The ADVANCED ENERGY / SL POWER / CONDOR GLC75-12G is a high-performance AC-DC power supply designed for demanding electronic applications. This switching power supply delivers reliable, efficient power with a compact form factor suitable for 1U rack-mount installations.

Key Features

  • Cost-effective single-output power source
  • Universal input voltage range: 90-264 Vac, 47-63 Hz, single phase
  • Output Power: 75 W continuous, up to 110 W with airflow
  • Output Voltage: 12 V with regulation accuracy within ±5%
  • High efficiency: 72-85% depending on model
  • Built-in EMI filtering exceeding FCC Class B and CISPR 22 standards
  • Overload and short circuit protection with cycling power limit
  • Overvoltage protection and adjustable output voltage
  • Meets safety standards: UL1950, CSA22.2 No. 234, IEC950, EN60950
  • Medical safety approval to UL2601-1, IEC601-1, CSA22.2 No. 601
  • RoHS compliant
  • 2-year warranty

Technical Specifications

Parameter Details
Part Number GLC75-12G
Manufacturer ADVANCED ENERGY / SL POWER / CONDOR
Country of Origin MX
UOM EA
ECCN EAR99
Package Type Not specified
Datasheet Download Datasheet

Electrical and Mechanical Specifications

  • Input Voltage: 90-264 Vac, 47-63 Hz, single phase
  • Input Current: Max 2.3 A at 120 Vac, full load
  • Output Power: 75 W continuous; 110 W with airflow
  • Output Regulation: 5% to 50% load or 50% to full load
  • Overload Protection: Power limiting at approximately 120 W, protected against short circuit and overload
  • Output Noise: 0.5% rms, 1% pk-pk, 20 MHz bandwidth
  • Transient Response: 500 µs typical for 50% load step
  • Efficiency: 72-85%
  • Inrush Current: Limited by thermistors; <37 A at 240 Vac cold start
  • Temperature Coefficient: 0.03%/°C
  • Power Fail Signal: Goes low 5 ms before voltage drops more than 4%
  • EMI/EMC Compliance: Meets EN55022 Class B, FCC Class B, EN61000-4 series, and EN61000-3-2 Class A standards

Environmental & Mechanical

Parameter Details
Operating Temperature 0 to 50°C; -40 to +85°C (with derating)
Humidity 0 to 95% RH
Shock 20 g peak (operating), 40 g peak (non-operating)
Vibration 1.5 g rms, 0.003 g²/Hz (operating), 5 g rms, 0.026 g²/Hz (non-operating)
Mechanical Size 3.4" x 5.75" x 1.56" (meets 1U applications)

Additional Information

For more detailed specifications and application guidance, please refer to the datasheet. This product is suitable for commercial and medical applications, with appropriate safety and EMI certifications.