERGY \/ SL POWER \/ CONDOR\u003cbr\u003e\nCountry of Origin: MX\u003cbr\u003e\nUnit of Measure: EA\u003cbr\u003e\nECCN: EAR99\u003cbr\u003e\nPackage Type: Not specified\u003cbr\u003e\nDatasheet: \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-cod\/cod-glc110-24g.pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\n\u003cp\u003eFor more detailed specifications and technical details, please refer to the datasheet linked above. The datasheet was not processed; please search the internet for the part number GLC110-24G for additional information.\u003c\/p\u003e","published_at":"2025-08-10T22:54:00+05:30","created_at":"2025-08-10T22:54:00+05:30","vendor":"Waldom Electonics","type":"AC-DC Power Supply","tags":["110W","AC","ADVAN-SLPO","IMPORT_CSV","Power","Switching","WLDM"],"price":828358,"price_min":828358,"price_max":828358,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50579073630525,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"GLC110-24G","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"GLC110-24G","public_title":null,"options":["Default Title"],"price":828358,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"GLC110-24G","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/GLC110-24G_11158703_0e49f35a.jpg?v=1754846643"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/GLC110-24G_11158703_0e49f35a.jpg?v=1754846643","options":["Title"],"media":[{"alt":null,"id":45766434947389,"position":1,"preview_image":{"aspect_ratio":1.0,"height":200,"width":200,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/GLC110-24G_11158703_0e49f35a.jpg?v=1754846643"},"aspect_ratio":1.0,"height":200,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/GLC110-24G_11158703_0e49f35a.jpg?v=1754846643","width":200}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eADVANCED ENERGY \/ SL POWER \/ CONDOR GLC110-24G AC-DC Regulated Power Supply Module 110W\u003c\/h3\u003e\n\n\u003cp\u003eThe GLC110-24G is a high-performance, regulated AC-DC power supply module designed for demanding electronic applications. Manufactured by ADVANCED ENERGY \/ SL POWER \/ CONDOR and compliant with international safety and EMC standards, this switching power supply offers reliable power conversion with excellent efficiency and safety features.\u003c\/p\u003e\n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eCost-effective power source with high reliability\u003c\/li\u003e\n \u003cli\u003eSingle- and dual-output configurations available\u003c\/li\u003e\n \u003cli\u003eLow profile design with a height of only 1.30 inches\u003c\/li\u003e\n \u003cli\u003ePower fail signal output included as standard\u003c\/li\u003e\n \u003cli\u003eCommercial safety approval to UL60950-1, EN60950-1, CSA22.2 No. 950-95 3rd Ed\u003c\/li\u003e\n \u003cli\u003eMedical safety approval to UL2601-1, EN60601-1, CSA-C22.2 No. 601.1\u003c\/li\u003e\n \u003cli\u003eRoHS compliant model available (G suffix)\u003c\/li\u003e\n \u003cli\u003eBuilt-in EMI filtering to meet EN55022 Class B, FCC Class B standards\u003c\/li\u003e\n \u003cli\u003eOvervoltage protection on main output\u003c\/li\u003e\n \u003cli\u003eHigh efficiency ranging from 72% to 85%\u003c\/li\u003e\n \u003cli\u003eTransient response within 500 μs for a 50% load step\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n \u003cthead\u003e\n \u003ctr\u003e\n \u003cth\u003eParameter\u003c\/th\u003e\n \u003cth\u003eDetails\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003c\/thead\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd\u003eInput Protection\u003c\/td\u003e\n \u003ctd\u003eInternal AC fuse designed to blow only during catastrophic failure\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eInrush Current\u003c\/td\u003e\n \u003ctd\u003eLimited by internal thermistors; at 240 Vac, typically not exceeding 37 A\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eEfficiency\u003c\/td\u003e\n \u003ctd\u003e72-85% depending on model\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eTemperature Coefficient\u003c\/td\u003e\n \u003ctd\u003e0.03%\/°C typical on all outputs\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eEMI\/EMC Compliance\u003c\/td\u003e\n \u003ctd\u003eIncludes built-in EMI filtering meeting EN55022, FCC, EN61000 standards\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eSafety Certifications\u003c\/td\u003e\n \u003ctd\u003eUL60950-1, EN60950-1, CSA22.2 No. 950-95 3rd Ed (Commercial); UL2601-1, EN60601-1, CSA-C22.2 No. 601.1 (Medical)\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eOutput Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n \u003cthead\u003e\n \u003ctr\u003e\n \u003cth\u003eModel\u003c\/th\u003e\n \u003cth\u003eOutput Voltage\u003c\/th\u003e\n \u003cth\u003eOutput Current (Normal)\u003c\/th\u003e\n \u003cth\u003ePeak Output Current\u003c\/th\u003e\n \u003cth\u003eOutput Noise (P-P)\u003c\/th\u003e\n \u003cth\u003eOvervoltage Protection (OVP)\u003c\/th\u003e\n \u003cth\u003eTotal Regulation\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003c\/thead\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd\u003eGLC110-24G\u003c\/td\u003e\n \u003ctd\u003e+24 V\u003c\/td\u003e\n \u003ctd\u003e3.2 A\u003c\/td\u003e\n \u003ctd\u003e4.6 A\u003c\/td\u003e\n \u003ctd\u003e240 mV\u003c\/td\u003e\n \u003ctd\u003e± 2.5 V\u003c\/td\u003e\n \u003ctd\u003e2%\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eGLC110-15G\u003c\/td\u003e\n \u003ctd\u003e+15 V\u003c\/td\u003e\n \u003ctd\u003e5 A\u003c\/td\u003e\n \u003ctd\u003e7.7 A\u003c\/td\u003e\n \u003ctd\u003e150 mV\u003c\/td\u003e\n \u003ctd\u003e± 1.5 V\u003c\/td\u003e\n \u003ctd\u003e2%\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eGLC110-12G\u003c\/td\u003e\n \u003ctd\u003e+12 V\u003c\/td\u003e\n \u003ctd\u003e6.3 A\u003c\/td\u003e\n \u003ctd\u003e9.1 A\u003c\/td\u003e\n \u003ctd\u003e120 mV\u003c\/td\u003e\n \u003ctd\u003e± 1.1 V\u003c\/td\u003e\n \u003ctd\u003e2%\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eGLC110-524\u003c\/td\u003e\n \u003ctd\u003e+24 V \/ -12 V\u003c\/td\u003e\n \u003ctd\u003e3.2 A \/ 0 A\u003c\/td\u003e\n \u003ctd\u003e4.6 A \/ 2.5 A\u003c\/td\u003e\n \u003ctd\u003e200 mV\u003c\/td\u003e\n \u003ctd\u003e± 2.5 V\u003c\/td\u003e\n \u003ctd\u003e2%\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eMechanical \u0026amp; Environmental Specifications\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eOperating Temperature: 0 to 50°C; Non-operating: -40 to +85°C\u003c\/li\u003e\n \u003cli\u003eHumidity: 0 to 95% RH\u003c\/li\u003e\n \u003cli\u003eShock: 20 g pk (operating), 40 g pk (non-operating)\u003c\/li\u003e\n \u003cli\u003eVibration: 1.5 g (operating), 5 g (non-operating)\u003c\/li\u003e\n \u003cli\u003eAltitude: -500 to 10,000 ft (operating), -500 to 40,000 ft (non-operating)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAdditional Information\u003c\/h3\u003e\n\u003cp\u003ePart Number: GLC110-24G\u003cbr\u003e\nManufacturer: ADVANCED ENERGY \/ SL POWER \/ CONDOR\u003cbr\u003e\nCountry of Origin: MX\u003cbr\u003e\nUnit of Measure: EA\u003cbr\u003e\nECCN: EAR99\u003cbr\u003e\nPackage Type: Not specified\u003cbr\u003e\nDatasheet: \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-cod\/cod-glc110-24g.pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\n\u003cp\u003eFor more detailed specifications and technical details, please refer to the datasheet linked above. The datasheet was not processed; please search the internet for the part number GLC110-24G for additional information.\u003c\/p\u003e"}