ADVANCED ENERGY / SL POWER / CONDOR AC-DC Regulated Power Supply Module 75W (Part Number: GLM75AG)
Ensure reliable power conversion with the GLM75AG AC-DC regulated power supply module from ADVANCED ENERGY / SL POWER / CONDOR. Designed for applications requiring high efficiency and compliance with international safety standards, this 75W switching power supply offers versatile features suitable for both commercial and medical environments.
Product Features
- Cost-effective multiple output power source
- Universal input voltage range of 90-264 Vac for global compatibility
- Compact dimensions: 7.00” x 4.25” x 1.30” (meets 1U height)
- Built-in EMI filtering exceeding FCC Class B and CISPR 22 standards
- Compliance with safety standards including UL1950, CSA22.2 No. 950, EN60950-1, UL2601-1, CSA22.2 No. 601.1-M90, IEC/EN60601-1
- RoHS compliant model available (G suffix)
- 2-year warranty for reliable operation
Electrical Specifications
| Parameter | Details |
|---|---|
| Efficiency | 68% - 78% depending on model and load distribution |
| Input Protection | Internal AC fuse, designed to blow only during catastrophic failure |
| Inrush Current | Limited by internal thermistors; at 240 Vac, max 37 A during cold start |
| Hold Up Time | Minimum 20 ms at full load, 120 Vac input |
| Temperature Coefficient | 0.03%/°C typical on all outputs |
| Power Fail Signal | TTL/CMOS compatible, goes low 5 ms before voltage drops more than 4% |
| EMI/EMC Compliance | Meets EN55022 Class B, FCC Class B, EN61000-4 series, and EN61000-3-2 Class A standards |
| Safety Approvals | UL1950, CSA22.2 No. 950, EN60950-1, UL2601-1 (medical), CSA22.2 No. 601.1-M90, IEC/EN60601-1 |
| Leakage Current (Medical) | 70 μA at 264 V, 50 Hz |
Outputs and Models
| Model | Outputs | Output Voltages | Current Ratings (A) | Overvoltage Protection (V) | Noise (mV) | Regulation |
|---|---|---|---|---|---|---|
| GLC75A / GLM75A | 4 | +5.1 V, +12 V, -12 V, +12 V | 1, 8, 10, 1 | 2 A, 6.2 V ± 0.6 V | 50 mV, 120 mV, 120 mV, 120 mV | 2% +10%,-5%, 3%, 2% |
| GLC75B / GLM75B | 4 | +5.1 V, +12 V, -5 V, +12 V | 1, 8, 10, 1 | 2 A, 6.2 V ± 0.6 V | 50 mV, 120 mV, 50 mV, 120 mV | 2% +10%,-5%, 3%, 2% |
| GLC75C / GLM75C | 4 | +5.1 V, +12 V, -15 V, +15 V | 1, 8, 10, 1 | 2 A, 6.2 V ± 0.6 V | 50 mV, 120 mV, 150 mV, 150 mV | 2% +10%,-5%, 3%, 2% |
| GLC75D / GLM75D | 4 | +5.1 V, +24 V, -12 V, +12 V | 1, 8, 10, 1 | 2 A, 6.2 V ± 0.6 V | 50 mV, 240 mV, 120 mV, 120 mV | 2% +10%,-5%, 3%, 2% |
| GLC75E / GLM75E | 4 | +5.1 V, +24 V, -15 V, +15 V | 1, 8, 10, 1 | 2 A, 6.2 V ± 0.6 V | 50 mV, 240 mV, 150 mV, 150 mV | 2% +10%,-5%, 3%, 2% |
| GLC75F / GLM75F | 4 | +5.1 V, +15 V, -5 V, -15 V | 1, 8, 10, 1 | 2 A, 6.2 V ± 0.6 V | 50 mV, 150 mV, 50 mV, 150 mV | 2% +10%,-5%, 3%, 2% |
| GLC75H / GLM75H | 4 | +5.1 V, +15 V, -15 V, +15 V | 1, 8, 10, 1 | 2 A, 6.2 V ± 0.6 V | 50 mV, 150 mV, 150 mV, 150 mV | 2% +10%,-5%, 3%, 2% |
| GLC75J / GLM75J | 4 | +5.1 V, +12 V, -12 V, 5 V | 1, 8, 10, 1 | 2 A, 6.2 V ± 0.6 V | 50 mV, 120 mV, 120 mV, 50 mV | 2% +10%,-5%, 3%, 2% |
| GLC75P / GLM75P | 4 | +5.1 V, +24 V, -12 V, +12 V | 1, 8, 10, 1 | 2 A, 6.2 V ± 0.6 V | 50 mV, 240 mV, 120 mV, 120 mV | 2% +10%,-5%, 3%, 2% |
Environmental & Mechanical Specifications
- Operating temperature: 0 to 50°C; Non-operating: -40 to +85°C
- Humidity: 0 to 95% RH
- Shock: 20 g pk (operating), 40 g pk (non-operating)
- Vibration: 1.5 g rms (operating), 5 g rms (non-operating)
- Altitude: -500 to 10,000 ft (operating), -500 to 40,000 ft (non-operating)
For detailed specifications and datasheet, please visit: Datasheet.
Note: All specifications are typical at nominal input, full load, and 25°C unless otherwise stated. Please refer to the datasheet for complete details.
Want to buy in bulk?
Custom Requirements?
Discussion Forum